Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Semiconductor Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Using 3D position sensitivity to reveal response non-uniformities in CdZnTe, TlBr, and CsPbBr 3 detectors

Position sensitivity enables the correction of response non-uniformities in room-temperature semiconductor detectors caused by crystal defects and other factors. It can also be used to pinpoint the exact location of crystal defects responsible for the response variations. This work describes a technique for revealing and visualizing the detector regions affecting the charge collection efficiency in CdZnTe (CZT), TlBr, and CsPbBr 3 detectors configured as position-sensitive virtual Frisch-grid (VFG) devices. The technique correlates the photopeak events in energy spectra with their spatial distributions inside the detectors using the position information. By selecting the events from narrow energy intervals within a photopeak, we can visualize the detector volumes with particular charge collection efficiencies, which, in turn, correlate with the locations of electrode and crystal defects. Here, we demonstrate this technique in several examples. Columnar structures in the volume plots (position distribution maps) are consistent with signal losses near or at the anode in selected samples of CZT and TlBr. Structures exhibiting a distinct depth dependence are consistent with grain boundaries or other crystal defects.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Demonstrating Safeguards Applications of DRiFT Gas Detector Capabilities [Slides]

DRiFT, a Detector Response Function Toolkit, post-processes MCNP output to model detector response. Three primary components: scintillator (focus of FY 21 TED work), gas detectors (focus of this FY), and semiconductor detectors. Capability to model scintillator detectors has previously been demonstrated.

47 OTHER INSTRUMENTATION↗

Effects of Surface Processing on the Response of CZT Gamma Detectors: Studies with a Collimated Synchrotron X-Ray Beam

Using a microscale X-ray mapping technique incorporating a synchrotron beam, we are able to reveal the fine details of the surface properties in cadmium zinc telluride (CZT) semiconductor detectors. A detector, with various degrees of surface roughness, was irradiated by a high-spatial-resolution X-ray beam. The detector's response was analyzed and displayed as a two-dimensional (2-D) map, and the charge collection was obtained from the peak positions in the spectra versus the beam's location, which reflects the local material properties. We noted the correlation between the 2-D image and the spectral response of the charge collection at different locations on the surface area, which indicates that a rough surface tends to contain trapping centers, thereby enhancing leakage current and distorting the signal. We also discuss our observations on the transition effect at the boundary area of a rough and a smooth surface under identical conditions.

43 PARTICLE ACCELERATORS↗

DynamiX, numerical tool for design of next-generation x-ray telescopes

We present a new code aimed at the simulation of grazing-incidence x-ray telescopes subject to deformations and demonstrate its ability with two test cases: the Simbol-X and the International X-ray Observatory (IXO) missions. The code, based on Monte Carlo ray tracing, computes the full photon trajectories up to the detector plane, accounting for the x-ray interactions and for the telescope motion and deformation. The simulation produces images and spectra for any telescope configuration using Wolter I mirrors and semiconductor detectors. This numerical tool allows us to study the telescope performance in terms of angular resolution, effective area, and detector efficiency, accounting for the telescope behavior. We have implemented an image reconstruction method based on the measurement of the detector drifts by an optical sensor metrology. Using an accurate metrology, this method allows us to recover the loss of angular resolution induced by the telescope instability. In the framework of the Simbol-X mission, this code was used to study the impacts of the parameters on the telescope performance. In this paper we present detailed performance analysis of Simbol-X, taking into account the satellite motions and the image reconstruction. To illustrate the versatility of the code, we present an additional performance analysis with a particular configuration of IXO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conference Comments by the Editors

