Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TREATMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-E-T-219: Comprehensive Validation of the Electron Monte Carlo Dose Calculation Algorithm in RayStation Treatment Planning System for An Elekta Linear Accelerator with AgilityTM Treatment Head

Purpose: This study evaluated the performance of the electron Monte Carlo dose calculation algorithm in RayStation v4.0 for an Elekta machine with Agility™ treatment head. Methods: The machine has five electron energies (6–8 MeV) and five applicators (6×6 to 25×25 cm {sup 2}). The dose (cGy/MU at d{sub max}), depth dose and profiles were measured in water using an electron diode at 100 cm SSD for nine square fields ≥2×2 cm{sup 2} and four complex fields at normal incidence, and a 14×14 cm{sup 2} field at 15° and 30° incidence. The dose was also measured for three square fields ≥4×4 cm{sup 2} at 98, 105 and 110 cm SSD. Using selected energies, the EBT3 radiochromic film was used for dose measurements in slab-shaped inhomogeneous phantoms and a breast phantom with surface curvature. The measured and calculated doses were analyzed using a gamma criterion of 3%/3 mm. Results: The calculated and measured doses varied by <3% for 116 of the 120 points, and <5% for the 4×4 cm{sup 2} field at 110 cm SSD at 9–18 MeV. The gamma analysis comparing the 105 pairs of in-water isodoses passed by >98.1%. The planar doses measured from films placed at 0.5 cm below a lung/tissue layer (12 MeV) and 1.0 cm below a bone/air layer (15 MeV) showed excellent agreement with calculations, with gamma passing by 99.9% and 98.5%, respectively. At the breast-tissue interface, the gamma passing rate is >98.8% at 12–18 MeV. The film results directly validated the accuracy of MU calculation and spatial dose distribution in presence of tissue inhomogeneity and surface curvature - situations challenging for simpler pencil-beam algorithms. Conclusion: The electron Monte Carlo algorithm in RayStation v4.0 is fully validated for clinical use for the Elekta Agility™ machine. The comprehensive validation included small fields, complex fields, oblique beams, extended distance, tissue inhomogeneity and surface curvature.

60 APPLIED LIFE SCIENCES↗

Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment

Purpose: To quantitatively assess the advantages of energy-layer specific dynamic collimation system (DCS) versus a per-field fixed aperture for spot scanning proton therapy (SSPT). Methods: Five brain cancer patients previously planned and treated with SSPT were replanned using an in-house treatment planning system capable of modeling collimated and uncollimated proton beamlets. The uncollimated plans, which served as a baseline for comparison, reproduced the target coverage and organ-at-risk sparing of the clinically delivered plans. The collimator opening for the fixed aperture-based plans was determined from the combined cross sections of the target in the beam’s eye view over all energy layers which included an additional margin equivalent to the maximum beamlet displacement for the respective energy of that energy layer. The DCS-based plans were created by selecting appropriate collimator positions for each row of beam spots during a Raster-style scanning pattern which were optimized to maximize the dose contributions to the target and limited the dose delivered to adjacent normal tissue. Results: The reduction of mean dose to normal tissue adjacent to the target, as defined by a 10 mm ring surrounding the target, averaged 13.65% (range: 11.8%–16.9%) and 5.18% (2.9%–7.1%) for the DCS and fixed aperture plans, respectively. The conformity index, as defined by the ratio of the volume of the 50% isodose line to the target volume, yielded an average improvement of 21.35% (19.4%–22.6%) and 8.38% (4.7%–12.0%) for the DCS and fixed aperture plans, respectively. Conclusions: The ability of the DCS to provide collimation to each energy layer yielded better conformity in comparison to fixed aperture plans.

