Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Training and Education”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Volume 9: Critical Facility with Add-On Ion Beam

Completion of the originally planned critical facility has been considered as part of the High Flux Isotope Reactor (HFIR) Sustaining and Enhancing Neutron Science Initiative at Oak Ridge National Laboratory (ORNL). A working group of ORNL staff members was formed to develop the idea and to recommend one or more configurations to best support future HFIR operations and scientific capacities. HFIR was designed with a critical pool in the reactor bay that was projected to be outfitted as a critical facility. The primary purpose of the planned critical facility was to measure the subcritical worth of fresh fuel elements to support startup requirements. However, the Y-12 National Security Complex already housed a critical facility that was used for this purpose. This report presents the working group’s efforts, including determination of the proposed critical facility’s high-impact benefits. A generic low-power critical facility would be employed for reactor physics measurements, code and data validation, reactor operator and staff training, and education. This facility would be instrumental in supporting current HFIR operations, conversion of HFIR to low-enriched uranium, existing light water reactor operations, and advanced reactor development and deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Clean Energy Employment Impacts and Occupational Analyses: Building Envelope & Electrification Upgrades

Under the Communities LEAP (Local Energy Action Program) Pilot, the U.S. Department of Energy (DOE) is working with a group of LEAP communities to bolster workforce development initiatives and support the growth of local employment in the clean energy economy. Through this resource, DOE seeks to provide participating communities with an overview of the types of occupations that could be affected by investments in building envelope and building electrification upgrades in existing building stock - differentiating between the residential and commercial sectors. This occupational analysis is intended to be used by communities to inform workforce initiatives (e.g., local training and education programs) as they implement building energy efficiency and electrification projects at scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Collaborative Industrial Assessment Center (IAC) for Expanded Outreach within the Southeast

This GA-FL IAC had impacts on workforce development and economic impact for regional small- and medium-sized enterprises. Qualified faculty and campus staff educated and trained cohorts of students regarding state-of-the-art industrial assessments. Students gained hands-on experiences in learning about manufacturing processes, energy systems, developing assessment recommendations/calculations, and client interaction. These skills were complemented by the incorporation of IAC themes into some course curricula. As far as economic impact, the center conducted 66 assessments over 5 years primarily in Georgia and Florida. These represented hundreds of thousands of dollars in potential annual resource savings to the clients and region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beams of polarized hadrons at EIC: Action plan to address acute challenges

In the recent years, more and more groups in the field of polarization instrumentation and technology have disappeared, taking their expertise in the experimental technologies with them. When the RHIC was conceived, there were numerous experimental and theoretical groups around the world from which experts could be recruited to build new instruments, powerful sources, specialized detector systems, investigate new approaches and concepts, and much more. We should recognize that we presently are in a critical situation regarding the availability of skilled individuals to provide and service the required instruments to make the EIC a success. We need to rejuvenate the field of polarization technology, especially for hadrons, and significantly expand education and training efforts. The document highlights a number of key areas that require attention. Three scientists/engineers/postdocs and at least one or two PhD students should be sought immediately to start building a group capable of tackling the future tasks and challenges in hadron polarimetry at the EIC.

43 PARTICLE ACCELERATORS↗

Twentieth Exotic Beam Summer School (EBSS2023)

The study of unstable nuclei with unusual ratios of protons to neutrons is one of the frontiers of science. Investigating these rare isotopes is critical for understanding the synthesis of the chemical elements in stellar explosions as well as the fundamental nature of the nuclear forces that bind atomic nuclei together. Scientific progress in this field is driven by the development of exotic beams in present and next-generation rare-isotope beam facilities including the Facility for Rare Isotope Beams (FRIB). Nuclear physics is a broad discipline, influencing our knowledge on subjects as diverse as weakly-bound nuclei, many-body quantum theory, the super heavy elements, and the inner structure of neutron stars. Applications based on nuclear science and technologies include medical diagnostics and therapies, materials science, and national security. The major goal achieved in this project was to hold Exotic Beam Summer School 2023 (EBSS2023), the twentieth installment of EBSS series, July 9-15, 2023 at the Facility for Rare Isotope Beams on the campus of Michigan State University to educate and train the next generation of scientists that will drive research with rare-isotope beams. FRIB became operational in 2022 and is now providing beams of exotic nuclei that will ramp up to unmatched intensities, exceeding what is available today by orders of magnitude. Beams available at FRIB are facilitating a wide variety of studies in nuclear structure, astrophysics, fundamental symmetries and societal applications. There is a large community of scientists interested in working with rare isotope beams; for example, the FRIB User Organization currently has over 1,700 members. In order to maximize the scientific output of FRIB, there must be a workforce continuously trained in both the physics of exotic beams and in the practical techniques of carrying out an experiment. This summer school series is designed to specifically address this need - to ensure that new generations of scientists from a broad range of institutions and backgrounds is trained, motivated, and equipped to push the field forward to new and important breakthroughs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evolving Competitive Markets in SAPP: Leveraging Competitive Wholesale Electricity Markets to Drive Renewable Generation Capacity in the Southern African Power Pool (SAPP)

