Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stirling Cycle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Test results on parabolic dish concentrators for solar thermal power systems

This paper presents results of development testing of various solar thermal parabolic dish concentrators. The concentrators were mostly designed for the production of electric power using dish-mounted Rankine, Brayton or Stirling cycle engines, intended to be produced at low cost. Measured performance for various dishes included optical efficiencies ranging from 0.32 to 0.86 at a geometric concentration ratio of 500, and from about 0.09 to 0.85 at a geometric concentration ratio of 3000. Some malfunctions were observed. The tests should provide operating information of value in developing concentrators with improved performance and reduced maintenance.

Jaffe, Leonard D.↗

Requirements for long-life mechanical cryocoolers for space applications

The growing demand for long wavelength infrared and submillimeter imaging instruments for space observational applications, together with the emergence of the multiyear life Oxford University Stirling cycle cooler, has led to a rapidly expanding near term commitment to mechanical cryocoolers throughout the subkelvin to 150 K temperature range for long-life space missions. To satisfy this growing commitment, emerging cryocoolers must successfully address not only the input power, cooling power, and mass constraints of the spacecraft and instruments, but also the broad array of complex interface requirements that critically affect successful integration to the sensitive instrument detectors. Generic requirements are presented for each of the cryocooler requirement areas, which are then contrasted with the projected capabilities of emerging space cryocoolers. The degree of match is used to highlight both the strengths of existing technologies and the areas in need of increased development.

Ross, R. G., Jr.↗

SEI needs for space nuclear power

The use of nuclear electric propulsion (NEP) and nuclear thermal propulsion (NTP) for transportation to the moon and Mars is examined, and the use on Mars and moon bases of thermal conversion subsystems based on either a Brayton or a Stirling cycle is examined. It is shown that both cycles are attractive alternatives for those applications where continuous field operation is desired. Nuclear power systems have a clear advantage with regard to the moon and a lesser one with regard to Mars.

Brandhorst, H. W.↗

Oscillating-flow regenerator test rig: Woven screen and metal felt results

We present correlating expressions, in terms of Reynolds or Peclet numbers, for friction factors, Nusselt numbers, enhanced axial conduction ratios, and overall heat flux ratios in four porous regenerator samples representative of stirling cycle regenerators: two woven screen samples and two random wire samples. Error estimates and comparison of data with others suggest our correlations are reliable, but we need to test more samples over a range of porosities before our results will become generally useful.

Gedeon, D.↗

A review of pulse tube refrigeration

This paper reviews the development of the three types of pulse tube refrigerators: basic, resonant, and orifice types. The principles of operation are given. It is shown that the pulse tube refrigerator is a variation of the Stirling-cycle refrigerator, where the moving displacer is substituted by a heat transfer mechanism or by an orifice to bring about the proper phase shifts between pressure and mass flow rate. A harmonic analysis with phasors is described which gives reasonable results for the refrigeration power, yet is simple enough to make clear the processes which give rise to the refrigeration. The efficiency and refrigeration power are compared with those of other refrigeration cycles. A brief review is given of the research being done at various laboratories on both one- and two-stage pulse tubes. A preliminary assessment of the role of pulse tube refrigerators is discussed.

Radebaugh, Ray↗

Diaphragm Stirling cryocooler developments

This paper reports on the status of several ongoing development programs aimed at the demonstration of diaphragm Stirling cycle cryocooler performance. Key attributes of this technology focus on long reliable operating life and excellent efficiency, making it a candidate for cooling of satellite-borne long wavelength sensors for astrophysics and earth observing missions. Three programs are described, each leading to system or component test hardware: a 2 W 65 K single-stage Standard Spacecraft Cryocooler, a 300 mW 30 K two-stage cooler and a 200 mW 4-20 K single-stage cooler. Design features are described, and breadboard experimental data are presented.

Stacy, W. D.↗

Recent developments in Stirling and pulse tube coolers for spacecraft applications

Recent progress toward the development of light weight, long life coolers is presented. In particular, programs underway in the United States to develop Stirling cycle coolers and pulse tube coolers are described. The potential availability of reliable, long lifetime coolers for space applications is discussed.