60 APPLIED LIFE SCIENCES↗

SU-F-T-365: Clinical Commissioning of the Monaco Treatment Planning System for the Novalis Tx to Deliver VMAT, SRS and SBRT Treatments

Purpose: To commission the Monaco Treatment Planning System for the Novalis Tx machine. Methods: The commissioning of Monte-Carlo (MC), Collapsed Cone (CC) and electron Monte-Carlo (eMC) beam models was performed through a series of measurements and calculations in medium and in water. In medium measurements relied Octavius 4D QA system with the 1000 SRS detector array for field sizes less than 4 cm × 4 cm and the 1500 detector array for larger field sizes. Heterogeneity corrections were validated using a custom built phantom. Prior to clinical implementation, an end to end testing of a Prostate and H&N VMAT plans was performed. Results: Using a 0.5% uncertainty and 2 mm grid sizes, Tables I and II summarize the MC validation at 6 MV and 18 MV in both medium and water. Tables III and IV show similar comparisons for CC. Using the custom heterogeneity phantom setup of Figure 1 and IGRT guidance summarized in Figure 2, Table V lists the percent pass rate for a 2%, 2 mm gamma criteria at 6 and 18 MV for both MC and CC. The relationship between MC calculations settings of uncertainty and grid size and the gamma passing rate for a prostate and H&N case is shown in Table VI. Table VII lists the results of the eMC calculations compared to measured data for clinically available applicators and Table VIII for small field cutouts. Conclusion: MU calculations using MC are highly sensitive to uncertainty and grid size settings. The difference can be of the order of several per cents. MC is superior to CC for small fields and when using heterogeneity corrections, regardless of field size, making it more suitable for SRS, SBRT and VMAT deliveries. eMC showed good agreement with measurements down to 2 cm − 2 cm field size.

60 APPLIED LIFE SCIENCES↗

Nanofiltration Treatment Options for Thermoelectric Power Plant Water Treatment Demands

Nanofiltration (NF) can effectively treat both cooling-tower water and coal-bed methane (CBM) produced waters. NF is an attractive option over conventional reverse osmosis because it requires less power and is less likely to scale. Nanofiltration could help in minimizing water consumption and maximize water usage efficiency of thermoelectric power plants. The power plants could increase the cycles of water recirculation through cooling towers and/or used treated impaired waters. The NF system effectively removed scaling components from cooling-tower recirculating water with an efficiency of > 99% for divalent ions, 78% - 95.8% for monovalent ions and almost 90% for silica and from CBM produced water with efficiency greater than 95% for most constituents including silica. In most cases the NF system worked better than predicted by the ROSA™, a manufacturer’s desalination software used to design systems and predict how well they will work. Theoretical calculations determined that the total volume of water discharged from cooling towers can be reduced by as much as 75% using the continuous NF process compared to traditional recirculating cooling-tower operation. The total volume of water needed for make up could be reduced by as much as 25%. The cost for NF of cooling-tower water is estimated to be $\$$0.50 – $\$$0.90 per per 1,000 gallons. Before the successful use of a NF system in a cooling tower with similar chemistry of this pilot study, the system and pretreatment system must be designed carefully to control scaling in NF unit. In addition, NF treatment of CBM produced water will likely require a pretreatment system to control parafilms, filming agents, iron flocs, coal fines, and biological growth.

Altman, Susan Jeanne↗

Waste Treatment Technology Process Development Plan For Hanford Waste Treatment Plant Low Activity Waste Recycle

The purpose of this Process Development Plan is to summarize the objectives and plans for the technology development activities for an alternative path for disposition of the recycle stream that will be generated in the Hanford Waste Treatment Plant Low Activity Waste (LAW) vitrification facility (LAW Recycle). This plan covers the first phase of the development activities. The baseline plan for disposition of this stream is to recycle it to the WTP Pretreatment Facility, where it will be concentrated by evaporation and returned to the LAW vitrification facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Annual Update Pantex Plant Site Treatment Plan/Compliance Plan for Development of Mixed Waste Treatment Capacities and Technologies

This updated STP identifies how DOE proposes to obtain commercial treatment or as appropriate, develop technologies for the site's mixed waste in inventory that does not currently have a developed disposition path. This updated STP also provides the methodology to be implemented if mixed waste is generate or identified that requires development of a disposition path.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of NASA Dual Microstructure Heat Treatment Method for Multiple Forging Batch Heat Treatment

NASA dual microstructure heat treatment technology previously demonstrated on single forging heat treat batches of a generic disk shape was successfully demonstrated on a multiple disk batch of a production shape component. A group of four Rolls-Royce Corporation 3rd Stage AE2100 forgings produced from alloy ME209 were successfully dual microstructure heat treated as a single heat treat batch. The forgings responded uniformly as evidenced by part-to-part consistent thermocouple recordings and resultant macrostructures, and from ultrasonic examination. Multiple disk DMHT processing offers a low cost alternative to other published dual microstructure processing techniques.

