Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Quantitative Uncertainty Analysis for Diffraction

Current software uses a least squares statistical method. For each model parameter, current software yields a point estimate and estimated standard error for each point estimate. In contrast, we have employed a Bayesian approach with sampling algorithm to provide a full posterior probability density function on each model parameter. This yields a different type of solution (probabilistic) with better fidelity. The Quantitative Uncertainty Analysis for Diffraction (QUAD) package returns a matrix of affect model parameters as a function of iteration through the MCMC analysis. QUAD is a Python code that allows for analysis of X-ray and neutron diffraction data to infer the structure of materials with quantifiable certainty. The code uses Bayesian statistics and Markov chain sampling algorithms to create posterior probability distributions on all material structure parameters that are modeled by a researcher. The statistical packages use the open source GSASII project as a library to calculate model diffraction patterns.

Fancher, ChristopherM↗

SDSS-II: Determination of shape and color parameter coefficients for SALT-II fit model

In this study we look at the SALT-II model of Type IA supernova analysis, which determines the distance moduli based on the known absolute standard candle magnitude of the Type IA supernovae. We take a look at the determination of the shape and color parameter coefficients, {alpha} and {beta} respectively, in the SALT-II model with the intrinsic error that is determined from the data. Using the SNANA software package provided for the analysis of Type IA supernovae, we use a standard Monte Carlo simulation to generate data with known parameters to use as a tool for analyzing the trends in the model based on certain assumptions about the intrinsic error. In order to find the best standard candle model, we try to minimize the residuals on the Hubble diagram by calculating the correct shape and color parameter coefficients. We can estimate the magnitude of the intrinsic errors required to obtain results with {chi}{sup 2}/degree of freedom = 1. We can use the simulation to estimate the amount of color smearing as indicated by the data for our model. We find that the color smearing model works as a general estimate of the color smearing, and that we are able to use the RMS distribution in the variables as one method of estimating the correct intrinsic errors needed by the data to obtain the correct results for {alpha} and {beta}. We then apply the resultant intrinsic error matrix to the real data and show our results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of Deposition© software predictions to published experimental results for large (152 mm by 152 mm) square ducts

A comparison was performed between experimental aerosol deposition measurements in large air ducts, compared to predictions performed by the US Nuclear Regulatory Commission Deposition© software package. Although the Deposition© code was designed to calculate the transport of radioactive aerosols in small diameter sampling tubes, it was not certain that the software would adequately predict aerosol transport in large air ducts. Two sets of experimental data were used in this comparison, one set of results from small diameter (1.27 mm ID) tubes, and the other data set was from testing on large diameter (152 mm square) ventilation ducts. In general, the Deposition© software performs excellent predictions if the ductwork system has a computed aerosol percent penetration greater than 75% (with a 2.9% average error compared to experiments). For example, shorter duct systems have higher aerosol penetrations than a longer duct system of the same diameter. However, when the Deposition© software calculated an aerosol penetration less than about 75% for a particular duct system, the average percent error increased to 68.3% when compared to experimental measurements. The Deposition© software could therefore be used to ensure that an aerosol would have a high percent penetration through a ductwork system, but it should not be used to make (dosimetric) decisions about ductwork performance if the calculated percent penetration is less than 75%. This document includes a section of attached engineering formulas that explain the structure of the Excel spreadsheet calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sensitivity analysis on optical performance of a novel linear Fresnel concentrating solar power collector

