Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

WHONDRS River Corridor Sediment and Water Geochemistry and In Situ Sensor Data from 7 Perennial and 7 Intermittent Streams across San Antonio, Texas (v3)

This dataset supports a broader study examining the effects of intermittency on sediment respiration. The dataset provides sediment and surface water geochemistry and in situ sensor data from 7 perennial and 7 intermittent streams in San Antonio, Texas. Each stream/site was visited both in summer during base flow (July-September 2023) and winter during peak flow (January-February 2024). Related data were collected and will be published separately in collaboration with A. Veach. The data package was originally published in April 2025. It was updated in June 2025 (v2; modified and new files) and September 2025 (v3; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of two folders of field photos and videos, one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) international generic sample number (IGSN) mapping file; (6) field protocol; (7) a subfolder with sample data; and (8) a subfolder with sensor data. The sample data subfolder contains (1) surface water and sediment dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) surface water and sediment total nitrogen data and averages; (3) sediment grain size data; (4) sediment iron (II) data and averages; (5) wet sediment mass, dry sediment mass, water mass, and wet sediment volume in incubation and sediment ICR vials; (7) sediment incubation respiration rate data and averages; (8) normalized respiration rate data and averages; (9) methods codes; (10) sediment percent carbon and nitrogen; (11) sediment X-ray diffraction (XRD) data; (12) gravimetric moisture and averages; (13) a subfolder with sediment incubation respiration data, scripts, and plots; (14) surface water and sediment FTICR methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains five subfolders, one containing the sediment .xml data files, one containing the water .xml files, one containing the sediment CoreMS output files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). The sensor data subfolder contains (1) a subfolder with miniDOT dissolved oxygen and temperature data and plots; (2) miniDOT dissolved oxygen and temperature summary data; and (3) miniDOT installation methods. All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4. CORRECTION: The data processing methods for FTICR described in “v3_WHONDRS_AV1_Methods_Codes.csv” mistakenly indicate that users should process the data in Formultitude. The corrected description should read: “Both unprocessed and processed data are provided to allow users flexibility in data processing. Instructions and scripts for processing the data using CoreMS are included.” CORRECTION: Carbon and nitrogen content are reported as percentages. The current column headers "01395_C_percent_per_mg" and "01397_N_percent_per_mg" are incorrect. These should read "01395_C_percent" and "01397_N_percent" and will be corrected in the next version of this data package.

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Synoptic Sites Level 1 Sensor Data v2-1

This is the version 2-1 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems. L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds, out-of-service, and outlier flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project** This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v2-0 Synoptic L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. This dataset was updated 2026-03-12: (i) data now go through 2025-12-31 (previous end was 2025-06-30) and (ii) dataset and file names updated to “…v2-1” (previously was “v2-0”).

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 1 Sensor Data v2-1

This is the version 2-1 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments. L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds, out-of-service, and outlier flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project** This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding variable-specific CSV (comma separated value) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v2-1 TEMPEST L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods. * Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021 * TEMPEST 1: June 22, 2022 * TEMPEST 2: June 6-7, 2023 * TEMPEST 3: June 11-13, 2024 This dataset was updated 2026-03-12: (i) data now go through 2025-12-31 (previous end was 2025-06-30) and (ii) dataset and file names updated to “…v2-1” (previously was “v2-0”).

54 ENVIRONMENTAL SCIENCES↗

Test Beam Results of Planar Pixel Sensor for the CMS Phase 2 Inner Tracker Upgrade

Results of the test beam measurements that characterise the performance of CMS Readout Chip (CROC) sensors to be used in the High Luminosity era of the Large Hadron Collider (HL-LHC) are presented. The HL-LHC peak instantaneous luminosity of $7.5 \times 10^{34} \ \text{cm}^{-2} s^{-1}$ corresponds to an average of around 200 inelastic proton-proton collisions per beam-crossing every 25 ns. In order to efficiently reconstruct and track particles in this extreme and challenging conditions, the present CMS tracking detector will be completely replaced. The new tracking detector consists of an Inner Tracker closest to the beamline and an Outer Tracker surrounding it. These are populated with modules that comprise of readout chips and silicon sensors. The test beam measurements of these modules are vital to understand the performance of the related technologies. Using a primary 120 GeV proton beam from the Main Injector at Fermilab, data was collected at the Fermilab Test Beam Facility (FTBF) using the silicon tracker telescope that provides a precision position measurement of the track impact point with less than 5 $\mu$m uncertainty. The proton beam was incident on a 1x2 planar CROC module developed by Hamamatsu. The sensor has 100x25 $\mu m^2$ standard pixels and also a smaller number of 225x25 $\mu m^2$ longer pixels at the boundary between the two ROCs. We present characterization of these modules that includes pixel efficiency, resolution, cluster size and charge distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report on Characterization of Irradiated Sensors and Coupling Adhesive Bonds

