Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Comparison Between Simulated And Experimental Au-ion Profiles Implanted in nanocrystalline ceria

Radiation response of nanocrystalline ceria films deposited on a silicon substrate was investigated under a 3-MeV Au-ion irradiation at 300 K. A uniform grain growth cross the ceria films is observed and effective densification of the ceria thin films occurs during irradiation. The Au ion profiling was measured by secondary ion mass spectrometry (SIMS) and compared to the Au ion distribution predicted by the Stopping and Range of Ions in Solids (SRIM) code. It is observed that the Au-ion penetration depth is underestimated in comparison with the SIMS measurements. An overestimation of the electronic stopping power for heavy incident ions in the SRIM program may account for the discrepancies between the calculations and the SIMS experimental results. This work presents an approach to compensate the overestimation of the electronic stopping powers in the SRIM program by adjusting the nanocrystalline ceria target density to better predict the ion implantation profile.

Environmental Molecular Sciences Laboratory↗

Uncertainty quantification in (α,n) neutron source calculations for an oxide matrix

Here we present a methodology to propagate nuclear data covariance information in neutron source calculations from (α,n) reactions. The approach is applied to estimate the uncertainty in the neutron generation rates for uranium oxide fuel types due to uncertainties on 1) 17,18 O( α,n) reaction cross sections and 2) uranium and oxygen stopping power cross sections. The procedure to generate reaction cross section covariance information is based on the Bayesian fitting method implemented in the R-matrix SAMMY code. The evaluation methodology uses the Reich-Moore approximation to fit the 17,18 O(α,n) reaction cross-sections in order to derive a set of resonance parameters and a related covariance matrix that is then used to calculate the energydependent cross section covariance matrix. The stopping power cross sections and related covariance information for uranium and oxygen were obtained by the fit of stopping power data in the -energy range of 1 keV up to 12 MeV. Cross section perturbation factors based on the covariance information relative to the evaluated 17,18 O( α,n) reaction cross sections, as well as uranium and oxygen stopping power cross sections, were used to generate a varied set of nuclear data libraries used in SOURCES4C and ORIGEN for inventory and source term calculations. The set of randomly perturbed output (α,n) source responses, provide the mean values and standard deviations of the calculated responses reflecting the uncertainties in nuclear data used in the calculations. Lastly, the results and related uncertainties are compared with experiment thick target (α,n) yields for uranium oxide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy-range relation and mean energy variation in therapeutic particle beams

Analytical expressions for the mean energy and range of therapeutic light ion beams and low- and high-energy electrons have been derived, based on the energy dependence of their respective stopping powers. The new mean energy and range relations are power-law expressions relevant for light ion radiation therapy, and are based on measured practical ranges or known tabulated stopping powers and ranges for the relevant incident particle energies. A practical extrapolated range, R{sub p}, for light ions was defined, similar to that of electrons, which is very closely related to the extrapolated range of the primary ions. A universal energy-range relation for light ions and electrons that is valid for all material mixtures and compounds has been developed. The new relation can be expressed in terms of the range for protons and alpha particles, and is found to agree closely with experimental data in low atomic number media and when the difference in the mean ionization energy is low. The variation of the mean energy with depth and the new energy-range relation are useful for accurate stopping power and mass scattering power calculations, as well as for general particle transport and dosimetry applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of bulk and pitcher-catcher targets for laser-driven neutron production

Laser-driven d(d, n)-{sup 3}He beam-target fusion neutron production from bulk deuterated plastic (CD) targets is compared with a pitcher-catcher target scheme using an identical laser and detector arrangement. For laser intensities in the range of (1-3) x 10{sup 19} W cm{sup -2}, it was found that the bulk targets produced a high yield (5 x 10{sup 4} neutrons per steradian) beamed preferentially in the laser propagation direction. Numerical modeling shows the importance of considering the temperature adjusted stopping powers to correctly model the neutron production. The bulk CD targets have a high background target temperature leading to a reduced stopping power for the deuterons, which increases the probability of generating neutrons by fusion. Neutron production from the pitcher-catcher targets was not as efficient since it does not benefit from the reduced stopping power in the cold catcher target. Also, the inhibition of the deuteron acceleration by a proton rich contamination layer significantly reduces the pitcher-catcher neutron production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-Consistent Simulation of Transport and Energy Deposition of Intense Laser-Accelerated Proton Beams in Solid-Density Matter

