Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Small object detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

AN IN-DEPTH VIEW OF THE MID-INFRARED PROPERTIES OF POINT SOURCES AND THE DIFFUSE ISM IN THE SMC GIANT H II REGION, N66

The focus of this work is to study mid-infrared point sources and the diffuse interstellar medium (ISM) in the low-metallicity ({approx}0.2 Z{sub Sun }) giant H II region N66 in order to determine properties that may shed light on star formation in these conditions. Using the Spitzer Space Telescope's Infrared Spectrograph, we study polycyclic aromatic hydrocarbon (PAH), dust continuum, silicate, and ionic line emission from 14 targeted infrared point sources as well as spectra of the diffuse ISM that is representative of both the photodissociation regions (PDRs) and the H II regions. Among the point source spectra, we spectroscopically confirm that the brightest mid-infrared point source is a massive embedded young stellar object, we detect silicates in emission associated with two young stellar clusters, and we see spectral features of a known B[e] star that are commonly associated with Herbig Be stars. In the diffuse ISM, we provide additional evidence that the very small grain population is being photodestroyed in the hard radiation field. The 11.3 {mu}m PAH complex emission exhibits an unexplained centroid shift in both the point source and ISM spectra that should be investigated at higher signal-to-noise and resolution. Unlike studies of other regions, the 6.2 {mu}m and 7.7 {mu}m band fluxes are decoupled; the data points cover a large range of I{sub 7.7}/I{sub 11.3} PAH ratio values within a narrow band of I{sub 6.2}/I{sub 11.3} ratio values. Furthermore, there is a spread in PAH ionization, being more neutral in the dense PDR where the radiation field is relatively soft, but ionized in the diffuse ISM/PDR. By contrast, the PAH size distribution appears to be independent of local ionization state. Important to unresolved studies of extragalactic low-metallicity star-forming regions, we find that emission from the infrared-bright point sources accounts for only 20%-35% of the PAH emission from the entire region. These results make a comparative data set to other star-forming regions with similarly hard and strong radiation fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for gamma-ray emission from dark matter annihilation in the Small Magellanic Cloud with the Fermi Large Area Telescope

The Small Magellanic Cloud (SMC) is the second-largest satellite galaxy of the Milky Way and is only 60 kpc away. As a nearby, massive, and dense object with relatively low astrophysical backgrounds, it is a natural target for dark matter indirect detection searches. In this work, we use six years of Pass 8 data from the Fermi Large Area Telescope to search for gamma-ray signals of dark matter annihilation in the SMC. Using data-driven fits to the gamma-ray backgrounds, and a combination of N-body simulations and direct measurements of rotation curves to estimate the SMC DM density profile, we found that the SMC was well described by standard astrophysical sources, and no signal from dark matter annihilation was detected. We set conservative upper limits on the dark matter annihilation cross section. Furthermore, these constraints are in agreement with stronger constraints set by searches in the Large Magellanic Cloud and approach the canonical thermal relic cross section at dark matter masses lower than 10 GeV in the bb¯ and τ + τ - channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-DE-207A-00: Advances in Image-Guided Neurointerventions-Clinical Pull and Technology Push

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-01: Parallels in the Evolution of X-Ray Angiographic Systems and Devices Used for Minimally Invasive Endovascular Therapy

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-03: Recent Advances in Devices Used in Neuro--Interventions

