Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration and Evaluation of Lightweight High Performance Quad-Pane Windows

Ten high-performance quad-pane windows (five quad-pane with suspended film and five quad-pane with thin glass) were installed at Building 41 of the Denver Federal Center in Colorado as part of a demonstration project to assess their thermal performance, life cycle costs, and deployment potential for replacing older single-pane windows. The U.S. Department of Energy's National Renewable Energy Laboratory performed several different evaluations to assess the viability of the quad-pane windows for GSA applications. Some of these assessments were performed with models, while others required onsite evaluations including time series measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A multiphysics model of the versatile test reactor based on the MOOSE framework

The traditional modeling approach for sodium fast reactor cores relies on separate physics models, where the fuel performance, thermal–hydraulics, and neutronics calculations required to predict the core physics characteristics for nominal conditions are decoupled by relying on user-imposed boundary conditions. Here, this paper aims at evaluating the impact of multiphysics simulations for predicting the core characteristics of the Versatile Test Reactor, which is being designed as a 300-MWt sodium-cooled fast reactor. The purpose of the Versatile Test Reactor is to accelerate the testing of advanced nuclear materials in the United States. The proposed multiphysics model relies on the Griffin reactor physics code, the SAM thermal–hydraulic system code, the BISON fuel performance code, as well as generic Multiphysics Object-Oriented Simulation Environment capabilities implemented in the open-source tensor mechanics module. For k eff calculations, the introduction of a tight coupling between the neutronics, thermo-mechanical and thermal–hydraulics models induces a change of around 543 pcm in the eigenvalue, compared to the traditional standalone neutronics calculation where approximate temperature profiles are used. The multiphysics model is then employed for quantifying the impact of the thermal conductivity uncertainties on some of the key figures of merit, such as the fuel centerline temperature, assembly powers, and keff for nominal core conditions. As anticipated, uncertainties on fuel thermal conductivity mostly impact the fuel centerline temperature, and to a lesser extend the k eff .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (DEMO-FTES) [Abstract]

Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.

25 ENERGY STORAGE↗

Numerical study to predict the effect of surface roughness on the thermal and hydraulic performance of additively manufactured heat exchangers

Heat exchangers are used in many industries to transfer thermal energy between two or more objects with an associated thermal and hydraulic performance indicated by thermal effectiveness and pressure drop respectively. Many investigations have aimed to enhance the thermal effectiveness of heat exchangers by introducing turbulent flow inducers that increase the heat transfer rate at the expense of increasing pressure drop. Flow inducers like surface roughness can be controlled with advanced manufacturing methods like additive manufacturing for heat exchanger production. Selecting and manufacturing an optimal surface roughness for heat exchangers requires a more comprehensive approach that accounts for the surface roughness effect on the thermal and hydraulic performance of a sample. Since fabricating samples with additive manufacturing to a desired surface roughness can be an extensive experimental process, this study will fundamentally investigate the effect of surface roughness on the thermal and velocity boundary layers for various surface roughness profiles with physics-based computational modeling. To accurately model the surface roughness effect on thermohydraulic performance, correlations like roughness ratio, friction factor, and Nusselt number are investigated. This study expects to indicate correlations for different flow regimes which can successfully predict the effect of surface roughness on thermohydraulic performance. Results generated from modeling surface roughness effect with unique correlations are then compared to experimental data obtained from literature for validation. The results of this study will provide insight to understand the thermal fluid physics associated with surface roughness and design guidelines for heat exchangers produced with additive manufacturing.

36 MATERIALS SCIENCE↗

Designing Cellular Metal Structures for Thermal Insulation

This project focused on developing topology optimization software to design advanced metal thermal insulators. Initially, solid designs were created that matched the thermal performance of current baseline designs but were significantly heavier. To address this, cellular materials were incorporated, specifically the octet structure which is known for its high strength-to-weight ratio and thermal properties. By leveraging these cellular designs at various densities, superior thermal and mechanical performance was achieved without added weight. This novel approach enhances thermal management and structural integrity under extreme conditions, offering promising advancements for thermal protection systems.

