TRISO PARTICLE FUEL PERFORMANCE WITH BISON
This is a deck of slide to be presented to the 6th Workshop on Material Properties of TRISO Fuels October 19-20, 2022.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This is a deck of slide to be presented to the 6th Workshop on Material Properties of TRISO Fuels October 19-20, 2022.
The investigation of the TRISO coated particles is important in terms of verification the quality of the nuclear fuel samples before placing them in the reactor core. To determine the degree of damage to the coated particles, the samples must be properly polished in order to uncover the inner layers. The poster presents a comparison of two polishing methods. Mechanical polishing method, which is used frequently for sample preparations generates additional mechanical damages in the studied fuel particle, thus directly affecting the experimental results. Due to that, a novel way to polish the samples is presented - an ionic polishing method. Based on the obtained results, it was concluded that the ion polishing method is better because the level of interference with the structures of the individual layers of the tested samples is much lower than with the mechanical method.
Four post-irradiation heating tests of fuel compacts from the U.S. Advanced Gas Reactor (AGR)-3/4 irradiation experiment were completed. In addition to tristructural isotropic (TRISO)-coated driver fuel, each compact contained designed-to-fail (DTF) particles with fuel kernels coated only in pyrocarbon so as to simulate exposed kernels. Tests at 1600/1700°C, 1400°C, and 1200°C were performed to measure fission product release as a function of time and temperature. Silver release was highest in the 1200°C test, supporting the observation that silver release rates are highest in the 1100–1300°C range. Compared to tests of AGR-1 compacts with no exposed kernels, the Cs-134 and Kr-85 releases were noticeably higher in AGR-3/4. The exposed kernels’ contributions to Eu and Sr release are inconclusive, due to the difficulty in distinguishing among the combined effects of higher irradiation temperatures in these particular AGR-3/4 compacts, the presence of the DTF particles, and the Fuel Accident Condition Simulator (FACS) test temperatures. These data can be used to make inferences about fission product retention in exposed kernels as a function of time and temperature.
To assess whether matrix fracture would result in an unacceptable loss of containment or confinement in TRISO fuel particles, it is crucial to evaluate the micro-tensile strength, fracture toughness, and irradiation effects on matrix materials. Current data must be comprehensive and validated for modeling fractures under various conditions. Relevant material properties surrounding matrix fracture will be discussed during the presentation.
No abstract, annual program review. Name of presentation is "Correlative Atom Probe Tomography of the Buffer-IPyC Interlayer Region of TRISO-coated Particles." While APT and TEM data were collected, they were collected separately and not correlatively as originally planned. APT and TEM data are paired with micro-tensile data from the same regions.
To address the lack of data on the behavior of short-lived fission products I-131 (t1/2 = 8.02 d) and Xe-133 (t1/2 = 5.24 d) in the TRISO fuel system, loose AGR-2 particles and kernels were reirradiated in NRAD and subjected to post-reirradiation heating in the FACS furnace. This provided data on the release of fission products from exposed kernels, and the results were used to establish FACS condensation plate collection efficiencies for temperatures of 1000, 1200, and 1400°C where previously, the only collection efficiencies were for 1600°C tests. These new collection efficiencies were then applied to the NRAD-FACS tests of entire AGR-3/4 fuel compacts. Understanding the relative behavior of short-lived I-131, for example, is important because it is a significant contributor to offsite dose during postulated accidents, and Xe-133 has previously been used as a conservative indicator of I-131 behavior. These data will be used to support refinement of fission product transport models and HTGR source-term analyses.
A refined BISON-Griffin workflow for designing targeted TRISO transient analyses in the Transient Reactor Test Facility
Micro-tensile characterization of AGR-2 TRISO Particle Layers and Interlayer Regions, including experimental motivation, results, irradiated fuel kernel APT, Buffer, SiC omparison, conclusion, and future work.
Thermophysical Property Characterization of Irradiated TRISO Compacts to include motivation, experiment background, TCM Experimental Method, TCM Results, Summary, and future work.
Thermophysical Property Characterization of Irradiated TRISO Compacts to include motivation, experiment background, TCM Experimental Method, TCM Results, Summary, and future work.
Presentation on TRISO Fuel development and qualification status to be given at the Advanced Reactor Technologies (ART) annual program review.