The Symposium on Radiation Measurements and Applications (SORMA) met for the first time on the West Coast June 2-5, 2008, in Berkeley, CA. With radiation detectors increasing in number, variety, and societal importance, we plan to alternate between SORMA East (in Ann Arbor, MI) and SORMA West so that the forum will be available every two years. The topic areas for SORMA West 2008 were much the same as those of recent Ann Arbor programs, and were meant to encompass the full breadth of ionizing radiation measurement applications and technologies, with both oral and poster presentations. The technical program of SORMA 2008 included 342 scientific presentations, 116 oral presentations plus eight invited keynote lectures in plenary sessions, as well as 218 presentations in poster sessions. The SORMA 2008 meetings were attended by 439 registered participants from 25 different countries. Topics of interest at the meeting ranged from room temperature semiconductor detectors, cryogenic detectors, photodetectors, neutron detectors, novel scintillators, nonproportionality and characterization of scintillators, simulation and analysis of radiation interactions, novel radiation sources, imaging technologies and homeland security and medical applications. This was the first conference of the SORMA series to be technically cosponsored by the Institute of Electrical and Electronic Engineers (IEEE), specifically by the Nuclear and Plasma Sciences Society (NPSS) of IEEE. The co-sponsorship has been important for visibility of SORMA and for attracting a record number of new participants. This special issue of IEEE TRANSACTIONS ON NUCLEAR SCIENCE comprises the refereed proceedings of SORMA 2008, containing 128 papers on the research presentations. The Chairs of the SORMA 2008 conference would like to acknowledge partial financial support from the NNSA, DNDO, and DTRA, and organizational support from Lawrence Berkeley National Laboratory and Lawrence Livermore National Laboratory. We acknowledge our corporate supporters: Caen Nuclear, Eljen Technology, Hilger Crystals and GE Global Research. Finally, we thank the members of the local organizing committee: Diana Attila, Thomas Budinger, Joe Chew, Daniel Chivers, Rob Johnson, Laurie O'Brien, Donna Raziano, Emily Sause, and Brian Wirth for doing all the work that actually made this conference happen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Central Diffraction in ALICE

The ALICE experiment consists of a central barrel in the pseudorapidity range -0.9<{eta}<0.9 and of additional detectors covering about 3 units of pseudorapidity on either side of the central barrel. Such a geometry allows the tagging of single and double gap events. The status of the analysis of such diffractive events in proton-proton collisions at {radical}(s) = 7 TeV is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the COBRA experiment

The current status of the COBRA experiment is described. Results on the 4-fold forbidden beta decay of {sup 113}Cd and a variety of double beta decay limits of Cd, Zn and Te isotopes are presented based on 18 kgxdays of exposure with an array of sixteen CdZnTe semiconductor detectors. A short description on the activities with pixelated detectors for tracking is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hard Silicon for Medical, Space and High Energy Physics Applications

The objective of this paper is to give an overview on how silicon particle detector would survive operational in extremely harsh radiation environment after luminosity upgrade of the CERN LHC (Large Hadron Collider). The Super-LHC would result in an integrated fluence 1 x 10{sup 16} p/cm{sup 2} and that is well beyond the radiation tolerance of even the most advanced semiconductor detectors fabricated by commonly adopted technologies. The Czochralski silicon (Cz-Si) has intrinsically high oxygen concentration. Therefore Cz-Si is considered as a promising material for the tracking systems in future very high luminosity colliders. The fabrication process issues of Cz-Si are discussed and the formation of thermal donors is especially emphasized. N{sup +}/p{sup -}/p{sup +} and p{sup +}/n{sup -}/n{sup +} detectors have been processed on magnetic Czochralski (MCz-Si) wafers. We show measurement data of AC-coupled strip detectors and single pad detectors as well as experimental results of intentional TD doping. Data of spatial homogeneity of electrical properties, full depletion voltage and leakage current, is shown and n and p-type devices are compared. Our results show that it is possible to manufacture high quality n{sup +}/p{sup -}/p{sup +} and p{sup +}/n{sup -}/n{sup +} particle detectors from high resistivity Czochralski silicon.

43 PARTICLE ACCELERATORS↗

Updates on activities since the Durham meeting and status of the COBRA experiment

This article consists of two parts. The first one is an update on activities since the Durham meeting. The aim of this meeting was to investigate experiments which should or could be performed to provide viable input for the nuclear matrix element calculations. The second part describes the status of the COBRA double beta decay experiment, using CdZnTe semiconductor detectors for the search.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy resolution in semiconductor gamma radiation detectors using heterojunctions and methods of use and preparation thereof

In one embodiment, a system comprises a semiconductor gamma detector material and a hole blocking layer adjacent the gamma detector material, the hole blocking layer resisting passage of holes therethrough. In another embodiment, a system comprises a semiconductor gamma detector material, and an electron blocking layer adjacent the gamma detector material, the electron blocking layer resisting passage of electrons therethrough, wherein the electron blocking layer comprises undoped HgCdTe. In another embodiment, a method comprises forming a hole blocking layer adjacent a semiconductor gamma detector material, the hole blocking layer resisting passage of holes therethrough. Additional systems and methods are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the activity of a {sup 51}Cr neutrino source based on the gamma-radiation spectrum