The SADC region has significant natural resource potential to increase renewable energy generation, improve electricity reliability, and support economic development. This research finds an apparent lack of confidence from electricity infrastructure investors in SAPP wholesale electricity markets, which increases risk perception and lowers the likelihood of capital deployment. With respect to free market fundamentals, competitive market obstacles and renewable energy development obstacles are characterized. Stakeholders identified the top obstacles to well-functioning competitive markets as insufficient transmission infrastructure for interconnection and regional movement of electricity, dominance of national single-buyer markets, and lack of or weak nation-state regulatory frameworks. Stakeholders prioritized the top three obstacles for renewable energy development as a lack of viable commercial arrangements for variable renewable energy (VRE) balancing, lack of functional and consistent nation-level regulations, and higher project costs related to reliance on imported equipment. With respect to potential solution options, stakeholders prioritized the development of new cost allocation and finance methods to facilitate new transmission expansion, training to educate new or potential new market entrants on SAPP processes, as well as modeling and analysis of regional SAPP participation benefits disaggregated to the nation-state level. From these perspectives, this research identified strategy options for consideration including transitioning SAPP to a regional transmission operator (RTO) for operation and planning of cross-border transmission facilities and market administration, shifting operations of SAPP member transmission systems to Independent System Operators (ISOs), establishing a regional regulatory authority and enhancing market data transparency. Implementing these reforms is expected to be challenging, but not insurmountable, given the domestic political, legal, and jurisdictional complexities of the SADC region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Floating Offshore Wind US Manufacturing and Commercialization: Cooperative Research and Development (Final Report)

NREL assessed the supply chain and workforce considerations for the OCG-Wind floater technology, a floating semi-submersible offshore wind substructure, as well sharing vessel needs to inform their installation strategy. This technical assistance was in support of the FLoating Offshore Wind ReadINess (FLOWIN) Prize Phase 2 submission. NREL provided an assessment of domestic supplier capabilities for the main components of their floating offshore wind platform design and analyzed US regional and national supply chain constraints and gaps. Thirteen interviews with companies including steel distributors, forges, foundries, ports, large component fabricators, subcomponent fabricators, and secondary suppliers provided key insights such as 1) assembly ports are the key infrastructure barrier standing in the way of unlocking the domestic assembly and component fabrication for steel-based FOW platforms, 2) domestic steel producers can supply the types and quantities of steel necessary for FOW platforms, and 3) coordination between stakeholders will be a vital part of successfully developing the supply chain and infrastructure needed to domestically produce FOW platforms. In the workforce assessment, NREL documented a step-by-step approach to conduct a place-based assessment of the foundational workforce consideration for recruiting, upskilling, and retaining a workforce, such as supportive local and state policy, nearby education and training programs, and existing relevant industry. This approach was applied to Tacoma, Washington. Tacoma was indicated to have the potential be a successful location for fabrication and assembly of floating offshore wind energy in terms of workforce development. To share data on vessel requirements to install the OCG-Wind floater, NREL compiled resources that help answer the questions related to anchor handling tug vessels, shared a database of cable laying vessels, and answered questions on complying with the Jones Act.

