Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TECHNETIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Resonance ionization mass spectrometry for isotopic abundance measurements

Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

Miller, C. M.↗

Therapeutic effects of antimotion sickness medications on the secondary symptoms of motion sickness

In addition to nausea and vomiting, motion sickness involves slowing of brain waves, loss of performance, inhibition of gastric motility and the Sopite Syndrome. The therapeutic effects of antimotion sickness drugs on these reactions were evaluated. The subjects were rotated to the M-III end-point of motion sickness. Intramuscular (IM) medications were then administered. Side effects before and after rotation were reported on the Cornell Medical Index. Brain waves were recorded on a Grass Model 6 Electroencephalograph (EEG), and gastric emptying was studied after an oral dose of 1 mCi Technetium 99m DTPA in 10 oz. isotonic saline. An increase in dizziness and drowsiness was reported with placebo after rotation. This was not prevented by IM scopolamine 0.1 mg or ephedrine 25 mg. EEG recordings indicated a slowing of alpha waves with some thea and delta waves from the frontal areas after rotation. IM ephedine and dimenhydrinate counteracted the slowing while 0.3 mg scopolamine had an additive effect. Alterations of performance on the pursuit meter correlated with the brain wave changes. Gastric emptying was restored by IM metoclopramide. Ephedrine IM but not scopolamine is effective for some of the secondary effects of motion sickness after it is established.

Wood, C. D.↗

Lunar and Planetary Science XXXV: Presolar Grains

Topics discussed include: Presolar Silicate Grains; Presolar Silicates from Primitivr Chondrites; Oxygen and Magnesium Isotopic Ratios of Presolar Spinel Grains; Study of Two New Presolar Grains from Bishunpur Ordinary Chondrite; Extinct Technetium in Presolar Grains; etc.

Source record↗

High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

Background: Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). Methods and Results: 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P<0.001). Conclusions: Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

Rahman, Atiar↗

High frequency QRS ECG predicts ischemic defects during myocardial perfusion imaging

Changes in high frequency QRS components of the electrocardiogram (HF QRS ECG) (150-250 Hz) are more sensitive than changes in conventional ST segments for detecting myocardial ischemia. We investigated the accuracy of 12-lead HF QRS ECG in detecting ischemia during adenosine tetrofosmin myocardial perfusion imaging (MPI). 12-lead HF QRS ECG recordings were obtained from 45 patients before and during adenosine technetium-99 tetrofosmin MPI tests. Before the adenosine infusions, recordings of HF QRS were analyzed according to a morphological score that incorporated the number, type and location of reduced amplitude zones (RAZs) present in the 12 leads. During the adenosine infusions, recordings of HF QRS were analyzed according to the maximum percentage changes (in both the positive and negative directions) that occurred in root mean square (RMS) voltage amplitudes within the 12 leads. The best set of prospective HF QRS criteria had a sensitivity of 94% and a specificity of 83% for correctly identifying the MPI result. The sensitivity of simultaneous ST segment changes (18%) was significantly lower than that of any individual HF QRS criterion (P less than 0.00l). Analysis of 12-lead HF QRS ECG is highly sensitive and specific for detecting ischemic perfusion defects during adenosine MPI stress tests and significantly more sensitive than analysis of conventional ST segments.

