Status of h-BN quasi-bulk crystals and high efficiency neutron detectors

III-nitrides have fomented a revolution in the lighting industry and are poised to make a huge impact in the field of power electronics. In the III-nitride family, the crystal growth and use of hexagonal BN (h-BN) as an ultrawide bandgap (UWBG) semiconductor are much less developed. Bulk crystals of h-BN produced by the high-temperature/high-pressure and the metal flux solution methods possess very high crystalline and optical qualities but are impractical to serve as substrates or for device implementation as their sizes are typically in millimeters. The development of crystal growth technologies for producing thick epitaxial films (or quasi-bulk or semi-bulk crystals) in large wafer sizes with high crystalline quality is a prerequisite for utilizing h-BN as an UWBG electronic material. Compared to traditional III-nitrides, BN has another unique application as solid-state neutron detectors, which however, also require the development of quasi-bulk crystals to provide high detection efficiencies because the theoretical efficiency (ηi) relates to the detector thickness (d) by ηi=1−e−dλ, where λ denotes the thermal neutron absorption length which is 47 μm (237 μm) for 10B-enriched (natural) h-BN. We provide an overview and recent progress toward the development of h-BN quasi-bulk crystals via hydride vapor phase epitaxy (HVPE) growth and the attainment of thermal neutron detectors based on 100 μm thick 10B-enriched h-BN with a record efficiency of 60%. The thermal neutron detection efficiency was shown to enhance at elevated temperatures. Benchmarking the crystalline and optical qualities of h-BN quasi-bulk crystals with the state-of-the-art mm-sized bulk crystal flakes and 0.5 μm thick epitaxial films identified that reducing the density of native defects such as vacancies remains the most critical task for h-BN quasi-bulk crystal growth by HVPE.

Physics↗

High-Fidelity Multiphysics Assessment of the Molten Chloride Reactor Experiment (MCRE) Integrating Neutronics, Thermal-hydraulics and Thermochemistry

This work presents a MOOSE-based Multiphysics model of the LOTUS MSR reactor system. The model includes the coarse-mesh turbulent thermal-hydraulics including passive advection of delayed neutron precursors of the primary system through Pronghorn, the power density and neutronics calculation employing Griffin, and the chemical interactions through Gibbs energy minimization and redox potential with Thermochimica. Incorporating a plate-out model, the full multi-physics model is used to evaluate the effects of deposition and removal of solid compounds formed in the molten salt in the reactor surfaces, evaluating the concentrations and regions in which nickel, chromium and iron would be deposited. Results indicate an almost isothermal state of the fuel during operation at 25 kW that do not increase the plate-out effects due to low temperature gradients.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Probing and controlling oxygen impurity diffusion in h -BN semi-bulk crystals

Combining its unique features of ultrawide bandgap (UWBG) and two-dimensional nature, h-BN has been explored for emerging applications such as deep ultraviolet optoelectronic devices and single photon emitters. One of the unusual applications of h-BN is for solid-state neutron detectors by utilizing the property of high thermal neutron capture cross section of B-10 as well as its UWBG properties. Although a record high detection efficiency of 59% has been attained by h-BN detectors, the understanding/minimization of defects and impurities is still needed to further advance the h-BN material and detector technologies. We report metal organic chemical vapor deposition growth and oxygen (O) impurity diffusion in thick h-BN. The diffusion coefficient (D) of O impurities has been measured via the evolution of an oxygen related emission with the etching depth, providing a value of D of ∼ 2 × 10−13 cm2/s at 1450 °C and supporting the interpretation that oxygen in h-BN is a substitutional donor. A multiple-buffer-layer approach was employed to mitigate to a certain degree the issue of oxygen diffusion from sapphire substrate during growth. It was demonstrated that the performance of h-BN neutron detectors fabricated from the wafer incorporating multiple buffer layers was significantly improved, as manifested by the enhanced thermal neutron detection efficiency. The advancement of the crystal growth technology of h-BN semi-bulk crystals creates applications in optoelectronic and power electronic devices utilizing the UWBG semiconductor properties of h-BN, while high efficiency h-BN neutron detectors have the potential to supplant the traditional He-3 gas detectors in various application areas by offering the obvious advantages of UWBG semiconductor technologies.