A novel, low-cost linear Fresnel collector for concentrating solar power applications is being developed by Hyperlight Energy (Hyperlight) and the National Renewable Energy Laboratory (NREL). Hyperlight is currently deploying their linear Fresnel collector technology in a half-acre pilot loop near Brawley, California. The optical performance of a concentrating solar power collector represents the largest loss in the efficiency of the overall system. The ability to accurately model the complex optical interactions of a collector becomes essential in successfully implementing a new collector technology. Here, this study presents a detailed sensitivity analysis of the optical performance of Hyperlight linear Fresnel technology, characterizing the effects of potential optomechanical error sources on collector performance. Optical models are implemented in SolTrace, a Monte-Carlo ray-tracing software developed at NREL. First, SolTrace is used to analyze collector sensitivity to individual optomechanical error perturbations in both the primary reflectors and the receiver assembly. Then, a high-fidelity optomechanical error model is adopted to capture the realistic performance of the installed Hyperlight linear Fresnel collector. Finally, the sensitivity analysis can provide insightful guidance to inform the tightening and relaxation of tolerances during manufacturing and implementation of a new collector technology.

14 SOLAR ENERGY↗

Development of Fusion Neutronics Methodology, Software, and Testing Facility in FDS Team

Fusion neutronics including methodology, software, experiments, etc. is studied concerning the generation, utilizing and protection of neutrons in fusion facilities. Achievements have been made in the past decades to solve the new problems fusion neutronics. However there is still some way to go such as following. Automatic modeling method based on CAD has been developed to avoid the heavy burden of manual geometry description. The pre-processing costs much time to simplify the CAD model for converting to Constructive Solid Geometry (CSG), 2D or 3D mesh based geometry. This problem has become a new focus. Deep penetration of radiation shielding is notable problem for fusion. Adaptive variance reduction methods such as Consistent Adjoint Driven Importance Sampling (CADIS) were developed to accelerate convergence. However the gap still exists between engineering requirements and current methodology. The geometry simplification, homogenizing based tally, error in nuclear data and error propagation in coupled calculation, etc., causes considerable uncertainty, which leads to 'safety factor' applied in simulation results to achieve required safety margin. It can significantly raise the cost and even makes it impractical to initiate the fusion facilities. Uncertainty qualification, error analysis and error propagation problem should be studied. New methodology and software should be validated. For example the (n,p), (n,a), (n,t) cross section of Cu, Fe, W, Ni which is important for evaluation of material radiation damage is absent. The validation of neutronics properties of special components such as first wall, blanket and coil are needed. The D-T fusion neutron generator can directly represent the neutron environment in fusion reactors. However the neutron yield is several orders of magnitudes lower than requirements. To resolve obstacles in fusion neutronics, broad improvements of methodology, software and testing facility have been achieved by FDS Team in recent years and the main progress was introduced in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Code Coverage Status of ARC Code-DIF3D

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. DIF3D plays a pivotal role in the ARC system as the primary homogenized assembly neutronic calculation methodology for fast reactor problems. Over its 40 years history, ARC software usage with DIF3D has been applied to numerous fast and thermal spectrum reactor analysis projects with good to excellent comparison against experiments. With continued improvement of computation resources, many of the geometry modeling capabilities in DIF3D that were primarily used in low order schemes are not really needed anymore. Today, the diffusion and transport capabilities of DIF3D-VARIANT are primarily used in the reactor design process with some scattered usage of DIF3D-FD and DIF3D-Nodal. In recent work, the DIF3D software verification was completed for DIF3D-FD and DIF3D-VARIANT on the geometry options used in the Versatile Test Reactor project. While we can be confident that these capabilities of DIF3D are well used and thus trusted, it does not demonstrate that all possible input options of DIF3D are actually working, but just those that were tested as part of VTR are and that they are correct. Thus, the purpose of the present work is to identify a set of test problems for DIF3D and assess the code coverage of DIF3D for those test problems. The goal is to document what parts of the existing DIF3D code are touched by the set of test problems and which are not. Because the verification work done on DIF3D-VARIANT and DIF3D-FD was focused on the most common uses of DIF3D for fast reactor analysis, the code coverage assessment of those capabilities is the highest priority. This will ensure that nothing is being missed by the existing verification test problems that DIF3D relies upon. The DIF3D-Nodal capability will also be inspected for code coverage as part of this work to further ensure that regular regression testing of DIF3D will trap any likely errors the end user might experience with the DIF3D software. The code coverage analysis of DIF3D was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of DIF3D. The detailed coverage tables are given for each submodule of DIF3D separately, and for the submodules which are primarily developed for DIF3D, most of the source files could be at least partially touched. Most of the uncovered parts/files could be easily ignored, because they are either for error message and debugging output or obviously not needed by DIF3D. Out of the entire source codes of DIF3D, only a few uncovered modules deserve further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Code Coverage Status of the ARC Code DIF3D