Source record↗

Crystalline Aluminosilicates for Radionuclide Remediation

Crystalline aluminosilicates have a wide range of applications such as media for the capture and/or immobilization of radionuclides. Several different types of metal-exchanged zeolites have been successfully demonstrated as effective sorbents for gaseous, aqueous, or solid-state capture and immobilization of radionuclides including iodine [e.g., I2(g), CH3I(g)], xenon, krypton, radium (e.g., 226Ra and 228Ra), selenium (e.g., 79Se6+), technetium (e.g., 99TcO4-), strontium (e.g., 90Sr2+), cesium (e.g., 135Cs+, 137Cs+), mixed alkali halide streams (i.e., iodide and chloride salts), and actinides (e.g., U6+, Th4+). These zeolites include sodalite (SOD), mordenite (MOR or Z-type), faujasite (FAU), Linde type-A (LTA), cancrinite (CAN), gismondine (GIS), and heulandite (or clinoptilolite) (HEU). The structural building blocks of these seven materials vary from cages (e.g., a-cages, ß-cages, e-cages) to channels linking various cage types and these are mostly comprised of aluminosilicates. This chapter will delve into the crystallographic differences between these framework materials and provide a brief overview of literature data where these seven crystalline aluminosilicates have been utilized for the capture and/or immobilization of radionuclides. Metal-exchanged zeolites (e.g., MOR, FAU, LTA) have often been the source of study for gaseous capture of iodine where the more promising compositions include Ag-exchanged sorbents; these types of materials can be made in a variety of robust forms including berl saddles and extrudates. Sodalite can be used as an immobilization strategy for halide waste streams (e.g., Cl, I), including those from electrochemical reprocessing of used nuclear fuel, as well as TcO4–. Cancrinite has been demonstrated to enhance sorption capacity of sediments for several problematic ionic radionuclides including Cs+, SeO42–, and TcO4–. Actinides such as U6+ and Th4+ have been successfully captured from solutions using MOR, FAU, LTA, and HEU-type aluminosilicates. Finally, mixtures of aluminosilicates have been included in a set of zeolite materials that show promise as sorbents for 226Ra and 228Ra removal from mine waters.

zeolites, aluminosilicates, radionuclide remediati↗

Pertechnetate/perrhenate–capped Zr/Hf–Dihydroxide Dimers: Elucidating Zr–TcO 4 Co–Mobility in the Nuclear Fuel Cycle

Spent nuclear fuel contains heavy element fission products that must be separated for effective reprocessing for a safe and sustainable nuclear fuel cycle. 93 Zr and 99 Tc are high-yield fission products that co-transport in liquid-liquid extraction processes. Here we seek atomic-level information of this co-extraction process, as well as fundamental knowledge about Zr IV (and Hf IV ) aqueous speciation in the presence of topology-directing ligands such as pertechnetate (TcO 4 – ) and non-radioactive surrogate perrhenate (ReO 4 – ). In this context, we show that the flat tetrameric oxyhydroxyl-cluster [M IV 4 (OH) 8 (H 2 O) 16 ] 8+ (and related polymers) is dissociated by perrhenate/pertechnetate to yield isostructural dimers, M 2 (OH) 2 (XO 4 – ) 6 (H 2 O) 6 • 3H 2 O (M=Zr/Hf IV ; X=Re/Tc VII ), elucidated by single-crystal X-ray diffraction. We used these model compounds to understand the pervasive 93 Zr- 99 Tc coextraction with further speciation studies in water, nitric acid, and tetrabutylphosphate (TBP) -kerosene; where the latter two media are relevant to nuclear fuel reprocessing. SAXS (small angle X-ray scattering), compositional evaluation, and where experimentally feasible, ESI-MS (electrospray ionization mass spectrometry) showed that perrhenate/pertechnetate influence Zr/Hf IV -speciation in water. Here, in Zr-XO 4 solvent extraction studies to simulate fuel reprocessing, we provide evidence that TcO 4 – enhances extraction of Zr IV , and compositional analysis of the extracted metal-complexes (Zr-ReO 4 study) is consistent with the crystallized Zr IV 2 (OH) 2 (Re VII O 4 – ) 6 (H 2 O) 6 •dimer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Detection and Mitigation of Radionuclides in the Environment: Toward a Clean Ecosystem

This research describes a straightforward approach to producing surface-engineered nanomaterials for the detection and mitigation of radionuclides generated in nuclear facilities. Here, a micelle forming surfactant ligand, namely cetyltrimethylammonium bromide (CTAB), was engineered on the surface of iron oxide nanoparticles and explored for the removal of radioactive materials, such as pertechnetate (TcO 4 – ), from aqueous environments. A series of analytical tools were employed to characterize the nanocomposite materials, such as SEM, EDS, UV-Vis spectroscopy, DLS, and PALS, and evaluated for their ability to capture a model analyte, perrhenate (ReO 4 – ) ions. The iron oxide magnetic nanoparticles retain their magnetic properties after surface functionalization and can be easily manipulated and collected with a magnet. Therefore, these nanocomposite materials can be used to remotely remediate environments by scavenging and collecting radionuclide species at the desired location.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Volatility of sodium, potassium, and cesium perrhenates determined by thermogravimetry