Physics↗

Development of integrated neutronics and thermal analysis capabilities to support design and optimization of fusion engineering demonstration facility systems and blanket design (Final Scientific/Technical Report)

A fusion engineering demonstration facility would be the first step in the commercial fusion plant developmental pathway that aims to be an engineering demonstration of tritium self- sufficiency. One of the primary requirements for tritium self-sufficiency, as well as to ensure low plant tritium release to the external environment, is to minimize the tritium loss through the internal components, which requires accurate predictions of the tritium behavior for a wide range of materials and system conditions. This grant addressed the lack of a comprehensive model which accounts for particular conditions, such as the significance of temperature fields and neutronics information, and the systematic uncertainty quantification of associated material properties that impact tritium generation, utilization, and loss mechanisms in the blanket.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Coupled Neutronic and Thermal Hydraulic Analysis of a Natural Circulation Based Small Modular Reactor (SMR) Using VERA-CS

As part of the work supported by a US Department of Energy (DOE) Office of Nuclear Energy Gateway for Accelerated Innovation in Nuclear FY 2020 Voucher, Holtec International subsidiary SMR LLC (hereinafter referred to as Holtec) and Oak Ridge National Laboratory entered into a cooperative research and development agreement (CRADA) to develop coupled multiphysics core models of the Holtec developed small modular reactor (SMR), SMR-160. The scope of the 1 year project was to use the DOE–developed tool set, VERA, to analyze several aspects of a representative SMR-160 core design. The goals of the project were to perform the code-to-code benchmarking and to provide Holtec with a confirmatory calculations to compare against the results with the codes used in the SMR-160 design, identify and resolve areas of discrepancy between the two models to give Holtec a basis for selecting certain tool and model options, and develop a workflow so that the VERA model could be adapted easily to any future changes in the design of the SMR-160 core. The work proceeded in four phases: 1. Developing the initial VERA model based on Holtec-provided core design information; 2. Comparing VERA results with Holtec-provided calculations for the first five cycles; 3. Developing a VERA transient model based on the prior model; and 4. Training Holtec personnel on VERA and hand-off the developed models. This report summarizes at a high level the completed tasks. Details of the tasks and results are reserved for the full report, which will not be publicly released for 5 years per the terms of the CRADA. The report is titled “Coupled Neutronic and Thermal Hydraulic Analysis of a Natural Circulation Based Small Modular Reactor (SMR) using VERA-CS” and has the ORNL technical report number ORNL/TM 2021/2303 (NFE-20-08305)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Validation of Thermal Scattering Evaluations

In order to test the performance of new neutron thermal scattering law (TSL) evaluations it is desirable to have experimental data that is highly sensitive to the TSL and provides high fidelity information on the energy dependent performance of TSL evaluations. Three relevant experiments are discussed including: accurate thermal total cross section measurements, thermal neutron die-away experiments, and neutron leakage experiments. The experimental setups and results are reviewed, and examples provided for some moderators including polyethylene, Plexiglas, and YHx. For the experiments preformed thus far, there is generally good agreement between the measured total cross section and simulations using current TSL evaluations, however in certain energy ranges differences were observed. Similarly, neutron die-away and leakage measurements for samples at room temperature are in good agreement with data computed from TSLs, however leakage measurements for polyethylene at 29K show discrepancies with TSL evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal scattering law for ice based on neutron time-of-flight experiments carried out at the SEQUOIA spectrometer at the Oak Ridge National Laboratory

Precise estimation of neutron thermalization in moderators relies on high-fidelity thermal scattering cross-section data governed by the thermal scattering law (TSL). The Institut de Radioprotection et de Sûreté Nucléaire (IRSN) has been working on the development of improved TSL for light water ice. Many polymorphic phases of light water ice exist depending on the thermodynamic conditions. The most common type of ice at standard pressure and temperature below water freezing point (273.15 K) is ice-Ih. It is essential to have high-resolution experimental double differential data for developing and/or validating TSL for moderator materials.Existing experimental double-differential scattering data for ice-Ih are extremely sparse and of limited quality. New high-quality double-differential measurements for ice-Ih over multiple temperatures and incident neutron energies would directly support the validation and improvement of ice-Ih TSL models for criticality safety applications.Series of time-of-flight (TOF) inelastic neutron scattering experiments on ice-Ih at temperatures starting at 271 K and down to 6 K, have been carried out at the SEQUOIA spectrometer at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), United States. The experiments have been performed for incident neutron energies, Ei= 11, 55, 160, 250, and 600 meV, to explore different excitation energies in the vibrational phonon spectrum. This paper presents the thermodynamic conditions and the details of the TOF measurements on ice-Ih and the derived phonon spectrum from the experimentally measured double differential data. A study of the variation of the phonon spectrum of ice-Ih as a function of temperature is highlighted, and a preliminary TSL evaluation is developed based on the experimental phonon spectrum.