The Argonne Reactor Code (ARC) software system supports users in their fast reactor design goals by providing neutronic, thermal-hydraulic, and structural analysis capabilities. DIF3D plays a pivotal role in the ARC system as the primary homogenized assembly neutronic calculation methodology for fast reactor problems. Over its 40 years history, ARC software usage with DIF3D has been applied to numerous fast and thermal spectrum reactor analysis projects with good to excellent comparison against experiments. With continued improvement of computation resources, many of the geometry modeling capabilities in DIF3D that were primarily used in low order schemes are not really needed anymore. Today, the diffusion and transport capabilities of DIF3D-VARIANT are primarily used in the reactor design process with some scattered usage of DIF3D-FD and DIF3D-Nodal. In recent work, the DIF3D software verification was completed for DIF3D-FD and DIF3D-VARIANT on the geometry options used in the Versatile Test Reactor project. While we can be confident that these capabilities of DIF3D are well used and thus trusted, it does not demonstrate that all possible input options of DIF3D are actually working, but just those that were tested as part of VTR are and that they are correct. Thus, the purpose of the present work is to identify a set of test problems for DIF3D and assess the code coverage of DIF3D for those test problems. The goal is to document what parts of the existing DIF3D code are touched by the set of test problems and which are not. Because the verification work done on DIF3D-VARIANT and DIF3D-FD was focused on the most common uses of DIF3D for fast reactor analysis, the code coverage assessment of those capabilities is the highest priority. This will ensure that nothing is being missed by the existing verification test problems that DIF3D relies upon. The DIF3D-Nodal capability will also be inspected for code coverage as part of this work to further ensure that regular regression testing of DIF3D will trap any likely errors the end user might experience with the DIF3D software. The code coverage analysis of DIF3D was performed with the Code Coverage Tool of the Intel Fortran compiler which requires modifications to the compilation of DIF3D. The detailed coverage tables are given for each submodule of DIF3D separately, and for the submodules which are primarily developed for DIF3D, most of the source files could be at least partially touched. Most of the uncovered parts/files could be easily ignored, because they are either for error message and debugging output or obviously not needed by DIF3D. Out of the entire source codes of DIF3D, only a few uncovered modules deserve further investigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lazy Shadowing - An Adaptive, Power-Aware, Resiliency Framework for Extreme Scale Computing

The major goal of the project was to examine the problem of resilience in exascale systems via mechanisms that minimize the impact of server crashes resulting from both permanent faults and transient errors or subtle time-dependent bugs in hardware or software. Shadowing was proposed as the main technique for accomplishing this in the proposal, wherein some replicas of the application are run at much lower power and opportunistically speeded up during periods of low activity of the main or when the main fails. A related goal of the project was to detect the errors early so that program crashes could be avoided or the scope of the rollbacks could be limited.

97 MATHEMATICS AND COMPUTING↗

FInd Gas Source

FIGS is a neural network software that ingests real time synchronized field data on environmental flow fields and turbulence and gas concentration variations at high frequency and uses an error minimization algorithm to locate the gas source and quantify its strength. The software can be interfaced with atmospheric, oceanic and subsurface instruments in a variety of platforms stationary or mobile (e.g. cars, UAVs, submersible vehicles or boreholes) and used to find gas sources by smart use of data and phenomenology. FIGS can be trained by phenomenological model of the flow fields in the environment of interest and/or be calibrated by controlled release. After initial deployment the FIGS learning will grow with time as it accumulates data on source quantification. FIGS can be installed on any computer from small beagle-bones for field deployment/end-use to PC/MACs/main-frame for training/analysis. FIGS has been trained (using LANL's high resolution atmospheric simulations) and calibrated, tested and evaluated in the field and shown to perform well in finding and quantifying methane leaks at 10-100m scales at well pads by ingesting atmospheric measurements. The code is applicable to gas and particle source location at large scales.

