Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stream Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

An Informatics Approach to Demand Response Optimization in Smart Grids

Power utilities are increasingly rolling out “smart” grids with the ability to track consumer power usage in near real-time using smart meters that enable bidirectional communication. However, the true value of smart grids is unlocked only when the veritable explosion of data that will become available is ingested, processed, analyzed and translated into meaningful decisions. These include the ability to forecast electricity demand, respond to peak load events, and improve sustainable use of energy by consumers, and are made possible by energy informatics. Information and software system techniques for a smarter power grid include pattern mining and machine learning over complex events and integrated semantic information, distributed stream processing for low latency response,Cloud platforms for scalable operations and privacy policies to mitigate information leakage in an information rich environment. Such an informatics approach is being used in the DoE sponsored Los Angeles Smart Grid Demonstration Project, and the resulting software architecture will lead to an agile and adaptive Los Angeles Smart Grid.

Simmhan, Yogesh↗

Automation of Extraction Chromatograhic and Ion Exchange Separations for Radiochemical Analysis and Monitoring

Radiochemical analysis, complete with the separation of radionuclides of interest from the sample matrix and from other interfering radionuclides, is often an essential step in the determination of the radiochemical composition of a nuclear sample or process stream. Although some radionuclides can be determined nondestructively by gamma spectroscopy, where the gamma rays penetrate significant distances in condensed media and the gamma ray energies are diagnostic for specific radionuclides, other radionuclides that may be of interest emit only alpha or beta particles. For these, samples must be taken for destructive analysis and radiochemical separations are required. For process monitoring purposes, the radiochemical separation and detection methods must be rapid so that the results will be timely. These results could be obtained by laboratory analysis or by radiochemical process analyzers operating on-line or at-site. In either case, there is a need for automated radiochemical analysis methods to provide speed, throughput, safety, and consistent analytical protocols. Classical methods of separation used during the development of nuclear technologies, namely manual precipitations, solvent extractions, and ion exchange, are slow and labor intensive. Fortunately, the convergence of digital instrumentation for preprogrammed fluid manipulation and the development of new separation materials for column-based isolation of radionuclides has enabled the development of automated radiochemical analysis methodology. The primary means for separating radionuclides in solution are liquid-liquid extraction and ion exchange. These processes are well known and have been reviewed in the past.1 Ion exchange is readily employed in column formats. Liquid-liquid extraction can also be implemented on column formats using solvent-impregnated resins as extraction chromatographic materials. The organic liquid extractant is immobilized in the pores of a microporous polymer material. Under suitable conditions, the analyte of interest partitions into the immobilized organic phase while other matrix speces and interferences are washed away in the mobile aqueous phase. After the wash step, retained analytes are rapidly released in one or more steps by changing the aqueous eluent, such that the analytes now partition back into the mobile phase. The development of solvent impregnated resins, their physical chemistry, technological applications for metal and radionuclide recovery, and analytical uses were described in detail in a previous chapter in this series by Cortina and Warshawsky. The extraction chromatographic approach is well suited for the isolation of radionuclides from complex sample matrixes in a rapid automated format. The development of automated radioanalytical methods is, in fact, closely coupled to the availability of such materials. In this review, we will focus on the application of radiochemical separations in automated fluidic formats for the analysis of alpha- and beta-emitting radionuclides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Valley development on Hawaiian volcanoes

Work in progress on Hawaiian drainage evolution indicates an important potential for understanding drainage development on Mars. Similar to Mars, the Hawaiian valleys were initiated by surface runoff, subsequently enlarged by groundwater sapping, and eventually stabilized as aquifers were depleted. Quantitative geomorphic measurements were used to evaluate the following factors in Hawaiian drainage evolution: climate, stream processes, and time. In comparing regions of similar climate, drainage density shows a general increase with the age of the volcani island. With age and climate held constant, sapping dominated valleys, in contrast to runoff-dominated valleys, display the following: lower drainage densities, higher ratios of valley floor width to valley height, and more positive profile concavities. Studies of stream junction angles indicate increasing junction angles with time on the drier leeward sides of the major islands. The quantitative geomorphic studies and earlier field work yielded important insights for Martian geomorphology. The importance of ash mantling in controlling infiltration on Hawaii also seems to apply to Mars. The Hawaiian valley also have implications for the valley networks of Martian heavily cratered terrains.

