Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Trace gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Monitoring the inundation extent of the Florida Everglades with AVHRR data in a geographic information system

The purpose of the study is to develop a geographical information system capable of estimating methane and other greenhouse trace-gas fluxes from the wetlands of the Florida Everglades. Advanced very-high-resolution radiometer (AVHRR) data collected on a near-monthly basis for a year in order to monitor the seasonal dynamics of inundation extent across the Everglades is utilized in the analysis. It is noted that AVHRR data presents advantages over other remote-sensing data sources employed in covering large geographical regions due to its daily coverage with multiple opportunities during a day. This temporal resolution allows the realistic expectation of acquiring data on a frequent basis.

Pelletier, R. E.↗

Direct analysis of organic priority pollutants by IMS

Many routine methods for monitoring of trace amounts of atmospheric organic pollutants consist of several steps. Typical steps are: (1) collection of the air sample; (2) trapping of organics from the sample; (3) extraction of the trapped organics; and (4) identification of the organics in the extract by GC (gas chromatography), HPLC (High Performance Liquid Chromatography), or MS (Mass Spectrometry). These methods are often cumbersome and time consuming. A simple and fast method for monitoring atmospheric organics using an IMS (Ion Mobility Spectrometer) is proposed. This method has a short sampling time and does not require extraction of the organics since the sample is placed directly in the IMS. The purpose of this study was to determine the responses in the IMS to organic 'priority pollutants'. Priority pollutants including representative polycyclic aromatic hydrocarbons (PAHs), phthalates, phenols, chlorinated pesticides, and polychlorinated biphenyls (PCB's) were analyzed in both the positive and negative detection mode at ambient atmospheric pressure. Detection mode and amount detected are presented.

Giam, C. S.↗

Design and Testing of Trace Contaminant Injection and Monitoring Systems

In support of the Carbon dioxide And Moisture Removal Amine Swing-bed (CAMRAS) testing, a contaminant injection system as well as a contaminant monitoring system has been developed by the Johnson Space Center Air Revitalization Systems (JSC-ARS) team. The contaminant injection system has been designed to provide trace level concentrations of contaminants generated by humans in a closed environment during space flight missions. The contaminant injection system continuously injects contaminants from three gas cylinders, two liquid reservoirs and three permeation ovens. The contaminant monitoring system has been designed to provide real time gas analysis with accurate flow, humidity and gas concentration measurements for collection during test. The contaminant monitoring system consists of an analytical real time gas analyzer, a carbon monoxide sensor, and an analyzer for ammonia and water vapor.

Broerman, Craig D.↗

Features of Afterbody Radiative Heating for Jupiter Entry

In this extended abstract, a preliminary analysis of a trajectory-based heating and ablation study in the afterbody of a Jovian entry probe is presented. The radiative flux in the afterbody impinging on the backshell of the probe is investigated with and without the presence of ablation product gas. The heritage tangent-slab approximation for radiative heating is shown to underpredict the radiative heating by as much as 50% in the afterbody making the highfidelity, yet computationally expensive, ray-tracing approach necessary to accurately predict the radiative heating predictions. An investigation into the merits of employing the ray-tracing approach for the prediction of the divergence of radiative flux in the afterbody flow field will be presented in the final manuscript. Nonequilibrium effects in the afterbody region will be investigated in the final manuscript including the impact of electron-ion recombination rates. To bound the problem based on the best available knowledge, an uncertainty analysis will be performed. Sources of uncertainty are identified in the ablation modeling, radiation modeling, flowfield kinetics, and thermodynamic properties of select species.

Thermophysics↗

Solar-metallicity gas in the extended halo of a galaxy at z ∼ 0.12

ABSTRACT We present the detection and analysis of a weak low-ionization absorber at z = 0.121 22 along the sightline of the blazar PG 1424+240, using spectroscopic data from both HST/COS and STIS. The absorber is a weak Mg ii analogue, with an incidence of weak C ii and Si ii, along with multicomponent C iv and O vi. The low ions are tracing a dense (nH ∼ 10−3 cm−3) parsec-scale cloud of solar or higher metallicity. The kinematically coincident higher ions are either from a more diffuse (nH ∼ 10−5–10−4 cm−3) photoionized phase of kiloparsec-scale dimensions or are tracing a warm (T ∼ 2 × 105 K) collisionally ionized transition temperature plasma layer. The absorber resides in a galaxy overdense region, with 18 luminous (>L*) galaxies within a projected radius of 5 Mpc and velocity of 750 km s−1. The multiphase properties, high metallicity, and proximity to a 1.4L* galaxy, at ρ ∼ 200 kpc and separation |Δv| = 11 km s−1, favour the possibility of the absorption tracing circumgalactic gas. The absorber serves as an example of weak Mg ii–O vi systems as a means to study multiphase high-velocity clouds in external galaxies.