A technique for the measurement of activities of intense β sources by measuring the continuous gamma-radiation (internal bremsstrahlung) spectra is developed. A method for reconstructing the spectrum recorded by a germanium semiconductor detector is described. A method for the absolute measurement of the internal bremsstrahlung spectrum of {sup 51}Cr is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the activity and spectrum of internal bremsstrahlung of a {sup 51}Cr source

The activity of the {sup 51}Cr source in the BEST experiment searching for sterile neutrinos is planned to be determined by measuring the spectrum of internal bremsstrahlung. The measurements of activity and the spectrum of internal bremsstrahlung of point low-activity {sup 51}Cr sources with Ge semiconductor detectors are discussed. The accuracy and errors of this measurement method are examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concept of a charged fusion product diagnostic for NSTX

The concept of a new diagnostic for NSTX to determine the time dependent charged fusion product emission profile using an array of semiconductor detectors is presented. The expected time resolution of 1-2 ms should make it possible to study the effect of magnetohydrodynamics and other plasma activities (toroidal Alfven eigenmodes (TAE), neoclassical tearing modes (NTM), edge localized modes (ELM), etc.) on the radial transport of neutral beam ions. First simulation results of deuterium-deuterium (DD) fusion proton yields for different detector arrangements and methods for inverting the simulated data to obtain the emission profile are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Tests for the Detection of the LINAC Irradiation Field Using PIN Diodes

The employment of the technology of semiconductor detectors, in the medical physics environment is of great importance due to its versatility and dependability. In this work we present the first results and the experimental arrangement employed with PIN diodes that are conditioned for the measurement of the field of irradiation of a lineal accelerator (LINAC) used in radiotherapy. In our tests we used a PIN photodiode. In former experiments, this diode presented a response to the intensity of the applied field when it was exposed to an X-ray beam in medical and industrial radiography equipments. This diode is a low cost and easy acquisition one in the field. These characteristics transform it into a serious candidate as detector to be used in electronic arrangements for the detection of radiation fields in radio-therapy with X-rays. Experiments were designed to obtain the response of this diode when it was exposed to X-ray beams of a LINAC used in radiotherapy. Firstly the tests were carried out for a 6 MeV photon beam with a source to surface distance (SSD) of 100 cm, obtaining very encouraging results. We seek to carry out tests for more energy values in order to obtain the energy response of this detector as a radiation sensor device. This device could be applied in the design of working tools, for example, for the quality control in procedures of radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of highly ionizing particles: Nonlinear near-surface phenomena in silicon radiation detectors

As far as the detection system is concerned, experimens on synthesis and study of the properties of superheavy nuclei is one of the most difficult tasks. In fact, these experiments can be considered extreme in many senses: —extremely low (fractions of a picobarn-picobarns) formation cross sections of the products under investigation —extremely high heavy ion beam intensities for example, ∼1.1–1.5 pμA{sup 1} {sup 48}Ca —high radioactivity of actinide targets, which are used in the experiments aimed at the synthesis of super-heavy nuclei —very long duration of the experiment (as long as a year) —extremely low yield of the products under investigation (sometimes less than 1 per month) —very high sensitivity of the detection system —radical suppression of the background products (method of “active correlations”). The two last points are the subject of the present paper, as well as the subject of two of my reviews published before. It is evident that without knowledge of the nature of the internal processes in semiconductor detectors it is virtually impossible to provide clear detection of ultra rare signals. In the present paper, the author reports on the investigation of near-surface phenomena in silicon radiation detectors, first of all bearing in mind the theoretical-methodological aspect of these phenomena. Non-equilibrium electron-hole recombination, pulse height defect formation, charge multiplication, and formation of “hot” electron system, are considered. With just these phenomena one can observe nonlinearity of energy-charge-amplitude conversion for heavy ion (recoil nucleus) registered by a silicon detector. Practical applications are also considered. One of them is a deeply modified method of “active correlations”. Projection of applying the method in the experiments with the modernized cyclotron (DC-280 FLNR project) is projected as well as possible applications in the heavy-ion-induced complete fusion nuclear reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel programmable power supply with temperature compensation for silicon sensors

Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The proposed design also has the capability of gain stabilization of devices with non-linear thermal response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