Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sink Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Simple Program to Estimate the Fast Modular Reactor Steady-State Closed Brayton Cycle Operating Parameters

The Fast Modular Reactor (FMR) is a gas-cooled fast reactor (GFR) that produces a net electricity output of 50 MW with helium-driven closed Brayton cycle. The power plant includes reactor system and power conversion unit (PCU). The reactor system produces fission energy that is transferred by helium flow. The PCU consists of a turbine, two compressors, and three heat exchanges. More specifically, the recuperator is a counter-flow energy recovery heat exchanger. The precooler and intercooler are the heat sinks. To analyze and understand the sensitivity of plant performance to the design parameters, a numerical program was written to calculate the plant operating parameters represented by the helium temperature, pressure, mass flow, and the heat sink temperatures. The program was developed for the steady-state operating condition. etc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat pipe cooling system with sensible heat sink

A heat pipe cooling system which employs a sensible heat sink is discussed. With this type of system, incident aerodynamic heat is transported via a heat pipe from the stagnation region to the heat sink and absorbed by raising the temperature of the heat sink material. The use of a sensible heat sink can be advantageous for situations where the total mission heat load is limited, as it is during re-entry, and a suitable radiation sink is not available.

Silverstein, Calvin C.↗

Characterization of Flat-Plate Heat Pipe Functionality for Fuel Cell Application

For many exothermic systems such as proton exchange membrane (PEM) fuel cells, cooling is necessary to maintain consistent and uniform operating temperatures which are generally in the range of 60 to 80°C. A potential solution is a heat pipe employing the principle of conduction in combination with a phase change. The purpose of this study was to fully characterize the operation of a heat pipe with unique geometry designed for fuel cell heat removal at operating temperatures up to 100°C and to assess the suitability of the resulting performance for cooling system integration. Test variables consist of cold sink thermal contact conductance coefficient improving material usage, heat rejection temperature, contact pressure and area, heat pipe orientation, operational hours, and variability between units. The test results showed that heat pipe performance improves through increased condenser and heat sink contact pressure, thermal contact coating usage, greater condenser area utilization, and colder heat sink temperature. Higher initial heat pipe temperature and greater age or operation time reduce the heat pipe capabilities. Placing the condenser lower than the evaporator is the only heat pipe orientation that affects evaporator plate temperature. Condensing fluid in the lower section reduces heat transfer capacity as that orientation requires liquid water to transport by wicking against gravity.

Smith, Phillip J.↗

Thermal Strap Increases Cryocooling Efficiency

Report discusses concept for decreasing compressor power consumed by spacecraft mechanical cryocooler providing 0.5 W of refrigeration at temperature of 61 K at tip of cold finger. Involves connecting thermal strap between radiator or other heat sink at intermediate temperature and stiffening ring located on cold finger about one-third way from base to tip and attains temperature of about 250 K during normal operation. Depending upon specific design, electrical power consumed by mechanical cryocooler reduced by half.

Ross, Ronald G., Jr.↗

Device and method for measuring thermal conductivity of thin films

A device and method are provided for measuring the thermal conductivity of rigid or flexible, homogeneous or heterogeneous, thin films between 50 .mu.m and 150 .mu.m thick with relative standard deviations of less than five percent. The specimen is sandwiched between like material, highly conductive upper and lower slabs. Each slab is instrumented with six thermocouples embedded within the slab and flush with their corresponding surfaces. A heat source heats the lower slab and a heat sink cools the upper slab. The heat sink also provides sufficient contact pressure onto the specimen. Testing is performed within a vacuum environment (bell-jar) between 10.sup.-3 to 10.sup.-6 Torr. An anti-radiant shield on the interior surface of the bell-jar is used to avoid radiation heat losses. Insulation is placed adjacent to the heat source and adjacent to the heat sink to prevent conduction losses. A temperature controlled water circulator circulates water from a constant temperature bath through the heat sink. Fourier's one-dimensional law of heat conduction is the governing equation. Data, including temperatures, are measured with a multi-channel data acquisition system. On-line computer processing is used for thermal conductivity calculations.