Gayda, John↗

Designing a New Radioactive Liquid Waste Treatment Facility for Los Alamos National Laboratory to Update Treatment Technologies and Meet Current Regulatory Requirements

This paper discusses the new Radioactive Liquid Waste Treatment Facility (RLWTF) being designed for Los Alamos National Laboratory (LANL) and also provides information regarding the updates to the facility resulting from improvements in technologies and changes in regulations and codes that have occurred since the existing facility was built. It explains how the new facility will be a suitable replacement for the existing facility and how the new facility will allow LANL to continue its current mission as well as have the capability to treat any new waste stream resulting from a future expansion of the laboratory. Specific topics relating to the improvements in technology that are discussed include replacing existing settling technologies with improved chemical precipitation technologies using hydrochloric acid, sodium hydroxide, magnesium chloride, and ferric chloride. Also discussed are improved filtration technologies and dewatering technologies. Topics discussed regarding regulatory and code requirements include the current state and federal regulatory criteria and the new seismic criteria requirements that the design conforms to. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvement and protection of niobium surface superconductivity by atomic layer deposition and heat treatment

A method to treat the surface of Nb is described, which potentially can improve the performance of superconducting rf cavities. We present tunneling and x-ray photoemission spectroscopy measurements at the surface of cavity-grade niobium samples coated with a 3 nm alumina overlayer deposited by atomic layer deposition. The coated samples baked in ultrahigh vacuum at low temperature degraded superconducting surface. However, at temperatures above 450 C, the tunneling conductance curves show significant improvements in the superconducting density of states compared with untreated surfaces.

43 PARTICLE ACCELERATORS↗

Harnessing Photoelectrochemistry for Wastewater Nitrate Treatment Coupled with Resource Recovery

Wastewater is a misplaced resource well suited to recover nutrients, value-added chemicals, energy, and clean water. A photoelectrochemical device is proposed to transform wastewater nitrates to ammonia and nitrous oxide, coupled with water oxidation. Numerical models were developed to quantify the dependence of process efficiencies and nitrogen-removal rates on light absorber band gaps, electrocatalytic kinetic parameters, competing oxygen reduction and hydrogen evolution reactions, and the reacting nitrate species concentrations that affect the mass-transfer limited current densities. With a single light-absorber and state-of-the-art catalysts, optimal solar-to-chemical efficiencies of 7% and 10% and nitrogen-removal rates of 260 and 395 gN m -2 day -1 are predicted for nitrate reduction to ammonia and nitrous oxide, respectively. The influence of competing reactions on the performance depends on the nitrate concentration and band gap of the light absorber modeled. Oxygen reduction is more dominant than hydrogen evolution to compete with the nitrate reduction reaction, but it is mass-transfer limited. Even with kinetic parameters that enhanced the driving forces for the competing reactions, the performance is only minimally affected by these reactions for optimally selected band gaps and nitrate concentrations larger than 100 mM. Here, theoretically predicted peak nitrogen removal rates and specific energy intensities are competitive with reported estimates for electrochemical and Sharon-Anammox processes for ammonia recovery and nitrogen removal, respectively. This result, together with the added benefit of harnessing sunlight to produce value-added products, indicates promise in the photoelectrochemical approach as a tertiary pathway to recover nutrients and energy from wastewater nitrates.

25 ENERGY STORAGE↗

A History of Hanford Tank Waste, Implications for Waste Treatment and Disposal

More than 40 years of plutonium processing have left almost 56 million gallons of mixed radioactive waste sequestered in 177 underground tanks on the Hanford Site. Three different processing technologies were employed for plutonium purification in addition to uranium scavenging and fission product removal from the tank waste. All of these chemical processes have contributed to a complex waste stream that varies from tank to tank that presents downstream processing challenges to render the waste into a safe form for long-term storage. The current disposition pathway for Hanford tank waste is vitrification. To maximize waste loading and minimize the number of high-level waste canisters stored in a geologic repository, pretreatment of the waste is required. Both pretreatment and vitrification operations are impacted by the waste composition.

Separations, filtration, ion exchange↗