Baker, Victor R.↗

Hanford Direct Feed Low Activity Waste Real Time Monitoring Program - 18336

Effective operation of the Low-Activity Waste (LAW) Facility at Hanford will rely on information provided from monitoring and control of chemical process streams to maintain safety and environmental compliance, product quality, and operational efficiency. The LAW Facility has been designed as a contact-maintained facility and it was recognized that establishing a real time, in-line monitoring program could have substantial benefits to the U.S. Department of Energy, Office of River Protection in the long-term, which include significant time savings, increased processing efficiency and effectiveness, reducing worker exposure to radiation and chemical hazards, reducing secondary wastes, and a better understanding of the flowsheet to support direct-feed LAW (DFLAW). The Assistant Manager/Federal Project Director for the Waste Treatment and Immobilization Plant (WTP) Project chartered a multidisciplinary integrated technical team comprised of federal, contractor, and national laboratory staff to develop a phased program to support this initiative. A three-phase approach was adopted: - Phase 1: Requirements and Opportunities Analysis for Sampling Reduction; - Phase 2: Applications and Benefits Determination; - Phase 3: Qualification and Demonstration. The focus of Phase 1 is to identify the drivers behind any requirements for sampling and any opportunities to benefit from a real-time monitoring program. The effort identified 18 sample points and approximately 2,600 potential samples to be collected annually with analytical methods to be performed approximately 18,000 times annually. Based on Savannah River National Laboratory experience and discussions with WTP Analytical Laboratory personnel, these sample analyses will generate approximately 5,000 L of liquid secondary waste and approximately 1,300 m{sup 3} of solid secondary waste each year. Additional solid and liquid secondary wastes will be generated from sample collection. A preliminary evaluation indicates that employing real-time, in-line monitoring, mass balances, and periodic sampling could significantly reduce the number of samples collected, analytical methods performed, and secondary waste generated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel CO{sub 2} capture. Final CRADA Report.

The goal of this work was to use electrochemically driven pH control to develop a second generation, enzyme-based contained liquid membrane (CLM) permeator to extract CO{sub 2} from a variety of coal-based flue gas streams more efficiently than does the CLM current design, while achieving performance coincident with DOE targets of less than 45% Cost of electricity (COE) in 2007 and less than 20% COE in 2012. Central to this goal the CLM would be alkaline (>pH 8) at the feed gas side and acid (<pH 6) at the permeate side. Argonne demonstrated the technical feasibility for CO{sub 2} capture and release using Argonne's resin-wafer electrode ionization (RW-EDI) system integrated with Carbozyme's carbonic anhydrase (CA) enzyme. Argonne developed RW-EDI for pH controlled desalination of process streams (e.g. Patents 7,452,920 & 7,306,934). In the current work, Argonne captured CO{sub 2} as HCO{sub 3}{sup -} and released it as CO{sub 2}. The goal is to both capture CO{sub 2} from a simulated flue gas stream and release it within the DOE targets for increase in COE. Initial performance results indicate that the 2012 COE targets are achievable with the developed technology. The design is subject to patent-hold. This task was funded in an exploratory phase, so no process optimization was attempted. Argonne believes that with optimization this performance could be significantly improved.

54 ENVIRONMENTAL SCIENCES↗

Selective phosphate removal with manganese oxide composite anion exchange membranes in membrane capacitive deionization

The discharge of excessive phosphorous into water bodies can lead to serious eutrophication threatening aquatic ecosystem. Membrane capacitive deionization (MCDI) is an effective platform for deionizing aqueous streams; however, conventional MCDI is unable to selectively remove targeted ions from a liquid mixture. Here, in this work, we fabricated manganese oxide composite anion exchange membranes (AEMs) for MCDI to enhance phosphate removal selectivity from sodium chloride-sodium dihydrogen phosphate (10:1 M ratio) aqueous mixtures. We systematically investigated several critical factors, such as constant current or voltage operation, applied voltage amount, process stream pH, and manganese oxide (Mn 2 O 3 ) content in the AEM, on phosphate removal efficiency and phosphate selectivity. A trade-off was observed between phosphate removal and selectivity when increasing the cell voltage. Under the best conditions, a MCDI unit with a 20 wt% Mn 2 O 3 composite AEM and a bipolar membrane facilitated high phosphate removal efficiency of ≥ 31.8 % and a phosphate over chloride selectivity of 1.1 while showing stability for at least 30 cycles. To help understand how Mn 2 O 3 composite AEM boosts phosphate selectivity, static electronic structure calculations were performed, and they revelated that hydrogen phosphate absorption on Mn 2 O 3 composite AEM was 314 kcal/mol more exothermic than that on pristine AEM while chloride adsorption on Mn 2 O 3 composite AEM was 2.2 kcal/mol less exothermic than that on a pristine AEM. Overall, this work presents an effective strategy for selectively removing phosphate from model wastewater solutions and the mechanistic understanding that governs ion selectivity in composite ion-exchange membranes used in MCDI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Piecewise Local Partial Least Squares (PLS) Method for the Quantitative Analysis of Plutonium Nitrate Solutions