36 MATERIALS SCIENCE↗

Self-Healing Films for Vacuum Insulation Panels (Final Report)

Vacuum insulation panels (VIPs) have an extremely high thermal resistance of around R35/inch, which makes them ideal for building envelope retrofits and prefabricated construction with space constraints. However, the barrier film that maintains the vacuum and thermal performance of the panel can be easily damaged during transportation, installation, and service life. Oak Ridge National Laboratory (ORNL) has developed a self-healable barrier film for VIPs that instantly self-heals damages caused by punctures. The multi-layer barrier film is manufactured using roll-to-roll (R2R) methods. The self-healing barrier film prevents loss of vacuum in VIPs and maintains the exceptional thermal insulation performance. Enhanced durability of VIP by self-healable barrier film and establishing the commercialization path will increase the use of VIPs, thus reducing overall energy usage of buildings. This project has fine-tuned the slurry chemistry of the self-healing components and transitioned the R2R manufacturing trials from mid-scale lab equipment to large-scale industrial equipment for de-risking the technology for commercialization with our TCF CRADA partner, FLEXcon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Insulated Wall Systems with Exterior Insulation of Polyisocyanurate under Different Facer Materials: Material Characterization and Long-Term Hygrothermal Performance Assessment

The application of exterior insulation in both new construction and retrofits is a common practice to enhance the energy efficiency of buildings. In addition to increased thermal performance, the rigid insulation can serve to keep the sheathing board warm and serve as a water-resistive barrier to keep moisture-related problems due to condensation and wind-driven rain. Polyisocyanurate (PIR) rigid boards have a higher thermal resistance in comparison to other commonly used exterior insulation boards. However, because of its perceived lower permeance, its use as exterior insulation is not very common. In this study, the hygrothermal property of PIR boards with different facer types and thicknesses is characterized. The material data obtained through experimental test and extrapolation is used in a long term hygrothermal performance assessment of a wood frame wall with PIR boards as exterior insulation. Results show that PIR with no facer has the smallest accumulated moisture on the sheathing board in comparison to other insulation boards. Walls with a bigger thickness of exterior insulation perform better when no vapor barrier is used. The PIR exterior insulation supports the moisture control strategy well in colder climates in perfect wall scenarios, where there is no air leakage and moisture intrusion. In cases where there is trapped moisture, the sheathing board has a higher moisture content with PIR boards with both aluminum or fiberglass type facers. An innovative facer material development for PIR boards can help efforts targeting improved energy-efficient and durable wall systems.

36 MATERIALS SCIENCE↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Numerical and Experimental Study of a Novel Additively Manufactured Metal-Polymer Composite Heat-Exchanger for Liquid Cooling Electronics

In order to meet increasing power-dissipation requirements of the electronics industry, compact, low-cost, and lightweight heat exchangers (HXs) are desired. With proper design, materials, and manufacture, polymer composite heat exchangers could meet these requirements. This paper presents a novel crossflow air-to-water, low-cost, and lightweight metal-polymer composite HX. This HX, which is entirely additively manufactured, utilizes a novel cross-media approach that provides direct heat exchange between air and liquid sides by using connecting fins. A robust numerical model was developed, which includes the dimensional effects of additive manufacturing. The study consists of a simplified 3D CFD model based on ellipsoidal-shaped staggered tube banks for the laminar range. It then uses an analytical approach to compute entire HX performance. The model is validated experimentally within 8% for thermal performance, 12% for air-side impedance, and 18% for water-side impedance. Finally, HX is compared with a conventional CPU radiator and performs within 10% of the conventional unit for reasonable flow rates and pressure-drop ranges. Moreover, HX also provides added design and cost advantages over the conventional unit, which makes the HX a potential candidate for electronic cooling applications.

30 DIRECT ENERGY CONVERSION↗

Using Models to Predict the Hygrothermal Performance of Equipment and Piping Insulation