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

1. Parallels in the evolution of x-ray angiographic systems and devices used for minimally invasive endovascular therapy Charles Strother - DSA, invented by Dr. Charles Mistretta at UW-Madison, was the technology which enabled the development of minimally invasive endovascular procedures. As DSA became widely available and the potential benefits for accessing the cerebral vasculature from an endovascular approach began to be apparent, industry began efforts to develop tools for use in these procedures. Along with development of catheters, embolic materials, pushable coils and the GDC coils there was simultaneous development and improvement of 2D DSA image quality and the introduction of 3D DSA. Together, these advances resulted in an enormous expansion in the scope and numbers of minimally invasive endovascular procedures. The introduction of flat detectors for c-arm angiographic systems in 2002 provided the possibility of the angiographic suite becoming not just a location for vascular imaging where physiological assessments might also be performed. Over the last decade algorithmic and hardware advances have been sufficient to now realize this potential in clinical practice. The selection of patients for endovascular treatments is enhanced by this dual capability. Along with these advances has been a steady reduction in the radiation exposure required so that today, vascular and soft tissue images may be obtained with equal or in many cases less radiation exposure than is the case for comparable images obtained with multi-detector CT. Learning Objectives: To understand the full capabilities of today’s angiographic suite To understand how c-arm cone beam CT soft tissue imaging can be used for assessments of devices, blood flow and perfusion. Advances in real-time x-ray neuro-endovascular image guidance Stephen Rudin - Reacting to the demands on real-time image guidance for ever finer neurovascular interventions, great improvements in imaging chains are being pursued. For the highest spatial and temporal resolution, x-ray guidance with fluoroscopy and angiography although dominant are still being vastly improved. New detectors such as the Micro-Angiographic Fluoroscope (MAF) and x-ray source designs that enable higher outputs while maintaining small focal spots will be highlighted along with new methods for minimizing the radiation dose to patients. Additionally, new platforms for training and device testing that include patient-specific 3D printed vascular phantoms and new metrics such as generalized relative object detectability for objectively inter-comparing systems will be discussed. This will improve the opportunity for better evaluation of these technological advances which should contribute to the safety and efficacy of image guided minimally invasive neuro-endovascular procedures. Learning Objectives: To understand the operation of new x-ray imaging chain components such as detectors and sources To be informed about the latest testing methods, with 3D printed vascular phantoms, and new evaluation metrics for advanced imaging in x-ray image guided neurovascular interventions Advances in cone beam CT anatomical and functional imaging in angio-suite to enable one-stop-shop stroke imaging workflow Guang-Hong Chen - The introduction of flat-panel detector based cone-beam CT in clinical angiographic imaging systems enabled treating physicians to obtain three-dimensional anatomic roadmaps for bony structure, soft brain tissue, and vasculatures for treatment planning and efficacy checking after the procedures. However, much improvement is needed to reduce image artifacts, reduce radiation dose, and add potential functional imaging capability to provide four-dimensional dynamic information of vasculature and brain perfusion. In this presentation, some of the new techniques developed to address radiation dose issues, image artifact reduction and brain perfusion using C-arm cone-beam CT imaging system will be introduced for the audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens AX.; M. Gounis, consultant for Codman Neurovascular and Stryker Neurovascular; Holds stock in InNeuroCo Inc, research grants: NIH, Medtronic Neurovascular, Microvention/Terumo, Cerevasc LLC, Gentuity, Codman Neurovascular, Philips Healthcare, Stryker Neurovascular, Tay Sachs Foundation, and InNeuroCo Inc.; S. Rudin, Supported in part by NIH Grant R01EB002873 and the Toshiba Medical System Corp.

60 APPLIED LIFE SCIENCES↗

High Sensitivity SPECT for Small Animals and Plants

Imaging systems using single gamma-ray emitting radioisotopes typically implement collimators in order to form the images. However, a tradeoff in sensitivity is inherent in the use of collimators, and modern preclinical single-photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma-rays (<0.3%). We have built a collimator-less system, which can reach sensitivity of 40% for 99 mTc imaging, while still producing images of sufficient spatial resolution for certain applications in thin objects such as mice, small plants, and well plates used for in vitro experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive characterisation of polymers and Al-alloys by polychromatic cone-beam phase contrast tomography

X-ray computed tomography (XCT) has become a very important tool for the non-destructive characterisation of materials. Continuous improvements in the quality and performance of X-ray tubes and detectors have led to cone-beam XCT systems that can now achieve spatial resolutions down to 1 {mu}m and even below. Since not only the amplitude but also the phase of an X-ray beam is altered while passing through an object, phase contrast effects can occur even for polychromatic sources when the spatial coherence due to a small focal spot size is high enough. This can lead to significant improvements over conventional attenuation-based X-ray computed tomography. Phase contrast can increase by edge enhancement the visibility of small structures and of features which are only slightly different in attenuation. We report on the possibilities of polychromatic cone-beam phase contrast tomography for non-destructive characterisation of materials. A carbon fibre-reinforced polymer and the Al-alloys AlMg5Si7 and AlSi18 were investigated with high resolution cone-beam X-ray computed tomography with a polychromatic tube source. Under certain conditions strong phase contrast resulting in an upward and downward overshooting of the grey values across edges was observed. The phase effects are much stronger for the polymer than for the Al-alloys. The influence on the phase contrast of the parameters, including source-detector distance, focal spot size and tube acceleration voltage is presented. Maximum phase contrast was observed for a maximum distance between the source and the detector, for a low voltage and a minimum focal spot size at the X-ray source. The detectability of the different phases is improved by the edge enhancement and the resulting improvement of sharpness. Thus, a better segmentation of the carbon fibres in the fibre-reinforced polymer and of the Mg{sub 2}Si-phase in the AlMg5Si7-alloy is achieved. Primary and eutectic Si cannot be detected by attenuation-based X-ray computed tomography due to the small difference in X-ray attenuation between the Si and the Al-matrix in AlSi18. However, phase contrast effects lead to a significant detectability and the large primary Si particles become clearly visible in the tomograms of AlSi18. - Highlights: Black-Right-Pointing-Pointer Phase contrast increases with increasing distance object-detector and with decreasing U, X-ray spot. Black-Right-Pointing-Pointer The detectability of details is improved by the phase contrast. Black-Right-Pointing-Pointer For the carbon fibre-reinforced polymer the visibility of the carbon fibres is improved. Black-Right-Pointing-Pointer For AlMg5Si7 the detectability of the phases Fe-aluminides and Mg{sub 2}Si particles is improved. Black-Right-Pointing-Pointer For AlSi18 primary Si particles with a size > 50 {mu}m become detectable because of the phase contrast.

