Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THALLIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SALTSTONE 3QCY09 TCLP RESULTS

A Saltstone waste form was prepared in the Savannah River National Laboratory (SRNL) from a Tank 50H sample and Z-Area premix material for the third quarter of calendar year 2009 (3QCY09). After the prescribed 28 day cure, samples of the saltstone were collected, and the waste form was shown to meet the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24 and R.61-79.268.48(a) requirements for a nonhazardous waste form with respect to RCRA metals and underlying hazardous constituents. These analyses met all quality assurance specifications of USEPA SW-846. The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the third quarter of the 2009 calendar year (3QCY09), Tank 50H accepted transfers of approximately 37 kgal from the Effluent Treatment Project (ETP) waste, approximately 5 kgal from Tank 710 - the H-Canyon General Purpose Evaporator, approximately 26 kgal from Tank 221H, approximately 319 kgal from the Modular Caustic Side Solvent Extraction Unit (MCU) Decontaminated Salt Solution Hold Tank (DSS-HT), and approximately 358 kgal from Tank 23H. The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (ISWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). Savannah River National Laboratory (SRNL) was asked to prepare saltstone from a sample of Tank 50H obtained August 5, 2009 during 3QCY09 to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&WTSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. B&WTSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SALTSTONE 3QCY09 TCLP RESULTS

A Saltstone waste form was prepared in the Savannah River National Laboratory (SRNL) from a Tank 50H sample and Z-Area premix material for the third quarter of calendar year 2009 (3QCY09). After the prescribed 28 day cure, samples of the saltstone were collected, and the waste form was shown to meet the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24 and R.61-79.268.48(a) requirements for a nonhazardous waste form with respect to RCRA metals and underlying hazardous constituents. These analyses met all quality assurance specifications of USEPA SW-846. The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the third quarter of the 2009 calendar year (3QCY09), Tank 50H accepted transfers of approximately 37 kgal from the Effluent Treatment Project (ETP) waste, approximately 5 kgal from Tank 710 - the H-Canyon General Purpose Evaporator, approximately 26 kgal from Tank 221H, approximately 319 kgal from the Modular Caustic Side Solvent Extraction Unit (MCU) Decontaminated Salt Solution Hold Tank (DSS-HT), and approximately 358 kgal from Tank 23H. The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (ISWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). Savannah River National Laboratory (SRNL) was asked to prepare saltstone from a sample of Tank 50H obtained August 5, 2009 during 3QCY09 to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&WTSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals-arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver-analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. B&WTSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SALTSTONE 1QCY10 TCLP RESULTS

The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the first quarter of the 2010 calendar year (1QCY10), Tank 50H accepted transfers of approximately 32 kgal from the Effluent Treatment Project (ETP), approximately 10 kgal from Tank 710 - the H-Canyon General Purpose Evaporator, approximately 32 kgal from the H-Canyon Super Kukla campaign, and approximately 26 kgal from the Modular Caustic Side Solvent Extraction Unit (MCU) Decontaminated Salt Solution Hold Tank (DSS-HT). The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (ISWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained January 8, 2010 during 1QCY10 to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

36 MATERIALS SCIENCE↗

SALTSTONE 2QCY10 TCLP RESULTS

The Saltstone Production Facility (SPF) receives waste from Tank 50H for treatment. In the second quarter of the 2010 calendar year (2QCY10), Tank 50H accepted transfers of approximately 19 kgal from the Effluent Treatment Project (ETP), approximately 5 kgal from Tank 710 - the H-Canyon General Purpose Evaporator, approximately 42 kgal from the HCanyon Super Kukla campaign, and approximately 73 kgal from the Modular Caustic Side Solvent Extraction Unit (MCU) Decontaminated Salt Solution Hold Tank (DSS-HT). The Saltstone Grout Sampling plan provides the South Carolina Department of Health and Environmental Control (SCDHEC) with the chemical and physical characterization strategy for the salt solution which is to be disposed of in the Z-Area Solid Waste Landfill (ISWLF). During operation, samples were collected from Tank 50H and grout samples prepared to determine the non-hazardous nature of the grout to meet the requirements of the South Carolina Hazardous Waste Management Regulations (SCHWMR) R.61-79.261.24(b) and R.61-79.268.48(a). Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained April 4, 2010 during 2QCY10 to determine the non-hazardous nature of the grout. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the UHCs benzene, phenols and total and amenable cyanide.