Pradeep, Jayadev↗

Compound Specific Hydrogen Isotope Composition of Type II and III Kerogen Extracted by Pyrolysis-GC-MS-IRMS

The use of Hydrogen (H) isotopes in understanding oil and gas resource plays is in its infancy. Described here is a technique for H isotope analysis of organic compounds pyrolyzed from oil and gas shale-derived kerogen. Application of this technique will progress our understanding. This work complements that of Pernia et al. (2013, this meeting) by providing a novel method for the H isotope analysis of specific compounds in the characterization of kerogen extracted by analytically diverse techniques. Hydrogen isotope analyses were carried out entirely "on-line" utilizing a CDS 5000 Pyroprobe connected to a Thermo Trace GC Ultra interfaced with a Thermo MAT 253 IRMS. Also, a split of GC-separated products was sent to a DSQ II quadrupole MS to make semi-quantitative compositional measurements of the extracted compounds. Kerogen samples from five different basins (type II and III) were dehydrated (heated to 80 C overnight in vacuum) and analyzed for their H isotope compositions by Pyrolysis-GC-MS-TC-IRMS. This technique takes pyrolysis products separated via GC and reacts them in a high temperature conversion furnace (1450 C) which quantitatively forms H2, following a modified method of Burgoyne and Hayes, (1998, Anal. Chem., 70, 5136-5141). Samples ranging from approximately 0.5 to 1.0mg in size, were pyrolyzed at 800 C for 30s. Compounds were separated on a Poraplot Q GC column. Hydrogen isotope data from all kerogen samples typically show enrichment in D from low to high molecular weight compounds. Water (H2O) average deltaD = -215.2 (V-SMOW), ranging from -271.8 for the Marcellus Shale to -51.9 for the Polish Shale. Higher molecular weight compounds like toluene (C7H8) have an average deltaD of -89.7 0/00, ranging from -156.0 for the Barnett Shale to -50.0 for the Monterey Shale. We interpret these data as representative of potential H isotope exchange between hydrocarbons and sediment pore water during formation within each basin. Since hydrocarbon H isotopes readily exchange with water, these data may provide some useful information on gas-water or oil-water interaction in resource plays, and further as a possible indicator of paleo-environmental conditions. Alternatively, our data may be an indication of H isotope exchange with water and/or acid during the kerogen isolation process. Either of these interpretations will prove useful when deciphering H isotope data derived from kerogen analysis. More experiments are planned to discern these two or other possible scenarios.

Socki, Richard A.↗

Cross-correlation of Dark Energy Survey Year 3 lensing data with ACT and P l a n c k thermal Sunyaev-Zel’dovich effect observations. II. Modeling and constraints on halo pressure profiles

Hot, ionized gas leaves an imprint on the cosmic microwave background via the thermal Sunyaev-Zel’dovich (tSZ) effect. The cross-correlation of gravitational lensing (which traces the projected mass) with the tSZ effect (which traces the projected gas pressure) is a powerful probe of the thermal state of ionized baryons throughout the Universe and is sensitive to effects such as baryonic feedback. In a companion paper (Gatti et al. Phys. Rev. D 105, 123525 (2022)), we present tomographic measurements and validation tests of the cross-correlation between Galaxy shear measurements from the first three years of observations of the Dark Energy Survey and tSZ measurements from a combination of Atacama Cosmology Telescope and Planck observations. In this work, we use the same measurements to constrain models for the pressure profiles of halos across a wide range of halo mass and redshift. We find evidence for reduced pressure in low-mass halos, consistent with predictions for the effects of feedback from active Galactic nuclei. We infer the hydrostatic mass bias (B ≡ M 500c /M SZ from our measurements, finding B = 1.8 ± 0.1 when adopting the Planck-preferred cosmological parameters. We additionally find that our measurements are consistent with a nonzero redshift evolution of B, with the correct sign and sufficient magnitude to explain the mass bias necessary to reconcile cluster count measurements with the Planck-preferred cosmology. Our analysis introduces a model for the impact of intrinsic alignments (IAs) of galaxy shapes on the shear-tSZ correlation. We show that IA can have a significant impact on these correlations at current noise levels.

