Development of COTS ADC SEE Test System for the ATLAS LArCalorimeter Upgrade

Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272 is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Radiation Test Results on a 22FDX Test Vehicle

Total ionizing dose irradiations were performed on a 22 nm fully-depleted silicon-on-insulator static random access memory. There is a strong well-bias effect in the TID response. Combined TID and SEE results are also presented.

total ionizing dose↗

Recent Radiation Test Results on a 22FDX Test Vehicle

Total ionizing dose irradiations were performed on a 22 nm fully-depleted silicon-on-insulator static random access memory. There is a strong well-bias effect in the TID response. Combined TID and SEE results are also presented.

total ionizing dose↗

Ionizing Radiation Effects on Hole Collection Backside-Illuminated P-Type Deep-Trench Pinned Photo-MOS Pixels under Image Acquisition

Dark current degradation, origins, and annealing behavior after x-ray irradiation are studied in a P-type, hole collecting, backside-illuminated image sensor currently being developed at STMicroelectronics and based on deep-trenched photo-MOS pixels. Different biasing conditions during irradiation, i.e. grounded or biased and sequenced, are compared. The dark current increase with total ionizing dose (TID) and the dark current annealing behavior seem to be driven by the backside interface between the P-epitaxy of the pixels and the ONO stack. Despite still being under development, this pixel architecture already exhibits both very good electro-optical performance and a better radiation hardness than pinned photodiode-based CMOS Image sensors that benefit from the same advanced CIS processing technologies. At high total dose range, the photogate challenges custom Radiation-Hardened-by-Design photodiodes by exhibiting a comparable radiation tolerance while bringing new features such as high-resolution or Correlated Double Sampling.

CMOS Image Sensor (CIS)↗

How Long Can the Hubble Space Telescope Operate Reliably?

Total ionizing dose exposure of electronic parts in the Hubble Space Telescope is analyzed using 3-D ray trace and Monte Carlo simulations. Results are discussed along with other potential failure mechanisms for science operations.

Mechanical Structure↗

A Confidence-Based Approach to Including Survivors in a Probabilistic TID Failure Assessment

A probabilistic total ionizing dose (TID) failure assessment is extended to include survivor data, enabling the bounding of failure probability to a desired confidence level (CL) without failure data. The extension provides an avenue for analyzing microelectronics tested for TID without reaching a failure mode, a scenario often encountered by missions utilizing commercial-off-the-shelf (COTS) technologies. Using the type-I censored likelihood formulation and a realistic upper bound on expected device performance, the failure probability space is bounded by confidence contours within the context of a variable environment. The framework accommodates any type of distribution assumed for the part failure or the environment under consideration. Furthermore, the framework can be utilized pre-emptively to plan future device TID tests, minimizing costs while meeting survival requirements. Heritage data may also be used as survivors to further minimize testing costs when parts are from the same lot, but the amount of constraint derived from heritage is limited. Altogether, the framework enables a formal, mathematically rigorous analysis of radiation tolerant devices tested to a maximum dose, as well as flight heritage, in a hardness assurance methodology.

confidence↗

Terrestrial Sources of X-Ray Radiation and Their Effects on NASA Flight Hardware

X-rays are an energetic and penetrating form of ionizing electromagnetic radiation, which can degrade NASA flight hardware. The main concern posed by such radiation is degradation of active electronic devices and, in some cases, diodes. Non-electronic components are only damaged at doses that far exceed the point where any electronic device would be destroyed. For the purposes of this document, flight hardware can be taken to mean an entire instrument, the flight electronics within the instrument or the individual microelectronic devices in the flight electronics. This document will discuss and describe the ways in which NASA flight hardware might be exposed to x-rays, what is and isn't a concern, and how to tell the difference. First, we must understand what components in flight hardware may be vulnerable to degradation or failure as a result of being exposed to ionizing radiation, such as x-rays. As stated above, bulk materials (structural metals, plastics, etc.) are generally only affected by ionizing radiation at very high dose levels. Likewise, passive electronic components (e.g. resistors, capacitors, most diodes) are strongly resistant to exposure to x-rays, except at very high doses. The main concerns arise when active components, that is, components like discrete transistors and microelectronic devices, are exposed to ionizing radiation. Active components are designed to respond to minute changes in currents and voltages in the circuit. As such, it is not surprising that exposure to ionizing radiation, which creates ionized and therefore electrically active particles, may degrade the way the hardware performs. For the most part, the mechanism for this degradation is trapping of the charges generated by ionizing radiation by defects in dielectric materials in the hardware. As such, the degree of damage is a function of both the quantity of ionizing radiation exposure and the physical characteristics of the hardware itself. The metric that describes the level of exposure to ionizing radiation is total ionizing dose (TID). The unit of TID is the rad, which is defined as 100 ergs absorbed per gram of material. Dose can be expressed in other units, for example grays (gy), where 1 gy = 100 rads. The actual fluence of radiation needed to deliver a rad depends on the absorbing material, so units of dose are usually stated in reference to the material of interest. That is, for microelectronic devices, the unit of dose is generally rad (Si) or rad (SiO2). However, the definition of absorbed dose in this fashion has the advantage that the type of radiation causing the ionization can be normalized so that a realistic and adequate comparison can be made. The sensitivity of microelectronic parts to TID varies over many orders of magnitude. (Note: Doses to humans are typically expressed in rems-or roentgen-equivalent-man-which measures tissue damage, and depends on the type of radiation, as well as the dose in rads.) Thus far, the "softest" parts tested at NASA showed damage at 500 rads (Si), while parts that are radiation-hardened by design can remain functional to doses on the order of 107 rads (Si). This broad range of sensitivity highlights one of the most important considerations when considering the effects of radiation on electronic parts: In order to determine whether a radiation exposure is a concern for a particular part, one must understand the technologies used in the part and their vulnerabilities to TID damage. A NASA radiation expert should be consulted to obtain such information.