Here, in this study, we investigated the volatility of sodium, potassium, and cesium perrhenates using thermogravimetry (TG) performed on single salts and their binary mixed salts. We performed simultaneous TG and differential scanning calorimetry under a ramp heating condition at 10°C/min up to 1200°C to characterize volatilization behavior as a function of temperature. We also performed isothermal TG over a temperature range of 700 to 975°C to estimate the vapor pressures of the alkali perrhenates based on a modified Langmuir equation that relates the rate of free evaporation from the open surface to vapor pressure. In this paper, we discuss the results of our study on the temperature of evaporation and temperature-dependent vapor pressure of sodium, potassium, and cesium perrhenates in relation to rhenium volatilization behavior observed during melting of simulated waste glass.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Part I: Predicting performance of Purolite A532E resins for remediation of comingled contaminants in groundwater

Ion exchange (IX) resins are used in pump-and-treat (P&T) facilities to remove soluble groundwater contaminants. However, natural anions present at concentrations orders of magnitude higher than contaminants can compete for IX sites and impact resin lifecycles. Here, the Hanford Site’s 200 West Area P&T facility (Washington State, USA) was selected as a case study because it currently uses two IX resins: Purolite® A532E (A532E) to remove pertechnetate (TcO 4 - ) and DOWEX 21K (DOWEX) to remove uranium from groundwater. Nitrate (NO 3 - ), sulfate (SO 4 2- ), chloride (Cl - ), and carbonate (CO 3 2- ) anions have been identified to potentially compete for A532E and DOWEX IX sites. Hanford-relevant anion groundwater concentrations were used to design a series of laboratory-scale batch experiments to evaluate the impact of competing anions on resin performance and potential kinetic effects. These data are then modeled to obtain Cl--normalized equilibrium exchange coefficients (K) needed to predict IX resin performance. The work is presented in two parts, with IX performance evaluated for A532E in Part I and DOWEX in Part II. Part I results demonstrate that TcO 4 - uptake is not impacted by NO 3 - , SO 4 2- , Cl - , CO 3 2- (as HCO 3 - ) and U(VI) carbonate anions, with K TcO4-/Cl- > 4,000, likely due to the high selectivity of A532E trihexylammonium sites for the large, weakly hydrated TcO 4 - anion. Other anion K values were K NO3-/Cl- = 20, K SO4--/Cl- = 0.2, K HCO3-/Cl- = 0.09, K U/Cl- = 370–1000. These K values provide conservative parameters for predicting A532E performance, and demonstrate that, under these test conditions, A532E will remove TcO 4 - from current and future influent streams to meet groundwater treatment objectives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Part II: Predicting performance of $\mathrm{DOWEX 21K}$ resin for remediation of comingled contaminants in groundwater

The selectivity of ion exchange (IX) resins for aqueous contaminant removal can be impacted by changing concentrations of competing natural groundwater ions. In a two-part investigation, the Hanford Site 200 West Area pump-and-treat (P&T) facility in Washington State, USA is used as a case study to evaluate the performance of two IX resins for groundwater treatment: Purolite® A532E for pertechnetate (TcO 4 - ) removal, explored in Part I, and DOWEX 21K (DOWEX) for uranium (U) removal. In Part II, DOWEX selectivity for U, as uranyl carbonate species, and uptake kinetics is quantified in a series of laboratory-scale aqueous batch experiments containing Hanford-relevant concentrations of competing anions nitrate (NO 3 - ), sulfate (SO 4 2- ), chloride (Cl - ), and carbonate (CO 3 2- ), as well as co-mingled contaminant TcO 4 - . Here the results demonstrate that DOWEX trimethylammonium functional groups are highly selective for U carbonate species (85–100 % uptake) under all conditions investigated. Only NO 3 - concentrations of 100 mM were shown to decrease U removal, with the extent (85–99 %) depending on competing anion concentrations present in solution. However, at the highest NO 3 - concentrations reported for groundwaters treated at the P&T facility (25 mM), the effect on U uptake is minimal. The batch sorption results are modeled to obtain chloride normalized equilibrium exchange coefficients (K) for predicting DOWEX performance: K SO4--/Cl- = 2.0, K NO3-/Cl- = 5.0, K HCO3-/Cl- = 1.5, K TcO4-/Cl- = 2,000, and K U/Cl- = 50,000. These K values predict little effect of current and future influent chemistries on U removal by DOWEX, where both uranyl carbonate species and TcO 4 - are removed such that effluent concentrations meet groundwater treatment requirements.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Preoperative and Intraoperative Mobile Gamma Camera Imaging in Sentinel Lymph Node Biopsy for Melanoma Independent of Preoperative Lymphoscintigraphy