17 WIND ENERGY↗

Securing Solar for the Grid (S2G) (Final Project Report) [Slides]

This is the final technical report for the SETO-funded project Securing Solar for the Grid (S2G) from FY22-24. The project scope included development and dissemination of standards' requirements, best practices, equipment testing procedures, assessment tools, as well as education and training materials for cyber defense, posture and maturity tailored to solar technologies. The outcomes for this work include: co-led the development of cybersecurity certification standard (UL2941), co-led the development of cybersecurity guide (IEEE1547.3), development of recommendations for supply chain cybersecurity, and development of cybersecurity risk profiles and recommendations for DERMS.

14 SOLAR ENERGY↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Technical Report for U.S.-Japan Hadronic Physics Exchange Program for Studies of Hadron Structure and QCD

Nuclear physics explores the fundamental properties of matter -- how protons and neutrons emerge as quantum systems of elementary particles, how they form the atomic nuclei, and how they give rise to the wide variety of phenomena and applications at biological, technical, and astronomical scales. It is a global scientific effort centered around large-scale experimental user facilities (particle accelerators and detectors), advanced theoretical methods and concepts, and computational techniques and resources. Exchange of knowledge and ideas, scientific collaboration, and workforce development on a global scale are essential for the future of the field. The nuclear physics program envisaged in the 2023 DOE/NSF NSAC Long-Range Plan and pursued at the U.S. National Labs has strong synergies with programs at other facilities worldwide and will realize significant benefits from international collaboration. Nuclear physics is also recognized for promoting international cooperation in the broadest sense through joint construction and operation of experimental equipment, personal contacts between scientists, and education and training. The U.S.-Japan Hadronic Physics Exchange Program (USJPHE) supported collaborative scientific research in hadronic physics and quantum chromodynamics. USJHPE focused on subject areas related to the programs at current and future experimental facilities in the U.S.\ and Japan and supported both experimental and theoretical studies. USJHPE particularly aimed to realize synergies between the hadronic physics programs at Jefferson Lab 12 GeV and J-PARC resulting from the complementarity of electromagnetic and hadronic probes in the multi-GeV energy range. Subject areas of common interest included the quark-gluon structure of hadrons and nuclei, meson and baryon spectroscopy, strangeness and hypernuclear physics, and other related topics. USJHPE also supported research in hadronic physics and nuclear-physics-enabled tests of fundamental symmetries related to the programs at Brookhaven National Lab, Fermilab, KEK, Spring-8, and university-based facilities in the U.S. and Japan. USJHPE especially promoted collaboration between the U.S. and Japanese nuclear physics communities in developing the physics program and instrumentation for the future Electron-Ion Collider. USJHPE was intended to provide travel grants to U.S.-based scientists (primary institutional affiliation with a U.S.\ university, national laboratory, or other research center) to visit Japanese institutions and conduct collaborative research there. The program supported senior researchers, postdoctoral fellows, and students. Continuing the setup of the preceding grant period, J-PARC served as the Japanese “hub” for U.S. physicists for short- and long-term visits, and JLab served as the corresponding U.S. “hub”. The program was officially managed through the U. of Connecticut in Storrs, CT. Support for Japanese physicists visiting the U.S. was provided through funds from Japanese funding agencies. The USJHPE program promoted the scientific exchange and the collaborative spirit in hadronic physics between the two countries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

KBase Educators Overview

KBase worked with a community of instructors to create a connected workflow that integrates genomics, metagenomics, phylogenetics, and pangenomic concepts in a “choose your own adventure” framework. Each concept is stand alone, while complementing one another as they flow from one topic to another across concepts. The pace of each workflow can be adjusted with the flexibility of modules that are shareable and allow students to copy and interact with data and analyses.

Data science, Education, Training, Genomics, Metag↗

Methods of Securing Chemical and Pharmaceutical Knowledge and Recommendations for International Institutions to Enhance Research Integrity

Here, this paper examines strategies for securing chemical and pharmaceutical expertise in a globalized research environment, focusing on safeguarding intellectual property and preventing the misuse of sensitive and potentially dual-use information. The product of collective efforts between Pacific Northwest National Laboratory, Carol Davila University of Medicine and Pharmacy, and New Bulgarian University, highlights the challenges and opportunities posed by cross-border research collaborations, particularly in the context of differing regulatory frameworks and research cultures. It explores current mechanisms to prevent data loss and unauthorized access to sensitive information while assessing the effectiveness of existing security measures, frameworks, and international export control regimes. The approach examines the differing methodologies for promoting transparency, trust-building, and mutual accountability in joint research projects to cultivate secure data-sharing practices and intellectual property. It provides recommendations for international institutions to implement security guidelines in framing research priorities, encourages continual training and education programs, and the integration of processes for monitoring research compliance. This partnership aims to advance scientific innovation while maintaining global stability, ensuring compliance with international norms, and safeguarding valuable intellectual property as measures in chemical and pharmaceutical research security practices continue to expand due to international collaboration and knowledge exchange.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Review of the Evaluation of Building Energy Code Compliance in the United States