Castles, Stephen↗

Ideal orifice pulse tube refrigerator performance

The recent development of orifice pulse tube refrigerators has raised questions as to what limits their ultimate performance. Using an analogy to the Stirling cycle refrigerator, the efficiency (cooling power per unit input power) of an ideal orifice pulse tube refrigerator is shown to be T1/T0, the ratio of the cold temperature to the hot temperature.

Kittel, P.↗

Heat pipe fatigue test specimen: Metallurgical evaluation

An innovative creep/fatigue test was run to simulate the temperature, mechanical load, and sodium corrosion conditions expected in a heat pipe designed to supply thermal energy to a Stirling cycle power converter. A sodium-charged Inconel 718 heat pipe with a Nickel 200 screen wick was operated for 1090 hr at temperatures between 950 K (1250 F) and 1050 K (1430 F) while being subjected to creep and fatigue loads in a servo-hydraulic testing machine. After testing, the heat pipe was sectioned and examined using optical microscopy, scanning electron microscopy, and electron microprobe analysis with wavelength dispersive x-ray spectroscopy. The analysis concentrated on evaluating topographic, microstructural, and chemical changes in the sodium exposed surfaces of the heat pipe wall and wick. Surface changes in the evaporator, condenser, and adiabatic sections of the heat pipe were examined in an effort to correlate the changes with the expected sodium environment in the heat pipe. This report describes the setup, operating conditions, and analytical results of the sodium heat pipe fatigue test.

Walak, Steven E.↗

Cryogenic Heat Pipe Experiment (CRYOHP)

The objective of the CRYOHP experiment is to conduct a shuttle experiment that demonstrates the reliable operation of two oxygen heat pipes in microgravity. The experiment will perform the following tasks: (1) demonstrate startup of the pipes from the supercritical state; (2) measure the heat transport capacity of the pipes; (3) measure evaporator and condenser film coefficients; and (4) work shuttle safety issues. The approach for the experiment is as follows: (1) fly two axially grooved oxygen heat pipes attached to mechanical stirling cycle tactical coolers; (2) integrate experiment in hitch-hiker canister; and (3) fly on shuttle and control from ground.

Mcintosh, Roy↗

Preliminary evaluation of a space AMTEC power conversion system

As original evaluation of a space solar energy source coupled with Alkali Metal Thermoelectric Conversion (AMTEC) is presented here. This study indicates that an AMTEC system would have 30 percent of the mass of a photovoltaic system and 70 percent of the mass of a Stirling cycle system at the 35-kWe level of power generation modules typical of the baseline for the U.S. Space Station. The operating temperatures and sodium heat pipe components for solar receiver/TES hardware (currently being developed by NASA) integrate well with AMTEC power conversion. AMTEC is therefore an attractive alternative specifically for space solar power generation.

Crowley, Christopher J.↗

Conceptual thermal design and analysis of a far-infrared/mid-infrared remote sensing instrument

This paper presents the conceptual thermal design and analysis results for the Spectroscopy of the Atmosphere using Far-Infrared Emission (SAFIRE) instrument. SAFIRE has been proposed for Mission to Planet Earth to study ozone chemistry in the middle atmosphere using remote sensing of the atmosphere in the far-infrared (21-87 microns) and mid-infrared (9-16 microns) spectra. SAFIRE requires that far-IR detectors be cooled to 3-4 K and mid-IR detectors to 80 K for the expected mission lifetime of five years. A superfluid helium dewar and Stirling-cycle cryocoolers provide the cryogenic temperatures required by the infrared detectors. The proposed instrument thermal design uses passive thermal control techniques to reject 465 watts of waste heat from the instrument.

Roettker, William A.↗

The X-ray Spectrometer - A cryogenic instrument on the Advanced X-ray Astrophysics Facility

The X-ray Spectrometer (XRS) is an instrument on the Advanced X-ray Astrophysics Facility (AXAF), the third of NASA's Great Observatories scheduled for launch in 1998. The XRS detectors have a resolution of approximately 10 eV over the range 0.3 - 10 keV. To achieve this resolution, the detectors are maintained at or below 0.1 Kelvin using an adiabatic demagnetization refrigerator inside a superfluid helium dewar. In addition, split-Stirling-cycle mechanical coolers are used to extend the anticipated on-orbit helium lifetime to a minimum of 4 years. This paper describes the challenges of developing this hybrid cryogenic system and presents an overview of the current design of the system.

