Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Smart buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low Carbon Technology Strategies: Stand-Alone Retail and Strip Mall

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon retail buildings within their existing building portfolios. Stand-alone retail and strip malls often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Smart thermostat data-driven U.S. residential occupancy schedules and development of a U.S. residential occupancy schedule simulator

Occupancy schedule is one of the key inputs in Building Energy Modeling (BEM) to reflect the interaction between buildings and occupants. Over the past decades, standardized occupancy schedules, developed mainly by engineering rule-of-thumb, have been widely used in BEM due to its simplicity and lack of real measured occupancy data. However, the BEM community has recognized their association with uncertainty and reliability in simulation results from BEM. This study introduces representative occupancy schedules in the U.S. residential buildings, derived from a large smart thermostat dataset and time-series K-means clustering, and an open-source tool to generate a stochastic residential occupancy schedule. Over 90,000 residential occupancy schedules were estimated from the ecobee Donate Your Data dataset. Then, the representative occupancy schedules were identified through clustering. This study further investigated the impacts of three parameters (day, house type, and state) on residential occupancy schedules. Then, a tool, the Residential Occupancy Schedule Simulator (ROSS), is developed using the representative occupancy schedules derived in this study. Details of this tool are presented in this paper. In conclusion, the derived representative occupancy schedules and the ROSS tool can help improve the energy modeling of residential buildings.

42 ENGINEERING↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Modeling Workflow to Generate Representative Geologic Variability in Training Dataset for SMART Initiative

The poster discusses the modeling workflow to generate ensemble of geologic realizations of the Illinois Basin Decatur Project (IBDP) site, based on available site characterization data and inherent uncertainty of those data, for use by project collaborators in DOE SMART Initiative (Phase 2) to build their forward modeling, history matching, and optimization workflows. This poster is summarized from the technical report for the SMART project submitted to U.S. DOE earlier this year.

Ganesh, Priya Ravi↗

Natural Gas Community of the Future (Final Report)

Nicor Gas, a subsidiary of Southern Company Gas and its parent company Southern Company, is developing the concept of the Carbon-neutral, Affordable, Resilient, and Equitable Community ("CARE Community") to address the challenges of accessibility and affordability of grid-interactive efficient buildings in historically disadvantaged communities. The CARE Community is a new construction net-zero energy and carbon neutral residential neighborhood consisting of 50 homes with electricity and natural gas services in South Suburban Chicago, built as low-income affordable housing. The National Renewable Energy Laboratory (NREL) is assisting Southern Company to explore how energy efficiency, renewable technologies, and the reliability and resilience of natural gas can be combined and optimized in an islandable energy system as part of a broader effort to understand the role natural gas plays in future communities integrated with renewable energy and improved energy efficiency. The CARE Community will demonstrate how energy efficiency, distributed energy resources (DERs), and advanced controls can be combined with existing natural gas infrastructure to serve historically disadvantaged communities in a cold climate with low energy cost for affordable housing programs and enhanced resilience to withstand extreme weather. Homes will be a part of an islandable energy system, integrating multiple DER technologies such as solar panels, natural gas fuel cells, reciprocating natural gas engines, and battery storage. The CARE Community will provide a replicable template that affordable housing developers and energy companies can adopt throughout the United States. In this report, we present the design and modeling of the community and potential approaches for integrating DERs. We analyze and discuss annual simulations under normal operating conditions and week-long simulations under electric power grid outage conditions.

03 NATURAL GAS↗

Low Carbon Technology Strategies: Large Office

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon large office buildings within their existing building portfolios. Large offices are typically over 50,000 square feet and often include complex heating and cooling systems.

analytics↗

Low Carbon Technology Strategies: Small Office

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon small office buildings within their existing building portfolios. Small offices are typically less than 50,000 square feet and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Midrise Apartment

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon midrise apartment buildings within their existing building portfolios. Midrise apartments may use packaged rooftop units for heating, cooling, and ventilation or central plant systems for larger buildings.

analytics↗

Low Carbon Technology Strategies: Outpatient Healthcare

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon outpatient healthcare buildings within their existing building portfolios. Outpatient healthcare includes diagnostic and treatment facilities for outpatient care, and these buildings often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Cost Reduction of School Bus Fleet Electrification With Optimized Charging and Distributed Energy Resources: Preprint