The development of hygrothermal models began in earnest in the 1990s, with the initial emphasis on the performance of building envelope systems. Numerous large-scale building envelope failures associated with water intrusion drove this development. The physical principles of moisture transfer that apply to building envelopes are equally valid for equipment and piping insulation systems. The main advantage of modeling is that carefully characterized models can predict the long-term hygrothermal performance of any system under different climatic and interior conditions. Thermal insulations are commonly used on outdoor equipment and piping for different applications, such as thermal energy conservation and freeze protection. The insulated equipment usually experiences moisture intrusion due to many factors, such as the duration and frequency of moisture exposure, equipment operating temperature, insulation type, exposure temperature, weather conditions, equipment thermal cycling, and weatherproofing condition. Hygrothermal models have been employed to estimate the moisture pickup of insulated equipment and piping systems, as well as the moisture redistribution and subsequent change in thermal performance as these systems become contaminated with moisture. The hygrothermal model provides insights on the parameters influencing the time of wetness, the lateral redistribution of moisture along the pipe away from the leak, and the ease by which water escapes the insulation/jacketing systems. It has been shown that the moisture leak effect decreases rapidly with distance from the leak and that one- and two-dimensional hygrothermal simulations help to identify solutions to reduce conditions that support corrosion under insulation (CUI).

Shrestha, Som↗

High-temperature thermal conductivity measurements of macro-porous graphite

Graphite is a unique material for high temperature applications and will likely become increasingly important as we attempt to electrify industrial applications. Here, we investigate the thermal properties of low-quality, macro-porous graphite to determine the tradeoff between quality and thermal performance. We use laser flash analysis (LFA) to measure the thermal diffusivity of graphite at high temperatures. Due to the large pores in the graphite samples preventing uniform laser flash heating, we first apply a thick coating to achieve the required flat, parallel surfaces for LFA measurements. We then develop a methodology to extract properties of the sample from the diffusivity measurements, based on finite element modeling of a variety of sample/coating interface profiles. Validating the methodology against a reference sample demonstrates a mean absolute percentage error of 8.5%, with potential improvement with better sample characterization. We show low-quality graphite has a thermal conductivity of ~10 W/m/K up to 1000 °C, which is an order of magnitude lower than high-quality graphite, but contributions from photon conductivity may result in higher conductivities at higher temperatures. Overall, we demonstrate an approach for measuring thermal properties of macro-porous materials at high temperatures, and apply the approach to measuring thermal conductivity of porous graphite, which will aid in the design of hightemperature systems for cost-competitive decarbonization.

Verma, Shomik↗

The Octopus processor for the CMS L1 muon trigger for High Luminosity LHC

The upgraded L1 muon trigger system of the CMS experiment in the High Luminosity Large Hadron Collider is based on custom processors featuring large Field Programmable Gate Arrays (FPGAs) connected by large numbers of optical links. These provide the I/O bandwidth and power necessary to process the complex algorithms used during the collection of physics data. The design and performance requirements of these processors creates significant challenges in signal integrity, power delivery, and thermal management. In this paper we describe the Octopus processor, featuring a large Xilinx Virtex Ultrascale+ FPGA and up to 128 links interfaced to optics through high quality twin-ax copper cables. Results on signal integrity at 25 Gb/s and the first demonstration of 50+ Gb/s links with pluggable optics in CMS are also shown, demonstrating bit error rates below 10 –15 at a 95% confidence level. The thermal performance is measured inside an Advanced-TCA crate with acceptable thermal margins up to 200 W of chip power. Future improvements are mentioned, potentially allowing operation at up to 300 W.

Instruments & Instrumentation↗

Energy savings and life cycle cost analysis of advanced double skin facade system applied to old apartments in South Korea

South Korea is one of the most densely populated countries in the world, and the population density in urban areas is much higher among others. Apartments are the most common form of residential buildings due to their high population density. More than 60% of domestic residential buildings are apartments, with more than 10 million households. The high population density is a problem that has long plagued South Korea because more than 45% of apartments are old apartments that are more than 20 years old. Old apartment buildings have low thermal performance that results in lots of energy consumption. Balconies, which worked as a thermal buffer, are also being removed by residents to expand indoor space. According to the green remodeling project supported by the Korean government, the typical retrofitting method is replacing external windows with the high-efficiency window in old apartments in South Korea. Here, this paper proposes a retrofitting method using an extended double-skin façade (DSF) system that replaces exterior windows and acts as a thermal buffer. The simulation model is developed with the EnergyPlus simulation program to conduct energy performance analyses. The simulation model has been calibrated using actual experimental data collected between October 1, 2019, and January 15, 2020. Results show that the cooling, heating, and lighting energy can be reduced up to 44.1% by fully utilizing electric energy generated by solar PV panels integrated with the DSF system. The payback period is about 15 years based on the energy price provided by the utility company. Although the payback period is long, it has great potential of energy savings and CO 2 emission reductions. The DSF system should be considered as a way of renovation, considering other factors such as increased real estate values and energy cost increases in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of Insulated Metal Substrate-Based SiC Power Module for Traction Application