36 MATERIALS SCIENCE↗

Protracted oxygenation across the Cambrian–Ordovician transition: A key initiator of the Great Ordovician Biodiversification Event?

Fluctuations in marine oxygen concentrations have been invoked as a primary driver for changes in biodiversity throughout Earth history. Expansions in reducing marine conditions are commonly invoked as key causal mechanisms for mass extinctions, while increases in marine oxygenation are becoming an increasingly common causal mechanism invoked for biodiversification events. Here we utilize a multiproxy approach to constrain local and global marine paleoredox conditions throughout the late Cambrian–Early Ordovician from two drill core successions in Baltoscandia. Local paleoredox proxies such as manganese concentrations and iron speciation reveal that both sites in the Baltic paleobasin had persistently anoxic and predominantly euxinic (anoxic and sulfidic) bottom water conditions throughout the study interval. Corresponding trace metal datasets indicate nuanced contraction and expansion of global anoxic and euxinic conditions along continental margins during the late Cambrian–Early Ordovician. Lastly, thallium isotope data from these locally reducing sections suggest a global expansion of oxygenated shelf and deeper marine environments from the late Cambrian into the Early Ordovician. This evidence for increasingly oxic marine environments coincides with increases in burrowing depth and tiering in marine animals, as well as diversification of body fossils throughout this ~8-million-year interval. The collective geochemical datasets provide some of the first direct paleoredox evidence for an increase in marine oxygen concentrations as a key mechanism for the Ordovician radiation of marine life

anoxia↗

Calibration of the BaBar CsI(Tl) Calorimeter

After nine years of operation, the BABAR experiment at the e{sup +}e{sup -} B factory PEP-II (Standford Linear Accelerator Center) stopped data taking in April 2008. An important part of the experiment is the electromagnetic calorimeter which consists of 6580 CsI crystals doped with thallium and read out by Si-PIN photodiodes. The light yield of the CsI crystals is changing in time due to radiation exposure. In addition to the changing light yield, passive material in front of and between the crystals as well as signal thresholds during the reconstruction influence the reconstructed energies. This requires a time-dependent calibration of the calorimeter. The calibration issues are reviewed and the calibration results obtained from various data samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effectiveness of a dopant in U-Zr metallic fuel to prevent lanthanide migration

The advanced fast reactor concepts to achieve ultra-high burnup (about 50%) without requiring refueling by way of using metallic alloy fuel have gained interest. Fission product lanthanide accumulation at high burnup is substantial and its migration to cladding and reaction with cladding is a potential life-limiting phenomenon. As a means to solve this problem, adding an element that forms stable compounds with lanthanides to immobilize them has been proposed. The theoretical assessment shows that indium, thallium, gallium, and antimony are good candidates. Except for Sb, because these elements are low-melting temperature elements, liquid metal embrittlement of cladding is a concern if large sized agglomerates exist contacting the cladding. Alloy characterization of as-fabricated samples was performed to examine the effectiveness of the dopant addition method using optical microscopy and scanning electron microscopy. Although preliminary, the present results showed that indium is a better dopant to immobilize lanthanides.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis and oxidation catalysis of [tris(oxazolinyl)borato]cobalt(II) scorpionates

The reaction of CoCl 2 ·THF and thallium tris(4,4-dimethyl-2-oxazolinyl)phenylborate (TlTo M ) in tetrahydrofuran (THF) provides To M CoCl (1) in 95 % yield; however, appropriate solvents and starting materials are required to favor 1 over two other readily formed side-products, (To M ) 2 Co (2) and {HTo M }CoCl 2 (3). ESR, NMR, FTIR, and UV/Vis spectroscopies were used to distinguish these cobalt(II) products and probe their electronic and structural properties. Even after the structures indicated by these methods were confirmed by X-ray crystallography, the spectroscopic identification of trace contaminants in the material was challenging. The recognition of possible contaminants in the synthesis of To M CoCl in combination with the paramagnetic nature of these complexes provided impetus for the utilization of X-ray powder diffraction to measure the purity of the To M CoCl bulk sample. Furthermore, the X-ray powder diffraction results provide support for the bulk-phase purity of To M CoCl in preparations that avoid 2 and 3. Thus, 1 is a precursor for new [tris(oxazolinyl)borato]cobalt chemistry, as exemplified by its reactions with KOtBu and NaOAc to give To M CoOtBu (4) and To M CoOAc (5), respectively. Compound 5 is a catalyst for the oxidation of cyclohexane with meta-chloroperoxybenzoic acid (mCPBA), and the rate constants and selectivity for cyclohexanol versus cyclohexanone and ϵ-caprolactone were assessed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A flow-through gamma detection system for sub-surface radioxenon tracer measurements in LYNM PE1