Sentinel lymph node biopsy (SLNB) is standard practice for staging cutaneous melanoma. High false negative rates have increased interest in adjunctive techniques for localizing SLNs. Mobile gamma cameras (MGCs) represent potential tools to enhance SLNB performance. Twenty eligible melanoma patients underwent 99mTc sulfur colloid injection and standard lymphoscintigraphy with a fixed gamma camera (FGC). A survey using a 20 cm square MGC, performed immediately preoperatively by the study surgeon, was used to establish an operative plan while blinded to the FGC results. Subsequently, SLNB was performed using a gamma probe and a novel 6 cm diameter handheld MGC. A total of 24 SLN basins were detected by FGC. Prior to unblinding, all 24 basins were identified with the preoperative MGC, and the operative plan established by preoperative MGC imaging was confirmed accurate by review of the FGC images. All individual SLNs were identified during intraoperative MGC imaging, and in 5/24 (21%) cases, additional clinical information was obtained from the MGC. Preoperative MGC images provide information consistent with FGC images for planning SLNB and in some cases provides additional information that aided in surgical decision-making.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solvothermal synthesis and solid-state characterization of metal-metal bonded tetracarboxylatoditechnetium(II,III) polymers

Investigations of solvothermal reactions with pertechnetate, [TcO 4 ] - , have produced four new low-valent Tc extended metal atom chain (EMAC) complexes with multiple metal-metal bonds. The thermal reaction of potassium pertechnetate with glacial acetic acid, under in-situ hydrogen production from the decomposition of sodium borohydride, yields purple elongated crystals determined to be tetraacetato ditechnetium (II,III) acetate (1), [Tc 2 (O 2 CCH 3 ) 4 (μ-O 2 CCH 3 ] n . Compound 1 was characterized by single crystal X-ray diffraction and its magnetic properties recorded between 10 and 300 K. Single crystal X-ray diffraction analysis of 1 indicates the Tc 2 +5 tetraacetato unit is linked by the carboxylate oxygens of the bridging acetate, similar to known chloride and bromide linkage polymers of composition [Tc 2 (μ-O 2 CCH 3 ) 4 Cl] n , and [Tc 2 (μ-O 2 CCH 3 ) 4 Br] n . Here, using the same synthetic method three similar compounds have been synthesized from propionic, benzoic and pivalic acid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative uptake, translocation, and plant mediated transport of Tc-99, Cs-133, Np-237, and U-238 in Savannah River Site soil columns for the grass species Andropogon virginicus

Here, this study examines the ability of the grass species Andropogon virginicus to alter the subsurface transport and redistribution of a suite of radionuclides ( 99 Tc, 133 Cs (stable analog for 135 Cs and 137 Cs), 237 Np, 238 U) with varying chemical behaviors in a Savannah River Site soil via the use of vegetated and unvegetated soil columns. After an acclimation period, a small volume of solution containing all radionuclides was introduced into the columns via Rhizon© pore water sampling tubes. Plants were grown for an additional 4 weeks before shoots were harvested, and columns were prepared for sampling. Plant presence led to decreased radionuclide release from the columns, mainly due to radionuclide specific combinations of system hydrology differences resulting from plant transpiration as well as plant uptake. For the most mobile radionuclides, 99 Tc followed by 237 Np, plant presence resulted in significantly different soil concentration profiles between vegetated and unvegetated columns, including notable upward migration for 237 Np in columns with plants. Additionally, plant uptake of 99 Tc was the greatest of all the radionuclides, with plant tissues containing an average of 44 % of the 99 Tc, while plant uptake only accounted for <2 % of 237 Np and <0.5 % of 133 Cs and 238 U in the system. Although overall plant uptake of 133 Cs and 238 U were similar, the majority of 133 Cs taken up by plants was associated with 133 Cs already available in the aqueous phase while 238 U uptake was mainly associated with the solid phase, meaning that plant activity resulted in a fraction of the native 238 U being mobilized and thus, made available for plant uptake. Overall, this study quantified the influence of several plant-mediated physical and biogeochemical factors that have significant influence on radionuclide mobility and transport in this complex system which can be further utilized in future system or site-specific environmental transport and risk assessment models.