This report summarizes characterization via scanning/transmission electron microscopy of the microstructures of the unirradiated and irradiated piezoelectric ultrasonic sensor/aluminum substrate assemblies using four commercially available inorganic coupling adhesives to bond two types of piezoelectric crystals to the substrates. The sample assemblies were irradiated in the PULSTAR reactor at NC State University and ultrasonic data was collected in-situ. ORNL LAMDA Laboratory capabilities were utilized to perform pre- and post-irradiation examination of the sensor assemblies. This document summarizes the PIE performed at the ORNL LAMDA laboratory. The results of the PIE described in this report are consistent with the ultrasonic data collected during irradiation – in particular, high temperature epoxy adhesive seemed to provide the best coupling as compared to the refractory ceramic adhesives. It was determined that the quality of the sensor-adhesive-substrates governed the ultrasonic performance of the sensors. It was also apparent that irradiation did not significantly affect bond quality, which is also supported by the ultrasonic data collected during irradiation. A more comprehensive DOE NSUF Final Report including details of materials selection, sample fabrication, initial ultrasonic testing, irradiation and in-situ ultrasonic testing, positron annihilation lifetime spectroscopy and doppler broadening spectroscopy performed at EPRI and NC State University will be published at the conclusion of the project.

36 MATERIALS SCIENCE↗

Flow Sensor Test Article (F-STAr) - Water Testing and Commissioning Report for FY2024

Argonne National Laboratory’s Mechanism Engineering Test Loop (METL) facility is developing new experimental testing capabilities with the Flow Sensor Test Article (F-STAr). F-STAr’s mission is to provide high flowrate, sodium submersible testing capabilities to support the development of sodium cooled nuclear fission reactors. Figure 1 shows a model of F-STAr (left) and a photo of the partially assembled test article (right) with several of the main components labeled. The system currently includes a large pump with desired flowrates of up to 100 GPM; an immersion heater with a maximum power of 5 kW; an immersion cooler with an estimated maximum cooling power of 2 kW; and an experimental test section to support sub-test articles. Initially, F-STAr will be setup for testing flow sensors, specifically Eddy Current Flow Sensors (ECFS). However, the system can be reconfigured to support a wide range of testing needs. For example, F-STAr could be setup to complete testing of hydraulic components, heat exchangers, hydrodynamic bearings, seals, and more. This report will provide an update on the development of F-STAr with a focus on the water testing and commissioning activities during Fiscal Year 2024 (FY24). First, the report will focus on describing the pump development. Specifically, updates will be provided on troubleshooting the pump’s excessive vibrational issues. In addition to updates on the pump, pressure-flowrate performance testing in water will be described. Furthermore, updates will be provided on a pump shaft bushing development as well as rigging procedures. Future work and paths forward for F-STAr will be described. Finally, a short summary on the ECFS development will be described at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Zero-Power Wireless Infrared Digitizing Sensors for Large Scale Energy-Smart Farm

This project, funded by ARPA-E and led by Northeastern University, developed zeropower infrared digitizing sensors to optimize irrigation and enhance crop yields. Traditional water stress detection methods are costly and require frequent maintenance, limiting their effectiveness. Our research identified shortwave infrared (SWIR) transmittance as the most reliable indicator of plant water stress and developed plasmonically enhanced micromechanical photoswitches (PMPs) that operate with minimal power. The sensors offer low-cost, large-scale deployment, auto-calibration across different crops, and a 10-year battery life, significantly reducing maintenance costs. The system achieved 4x greater accuracy than conventional soil moisture sensors while ensuring economic feasibility. By enabling precision irrigation, this technology conserves water, enhances crop productivity, and lowers operational costs, making it a scalable solution for sustainable agriculture and global food security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Development and Analysis of a High-Fidelity Neutron Transport Sensor: The Quadrupole Detector Concept for Measurement of the Neutron Flux Gradient