We have developed a piecewise local (PL) partial least squares (PLS) analysis method for total plutonium measurements by absorption spectroscopy in nitric acid-based nuclear material processing streams. Instead of using a single PLS model that covers all expected solution conditions, the method selects one of several local models based on an assessment of solution absorbance, acidity, and Pu oxidation state distribution. The local models match the global model for accuracy against the calibration set, but were observed in several instances to be more robust to variations associated with measurements in the process. The improvements are attributed to the relative parsimony of the local models. Not all of the sources of spectral variation are uniformly present at each part of the calibration range. Thus, the global model is locally overfitting and susceptible to increased variance when presented with new samples. A second set of models quantifies the relative concentrations of Pu(III), (IV), and (VI). Standards containing a mixture of these species were not at equilibrium due to a disproportionation reaction. Therefore, a separate principal component analysis is used to estimate of the concentrations of the individual oxidation states in these standards in the absence of independent confirmatory analysis. The PL analysis approach is generalizable to other systems where the analysis of chemically complicated systems can be aided by rational division of the overall range of solution conditions into simpler sub-regions.

47 OTHER INSTRUMENTATION↗

Selective Removal of Lanthanides from Natural Waters, Acidic Streams and Dialysate

The increased demand for the lanthanides in commercial products result in increased production of lanthanide containing ores, increasing public exposure to the lanthanides, both from various commercial products and from production wastes/effluents. This work investigates lanthanide (La, Ce, Pr, Nd, Eu, Gd, Lu) binding properties of self-assembled monolayers on mesoporous silica supports (SAMMS®) that were functionalized with diphosphonic acid (DiPhos), acetamide phosphonic acid (AcPhos), propionamide phosphonic acid (ProPhos), and 1-hydroxy-2-pyridinone (1,2-HOPO) from natural waters (river, ground, and sea waters), acid solutions (to mimic certain industrial process streams), and dialysate and compares their performance to a high surface area activated carbon. The properties include sorption affinity, capacity, and sorption kinetics. Stability and regenerability of SAMMS materials were also investigated. Going from the acid side over to the alkaline side, the AcPhos- and DiPhos-SAMMS maintain their outstanding affinity for lanthanides, which enable the use of the materials in the systems where the pH may fluctuate. While the activated carbon is as effective as 1,2-HOPO-SAMMS for capturing lanthanides in natural (alkaline) waters, it has no affinity in acid solutions (pH 2.4) and low affinity in carbonate-rich dialysate. Over 99% of 100 ug/L of Gd in dialysate was removed by the ProPhos-SAMMS after ten minutes. SAMMS can be regenerated with an acid wash (0.5 M HCl) without losing the binding properties, for a number of regeneration cycles. In acid solutions, PhoPhos- and 1,2-HOPO-SAMMS have differing affinity along the lanthanide series, suggesting their potential for chromatographic lanthanide separations. Thus, SAMMS materials have a great potential to be used as sorbents in large scale treatment of lanthanides, lanthanide separation prior to analytical instruments, and sorbent dialyzers for lanthanide clearances.

acidic streams↗

Streaming Analytics and Data Engineering

SADE is a software package for rapidly assembling analytic pipelines to manipulate data. The packages consists of the engine that manages the data and coordinates the movement of data between the tasks performing a function, a set of core libraries consisting of plugins that perform common tasks, and a framework to extend the system supporting the development of new plugins. Currently through configuration files, a pipeline can be defined that maps the routing of data through a series of plugins. Pipelines can be run in a batch mode or can process streaming data; they can be executed from the command line or run through a Windows background service. There currently exists over a hundred plugins, over fifty pipeline configurations, and the software is now being used by about a half-dozen projects.