79 ASTRONOMY AND ASTROPHYSICS↗

Plutonium Signatures in Molten-Salt Reactor Off-Gas Tank and Safeguards Considerations

Fluid-fueled molten-salt reactors (MSRs) are actively being developed by several companies, with plans to deploy them internationally. The current IAEA inspection tools are largely incompatible with the unique design features of liquid fuel MSRs (e.g., the complex fuel chemistry, circulating fuel inventory, bulk accountancy, and high radiation environment). For these reasons, safeguards for MSRs are seen as challenging and require the development of new techniques. This paper proposes one such technique through the observation of the reactor’s off-gas. Any reactor design using low-enriched uranium will build up plutonium as the fuel undergoes burnup. Plutonium has different fission product yields than uranium. Therefore, a shift in fission product production is expected with fuel evolution. The passive removal of certain gaseous fission products to the off-gas tank of an MSR provides a valuable opportunity for analysis without significant modifications to the design of the system. Uniquely, due to the gaseous nature of the isotopes, beta particle emissions are available for observation. The ratios of these fission product isotopes can, thus, be traced back to the relative amount and types of fissile isotopes in the core. This proposed technique represents an effective safeguards tool for bulk accountancy which, while avoiding being onerous, could be used in concert with other techniques to meet the IAEA’s timeliness goals for the detection of a diversion.

Dunkle, Nicholas (ORCID:000000027323011X)↗

Hydrocarbons identified in extracts from estuarine water accommodated no. 2 fuel oil by gas chromatography-mass spectrometry

Results are presented on a computerized gas chromatograph-mass spectrometer analysis of methylene chloride and n-heptane extracts of a No. 2 fuel oil accommodated estuarine water sample. The analytical method is briefly described, and the limitations on the identifications are categorized. Some attempt was made to determine major and trace constituents in the water accommodate. Altogether 66 hydrocarbon compounds were identified specifically, and 75 compounds were partially identified. Seven compounds could be recognized as major constituents of the water accommodated oil and ten were present only as traces. The aromatic compounds found were alkyl benzenes, naphthalene, tetralin, indane, biphenyl, fluorene, anthracene, and some of their alkyl substituted isomers in the range of carbon numbers C7 to C15. Four n-alkanes, C10 to C13, were found along with four other assorted hydrocarbons.

Lewis, B. W.↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

MicroResonators for Compacts Optical Sensors (μRCOS)

As the demand for continuous, in-situ surveillance of health of systems and environments rapidly increases, miniaturized sensors with fast responses are sought. Optical dielectric resonators supporting Whispering Gallery Modes (WGMs) have exceptional properties, like very high-power density, very narrow spectral linewidth, and extremely small mode volume. As the footprint of these sensors is drastically reduced, measurements of microvolumes samples with dramatic reduction in analysis time are possible, enabling large numbers of parallel analyses using microarrays. The high sensitivity and speed of WGM resonators combined with the ability to detect molecules in their native state have great future potential for basic and applied research such as reliable single molecule, trace-gas detection, environmental monitoring, chemical threat sensing, and biodefense Such appealing peculiarities motivated us developing WMG resonators (WGMRs) for Cavity Enhanced Absorption Spectroscopy (CEAS) for chem-bio detection. Specifically, we designed and batch-fabricated microspheres and fiber tapers for resonances excitation. We successfully detected gases (N 2 and CO 2 ) in customized environmental chambers, and bio-organisms (Inf. A and E. Coli) with integrated microfluidic systems. Background calibration and environmental isolation were always accounted for in proving the performances.