Considerations for electrifying school buses are presented with an analysis of battery sizing to match bus driving requirements. The charging and vehicle-to-building dispatch of the electric school buses were optimized to evaluate the potential to reduce the impact of the bus charging on the school's electric utility bill. Distributed energy resources (DER) and flexible building loads were also considered with the school bus electrification to evaluate the further reduction in energy costs with enhanced system integration and optimized dispatch. The effect of degradation on the school bus batteries was analyzed to determine if the smart charging and vehicle-to-building battery operation decreases the life of the battery. The results show that there is an opportunity to mitigate the increase of electric utility bills with improved charging controls and bi-directionally operating the school bus batteries to reduce building demand charges. The battery degradation analysis using dispatch with optimized charging and discharging shows acceptable battery life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Considerations and Research Pathways for Grid-Interactive Efficient Buildings

Federal facilities serve critical missions and functions that require safe, reliable, and efficient operations. Digitization of several facility operations has increased the cost-effectiveness of energy usage and optimization of energy system performance. As the building controls landscape shifts to become more connected and smarter, building operators now face unique opportunities and challenges to adopt smart enabled devices that can lower energy usage while also optimizing building system performance. The grid-interactive efficient buildings (GEB) initiative aims to make buildings cleaner and more flexible through these smart devices. Smart enabled devices allow greater connectivity and control through remote operations and provide crucial data for analytics and increased efficiency. GEBs enable demand flexibility that has the potential to reduce electrical costs and transform the grid edge where buildings connect to power grids. This operation of interconnected systems, if not designed with cybersecurity practices, causes security gaps and introduces potential attack paths by adversarial and non-adversarial entities leading to disruption of operations.

building controls↗

Low Carbon Technology Strategies: Supermarket

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon supermarkets within their existing building portfolios. Supermarkets include built-up refrigeration systems and refrigerated display cases and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Hospital

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon hospitals within their existing building portfolios. Hospitals typically include complex heating and cooling systems and specialty medical equipment.

analytics↗

Preparing large area of thermochromic nanocomposite films for smart window application

The challenges posed by high building energy bill necessitate proactive implementation of energy-efficient strategies to minimize the uses of both electricity and heating gas and promote the use of free solar energy sources. "Smart" window films/glass, leveraging thermochromic vanadium dioxide (VO 2 ), offer an adaptive approach to harness solar energy, significantly reducing the thermal load of buildings. This is achieved by reflecting the infrared portion of the solar spectrum through a phase transition in the monoclinic M-phase (M) of VO 2 induced by heating. In this study, a scalable continuous flow synthesis process invented by Argonne was employed to explore a wide parameter space, targeting the controlled synthesis of monoclinic VO 2 (M) nanoparticles with well-controlled sizes and morphologies. Additionally, a doping strategy and surface modifications were utilized for high-throughput tuning of the metal-to-insulator transition temperature. Strategies to enhance the solar modulation properties of VO 2 nanoparticles in polymer films were investigated through (i) morphological transformation from spherical to nanorod structures, (ii) surface modification with low refractive index ligands, and (iii) incorporation of additional thermochromic materials for improved solar energy modulation and aesthetically appealing colors in smart films. Furthermore, the study outlines scaling-up synthesis methods for VO 2 nanoparticles in a continuous flow reactor using hydrazine monohydrate. This comprehensive investigation provides valuable insights into the upscaling synthesis and design of advanced VO 2 /polymer composite smart window films with enhanced functionality, solar energy modulation and visible light transmittance, driving the technology a step close for industrial application.

14 SOLAR ENERGY↗

A guideline to document occupant behavior models for advanced building controls

The availability of computational power, and a wealth of data from sensors have boosted the development of model-based predictive control for smart and effective control of advanced buildings in the last decade. More recently occupant-behavior models have been developed for including people in the building control loops. However, while important objectives of scientific research are reproducibility and replicability of results, not all information is available from published documents. Therefore, the aim of this paper is to propose a guideline for a thorough and standardized occupant-behavior model documentation. For that purpose, the literature screening for the existing occupant behavior models in building control was conducted, and the occupant behavior modeling processes were studied to extract practices and gaps for each of the following phases: problem statement, data collection, and preprocessing, model development, model evaluation, and model implementation. Here, the literature screening pointed out that the current state-of-the-art on model documentation shows little unification, which poses a particular burden for the model application and replication in field studies. In addition to the standardized model documentation, this work presented a model-evaluation schema that enabled benchmarking of different models in field settings as well as the recommendations on how OB models are integrated with the building system.

Building control↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