Source record↗

Preliminary Assessment of the Low-Temperature Waste Form Technology Coupled with Technetium Removal

The U.S. Department of Energy Office of Environmental Management (EM) is engaging the national laboratories to provide the scientific and technological rigor to support EM program and project planning, technology development and deployment, project execution, and assessment of program outcomes. As an early demonstration of this new responsibility, Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) have been chartered to implement a science and technology program addressing low-temperature waste forms for immobilization of DOE aqueous waste streams, including technetium removal as an implementing technology. As a first step, the laboratories examined the technical risks and uncertainties associated with the Cast Stone waste immobilization projects at Hanford. Science and technology needs were identified for work associated with 1) conducting performance assessments and risk assessments of waste form and disposal system performance, and 2) technetium chemistry in tank wastes and separations of technetium from waste processing streams. Technical approaches to address the science and technology needs were identified and an initial sequencing priority was suggested. The following table summarizes the most significant science and technology needs and associated approaches to address those needs. These approaches and priorities will be further refined and developed as strong integrated teams of researchers from national laboratories, contractors, industry, and academia are brought together to provide the best science and technology solutions. Implementation of a science and technology program that addresses these needs by pursuing the identified approaches will have immediate benefits to DOE in reducing risks and uncertainties associated with near-term decisions regarding supplemental immobilization at Hanford. Longer term, the work has the potential for cost savings and for providing a strong technical foundation for future performance assessments at Hanford and across the DOE complex.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Efficiency Test for Pyrochemical Fuel Cycles

An engineering-scale integrated efficiency test was conducted with sodium-bonded, spent EBR-II drive fuel elements. The major pieces of equipment involved in the test were the element chopper, Mk-IV electrorefiner, cathode processor, and casting furnace. Four electrorefining batches (containing 50.4 kg HM) were processed under a set of fixed operating parameters that have been developed for the equipment based on over a decade’s worth of processing experience. A mass balance around this equipment was performed. Actinide dissolution and recovery efficiencies were established based on the mass balance and chemical analytical results of various samples taken from process streams during the integrated efficiency test.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of the Cast Stone Low-Temperature Waste Form Technology Coupled with Technetium Removal - 14379

The U.S. Department of Energy Office of Environmental Management (EM) is engaging the national laboratories to provide the scientific and technological rigor to support EM program and project planning, technology development and deployment, project execution, and assessment of program outcomes. As an early demonstration of this new responsibility, Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) were chartered to implement a science and technology program addressing low-temperature waste forms for immobilization of DOE aqueous waste streams, including technetium removal as an implementing technology. As a first step, the laboratories examined the technical risks and uncertainties associated with the Cast Stone waste immobilization and technetium removal projects at Hanford. Science and technology gaps were identified for work associated with 1) conducting performance assessments and risk assessments of waste form and disposal system performance, and 2) technetium chemistry in tank wastes and separation of technetium from waste processing streams. Technical approaches to address the science and technology gaps were identified and an initial sequencing priority was suggested. A subset of research was initiated in 2013 to begin addressing the most significant science and technology gaps. The purpose of this paper is to report progress made towards closing these gaps and provide notable highlights of results achieved to date.

Cast Stone Low-Temperature Waste Form Technology C↗

Novel Non-Vacuum Fabrication of Solid State Lithium Ion Battery Components

The purpose of this Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and Planar Energy Devices, Inc. was to develop large-scale electroless deposition and photonic annealing processes associated with making all-solid-state lithium ion battery cathode and electrolyte layers. However, technical and processing difficulties encountered in 2011 resulted in the focus of the CRADA being redirected solely to annealing of the cathode thin films. In addition, Planar Energy Devices de-emphasized the importance of annealing of the solid-state electrolytes within the scope of the project, but materials characterization of stabilized electrolyte layers was still of interest. All-solid-state lithium ion batteries are important to automotive and stationary energy storage applications because they would eliminate the problems associated with the safety of the liquid electrolyte in conventional lithium ion batteries. However, all-solid-state batteries are currently produced using expensive, energy consuming vacuum methods suited for small electrode sizes. Transition metal oxide cathode and solid-state electrolyte layers currently require about 30-60 minutes at 700-800°C vacuum processing conditions. Photonic annealing requires only milliseconds of exposure time at high temperature and a total of <1 min of cumulative processing time. As a result, these processing techniques are revolutionary and highly disruptive to the existing lithium ion battery supply chain. The current methods of producing all-solid-state lithium ion batteries are only suited for small-scale, low-power cells and involve high-temperature vacuum techniques. Stabilized LiNi x Mn y Co z Al 1-x-y-z O 2 (NMCA) nanoparticle films were deposited onto stainless steel substrates using Planar Energy Devices’ streaming process for electroless electrochemical deposition (SPEED). Since successful SPEED trials were demonstrated by Planar Energy Devices with NMCA prior to 2010, this high-voltage (i.e. 5 V) cathode material was the focus of the project. ORNL had also shown in prior work that photonic annealing can be used to anneal conventionally coated cathode metal oxide structures into the active crystalline phase. Planar Energy Devices also had demonstrated SPEED with solid electrolyte layers consisting of LiGaAlSPO 4 prior to the start of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation and Optimization of Volatile Fatty Acid Upgrading Strategies for Sustainable Transportation Fuel Production