36 MATERIALS SCIENCE↗

In situ object counting system (ISOCSi3T{sup M}) technique: A cost-effective tool for NDA verification in IAEA Safeguards

Nuclear material measurements using the ISOCS technique are playing an increasing role in IAEA verification activities. The ISOCS capabilities include: a high sensitivity to the presence of U and Pu; the ability to detect very small amounts of material; and the ability to measure items of different shapes and sizes. In addition, the numerical absolute efficiency calibration of a germanium detector used in the technique does not require any calibration standards or reference materials. The ISOCS modelling software performs an absolute efficiency calibration for items with various container shapes, container wall materials, material compositions, material fill-heights, U/Pu weight fractions and even heterogeneously distributed emitting materials. In a number of cases, some key parameters, such as the matrix density and U/Pu weight fraction, can be determined in addition to the emitting material mass and isotopic composition. These capabilities provide a verification solution suitable for a majority of cases where quantitative and isotopic analysis should be performed. Taking into account these advantages, the technique becomes a cost-effective solution for nuclear material non-destructive assay (NDA) verification. At present, the IAEA uses the ISOCS for a wide range of applications including the quantitative analysis of U scrap materials, U/Pu contaminated solid wastes, U fuel elements, U hold-up materials. Additionally, the ISOCS is also applied to some specific verification cases such as the measurement of PuBe neutron sources and the quantification of fission products in solid wastes. In reprocessing facilities with U/Pu waste compaction or facilities with item re-batching, the continuity-of-knowledge can be assured by applying either video surveillance systems together with seals (requiring attaching/detaching and verification activities for each seal) or verification of operator declarations using quantitative measurements for items selected on a random basis. In some cases, the first option is too expensive and places a high demand on inspector and operator time. Quantitative NDA based on the ISOCS technique verifies these materials and significantly decreases the resources required for assuring the continuity-of-knowledge. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production of Sulfur Allotropes in Electron Irradiated Jupiter Trojans Ice Analogs

In this paper, we investigate sulfur chemistry in laboratory analogs of Jupiter Trojans and Kuiper Belt Objects (KBOs). Electron irradiation experiments of CH{sub 3}OH–NH{sub 3}–H{sub 2}O and H{sub 2}S–CH{sub 3}OH–NH{sub 3}–H{sub 2}O ices were conducted to better understand the chemical differences between primordial planetesimals inside and outside the sublimation line of H{sub 2}S. The main goal of this work is to test the chemical plausibility of the hypothesis correlating the color bimodality in Jupiter Trojans with sulfur chemistry in the incipient solar system. Temperature programmed desorption (TPD) of the irradiated mixtures allows the detection of small sulfur allotropes (S{sub 3} and S{sub 4}) after the irradiation of H{sub 2}S containing ice mixtures. These small, red polymers are metastable and could polymerize further under thermal processing and irradiation, producing larger sulfur polymers (mainly S{sub 8}) that are spectroscopically neutral at wavelengths above 500 nm. This transformation may affect the spectral reflectance of Jupiter Trojans in a different way compared to KBOs, thereby providing a useful framework for possibly differentiating and determining the formation and history of small bodies. Along with allotropes, we report the production of organo-sulfur molecules. Sulfur molecules produced in our experiment have been recently detected by Rosetta in the coma of 67P/Churyumov–Gerasimenko. The very weak absorption of sulfur polymers in the infrared range hampers their identification on Trojans and KBOs, but these allotropes strongly absorb light at UV and Visible wavelengths. This suggests that high signal-to-noise ratio UV–Vis spectra of these objects could provide new constraints on their presence.