Breon, Susan R.↗

Design of the cryogenic system for the SAFIRE instrument

One of the primary goals of the NASA Mission to Planet Earth is to improve understanding of the ozone chemistry of the atmosphere over an extended period of time. The Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) instrument is being developed to conduct, for the first time, global measurements of the key ozone chemistry constituents in both the mid- and far-infrared spectral regions. Such remote, long-term observations are made possible by the recent development of compact long-life hybrid cryogenic dewars which are necessary to cool the sensitive detectors to the 3-4 K range. The success of this hybrid concept is based on the use of long-life Stirling cycle cryocoolers to intercept parasitic heat from the internal radiation shields of the superfluid helium dewar. Extensive system trade studies are required to optimize the mass, power, and lifetime of these space-borne cryogenic systems. The SAFIRE Cryogenic Subsystem is described, including the thermal performance trades leading to the chosen system configuration and the important dewar/cryocooler interface issues.

Lee, J. H.↗

5-year lifetime hybrid superfluid helium dewar for the AXAF X-Ray Spectrometer (XRS)

The focal plane of the AXAF X-Ray Spectrometer requires an operating temperature of 0.1 K with a mission lifetime of 5 yrs. This demanding task is accomplished with a hybrid cryogenic subsystem consisting of mechanical coolers, a superfluid helium dewar and an adiabatic demagnetization refrigerator. By using mechanical coolers to remove heat from the dewar outer vapor-cooled shield, a 5-yr lifetime is achievable with only a 483-liter tank. This approach takes advantage of flight-proven, high-performance dewar technology and recent success in the development of split, Stirling-cycle mechanical coolers. Although the dewar design principles are similar to those used previously, parasitic heat flow is reduced to a new level by an optimized tension strap support system and careful attention to insulation system details. The benefit of the mechanical coolers is maximized by dewar interface design features that minimize parasitic heating and thermal impedance of the coupling. The dewar design and thermal performance analysis are discussed. Helium lifetime sensitivities and the effects of mechanical cooler failures are predicted.

Nieczkoski, Stephen J.↗

Three-Stage Regenerative Sorption Cooler Reaches 65 K

Three-stage regenerative sorption cooler produces no measurable vibration, highly reliable, and exhibits efficiency comparable to that of less-reliable mechanical Stirling-cycle cooler. Represents improvement over two-stage sorption cooler described in "Regenerative Sorption Refrigerator" (NPO-17630).

Bard, Steven↗

Digital control of magnetic bearings in a cryogenic cooler

This paper describes the design of a digital control system for control of magnetic bearings used in a spaceborne cryogenic cooler. The cooler was developed by Philips Laboratories for the NASA Goddard Space Flight Center. Six magnetic bearing assemblies are used to levitate the piston, displacer, and counter-balance of the cooler. The piston and displacer are driven by linear motors in accordance with Stirling cycle thermodynamic principles to produce the desired cooling effect. The counter-balance is driven by a third linear motor to cancel motion induced forces that would otherwise be transmitted to the spacecraft. An analog control system is currently used for bearing control. The purpose of this project is to investigate the possibilities for improved performance using digital control. Areas for potential improvement include transient and steady state control characteristics, robustness, reliability, adaptability, alternate control modes, size, weight, and cost. The present control system is targeted for the Intel 80196 microcontroller family. The eventual introduction of application specific integrated circuit (ASIC) technology to this problem may produce a unique and elegant solution both here and in related industrial problems.

Feeley, J.↗

Three-stage linear, split-Stirling cryocooler for 1 to 2K magnetic cold stage

A long-life, linear, high efficiency 8K split Stirling cycle cryocooler was designed, built, and tested. The refrigerator is designed for cooling a 50 mW, 1.5K magnetic cold stage. Dual opposed piston compressors are driven by moving-coil linear motors. The three stage expander, although not completed, is also driven by a linear motor and is designed to produce 1 SW at 60K, 4W at 16K, and 1.2W at 8K. The cold regenerator employs a parallel gap construction for high efficiency. The key technology areas addressed include warm and cold flexible suspension bearings and a new cold regenerator geometry for high efficiency at 8K.

Longsworth, R. C.↗