Accurate reconstruction of the neutron flux distribution within a reactor core is essential for safe and efficient reactor operation. Traditional power shape synthesis in Light Water Reactors relies on hundreds of in-core detectors. However, this approach becomes impractical for Advanced Reactors and Microreactors due to limited space and harsh environments. To address this challenge, we propose a data-driven methodology that combines high-fidelity modeling with real-time ex-core sensor measurements, enabling the reconstruction of core power distribution while minimizing the reliance on intrusive in-core instrumentation. This project began in FY24 and achieved two initial milestones: (1) the definition of a three-year development plan for a Digital Twin framework and (2) the development of high-fidelity neutronics models of the Purdue University Reactor One (PUR-1) using both MCNP6 and OpenMC. The PUR-1 reactor, a zero-power facility, was selected due to its suitability for neutronics-focused modeling and the availability of experimental data for validation. Both models were benchmarked using neutron flux measurements obtained from irradiated gold foils, which were strategically placed within the core during a dedicated campaign in July 2024. This report marks the continuation and completion of those foundational tasks. The OpenMC model has been refined (improved geometric accuracy, expanded cross-section libraries, and refined sampling) and validated using additional experimental data. An updated sensor design—based on quadrupole configuration—was designed to measure both ex-core flux and its spatial gradient. These measurements will serve as inputs to a neural network-based reconstruction algorithm. Finally, the methodology was demonstrated on a two-dimensional test case representative of the heterogeneous material composition of the PUR-1 reactor core. A neural network implementation of the Kirchhoff-Helmholtz integral equation was employed to solve the boundary value problem using peripheral sensor measurements. The preliminary results confirm the strong potential of the proposed approach for accurate and minimally invasive neutron flux reconstruction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Real-Time Xenon Sensor Analysis Report

Radiotracer release experiments were performed at the Nevada National Security Site in October 2022. The overall experiment was called the RElease ACTivity (REACT) experiment. Twenty-two real-time xenon sensors were deployed for each of four releases. Initial, quick-look analysis results were reported in December 2022. This report reviews the more comprehensive offline analysis effort that was conducted during the remainder of fiscal year 2023 by the Dynamic Networks venture. Improved energy stabilization routines were implemented along with an improved background subtraction routine compared to the original quicklook calculations. The relative detection efficiencies of all real-time sensors were examined. Finally, simulated detector response functions were coupled to two different meteorological models using the measured conditions for the final release (REACT-04) to compare simulated detections with measurements. While there is some agreement between the models and measured data on the detection locations and timing, there is less agreement on the magnitude of those detections. Future sensor and meteorological modeling work will be needed to improve the agreement and to examine the additional releases (REACT-01 through REACT-03).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Accuracy and High-Stability Fiber-Optic Temperature Sensors for Coal Fired Advanced Energy

A research team at Michigan State University, led by Dr. Ming Han, has developed a revolutionary fiber-optic thermometer for use in next-generation coal-fired power plants. Funded by the U.S. Department of Energy, this new sensor is designed to measure extremely high temperatures with unmatched accuracy and long-term stability. Unlike conventional optical sensors that can give false readings due to mechanical strain and often drift out of calibration at high heat, this new technology uses a sealed gas chamber as its core. By measuring the temperature-dependent properties of the gas (air or argon), the sensor’s readings remain absolute and reliable, completely unaffected by the physical stresses on the surrounding equipment. The breakthrough design eliminates the need for complex and costly correction systems. It represents a fundamental shift in sensing technology, paving the way for a primary thermometer that maintains calibration and provides foundational accuracy essential for advanced energy systems.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of Three Types of Electric Field Sensors

On June 3-4, 2025, we evaluated three types of electric-field (E-field) sensors: capacitive electrodes, stainless-steel stakes, and porous pots - at two electromagnetic (EM) stations (PWBVI and PWAOF) on Aqueduct Mesa at the Nevada National Security Site. We compared calibrated time series and derived metrics including power spectral density, root-mean-square (RMS) amplitude, signal-to-noise ratio (SNR), and detectability of power line harmonics and Schumann resonance. The objective was to identify an alternative E field sensor with higher SNR than the existing capacitive electrodes. Our data demonstrates that stainless-steel electrodes perform best, with the highest SNR and the most consistent detection of power-line harmonics and Schumann resonance among the three sensor types; they may be used as a supplement to, or replacement for, the existing capacitive electrodes.

58 GEOSCIENCES↗

Trident Smyth: Near Real Time Sensor Fusion and Track Stitching Application

Sandia’s Sensor Data Fusion application is a NGA sponsored project that fuses tracks from different sensors to provide more accuracy than any single track. The application serves as the unclassified architecture for data ingestion, processing, and near real-time sensor fusion.