Travis, Bryan↗

Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images

Purpose: To assess the accuracy of the commercially available deformable image registration (DIR) software for thoracic images at multiple institutions. Methods and Materials: Thoracic 4-dimensional (4D) CT images of 10 patients with esophageal or lung cancer were used. Datasets for these patients were provided by DIR-lab ( (dir-lab.com)) and included a coordinate list of anatomic landmarks (300 bronchial bifurcations) that had been manually identified. Deformable image registration was performed between the peak-inhale and -exhale images. Deformable image registration error was determined by calculating the difference at each landmark point between the displacement calculated by DIR software and that calculated by the landmark. Results: Eleven institutions participated in this study: 4 used RayStation (RaySearch Laboratories, Stockholm, Sweden), 5 used MIM Software (Cleveland, OH), and 3 used Velocity (Varian Medical Systems, Palo Alto, CA). The ranges of the average absolute registration errors over all cases were as follows: 0.48 to 1.51 mm (right-left), 0.53 to 2.86 mm (anterior-posterior), 0.85 to 4.46 mm (superior-inferior), and 1.26 to 6.20 mm (3-dimensional). For each DIR software package, the average 3-dimensional registration error (range) was as follows: RayStation, 3.28 mm (1.26-3.91 mm); MIM Software, 3.29 mm (2.17-3.61 mm); and Velocity, 5.01 mm (4.02-6.20 mm). These results demonstrate that there was moderate variation among institutions, although the DIR software was the same. Conclusions: We evaluated the commercially available DIR software using thoracic 4D-CT images from multiple centers. Our results demonstrated that DIR accuracy differed among institutions because it was dependent on both the DIR software and procedure. Our results could be helpful for establishing prospective clinical trials and for the widespread use of DIR software. In addition, for clinical care, we should try to find the optimal DIR procedure using thoracic 4D-CT data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Synoptic VLBI Technique for Localizing Nonrepeating Fast Radio Bursts with CHIME/FRB

We demonstrate the blind interferometric detection and localization of two fast radio bursts (FRBs) with subarcminute precision on the 400 m baseline between the Canadian Hydrogen Intensity Mapping Experiment (CHIME) and the CHIME Pathfinder. In the same spirit as Very Long Baseline Interferometry (VLBI), the telescopes were synchronized to separate clocks, and the channelized voltage (herein referred to as baseband) data were saved to a disk with correlation performed offline. The simultaneous wide field of view and high sensitivity required for blind FRB searches implies a high data rate—6.5 terabits per second (Tb/s) for CHIME and 0.8 Tb s{sup −1} for the Pathfinder. Since such high data rates cannot be continuously saved, we buffer data from both telescopes locally in memory for ≈40 s, and write to the disk upon receipt of a low-latency trigger from the CHIME Fast Radio Burst Instrument (CHIME/FRB). The ≈200 deg{sup 2} field of view of the two telescopes allows us to use in-field calibrators to synchronize the two telescopes without needing either separate calibrator observations or an atomic timing standard. In addition to our FRB observations, we analyze bright single pulses from the pulsars B0329+54 and B0355+54 to characterize systematic localization errors. Our results demonstrate the successful implementation of key software, triggering, and calibration challenges for CHIME/FRB Outriggers: cylindrical VLBI outrigger telescopes which, along with the CHIME telescope, will localize thousands of single FRB events with sufficient precision to unambiguously associate a host galaxy with each burst.