59 BASIC BIOLOGICAL SCIENCES↗

Choline chloride-formic acid mixture as a medium for the reduction of pertechnetates – electrochemical and spectroscopic studies

In this work, physicochemical properties of the choline chloride (ChCl) and formic acid (FA) mixture (1:2 molar ratio) have been studied over a broad range of temperatures (-140°C – 60 °C). Differential scanning calorimetry has shown that the examined system remains in liquid state at very low temperatures - a glass transition is observed in the range of -125 °C to - 90 °C. The kinematic viscosity, ionic conductivity and the width of the electrochemical window determined for this system revealed its beneficial electrochemical properties. This indicates suitability of ChCl:FA electrolytes in electrochemical measurements. In this non-aqueous electrolyte, the electrochemical reduction of Tc(VII) ions has been studied for the first time. Cyclic voltammetry and chronopotentiometry experiments revealed that the electroreduction of the pertechnetates is a multi-path process which leads to formation of a Tc(IV) ionic form. X-ray absorption spectroscopy of the latter revealed its structure as a TcCl 6 2- complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling $T_c$ through Band Structure and Correlation Engineering in Collapsed and Uncollapsed Phases of Iron Arsenides

Recent observations of selective emergence (suppression) of superconductivity in the uncollapsed (collapsed) tetragonal phase of LaFe 2 As 2 has rekindled interest in understanding what features of the band structure control the superconducting $T_c$. In this work, we show that the proximity of the narrow Fe-$d_{xy}$ state to the Fermi energy emerges as the primary factor. In the uncollapsed phase this state is at the Fermi energy, and is most strongly correlated and a source of enhanced scattering in both single and two particle channels. The resulting intense and broad low energy spin fluctuations suppress magnetic ordering and simultaneously provide glue for Cooper pair formation. In the collapsed tetragonal phase, the $d_{xy}$ state is driven far below the Fermi energy, which suppresses the low-energy scattering and blocks superconductivity. A similar source of broad spin excitation appears in uncollapsed and collapsed phases of CaFe 2 As 2 . This suggests controlling coherence provides a way to engineer $T_c$ in unconventional superconductors primarily mediated through spin fluctuations.

36 MATERIALS SCIENCE↗

FIU Project 2: Environmental Remediation Science & Technology [Slides]

FIU’s research under this project involves conducting basic and applied science to fill knowledge gaps and validate potential remediation technologies for contaminated soil and groundwater and the assessment of the fate and transport of contaminants in the environment. The aim of FIU’s research is to reduce the potential for contaminant mobility or toxicity in the surface and subsurface through the development and application of state-of-the-art scientific and environmental remediation technologies at the Hanford Site, Savannah River Site (SRS), and the Waste Isolation Pilot Plant (WIPP), which is the Nation’s only mined geologic repository for permanent disposal of transuranic waste. FIU collaborates with scientists from Pacific Northwest National Laboratory (PNNL), Savannah River National Laboratory (SRNL), Savannah River Ecology Laboratory (SREL), Los Alamos National Laboratory (LANL) and the DOE Carlsbad Field Office (CBFO) in order to plan and execute research that is synergistic with the work being conducted at the sites, and that supports the resolution of critical science and engineering needs which leads to a better understanding of the long-term behavior of subsurface contaminants. The knowledge gained through this research will be used to transform experimental and modeling innovations into practical applications deployed at the sites to support EM’s primary goal of expediting the closure of major contaminated soil and groundwater sites and waste units. Collaborative relationships between FIU and the national laboratories have provided large benefits over the years to FIU, the national laboratories, the DOE complex, and the DOE EM mission. By working closely with the national laboratories, FIU’s research is not only closely aligned with the cleanup mission priorities at the DOE sites, but complements and supports ongoing work at the national laboratories for screening of new remedial technologies. This coordination and leveraging of research efforts results in time- and cost-savings, and will accelerate progress of the DOE EM environmental restoration mission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