The multicomponent nature of and variability of biomass makes chemical upgrading via a single process stream to a single end use infeasible for most feedstocks. A more promising approach is to identify upgrading strategies (encompassing bioprocessing, catalysis, and separations) which valorize varied biomass fractions to distinct products to which each is best suited. A robust procedure to carry out this goal should incorporate comparison of various upgrading procedures as well as suitability of products to a slate of identified end uses. We applied this strategy to one biomass-derived feedstock, volatile fatty acids (VFAs) derived from wet waste arrested anaerobic digestion, by developing a computer program, VFA Upgrading to Liquid Transportation fUels Refinery Estimation (VULTURE) which evaluates VFA catalytic upgrading to liquid transportation fuels. VULTURE considers multiple separations, catalysis (ketonization, hydrogenation), and fuel application options, generating hundreds of candidate scenarios for a given VFA stream, then selects several promising strategies that optimize bio-content of products with properties best suited for target fuel types. We find that VFAs are upgraded most efficiently when separate light alcohol (C3-6) and heavy hydrocarbon or alcohol (C7-13) fractions are targeted to create gasoline and heavy-duty (diesel or jet) fuels or fuel blends. Surrogate property testing of VULTURE-recommended fuels reveals that most predictive models employed are robust, while rigorous process simulation shows that the simple unit operation assumptions used in VULTURE are largely accurate, especially for heavy-duty fuel synthesis. Techno-economic and life-cycle analyses show that VFA-derived fuels are profitable and have dramatically (=57%) lower carbon intensities than fossil analogs.

BIOMASS FUELS↗

Large-Scale Spray Releases: Additional Aerosol Test Results

One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the relevant physical properties projected for actual WTP process streams.