47 OTHER INSTRUMENTATION↗

SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system safer than before.

60 APPLIED LIFE SCIENCES↗

3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification

Purpose: To evaluate methods of pretreatment IMRT analysis, using real measurements performed with a commercial 2D detector array, for clinical relevance and accuracy by comparing clinical DVH parameters. Methods: We divided the work into two parts. The first part consisted of six in-phantom tests aimed to study the sensitivity of the different analysis methods. Beam fluences, 3D dose distribution, and DVH of an unaltered original plan were compared to those of the delivered plan, in which an error had been intentionally introduced. The second part consisted of comparing gamma analysis with DVH metrics for 17 patient plans from various sites. Beam fluences were measured with the MapCHECK 2 detector, per-beam planar analysis was performed with the MapCHECK software, and 3D gamma analysis and the DVH evaluation were performed using 3DVH software. Results: In a per-beam gamma analysis some of the tests yielded false positives or false negatives. However, the 3DVH software correctly described the DVH of the plan which included the error. The measured DVH from the plan with controlled error agreed with the planned DVH within 2% dose or 2% volume. We also found that a gamma criterion of 3%/3 mm was too lax to detect some of the forced errors. Global analysis masked some problems, while local analysis magnified irrelevant errors at low doses. Small hotspots were missed for all metrics due to the spatial resolution of the detector panel. DVH analysis for patient plans revealed small differences between treatment plan calculations and 3DVH results, with the exception of very small volume structures such as the eyes and the lenses. Target coverage (D{sub 98} and D{sub 95}) of the measured plan was systematically lower than that predicted by the treatment planning system, while other DVH characteristics varied depending on the parameter and organ. Conclusions: We found no correlation between the gamma index and the clinical impact of a discrepancy for any of the gamma index evaluation possibilities (global, local, 2D, or 3D). Some of the tests yielded false positives or false negatives in a per-beam gamma analysis. However, they were correctly accounted for in a DVH analysis. We also showed that 3DVH software is reliable for our tests, and is a viable method for correlating planar discrepancies with clinical relevance by comparing the measured DVH of target and OAR's with clinical tolerance.

60 APPLIED LIFE SCIENCES↗

A quantification of the effectiveness of EPID dosimetry and software-based plan verification systems in detecting incidents in radiotherapy

Purpose: Complex treatments in radiation therapy require robust verification in order to prevent errors that can adversely affect the patient. For this purpose, the authors estimate the effectiveness of detecting errors with a “defense in depth” system composed of electronic portal imaging device (EPID) based dosimetry and a software-based system composed of rules-based and Bayesian network verifications. Methods: The authors analyzed incidents with a high potential severity score, scored as a 3 or 4 on a 4 point scale, recorded in an in-house voluntary incident reporting system, collected from February 2012 to August 2014. The incidents were categorized into different failure modes. The detectability, defined as the number of incidents that are detectable divided total number of incidents, was calculated for each failure mode. Results: In total, 343 incidents were used in this study. Of the incidents 67% were related to photon external beam therapy (EBRT). The majority of the EBRT incidents were related to patient positioning and only a small number of these could be detected by EPID dosimetry when performed prior to treatment (6%). A large fraction could be detected by in vivo dosimetry performed during the first fraction (74%). Rules-based and Bayesian network verifications were found to be complimentary to EPID dosimetry, able to detect errors related to patient prescriptions and documentation, and errors unrelated to photon EBRT. Combining all of the verification steps together, 91% of all EBRT incidents could be detected. Conclusions: This study shows that the defense in depth system is potentially able to detect a large majority of incidents. The most effective EPID-based dosimetry verification is in vivo measurements during the first fraction and is complemented by rules-based and Bayesian network plan checking.