Amer, Tahani R.↗

A study of high-temperature heat pipes with multiple heat sources and sinks. I - Experimental methodology and frozen startup profiles. II - Analysis of continuum transient and steady-state experimental data with numerical predictions

Experimental profiles for heat pipe startup from the frozen state were obtained, using a high-temperature sodium/stainless steel pipe with multiple heat sources and sinks to investigate the startup behavior of the heat pipe for various heat loads and input locations, with both low and high heat rejection rates at the condensor. The experimental results of the performance characteristics for the continuum transient and steady-state operation of the heat pipe were analyzed, and the performance limits for operation with varying heat fluxes and location are determined.

Faghri, A.↗

The use of a thermal utility with space-platform-mounted instruments

A thermal utility is a high-capacity heat transport system that serves as a common, temperature-controlled heat sink or source to more than one payload. The feasibility of using a thermal utility for space-platform-mounted instruments which have a range of temperature level and heat rejection requirements is examined and significant design parameters are identified. A baseline, pumped, two-phase heat transport system has been defined for NASA's proposed Space Platform, and its capability to satisfy the thermal requirements of a range of multidisciplinary instruments has been assessed.

Almgren, D. W.↗

The Monolithic Heat Pipe Microreactor Reference Plant Model

This work introduces a reference plant model for a generic monolithic heat-pipe-cooled microreactor. The model will serve as a springboard to develop future evaluation models in the licensing process of similar microreactor designs at the U.S. Nuclear Regulatory Commission. This model has been developed with the Comprehensive Reactor Analysis Bundle and its specifications are based on open literature publications for the eVinci TM design. BlueCRAB is the U.S. Nu- clear Regulatory Commission non-light-water reactor analysis system based on the Multiphysics Object-Oriented Simulation Environment framework, which can couple the Griffin, BISON, and Sockeye applications to resolve the various physics that are essential for the safety analysis of this type of reactor system. The core specifications includes tristructural isotropic fuel, graphite monolith, graphite reflectors, and drums composed of graphite and B 4 C. No moderator or burnable poison pins are used in the design. The fuel enrichment is reduced to control excess reactivity in the core. This core design is not optimized and only serves for testing purposes, since the primary objective of this work is to exercise the multiphysics coupling for this type of reactor system. A three dimensional (3D) core heterogeneous Griffin discrete ordinates (SN) transport model allows the precise calculation of the flux distribution and pin powers. Griffin transfers the power density distribution and obtains a temperature distribution to and from BISON. The BISON model com- putes the 3D core temperature distribution and is coupled to 876 Sockeye subapplications running a heat pipe model. This 3D conduction model is coupled to the various heat pipes via heat flux boundary conditions. The model includes a small gap between the heat pipe and the monolith. Convective heat transfer boundaries with either ambient temperature or condenser temperature as heat sinks are imposed at the model boundaries. The 2D Sockeye heat pipe model uses a vapor- only methodology, which provides the needed resolution for transient calculations and allows the determination of various heat pipe limits. This approach is superior to the superconductor model traditionally used in steady-state calculations. BlueCRAB computes steady-state power and temperature distributions that serve as the initial condition for a loss-of-heat-sink transient simulation. The steady-state results show significant peaking due to the position of the control drum, but this is a characteristic of the particular design used, which is not optimized at this stage. The transient results show the reactor power slowly stabilizing towards a 3% power level after the partial loss of secondary heat removal. Several recriticalities are observed due to cooling through the secondary system but the reactor is self-stabilizing and behaves as expected.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cooling of a sunspot