42 ENGINEERING↗

DWPF DECON FRIT: SUMP AND SLURRY SOLIDS ANALYSIS

The Savannah River National Laboratory (SRNL) has been requested to perform analyses on samples of the Defense Waste Processing Facility (DWPF) decon frit slurry (i.e., supernate samples and sump solid samples). Four 1-L liquid slurry samples were provided to SRNL by Savannah River Remediation (SRR) from the 'front-end' decon activities. Additionally, two 1-L sump solids samples were provided to SRNL for compositional and physical analysis. In this report, the physical and chemical characterization results of the slurry solids and sump solids are reported. Crawford et al. (2010) provide the results of the supernate analysis. The results of the sump solids are reported on a mass basis given the samples were essentially dry upon receipt. The results of the slurry solids were converted to a volume basis given approximately 2.4 grams of slurry solids were obtained from the {approx}4 liters of liquid slurry sample. Although there were slight differences in the analytical results between the sump solids and slurry solids the following general summary statements can be made. Slight differences in the results are also captured for specific analysis. (1) Physical characterization - (a) SEM/EDS analysis suggested that the samples were enriched in Li and Si (B and Na not detectable using the current EDS system) which is consistent with two of the four principle oxides of Frit 418 (B{sub 2}O{sub 3}, Na{sub 2}O, Li{sub 2}O and SiO{sub 2}). (b) SEM/EDS analysis also identified impurities which were elementally consistent with stainless steel (i.e., Fe, Ni, Cr contamination). (c) XRD results indicated that the sump solids samples were amorphous which is consistent with XRD results expected for a Frit 418 based sample. (d) For the sump solids, SEM/EDS analysis indicated that the particle size of the sump solids were consistent with that of an as received Frit 418 sample from a current DWPF vendor. (e) For the slurry solids, SEM/EDS analysis indicated that the particle size range of the slurry solids was much broader than compared to the sump solids. More specifically, there were significantly more fines in the slurry solids as compared to the sump solids. (f) PSD results indicated that > 99% of both the sump and slurry solids were less than 350 microns. The PSD results also supported SEM/EDS analysis that there were significantly more fines in the slurry solids as compared to the sump solids. (2) Weight Percent Solids - Based on the measured supernate density and mass of insoluble solids (2.388 grams) filtered from the four liters of liquid slurry samples, the weight percent insoluble solids was estimated to be 0.060 wt%. This level of insoluble solids is higher than the ETP WAC limit of 100 mg/L, or 0.01 wt% which suggests a separation technology of some type would be required. (3) Chemical Analysis - (a) Elemental results from ICP-ES analysis indicated that the sump solids and slurry were very consistent with the nominal composition of Frit 418. There were other elements identified by ICP analysis which were either consistent with the presence of stainless steel (as identified by SEM/EDS analysis) or impurities that have been observed in 'as received' Frit 418 from the vendor. (b) IC anion analysis of the sump solids and slurry solids indicated all of the species were less than detection limits. (c) Radionuclide analysis of the sump solids also indicated that most of the analytes were either at or below the detection limits. (d) Organic analysis of the sump solids and slurry solids indicated all of the species were less than detection limits. It should be noted that the results of this study may not be representative of future decon frit solutions or sump/slurry solids samples. Therefore, future DWPF decisions regarding the possible disposal pathways for either the aqueous or solid portions of the Decon Frit system need to factor in the potential differences. More specifically, introduction of a different frit or changes to other DWPF flowsheet unit operations (e.g., different sludge batch or coupling with other process streams) may impact not only the results but also the conclusions regarding acceptability with respect to the ETF WAC limits or other alternative disposal options.

36 MATERIALS SCIENCE↗

DWPF DECON FRIT SUPERNATE ANALYSIS

The Savannah River National Laboratory (SRNL) has been requested to perform analyses on samples of the Defense Waste Processing Facility (DWPF) decon frit slurry (i.e., supernate samples and sump solid samples). Four 1-L liquid slurry samples were provided to SRNL by Savannah River Remediation (SRR) from the 'front-end' decon activities. Additionally, two 1-L sump solids samples were provided to SRNL for compositional and physical analysis. This report contains the results of the supernate analyses, while the solids (sump and slurry) results will be reported in a supplemental report. The analytical data from the decon frit supernate indicate that all of the radionuclide, organic, and inorganic concentrations met the limits in Revision 4 of the Effluent Treatment Plant (ETP) Waste Acceptance Criteria (WAC) with the exception of boron. The ETP WAC limit for boron is 15.0 mg/L while the average measured concentration (based on quadruplicate analysis) was 15.5 mg/L. The measured concentrations of Li, Na, and Si were also relatively high in the supernate analysis. These results are consistent with the relatively high measured value of B given the compositional make-up of Frit 418. Given these results, it was speculated that either (a) Frit 418 was dissolving into the supernate or aqueous fraction and/or (b) fine frit particulates were carried forward to the analytical instrument based on the sampling procedure used (i.e., the supernate samples were not filtered - only settled with the liquid fraction being transferred with a pipette). To address this issue, a filtered supernate sample (using a 0.45 um filter) was prepared and submitted for analysis. The results of the filtered sample were consistent with 'unfiltered or settled' sample - relatively high values of B, Li, Na, and Si were found. This suggests that Frit 418 is dissolving in the liquid phase which could be enhanced by the high surface area of the frit fines or particulates in suspension. Based on the results of this study, it is recommended that DWPF re-evaluate the technical basis for the B WAC limit (the only component that exceeds the ETP WAC limit from the supernate analyses) or assess if a waiver or exception can be obtained for exceeding this limit. Given the possible dissolution of B, Li, Na, and Si into the supernate (due to dissolution of frit), DWPF may need to assess if the release of these frit components into the supernate are a concern for the disposal options being considered. It should be noted that the results of this study may not be representative of future decon frit solutions or sump/slurry solids samples. Therefore, future DWPF decisions regarding the possible disposal pathways for either the aqueous or solid portions of the Decon Frit system need to factor in the potential differences. More specifically, introduction of a different frit or changes to other DWPF flowsheet unit operations (e.g., different sludge batch or coupling with other process streams) may impact not only the results but also the conclusions regarding acceptability with respect to the ETF WAC limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