36 MATERIALS SCIENCE↗

Advances in PSP Testing in LaRC High Reynolds Number Facilities

The use of luminescent coatings for the global measurement of surface aerodynamic properties at full-flight Reynolds numbers has been ongoing at the NASA Langley Research Center since the late 1990s, beginning with Temperature Sensitive Paint (TSP) for boundary layer analysis at the 0.3-m Transonic Cryogenics Tunnel. Since then, significant work has been made to extend these measurements to pressure using Pressure Sensitive Paint (PSP) as well as develop systems for application in larger scale, full-flight Reynolds number facilities, such as the National Transonic Facility (NTF). Recently, a system for the measurement of time-resolved pressure using recently developed unsteady PSP (uPSP) formulations has been designed and implemented in the Transonic Dynamics Tunnel (TDT). The use of PSP (or uPSP) in either of these large scale, full-fight Reynolds number wind tunnels is complicated by the fact that both facilities operate best in oxygen deficient environments; however, the PSP technique relies on the presence of oxygen to work. The NTF is typically operated in cryogenic conditions, which is achieved using liquid nitrogen. In this facility, temperatures can reach as low as 116 K (-250 °F) with nominal oxygen concentrations of less than 50 ppm. This has resulted in the development of specialized PSP formulations that can operate in the cryogenic environment with the introduction of low amounts of oxygen (typically less than 2000 ppm) for PSP response. Likewise, to achieve full-flight Reynolds number conditions in the TDT, the atmosphere in the tunnel is replaced with a “heavy gas” of R-134A (1,1,1,2-tetrafluoroethane), which also has minimal oxygen native in the flow. The use of uPSP in this case will also depend on the introduction of trace amounts of oxygen, with the precise concentrations to be determined in an upcoming test. This presentation will describe some recent advancements that have been made for PSP measurements in both facilities. For the NTF system, there has been significant development of enhanced lighting for use at cryogenic conditions, as well as improvements in the application efficiency of the PSP. Furthermore, there are efforts underway to incorporate advanced data analysis techniques to acquire additional surface aerodynamic properties using the PSP technique that can yield not only improved experimental efficiency, but also provide data needed for next generation vehicle design and development. For the uPSP system in TDT, significant efforts to improve the data transfer rates to a high-performance computing environment for analysis are underway and performance and initial results from the system in the heavy-gas environment will be presented.

Pressure Sensitive Paint↗

Chemical studies of H chondrites. III - Regolith evolution of the Fayetteville chondrite parent

Radiochemical neutron concentration analysis was used to determine Ag, Au, Bi, Cd, Co, Cs, Ga, In, Rb, Sb, Se, Te, Tl, and Zn contents in consortium samples of solar gas and track-rich dark matrix. Data obtained confirmed that the matrix is chemically homogeneous. Most dark clasts had similar mean trace element concentrations as the matrix but were compositionally much more heterogeneous. It is concluded that material incorporated with soil and compacted to form the dark portion of Fayetteville included soil-melt, the odd C2M fragment, and dark and light clasts which escaped comminution.

Xiao, Xiaoyue↗

Aerosols and Particulates Workshop Sampling Procedures and Venues Working Group Summary

The Sampling Procedures and Venues Workgroup discussed the potential venues available and issues associated with obtaining measurements. Some of the issues included Incoming Air Quality, Sampling Locations, Probes and Sample Systems. The following is a summary of the discussion of the issues and venues. The influence of inlet air to the measurement of exhaust species, especially trace chemical species, must be considered. Analysis procedures for current engine exhaust emissions regulatory measurements require adjustments for air inlet humidity. As a matter of course in scientific investigations, it is recommended that "background" measurements for any species, particulate or chemical, be performed during inlet air flow before initiation of combustion, if possible, and during the engine test period as feasible and practical. For current regulatory measurements, this would be equivalent to setting the "zero" level for conventional gas analyzers. As a minimum, it is recommended that measurements of the humidity and particulates in the incoming air be taken at the start and end of each test run. Additional measurement points taken during the run are desirable if they can be practically obtained. It was felt that the presence of trace gases in the incoming air is not a significant problem. However, investigators should consider the ambient levels and influences of local air pollution for species of interest. Desired measurement locations depend upon the investigation requirements. A complete investigation of phenomenology of particulate formation and growth requires measurements at a number of locations both within the engine and in the exhaust field downstream of the nozzle exit plane. Desirable locations for both extractive and in situ measurements include: (1) Combustion Zone (Multiple axial locations); (2) Combustor Exit (Multiple radial locations for annular combustors); (3) Turbine Stage (Inlet and exit of the stage); (4) Exit Nozzle (Multiple axial locations downstream of the nozzle). Actual locations with potential for extractive or non-intrusive measurements depend upon the test article and test configuration. Committee members expressed the importance of making investigators aware of various ports that could allow access to various stages of the existing engines. Port locations are engine si)ecific and might allow extractive sampling or innovative hybrid optical-probe access. The turbine stage region was one the most desirable locations for obtaining samples and might be accessed through boroscope ports available in some engine designs. Discussions of probes and sampling systems quickly identified issues dependent on particular measurement quantities. With general consensus, the group recommends SAE procedures for measurements and data analyses of currently regulated exhaust species (CO2, CO, THC, NO(x),) using conventional gas sampling techniques. Special procedures following sound scientific practices must be developed as required for species and/or measurement conditions not covered by SAE standards. Several issues arose concerning short lived radicals and highly reactive species. For conventional sampling, there are concerns of perturbing the sample during extraction, line losses, line-wall reactions, and chemical reactions during the sample transport to the analyzers. Sample lines coated with quartz.or other materials should be investigated for minimization of such effects. The group advocates the development of innovative probe techniques and non-intrusive optical techniques for measurement of short lived radicals and highly reactive species that cannot be sampled accurately otherwise. Two innovative probe concepts were discussed. One concept uses specially designed probes to transfer optical beams to and from a region of flow inaccessible by traditional ports or windows. The probe can perturb the flow field but must have a negligible impact on the region to be optically sampled. Such probes are referred to as hybrid probes and are under development at AEDC for measurement in the high pressure, high temperature of a combustor under development for power generation. The other concept consists of coupling an instrument directly to the probe. The probe would isolate a representative sample stream, freeze chemical reactions and direct the sample into the analyzer portion of the probe. Thus, the measurement would be performed in situ without sample line losses due either to reactions or binding at the wall surfaces. This concept was used to develop a fast, in situ, time-of-flight mass spectrometer measurement system for temporal quantification of NO in the IMPULSE facility at AEDC. Additional work is required in this area to determine the best probe and sampling technique for each species measurement requirement identified by the Trace Chemistry Working Group. A partial list of Venues was used as a baseline for discussion. Additional venues were added to the list and the list was broken out into the following categories: (1)Engines (a) Sea Level Test Stands (b) Altitude Chambers; (2) Annular Combustor Test Stands, (3) Sector Flametube Test Stands, (4) Fundamentals Rigs/Experiments.