The question of whether a perturbed photospheric area can grow into a region of reduced temperature resembling a sunspot is investigated by considering whether instabilities exist that can lead to a growing temperature change and corresponding magnetic-field concentration in some region of the photosphere. After showing that Alfven cooling can lead to these instabilities, the effect of a heat sink on the temperature development of a perturbed portion of the photosphere is studied. A simple form of Alfven-wave cooling is postulated, and computations are performed to determine whether growing modes exist for physically relevant boundary conditions. The results indicate that simple inhibition of convection does not give growing modes, but Alfven-wave production can result in cooling that leads to growing field concentration. It is concluded that since growing instabilities can occur with strong enough cooling, it is quite possible that energy loss through Alfven waves gives rise to a self-generating temperature change and sunspot formation.

Boruta, N.↗

Moving-Gradient Furnace With Constant-Temperature Cold Zone

Outer heat pipe helps in controlling temperature of cold zone of furnace. Part of heat-pipe furnace that includes cold zone surrounded by another heat pipe equipped with heater at one end and water cooling coil at other end. Temperature of heat pipe maintained at desired constant value by controlling water cooling. Serves as constant-temperature heat source or heat sink, as needed, for gradient of temperature as gradient region moved along furnace. Proposed moving-gradient heat-pipe furnace used in terrestrial or spaceborne experiments on directional solidification in growth of crystals.

Gernert, Nelson J.↗

A Continuous Adiabatic Demagnetization Refrigerator for Use with Mechanical Coolers

We have begun developing an adiabatic demagnetization refrigerator (ADR) which can produce continuous cooling at temperatures of 50 mK or lower, with high cooling power (goal of 10 PW). The design uses multiple stages to cascade heat from a continuously-cooled stage up to a heat sink. The serial arrangement makes it possible to add stages to extend the operating range to lower temperature, or to raise the heat rejection temperature. Compared to conventional single-shot ADRS, this system achieves higher cooling power per unit mass and is able to reject its heat at a more uniform rate. For operation with a mechanical cryocooler, this latter feature stabilizes the heat sink temperature and allows both the ADR and cryocooler to operate more efficiently. The ADR is being designed to operate with a heat sink as warm as 10-12 K to make it compatible with a wide variety of mechanical coolers as part of a versatile, cryogen-free low temperature cooling system. A two-stage system has been constructed and a proof-of-principle demonstration was conducted at 100 mK. Details of the design and test results, as well as the direction of future work, are discussed.

Shirron, P.↗

Methane-cycling microbial communities from Amazon floodplains and upland forests respond differently to simulated climate change scenarios

Seasonal floodplains in the Amazon basin are important sources of methane (CH 4 ), while upland forests are known for their sink capacity. Climate change effects, including shifts in rainfall patterns and rising temperatures, may alter the functionality of soil microbial communities, leading to uncertain changes in CH 4 cycling dynamics. To investigate the microbial feedback under climate change scenarios, we performed a microcosm experiment using soils from two floodplains (i.e., Amazonas and Tapajós rivers) and one upland forest. We employed a two-factorial experimental design comprising flooding (with non-flooded control) and temperature (at 27 °C and 30 °C, representing a 3 °C increase) as variables. We assessed prokaryotic community dynamics over 30 days using 16S rRNA gene sequencing and qPCR. These data were integrated with chemical properties, CH 4 fluxes, and isotopic values and signatures. In the floodplains, temperature changes did not significantly affect the overall microbial composition and CH 4 fluxes. CH 4 emissions and uptake in response to flooding and non-flooding conditions, respectively, were observed in the floodplain soils. By contrast, in the upland forest, the higher temperature caused a sink-to-source shift under flooding conditions and reduced CH 4 sink capability under dry conditions. The upland soil microbial communities also changed in response to increased temperature, with a higher percentage of specialist microbes observed. Floodplains showed higher total and relative abundances of methanogenic and methanotrophic microbes compared to forest soils. Isotopic data from some flooded samples from the Amazonas river floodplain indicated CH 4 oxidation metabolism. This floodplain also showed a high relative abundance of aerobic and anaerobic CH 4 oxidizing Bacteria and Archaea. Taken together, our data indicate that CH 4 cycle dynamics and microbial communities in Amazonian floodplain and upland forest soils may respond differently to climate change effects. We also highlight the potential role of CH 4 oxidation pathways in mitigating CH 4 emissions in Amazonian floodplains.