NEAMS/AGR BISON modeling of TRISO updates
TRISO transient testing studies and future plans
Laser-induced breakdown spectroscopy (LIBS) mapping enables rapid elemental and spatial analysis of solid samples. In this work, surrogate TRi-structural ISOtropic (TRISO) particles with various layers consisting of Zr, W, C, and Si were used to demonstrate the use of a new thickness measurement tool developed to analyze elemental images generated from LIBS maps. Zr particles with varying outer-layer thicknesses ranging from 16 to 32 μm were measured with scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) and LIBS with both a complementary metal-oxide-semiconductor (CMOS) detector and an intensified charged coupled device (ICCD) detector. LIBS maps of particles were completed using CMOS and ICCD spectrometers with effective spatial resolutions of 4 and 2 μm, respectively. The novel thickness measurement tool identified layer regions within a LIBS map and then identified the locations of the boundaries between these layers. The tool then generated up to 1000 random profiles stemming radially from the center region, which were used to measure the layer thickness/radius. This image analysis tool demonstrated LIBS's ability to provide values comparable with SEM-EDS (3.7% relative difference) along with a 95% reduction in measurement time. Furthermore, the precision of these measurements was on par with the SEM-EDS measurements at <15% relative standard deviation. Following the analysis of the Zr particles, W particles with increased complexity (e.g., five versus three layers) were analyzed using both the CMOS and ICCD spectrometers simultaneously. The spatial dimensions were extracted with an average relative difference of 2.7% and an average relative standard deviation of 9%.
TRISO (TRi-structural ISOtropic) – compact-type micro-particle fuels – are next generation nuclear fuel compacts designed with safety in mind. Structural integrity and characterisation before and after irradiation are important to determine the performance of the fuel compacts under real reactor conditions. X-ray computed tomography can be an important tool for non-destructive evaluation of these fuel compacts. The fuel particles are highly attenuating for X-rays which creates metal artefact, rendering the images unusable. Our artefact correction can mitigate these artefacts significantly. The proposed method works by first segmenting highly-attenuating structures (metal) and forward projecting to localise the source of artefacts in the projection domain, then, using a traditional or U-net-based deep learning architecture, contextually interpolating those regions to remove the artefacts. Finally the reconstruction from the modified projection is fused with the segmented metal. The proposed method shows a significant improvement in the image quality while significantly reducing the reconstruction time compared to the standard technique.
The three-dimensional (3D) characterization of nuclear fuel with X-ray microscopy has historically proven difficult, due to uranium’s high attenuation of easily accessible X-rays, both in a laboratory setting and at a synchrotron user facility. However, this imaging modality provides nondestructive information that can be used to investigate morphological changes arising from external stimuli (e.g., neutron irradiation, high-temperature testing). Using an appropriate X-ray energy spectrum and an adequate X-ray filter, suitable transmissions through properly sized nuclear fuel specimens can be achieved. Here, in this study, we present the methods and results of using a commercially available, laboratory-based X-ray microscope (XRM) to examine the extent of 3D morphological changes of tristructural isotropic (TRISO)-coated fuel particles, specifically uranium oxide/uranium carbide fuel kernels, after high-temperature neutron irradiation.
A furnace system was developed to thermally expose individual tristructural-isotropic (TRISO) coated particles to expand upon established postirradiation examination (PIE) safety testing that is used to explore particle failures and fission product release from compacts. Two systems were installed in the Irradiated Fuels Examination Facility (IFEL) at Oak Ridge National Laboratory (ORNL). The targeted design was intended to be simple and flexible to allow a range in conditions to be explored. Initial inert atmosphere testing indicated the presence of particle failures, so modifications to the testing approach were implemented to improve the furnace operation. Ultimately, burnback particles were analyzed to provide a direct measurement of fission product release, thus avoiding the complications from integral release that were observed during whole compact testing. Particles were exposed to temperatures ranging 1,150–1,300°C for up to 1,500 h and 1,600°C up to 500 h. No indication of uniform release of fission products such as 106 Ru, 125 Sb, or 154 Eu was observed, however, indication of particle dependent 154 Eu release was suggested for select particles. Exploration of 110m Ag release was limited to 1,150°C and 1,300°C up to 500 h. The analysis indicated that there was nonuniform release of 110m Ag and supports a possible bimodal temperature dependence on silver release.
MiniFuel compacts containing 20 individual tristructural isotropic (TRISO)-coated fuel particles were characterized to provide supporting preirradiation characterization data. The preirradiated characterization data supports irradiation capsule design and safety analysis, as well as downstream postirradiation examination (PIE) for a planned MiniFuel irradiation to explore high particle powers. The analysis included dimensional inspection, x-ray radiography and tomography, as-fabricated defect fraction analysis, and a matrix impurity analysis.