Pachlhofer, Peter↗

High temperature UF6 and plasma research

Research currently under way on technology for uranium plasma core reactors is reviewed. A feeder system to provide a controlled and steady flow of UF6 at rates up to 5 g/sec and temperatures up to 500 K into rf plasma test chambers operating at pressures of up to 20 atm has been developed. Plasma emission and dye laser absorption measurements have been used to estimate the radial distribution of uranium atom number density within the plasma. X-ray absorption equipment and techniques have also been employed to measure the amount of uranium in the plasma, and dc plasma torch experiments have shown variations in plasma VUV emission with temperature. Analysis of residues deposited on various test-chamber components after plasma tests reveals traces of several uranium oxides, including UO2F2, and various exhaust duct configurations with flow augmentation are under investigation as means of preventing uranium deposition. Other areas of research include off- and on-line exhaust gas diagnostics, and a UF6/Ar injection, separation and recirculation system.

Roman, W. C.↗

A gas chromatograph experiment for a Titan entry probe

Development of a gas chromatographic technique for analysis of aerosols and volatile organics from a Titan probe is now in progress. Preliminary investigations of aerosol collectors have shown that an electrostatic device should be the most efficient for the particle sizes expected in Titan's atmosphere. Such a device particularly lends itself to development of a simple pyrolyzer which can be used to break down any collected organic conglomerate structures into volatile fragments. Those fragments can subsequently be analyzed by GC providing information about the original chemical structure of the aerosols. Studies show that as little as 1 to 5 micrograms of model aerosol can be successfully analyzed. High altitude atmospheric gas sampling will also be important on Titan due to the great depth of the atmosphere. Studies show that a GC analysis of model Titan atmospheres at pressures approximating this altitude can be made with a sensitivity of a few ten's of parts-per-billion for the trace gases of interest.

Carle, G. C.↗

Mid-Infrared Observations of the Galactic Center

Under this grant, Susan Stolovy completed her thesis work and performed an analysis of the galactic center. For her thesis Susan analyzed observations of the galactic center obtained with the KAO using the KEGS spectrograph, built at Cornell. These observations present a study of the distribution and kinematics of the atomic gas in the inner few parsecs of the Galaxy as traced by the forbidden [SiII] line at 34.814 microns. The integrated [SiII] emission peaks near Sgr A* and extends past the inner edge of the Circumnuclear Disk (CND), passing through a gap in the dense molecular material to the northwest. The [SiII] maps have a spatial resolution of 15" and a spectral resolution of 50 km/s. The spectra, which are characterized by broad linewidths of order 100 km/s, are kinematically consistent with the CND rotation to the southwest but not to the north. The northern extension may be experiencing shocks and is likely to be infalling along the Northern Arm. Observations of high [Sill]/ [OI] and [SiII]/dust continuum ratios support the conjecture that turbulent motions and shocks in the inner few parsecs of the Galaxy are destroying dust grains, thus elevating the abundance of atomic silicon.

Stolovy, Susan↗