16S rRNA sequencing↗

Vapor-modulated heat pipe report. Flight data analysis and further development of variable-conductance heat pipes

The design and testing of a heat pipe for spacecraft application is presented. The application in mind calls for heat loads up to 20 watts, a set-point temperature of 294K, and a sink that varies from -220K to nearly as high as the set-point. The overall heat pipe length is 137 cm. Two basically different mechanisms of achieving variable conductance in the pipe by vapor-flow throttling were studied. In one, the thermal resistance between the heat source and sink is due to a saturation-temperature drop corresponding to the vapor-pressure drop developed across the valve. In the other, the pressure difference across the valve induces capillary groove and wick dry out in an evaporation region, and thus results in an increased thermal resistance. This mechanism was selected for fabrication and testing. The pipe is a stainless-steel/methanol two-heat-pipe system. Results are presented and discussed. Engineering drawings and specifications of the pipe are shown.

Eninger, J. E.↗

The reservoir network: A new network topology for district heating and cooling

Thermal district networks are effective solutions to substitute fossil fuels with renewable energy sources for heating and cooling. Moreover, thermal networking of buildings allows energy efficiency to be further increased. The waste heat from cooling can be reused for heating in thermal district systems. Because of bidirectional energy flows between prosumers, thermal networks require new hydraulic concepts. In this work, we present a novel network topology for simultaneous heating and cooling: the reservoir network. The reservoir network is robust in operation due to hydraulic decoupling of transfer stations, integrates heat sources and heat sinks at various temperature levels and is flexible in terms of network expansion. Furthermore, we used Modelica simulations to compare the new single-pipe reservoir network to a basecase double-pipe network, taking yearly demand profiles of different building types for heating and cooling. The electric energy consumed by the heat pumps and circulations pumps differs between the reservoir and base case networks by less than 1%. However, if the reservoir network is operated with constant instead of variable mass flow rate, the total electrical consumption can increase by 48% compared to the base case. As with any other network topology, the design and control of such networks is crucial to achieving energy efficient operation. Investment costs for piping and trenching depend on the district layout and dimensioning of the network. If a ring layout is applied in a district, the reservoir network with its single-pipe configuration is more economical than other topologies. For a linear layout, the piping costs are slightly higher for the reservoir network than for the base case because of larger pipe diameters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemically driven phase transformation for high-efficiency heat pumping

To reduce energy consumption and improve energy utilization in space conditioning, advanced heat pumping technologies are needed. The chemical looping heat pump (CLHP) is a promising thermodynamic cycle that has theoretically shown the potential to achieve a cooling coefficient of performance (COP c ) increase of over 20% relative to conventional vapor compression systems. In this paper, the key process of the CLHP is experimentally demonstrated, and the system performance and non-ideal behavior are predicted using the component-level models. The results show the feasibility of electrochemical phase change of a working fluid; the peak COP c was 7.64 with a cooling capacity of 3.6 mW (cooling density of 2.57 W m -2 ) at both sink and source temperature of 23°C based on laboratory experiments. The COP c can theoretically reach up to 13 at a temperature lift of 15°C as long as an electrochemical cell can achieve a greater degree of conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simple non-destructive tests for electroexplosive devices

Electrothermal behavior of bridgewire-explosive interface is defined by pulsing electroexplosive device with a safe level of current and examining the resistance variation of bridgewire. Bridgewire provides signal which describes average wire temperature and heat sinking to the explosive and enclosure.

Rosenthal, L. A.↗