Jaiswal, V↗

IER 501: Pulsed Neutron Die-Away Experiments at LLNL [Slides]

This presentation notes the purpose of Pulsed Neutron Die Away (PNDA) for Thermal Neutron Scattering Law (TSL) validation. PNDA for TSL validation does not require fissile material. It consists of simple target shapes and compositions and is only sensitive to absorption and scattering of target medium. Well conducted experiments have uncertainties of 0.1% - 0.5%. This presentation also covers Pulsed Neutron Die Away Experiments, while noting previous experiments such as the FY22 PNDA Experiments. The presentation concludes with FY23 benchmarking efforts and a timeline to FY24.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Science applications of the Mars Observer gamma ray spectrometer

The Mars Observer gamma ray spectrometer will return data related to the elemental composition of Mars. The instrument has both a gamma ray spectrometer and several neutron detectors. The gamma ray spectrometer will return a spectrum nominally every 20 s from Mars permitting a map of the elemental abundances to be made. The gamma rays are emitted from nuclei involved in radioactive decay, from nuclei formed by capture of a thermal neutron, and from nuclei put in an excited state by a fast-neutron interaction. The gamma rays come from an average depth of the order of a few tens of centimeters. The spectrum will show sharp emission lines whose intensity determines the concentration of the element and whose energy identifies the element. The neutron detectors, using the fact that the orbital velocity of the Mars Observer spacecraft is similar to the velocity of thermal neutrons, determine both the thermal and epithermal neutron flux. By combining the results from both techniques it is possible to map the depth dependence of hydrogen in the upper meter as well. These data permit a variety of Martian geoscience problems to be addressed including the crust and mantle composition, weathering processes, volcanism, and the volatile reservoirs and processes.

Boynton, W. V.↗

Microstructure Evolution of U–Zr System in A Thermal Cycling Neutron Diffraction Experiment: Extruded U–10Zr (wt. %)

Microstructure evolution of 1073 K extruded U–10Zr (wt. %) fuel during thermal cycling (303–1073 K with a ~9 hour hold at 873 K during cooling) was investigated using in situ neutron diffraction. Analysis was performed using Rietveld texture and crystal structure refinements from time–of–flight neutron diffraction data, with a focus on the evolution of textures and lattice parameters as a function of temperature. The α–U phase exhibits lattice contraction with increasing temperature along the b lattice direction and lattice expansion in the other directions while the other phases exhibit lattice expansion with temperature in all directions. Contrary to the established phase diagram, the β–U phase is absent at the temperatures of the thermal cycling. (001) α and (110) γ plane normals are observed with a strong preferred orientation along the extrusion direction. Finally, the variant selection of (001) α ||(110) γ is observed for the first time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Generation of localized reactor point kinetics parameters using coupled neutronic and thermal fluid models for pebble-bed reactor transient analysis

The systems analysis of anticipated operating occurrences and design basis accidents for pebble-bed reactor systems requires knowledge of neutron point kinetics equations (PKE) parameters. Typically, the generation of PKE parameters is performed in a global manner using standalone neutronics calculations, without the inclusion of thermal fluid distributions. We utilize Griffin and Pronghorn for generating global and local PKE parameters which includes the use of thermal fluid distributions to account for localized effects. This work establishes a methodology for calculating PKE parameters for a pebble bed reactor with a coupled neutronics/thermal fluids analysis. PKE parameters generated on a global and local basis are compared against a diffusion solve for a typical load-following transient. Locally-generated neutron kinetic parameters are able to reduce the maximum error in the transient power level from 5% to below 1.5%; along with this, bulk temperature errors were reduced from 12 K to 4 K.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Review of Direct Neutron Conversion and Detection Processes

Commercial and laboratory neutron detection systems use indirect neutron response of materials like pressurized helium-3 (via nuclear reaction 3He(n, p)3H) to measure and count neutrons emanating from a source. Recently a host of semiconductors, especially a ternary semiconductor of lithium indium diselenide (6LiInSe2) and a quaternary alloy of enriched lithium-6, indium, phosphorous, and selenium (6LiInP2Se6), have shown promising neutron counting possibilities by directly converting neutrons into charge-carrying elements within the body of the semiconductor. These semiconductors have high thermal neutron capture cross sections, suitable energy bandgaps (~2.0 electron volts) for room-temperature operations, and a favorable electronic band structure for efficient electron charge transport. The article examines the semiconductor properties of these compounds in terms of their neutron counting capabilities and possible ways to extract neutron energy information from them. Lithium-6 and boron-10 (with thermal neutron absorption cross sections of 938 ± 6 and 3855 ± 26 barns, respectively) produce charged particles to be measured via indirect neutron interactions. The efficiency of indirect conversion neutron detectors is limited because of the inefficiencies in conversion mechanism. In case of direct conversion, the neutrons create charged particles in a single material for neutron capture and charge collection, increasing detection efficiency. Unlike 3He proportional counters, which provide no neutron energy information, the semiconductors can be used as neutron energy spectrometer. Fully resolved neutron energy by 6LiInP2Se6 from a plutonium-beryllium source has been reported in the literature. We will discuss the influence of these multilayered semiconductors’ crystallographic structures and growth techniques on neutron energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