A continuous flow-through, real-time radioxenon sensor array has been designed to monitor either 127 Xe or 133 Xe tracer gas as part of a series of underground chemical explosions in the Low-Yield Nuclear Monitoring (LYNM) Physics Experiment 1 (PE1). The sensors are pairs of shielded thallium-doped sodium iodide gamma-ray detectors that surround a gas measurement chamber. Each measurement chamber is connected to a sampling location in the geology surrounding the chemical explosion or in the access tunnel. The first experiment in the series, PE1 A, occurred in 2023 and the system quantified the 127 Xe tracer gas in the gas sampling lines for four weeks following the experiment execution. The array generated a set of radioxenon concentration time series with a 15-minute resolution that will be used to refine subsurface gas transport models.

Gamma-ray coincidence detection↗

Heterospin biradicals based on new piperidineoxyl-substituted 3,6-di-tert-butyl-o-benzoquinone

A nucleophilic addition reaction of 4-hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (OH-TEMPO) to 3,6-di-tert-butyl-o-benzoquinone was used to obtain a new sterically hindered o-benzoquinone (1) containing 2,2,6,6-tetramethylpiperidineoxyl functional group, which was characterized by IR spectroscopy, mass spectrometry, elemental analysis, and X-ray diffraction. A one-electron reduction of 1 with potassium and thallium is an efficient method for the generation of earlier unknown heterospin biradicals 5a and 5b, respectively, containing nitroxide and o-semiquinone radical centers. Analysis of the hyperfine structure of the ESR spectra of biradicals 5a and 5b in solution showed that they belong to the group of heterospin biradicals with strong (J >> a) and fast exchange interaction between the radical centers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of PbTe and SnTe as Ohmic Contact Layers in CdTe Solar Cell Devices

For solar cells based on CdTe, the choice of a suitable back contact material is limited by CdTe's deep work function. Here, we explored p-type PbTe and SnTe as ohmic contacts to CdTe. These contact layers were grown on single crystal CdTe substrates by molecular beam epitaxy, and the valence band offset between film and substrate was measured using X-ray photoemission spectroscopy. Polycrystalline device structures were also grown by sublimation to assess performance improvements. Doping was achieved in PbTe by thallium incorporation. Only the highest Tl doped PbTe resulted in a desirable band alignment with the CdTe, forming an electron reflector and no hole barrier. Time-resolved photoluminescence measurements also revealed significant photocarrier lifetime improvements for only the highest doped PbTe. Consequentially, devices incorporating the highest doped PbTe layers showed increased power conversion efficiency, primarily from increased fill factor. Doping of the PbTe was measured via Hall effect with variable magnetic field, which was required due to the formation of an n-type parasitic interface layer. To properly interpret the variable field Hall measurements, we derived an expression for the magnetic field-dependent conductivity tensor of an L-valley semiconductor.

anisotropic band valley↗

Monovalent metal phenylphosphonates and phenylarsonates: Single crystal X-ray structures of A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = K, Rb, Cs, Tl) and Na(HO{sub 3}AsPh)(H{sub 2}O{sub 3}AsPh) and methylamine intercalation of A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = Li, Na, K, Tl)

Single crystal X-ray structures of known A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = K, Rb, Cs, Tl) phenylphosphonates and sodium phenylarsonate, Na(HO{sub 3}AsPh)(H{sub 2}O{sub 3}AsPh) have been determined. This and previous studies together describe the four types of structures of a series of seven A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = Li, Na, K, Rb, Cs, Tl, NH{sub 4}) phenylphosphonates. Sodium phenylarsonate is isostructural with its phenylphosphonate analogue. A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = Li, Na, K and Tl) compounds undergo methylamine intercalation. - Graphical abstract: Amongst A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = alkali metal, Tl) phenylphosphonates of four structure types, lithium, sodium, potassium and thallium compounds undergo methylamine intercalation. - Highlights: • X-ray structures of A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = K, Rb, Cs, Tl) and Na(HO{sub 3}AsPh)(H{sub 2}O{sub 3}AsPh). • Four structure types of seven A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = monovalent ion) compounds. • Methylamine intercalation of A(HO{sub 3}PPh)(H{sub 2}O{sub 3}PPh) (A = Li, Na, K, Tl) compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