79 ASTRONOMY AND ASTROPHYSICS↗

A New Approach to Space Situational Awareness using Small Ground-Based Telescopes

This report discusses a new SSA approach evaluated by Pacific Northwest National Laboratory (PNNL) that may lead to highly scalable, small telescope observing stations designed to help manage the growing space surveillance burden. Using the methods and observing tools described in this report, the team was able to acquire and track very faint satellites (near Pluto’s apparent brightness). Photometric data was collected and used to correlate object orbital position as a function of atomic clock-derived time. Object apparent brightness was estimated by image analysis and nearby star calibration. The measurement performance was only limited by weather conditions, object brightness, and the sky glow at the observation site. In the future, these new SSA technologies and techniques may be utilized to protect satellite assets, detect and monitor orbiting debris fields, and support Outer Space Treaty monitoring and transparency.

47 OTHER INSTRUMENTATION↗

Deep Analysis Net with Causal Embedding for Coal-fired Power Plant Fault Detection and Diagnosis (DANCE4CFDD)

Fault detection and diagnosis is critical to power plant operation to ensure attaining high reliability while reducing operation cost. As more renewable power is introduced to the power grid, traditional fossil power plants take on the extra burden of excessive load cycling to compensate the generation variability from renewable power. Such load cycling will pose more reliability challenges to power plant operation. There are a number of challenges faced by today’s asset health management system in coal- fired (or gas) power plants: 1) high-dimensional nonlinear interaction among multiple time series measurements; 2) high measurement variance induced by operational conditions/modes; 3) variation among asset types and plant configurations; and 4) a small number of faulty events to learn from. To cope with these challenges, today’s fielded asset health management systems rely heavily on manual efforts from domain experts and hand-crafted features or rules based on domain knowledge. Despite its role in plant reliability, such a practice is costly and hinders its scalability and sustainability, particularly when a plant undergoes modifications. The objective of this project is to develop a novel end-to-end AI learning system that is trainable (i.e., the AI representation of a complex system behavior can be directly learned from properly labeled data) for accurate fault detection and root cause analysis. The ability to create a fault detection model directly from time series could alleviate the efforts associated with today’s asset management solution development. In the course of this project, we have achieved the following: Created an AI model development environment incorporating state-of-the-art neural network architectures for rapid model development and evaluation; Developed novel learning strategies for training of fault detection model; Developed special-purpose neural network architecture embedded with variable association graph aiming for better interpretability; Developed a learning strategy to leverage a small number of faulty events for enhanced fault detection capability; Conducted detailed experimental study based on public benchmark datasets and demonstrated the effectiveness of the proposed solution; and Validated the developed system with data from both a coal-fired plant boiler dynamic simulation model and real-world coal-fired power plant covering multiple asset and fault types. Overall, the project attained a technology readiness level of TRL 5 from TRL 2 at the beginning of the project.

20 FOSSIL-FUELED POWER PLANTS↗

Low-Frequency Shear and Layer-Breathing Modes in Raman Scattering of Two-Dimensional Materials

Ever since the isolation of single-layer graphene in 2004, two-dimensional layered structures have been among the most extensively studied classes of materials. To date, the pool of two-dimensional materials (2DMs) continues to grow at an accelerated pace and already covers an extensive range of fascinating and technologically relevant properties. An array of experimental techniques have been developed and used to fully characterize and understand these properties. In particular, Raman spectroscopy has proven to be a key experimental technique, thanks to its capability to identify minute structural and electronic effects in nondestructive measurements. While high-frequency (HF) intralayer Raman modes have been extensively employed for 2DMs, recent experimental and theoretical progress has demonstrated that low-frequency (LF) interlayer Raman modes are more effective at determining layer numbers and stacking configurations, and provide a unique opportunity to study interlayer coupling. These advantages are due to 2DMs’ unique interlayer vibration patterns where each layer behaves as an almost rigidly moving object with restoring forces corresponding to weak interlayer interactions. Compared to HF Raman modes, the relatively small attention originally devoted to LF Raman modes is largely due to their weaker signal and their proximity to the strong Rayleigh line background, which previously made their detection challenging. Recent progress in Raman spectroscopy with technical and hardware upgrades now makes it possible to probe LF modes with a standard single-stage Raman system and has proven crucial to characterize and understand properties of 2DMs. Here, we present a comprehensive and forward-looking review on the current status of exploiting LF Raman modes of 2DMs from both experimental and theoretical perspectives, revealing the fundamental physics and technological significance of LF Raman modes in advancing the field of 2DMs. We review a broad array of materials, with varying thickness and stacking configurations, discuss the effect of in-plane anisotropy, and present a generalized linear chain model and interlayer bond polarizability model to rationalize the experimental findings. We also discuss the instrumental improvements of Raman spectroscopy to enhance and separate LF Raman signals from the Rayleigh line. Lastly, we highlight the opportunities and challenges ahead in this fast-developing field.