X-ray↗

Evaluation of an Accelerated ELDRS Test Using Molecular Hydrogen

An accelerated total ionizing dose (TID) hardness assurance test for enhanced low dose rate sensitive (ELDRS) bipolar linear circuits, using high dose rate tests on parts that have been exposed to molecular hydrogen, has been proposed and demonstrated on several ELDRS part types. In this study several radiation-hardened "ELDRS-free" part types have been tested using this same approach to see if the test is overly conservative.

radiation effects↗

NASA Goddard Space Flight Center’s Recent Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single-Event Effects (SEE)↗

Thermal Radiometer Signal Processing Using Radiation Hard CMOS Application Specific Integrated Circuits for Use in Harsh Planetary Environments

Thermal radiometers such as proposed for the Europa Clipper flyby mission require low noise signal processing for thermal imaging with immunity to Total Ionizing Dose (TID) and Single Event Latchup (SEL). Described is a second generation Multi- Channel Digitizer (MCD2G) Application Specific Integrated Circuit (ASIC) that accurately digitizes up to 40 thermopile pixels with greater than 50 Mrad (Si) immunity TID and 174 MeV-sq cm/mg SEL. The MCD2G ASIC uses Radiation Hardened By Design (RHBD) techniques with a 180 nm CMOS process node.

Focal Plane Assembly↗

NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FETs, flash memory, FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single Event Effects (SEE)↗

NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FETs, flash memory, FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single Event Effects (SEE)↗

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

A TID and SEE Characterization of Multi-Terabit COTS 3D NAND Flash

Single-event effects and total ionizing dose testing are described for a 32-layer NAND flash memory, in both SLC and MLC configurations, with special considerations for unique three-dimensional test results. Extraction of three-dimensional heavy-ion test data presents a unique visualization of angular effects in NAND flash. Pattern dependence differences between SLC and MLC mode are noted, along with slightly non-uniform angular cross-section results due to the complex volume. Finally, TID data under different operating and bias conditions shows that the failure point remains the higher-voltage erasure circuitry.

Flash Memory↗

Resources for Radiation Test Data

The performance of electronic devices in a space radiation environment is often limited by susceptibility to single-event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Interpreting the results of SEE, TID, and DD testing of complex devices is quite difficult given the rapidly changing nature of both technology and the related radiation issues. Radiation testing is performed to establish the sensitivities of candidate spacecraft electronics to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transients (SETs), TID, and DD effects. Knowing where to search for these test results is a valuable resource for the aerospace engineer or spacecraft design engineer. This poster is intended to be a resource tool for finding radiation test data.

Single Event Effects (SEE)↗

The Effect of Gamma Radiation Exposure on Active Silicon Photonic Device Performance Metrics

In this study, we test Si vertical junction disk modulators and waveguide-integrated Ge PIN photodiodes to see how the key performance metrics are affected by 60Co gamma radiation (total ionizing dose), a common proxy for simulating a mix of high energy ion particle flux. It is found that reverse bias dark current increases significantly for both devices after 1 Mrad(Si) exposure. Whereas the bandwidth of the Si disk modulator decreases by 6.5 % after 1 Mrad(Si) dose, the bandwidth of the Ge PIN photodiode appears to be unaffected. The increased sensitivity of the Si disk modulator bandwidth to gamma radiation is hypothesized to be caused by a decrease in the carrier concentration of the junction with a resulting increase in p-n junction RC time constant. The Ge PIN photodiode is relatively insensitive to the surface effects because the absorption happens away from the SiO2-Ge interface and the gamma radiation has a minimal effect on carrier mobility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