Building energy codes are essential tools for achieving energy efficiency in buildings. However, the full energy savings potential of these codes can only be realized if buildings are constructed in compliance with them. Therefore, evaluating building energy code compliance is crucial in bridging the gap between the energy efficiency requirements set by energy codes and the actualized energy savings achieved. An energy code compliance evaluation serves as a mechanism to assess construction practices, evaluate the effectiveness of code enforcement, identify gaps in compliance, and guide strategies for improvement through training and education. Conducting code compliance evaluation activities involves field studies that require careful design and significant resources. Historically, more emphasis has been placed on developing and adopting building energy codes, while efforts to evaluate compliance have been relatively limited and lacking consistent approaches. The passage of the 2009 American Recovery and Reinvestment Act (ARRA), which mandated that states create plans for achieving 90% compliance within eight years, stimulated the need for an energy code compliance evaluation. As a result, federal, state, and local governments, and utilities have invested in the development of methodologies and tools for code compliance evaluation studies. This paper reviews the code compliance evaluation studies conducted in the United States over the past three decades. It describes and compares the methodologies and metrics used to assess building energy code compliance, summarizes the general elements and steps involved in the evaluation process, and discusses common issues in these studies. Over time, code compliance evaluation methodologies have evolved from isolated development within individual states, regions, and utilities, to widely accepted protocols applicable across different states and local jurisdictions. There has been a transition in compliance metrics, shifting from historical compliance rates to energy-consumption-oriented approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The role of international collaboration in the United States geologic disposal research program

Abstract. More than a decade ago, the United States disposal program discontinued all research activities focused on the unsaturated fractured tuff formation at Yucca Mountain as the geologic disposal site for spent fuel and high-level radioactive waste. A new research and development (R&D) program was initiated to provide a sound technical basis for alternative disposal options across clay, crystalline, and salt rocks. The goals of this broad program were (and still are) to (1) increase confidence in the robustness of generic disposal concepts, (2) develop the science and engineering tools needed to support disposal concept implementation, and (3) conduct R&D on the direct disposal of existing dual-purpose (storage and transportation) canisters. Recognizing the benefits of international collaboration toward the common goal of safely and efficiently managing the back end of the nuclear fuel cycle, the program emphasized international cooperation as an effective strategy for sharing information and knowledge. In a multi-laboratory effort coordinated by Lawrence Berkeley National Laboratory, the United States Department of Energy (DOE) program established formal and informal cooperation partnerships with several international initiatives and institutions and developed a number of collaborative R&D activities in important research areas, such as engineered barrier integrity, near-field perturbations, radionuclide transport, performance assessment, and methods for characterization and monitoring of engineered and natural barriers. This presentation gives an overview of these R&D activities, with a specific focus on activities that improve our current understanding of the coupled thermal–hydrological–mechanical–chemical (THMC) processes occurring in engineered and natural barriers. We start with a brief review of selected international collaboration initiatives and then describe a few specific collaboration projects. We focus specifically on such studies that use experimental data sets provided by international research cooperation for joint modeling work to increase confidence in performance-relevant predictions of coupled processes. Overall, the focus on international collaboration has allowed deep engagement of US researchers with the international waste management R&D community in terms of best practices, new scientific advances, state-of-the-art simulation tools, new monitoring and performance confirmation approaches, and lessons learned. The joint R&D with international researchers, worldwide sharing of knowledge and experience, and access to relevant data and experiments from a variety of host rocks have helped our researchers to significantly improve their understanding of the current technical basis for disposal in a range of potential host rock environments. International collaboration also provides ample opportunity for training and educating junior staff that are well suited to move the United States disposal research program forward into the next decades, a promising avenue for developing a next-generation workforce of disposal scientists.

Birkholzer, Jens T.↗