36 MATERIALS SCIENCE↗

A search for optical variability of type 2 quasars in SDSS stripe 82

Hundreds of Type 2 quasars have been identified in Sloan Digital Sky Survey (SDSS) data, and there is substantial evidence that they are generally galaxies with highly obscured central engines, in accord with unified models for active galactic nuclei (AGNs). A straightforward expectation of unified models is that highly obscured Type 2 AGNs should show little or no optical variability on timescales of days to years. As a test of this prediction, we have carried out a search for variability in Type 2 quasars in SDSS Stripe 82 using difference-imaging photometry. Starting with the Type 2 AGN catalogs of Zakamska et al. and Reyes et al., we find evidence of significant g-band variability in 17 out of 173 objects for which light curves could be measured from the Stripe 82 data. To determine the nature of this variability, we obtained new Keck spectropolarimetry observations for seven of these variable AGNs. The Keck data show that these objects have low continuum polarizations (p ≲ 1% in most cases) and all seven have broad Hα and/or Mg II emission lines in their total (unpolarized) spectra, indicating that they should actually be classified as Type 1 AGNs. We conclude that the primary reason variability is found in the SDSS-selected Type 2 AGN samples is that these samples contain a small fraction of Type 1 AGNs as contaminants, and it is not necessary to invoke more exotic possible explanations such as a population of 'naked' or unobscured Type 2 quasars. Aside from misclassified Type 1 objects, the Type 2 quasars do not generally show detectable optical variability over the duration of the Stripe 82 survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Chandra and MMT observations of low-mass black hole active galactic nuclei accreting at low rates in dwarf galaxies

We report on Chandra X-ray observations of four candidate low-mass black hole (M {sub bh} ≲ 10{sup 6} M {sub ☉}) active galactic nuclei (AGNs) that have the estimated Eddington ratios among the lowest (∼10{sup –2}) found for this class. The aims are to validate the nature of their AGNs and to confirm the low Eddington ratios that are derived from the broad Hα line, and to explore this poorly studied regime in the AGN parameter space. Among them, two objects with the lowest significance of the broad lines are also observed with the Multi-Mirror Telescope, and the high-quality optical spectra taken confirm them as Seyfert 1 AGNs and as having small black hole masses. X-ray emission is detected from the nuclei of two of the galaxies, which is variable on timescales of ∼10{sup 3} s, whereas no significant (or only marginal at best) detection is found for the remaining two. The X-ray luminosities are on the order of 10{sup 41} erg s{sup –1} or even lower, on the order of 10{sup 40} erg s{sup –1} for non-detections, which are among the lowest regimes ever probed for Seyfert galaxies. The low X-ray luminosities, compared to their black hole masses derived from Hα, confirm their low accretion rates assuming typical bolometric corrections. Our results hint at the existence of a possibly large population of under-luminous low-mass black holes in the local universe. An off-nucleus ultra-luminous X-ray source in one of the dwarf galaxies is detected serendipitously, with a luminosity (6-9)× 10{sup 39} erg s{sup –1} in 2-10 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

Using angular dispersion and anomalous transmission to shape ultramonochromatic x rays

Optical spectrometers, instruments that work with highly monochromatic light, are commonly rated by the spectral bandwidth, which defines the ability to resolve closely spaced spectral components. Another equally important feature is the spectral contrast, the ability to detect faint objects among these components. Here we demonstrate that a combined effect of angular dispersion (AD) and anomalous transmission (AT) of x rays in Bragg reflection from asymmetrically cut crystals can shape spectral distributions of x rays to profiles with high contrast and small bandwidths. The AD and AT x-ray optics is implemented as a five-reflection, three-crystal arrangement featuring a combination of the above-mentioned attributes so desirable for x-ray monochromators and analyzers: a spectral contrast of {approx_equal} 500, a bandwidth of {approx_equal} 0.46 meV, and a remarkably large angular acceptance of {approx_equal} 107 {mu}rad with 9.1 keV x rays. The new optics can become a foundation for the next-generation inelastic x-ray scattering spectrometers for studies of atomic dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Miniaturized Long-Life, Low-Frequency Acoustic Transmitter for Fish Tracking in Marine Environment - CRADA 447

Advance state-of-art technologies for tracking marine mammals, fish, sea turtles, and other protected species, based on acoustic telemetry. Objectives include: (1) develop a new acoustic transmitter that has a greatly improved detection range and service life while being significantly smaller and lighter than the existing commercial counterparts; and (2) reach a TRL of 5 so the technology is ready for organizations interested in small- or medium-scale field trials.

42 ENGINEERING↗