60 APPLIED LIFE SCIENCES↗

Xavier: High-Performance X-Drop Adaptive Banded Pairwise Alignment (Xavier) v1.0

Pairwise sequence alignment is one of the most compute-intense challenges for the analysis of genomics data and it can account for more than 90% of the runtime depending on the application. Despite the effort to reduce the computational cost introducing heuristics such as banded and x-drop alignment, the performance of state-of-the-art software is often unsatisfactory for long sequences. Recent advances in single-molecule sequencing technologies keep increasing the length of the sequences to align at the cost of higher error rates b ranging from 5% to 15% b, emphasizing the need for fast and accurate software. Our long-read alignment software, named Xavier, computes high-performance x-drop adaptive banded pairwise alignment exploiting instruction-level parallelism via Single-Instruction-Multiple-Data (SIMD) operations. Xavier uses a narrow bandwidth that appreciably improves performance reducing the search space for the optimal alignment. In our experiment, the adaptive mechanism enables Xavier to find the optimal alignment between related sequences even when the error rate is as high as 50%. Xavier achieves speed-up up to 5X over competitor software when enabling the x-drop termination and up to 415X when disabling it, with negligible accuracy loss.

Guidi, Giulia↗

Uncertainty Analysis and Software Verification

Uncertainty analyses are an important part of calibrations and testing. They allow researchers insight on how to reduce and mitigate errors in testing. Each device used in testing introduces error in a system, as well as other sources such as environmental conditions, electronics, analog to digital, and random errors. Each source is carefully examined to identify how much error it introduces to a system. These sources are then combined using various methods of uncertainty calculations. To verify and validate software, a manual calculation is required to ensure the software is performing as intended. Using Excel to verify the calculations, we can identify discrepancies within the software. The root of the sum of the squares uncertainty (RSS) is used to find the combined uncertainty of a device at one and two standard deviations of the mean. Calibrations on accelerometers are performed using a vibration system along with a back-toback reference accelerometer. The vibration system takes a reference point at 100Hz frequency at 10g amplitude. The sensitivities are collected at each dialed in frequency. The sensitivity of the device represents the electrical output of the UUT (mV, pC, etc.) per unit of acceleration (g). The full history of sensitivities of selected accelerometers are used to find the averaged, standard deviation, and uncertainty of the device at each frequency tested. The uncertainty calculations from excel and the software are then compared.

97 MATHEMATICS AND COMPUTING↗

Data acquisition and control software for XRD beamline at Indus-2

X-ray diffraction (XRD) beamline is under commissioning on Indus-2 synchrotron radiation facility. The experimental setup of XRD beamline consists of a six-circle diffractometer and various detector systems such as scintillation detector, ionization chamber and image plate. The diffractometer can be controlled via EIA232 serial interface or Ethernet. Standard data acquisition software with a graphical user interface has been developed using LabVIEW. A firm safety and error handling scheme is implemented for failsafe operation of the experimental station. This paper describes in detail the data acquisition and control software for the experimental station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualization Quality Assessment

Understanding how inaccuracies in visualizations affect users’ perception and understanding of scientific data is hard. Inaccuracies in visualizations are quite common and could arise from a range of sources such as errors in the original dataset arising from compression artifacts, errors in the capturing device, noise during transmission of the data, effects due to the algorithm being used to convert data to visualization images, images generated from neural networks, and sources we have yet to discover. Many image quality assessment metrics have been developed to quantify image errors. However, these are usually focused on “natural images” rather than visualizations of scientific data. Common image quality assessment metrics (IQAs) include MSE, PSNR, perceptual metrics such SSIM, FSIM as well as perceptual metrics using deep learning approaches. However, a critical part of understanding how errors are perceived by humans, and subsequently developing more accurate quality assessment metrics, is through user evaluation studies. The goal of this software is to develop a visualization quality assessment (VQA) process that will enable the generation of VQAs that can be used to quantify errors in scientific data visualizations. The VQA development process will include software to support user evaluation experimental design, analysis of visualization differences against standard quality metrics, and the ability to develop additional VQA metrics specific to scientific visualization images.

Grosset, Andre↗