This paper presents the electrical characterization and drive cycle--based thermal analysis of an insulated metal substrate (IMS)--based silicon carbide power module for high-power traction inverters. The substrate was constructed using a thin layer of polymer--ceramic blend dielectric material with a thick copper core to improve transient thermal performance. The cooling performance of this module has already been validated with promising results. In this paper, an experimental test bed was set up to evaluate the dynamic and static electrical performance of the designed module under a wide range of operating conditions. The characterization results were then used to develop a drive cycle--based thermal model to validate the performance compared to the traditional direct bonded copper--based power module. The results indicate that the IMS-based power module is a suitable solution for high-power traction applications.

Chowdhury, Shajjad↗

Thermal energy storage composites with preformed expanded graphite matrix and paraffin wax for long-term cycling stability and tailored thermal properties

Harvesting solar energy, preventing hot spots in electronics, transport of temperature-sensitive materials, and capture and repurposing of thermal energy require a latent heat thermal energy storage (TES) system to store/discharge heat repeatedly. For the practical application of phase change material (PCM) composites within TES systems, reliable thermal performance throughout its operational lifetime is essential. Nevertheless, the reliability of thermal conductivity in multi-phase composites over relevant numbers (>10 3 ) of melt/freeze cycles has barely been studied, particularly for composites containing fillers for thermal conductivity enhancement. Here, we introduce a preform-type expanded graphite (EG)/paraffin wax composite possessing highly robust heat transfer and storage properties even after 10,000 melt/freeze cycles. To achieve such excellent reliability, comparative studies on the combined influence of fabrication process, particle size, EG vol%, binder amount, and compaction on both magnitude and robustness of thermal conductivity were undertaken. Our parametric study has yielded a trade-off between thermal conductivity and latent heat. Based on our modeling, 20 vol% EG approaches the case where all EG particles are well-connected thermally while 10 vol% EG is close to loosely connected fillers in the matrix. Thermal conductivity of our paraffin composites containing 20 vol% EG (25.1 W·m -1 ·K -1 ) is highest among other EG/paraffin composites without aligned EG in the literature. After 10,000 thermal cycling, negligible conductivity fading was observed for the 10 vol% EG composite, while reduction in latent heat remained within 10% for all 10, 14, 17 and 20 vol% EG samples. Here we anticipate this work provides insight on suitable recipe for desirable magnitude and robustness of thermal conductivity of EG/paraffin composites.

25 ENERGY STORAGE↗

Sizing comingled CF/PA 6 fibers with cellulose nanofibrils for enhanced performance properties

Compatibility between the reinforcing phase and the polymer matrix is critical to achieving the desired mechanical and thermal performance of composite materials. Several mechanisms can enhance this interfacial interaction, including surface treatments (e.g., oxidation, plasma, or irradiation), in-situ nanoparticle deposition, and fiber sizing. Here, in this study, cellulose nanofibrils (CNF) were employed as a sustainable sizing agent to modify the interface in commingled carbon fiber (CF)/polyamide 6 (PA 6) yarns, in which CF and PA6 filaments are intimately blended to enable simultaneous consolidation. A 0.25 wt% CNF aqueous suspension was applied under bath sonication to ensure uniform dispersion and minimize agglomeration. CNF-sized and unsized yarns were used to fabricate unidirectional composite plates via filament winding on a flat mandrel, followed by compression molding. Scanning electron microscopy confirmed CNF presence on both CF and PA6 filaments. CNF-sized composites exhibited increments in interlaminar shear strength (ILSS) by 50%, flexural strength by 11%, and tensile strength by 2.5% compared to unsized composites. Thermal analysis showed minimal changes in degradation temperature and crystallinity. These findings demonstrate that CNF sizing enhances interfacial bonding and mechanical performance, offering a scalable and environmentally friendly strategy for thermoplastic composite manufacturing along with yarn/tow handleability.

Cellulose nanofibrils (CNF)↗