Sorroche, Joseph John [Sandia National Laboratorie↗

Glancing Angle Deposition in Gas Sensing: Bridging Morphological Innovations and Sensor Performances

Glancing Angle Deposition (GLAD) has emerged as a versatile and powerful nanofabrication technique for developing next-generation gas sensors by enabling precise control over nanostructure geometry, porosity, and material composition. Through dynamic substrate tilting and rotation, GLAD facilitates the fabrication of highly porous, anisotropic nanostructures, such as aligned, tilted, zigzag, helical, and multilayered nanorods, with tunable surface area and diffusion pathways optimized for gas detection. This review provides a comprehensive synthesis of recent advances in GLAD-based gas sensor design, focusing on how structural engineering and material integration converge to enhance sensor performance. Key materials strategies include the construction of heterojunctions and core–shell architectures, controlled doping, and nanoparticle decoration using noble metals or metal oxides to amplify charge transfer, catalytic activity, and redox responsiveness. GLAD-fabricated nanostructures have been effectively deployed across multiple gas sensing modalities, including resistive, capacitive, piezoelectric, and optical platforms, where their high aspect ratios, tailored porosity, and defect-rich surfaces facilitate enhanced gas adsorption kinetics and efficient signal transduction. These devices exhibit high sensitivity and selectivity toward a range of analytes, including NO2, CO, H2S, and volatile organic compounds (VOCs), with detection limits often reaching the parts-per-billion level. Emerging innovations, such as photo-assisted sensing and integration with artificial intelligence for data analysis and pattern recognition, further extend the capabilities of GLAD-based systems for multifunctional, real-time, and adaptive sensing. Finally, current challenges and future research directions are discussed, emphasizing the promise of GLAD as a scalable platform for next-generation gas sensing technologies.

Chemistry↗

Improving Chirped Fiber Bragg Grating Resolution for Position-Sensitive Sensors in Shock- and Detonation-Driven Experiments

Chirped fiber Bragg gratings (CFBGs) are robust diagnostic sensors that are widely used to track detonation-driven and shock wave propagation. CFBGs are inscribed with a linearly chirped periodic index of refraction changes that alter the Bragg wavelength along the length of the probe. The light return of each individual Bragg element is captured by a detector at a unique time to map the full reflected spectrum. The CFBG spectrum is measured with a dispersive Fourier transform of the reflected light that temporally stretches the spectrum to increase spatial resolution and make a one-to-one map of the wavelength on a time axis. Here, we propose an improvement of CFBG temporal resolution by incorporating two co-linear laser pulses with orthogonal polarization states and a 5 ns time offset. The two separate signals were split and tracked by two separate detectors. An oscilloscope captured good separation in the signals, and two separate spectrograms were generated and interleaved in the post-processing of the data. This novel technique doubled the CFBG temporal resolution and led to a doubled location resolution. As a proof-of-concept of this technique, the resolution improvement was compared between standard CFBG measurements and the two polarization states method on a position-sensitive CFBG sensor. CFBG resolution doubling will advance sensor capabilities and will have a direct impact on improving capture and analysis in dynamic, high-explosive experiments.

42 ENGINEERING↗

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods, are disclosed. A representative method for forming a nuclear-powered steam generator includes forming an instrumented support, the instrumented support including a carrier portion and a retainer portion, with at least one of the carrier portion or the retainer portion being integrally formed with a sensor via an additive manufacturing process. The method can further include coupling the sensor to a communication link, supporting a helical steam conduit on the instrumented support, and installing the helical steam conduit and the instrumented support in a nuclear reactor. The helical steam conduit is positioned along a primary flow path, which is in turn positioned to circulate a heated primary flow in thermal communication with the helical steam conduit.

Welter, Kent↗

Sensor array and apparatus for simultaneous observation of tissue electrophysiology, contractility, and growth

A method includes simultaneously measuring electrophysiological responses and contractility responses of a plurality of cells forming a tissue culture using a system comprising a sensor array configured to simultaneously measure the electrophysiological responses and the contractility responses of the plurality of cells forming the tissue culture. Fabrication techniques for making such systems include: forming a sensor array comprising an interpenetrating arrangement of IDEs and electrodes of a MEA in or on a substrate surface; forming a plurality of contacts for interfacing the system with one or more external devices in or on the substrate surface; and forming leads between the plurality of contacts and the sensor array.

Qian, Fang↗

Truncated nonlinear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input port that receives an optical beam and a non-linear amplifier that amplifies the optical beam with a pump beam and renders a probe beam and a conjugate beam. The system's local oscillators have a relationship with the respective beams. The system includes a sensor that transduces an input with the probe beam and the conjugate beam or their respective local oscillators. It includes one or more phase-sensitive detectors that detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. Output from the phase-sensitive-detectors is based on the detected phase modulation. The phase-sensor-detectors include measurement circuitry that measure the phase signals. The measurement is the sum or difference of the phase signals in which the measured combination exhibit a quantum noise reduction in an intensity difference or a phase sum or an amplitude difference quadrature.

Pooser, Raphael C.↗