Here, the first self-consistent hybrid particle-in-cell (PIC) simulation of intense proton beam transport and energy deposition in solid-density matter is presented. Both the individual proton slowing-down and the collective beam-plasma interaction effects are taken into account with a new dynamic proton stopping power module that has been added to a hybrid PIC code. In this module, the target local stopping power can be updated at each time step based on its thermodynamic state. For intense proton beams, the reduction of target stopping power from the cold condition due to continuous proton heating eventually leads to broadening of the particle range and energy deposition far beyond the Bragg peak. For tightly focused beams, large magnetic field growth in collective interactions results in self-focusing of the beam and much stronger localized heating of the target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-171: Manufacturing Cost Effective Heterogeneous Phantoms for Use in Proton Therapy

Purpose: To study the feasibility of 3D printing cost effective heterogeneous phantoms for use in proton therapy treatment planning quality assurance. Methods: A desktop 3D printer was utilized to create a series of 2 cm × 2 cm × 4 cm PLA plastic blocks of varying fill materials and hexagonal fill pattern. The blocks were than tested when filled with air, polyurethane foam, paraffin, silicone, and caulk of calcium carbonate – acrylic polymer blend. The blocks were evaluated with a “GE Lightspeed” 16 slice CT scanner and average CT# of the materials’ centers evaluated. Blocks were then placed into a custom aperture fitted to a Mevion Proton system to determine the relative stopping power of each. Scans were performed in water tank with Marcus type parallel plate chamber under a beam with a range of 15 cm and modulation of 2 cm. Shifts in range occurring relative to the 80% distal edge of the open SOBP were evaluated. Results: The CT#s of the blocks were plotted against their measured relative stopping power. This curve was compared to that which is in clinical use. While the trend agrees generally, specific differences between the relative stopping powers were as great as 10%. Conclusion: We have demonstrated that it is possible to utilize different cost effective materials in the manufacturing of phantoms for use in proton therapy. While different materials may provide better agreement to established calibration curves, a custom curve specific to the materials used may be utilized to accurately predict proton treatment dose distributions.

60 APPLIED LIFE SCIENCES↗

SU-F-19A-10: Recalculation and Reporting Clinical HDR 192-Ir Head and Neck Dose Distributions Using Model Based Dose Calculation

Purpose: To retrospectively re-calculate dose distributions for selected head and neck cancer patients, earlier treated with HDR 192Ir brachytherapy, using Monte Carlo (MC) simulations and compare results to distributions from the planning system derived using TG43 formalism. To study differences between dose to medium (as obtained with the MC code) and dose to water in medium as obtained through (1) ratios of stopping powers and (2) ratios of mass energy absorption coefficients between water and medium. Methods: The MC code Algebra was used to calculate dose distributions according to earlier actual treatment plans using anonymized plan data and CT images in DICOM format. Ratios of stopping power and mass energy absorption coefficients for water with various media obtained from 192-Ir spectra were used in toggling between dose to water and dose to media. Results: Differences between initial planned TG43 dose distributions and the doses to media calculated by MC are insignificant in the target volume. Differences are moderate (within 4–5 % at distances of 3–4 cm) but increase with distance and are most notable in bone and at the patient surface. Differences between dose to water and dose to medium are within 1-2% when using mass energy absorption coefficients to toggle between the two quantities but increase to above 10% for bone using stopping power ratios. Conclusion: MC predicts target doses for head and neck cancer patients in close agreement with TG43. MC yields improved dose estimations outside the target where a larger fraction of dose is from scattered photons. It is important with awareness and a clear reporting of absorbed dose values in using model based algorithms. Differences in bone media can exceed 10% depending on how dose to water in medium is defined.

60 APPLIED LIFE SCIENCES↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MPRAD: A Monte Carlo and ray-tracing code for the proton radiography in high-energy-density plasma experiments

Proton radiography is used in various high-energy-density (HED) plasma experiments. In this paper, we describe a Monte Carlo and raytracing simulation tool called multimegaelectronvolt proton radiography (MPRAD) that can be used for modeling the deflection of proton beams in arbitrary three dimensional electromagnetic fields as well as the diffusion of the proton beams by Coulomb scattering and stopping power. Specifically, the Coulomb scattering and stopping power models in cold matter and fully ionized plasma are combined using interpolation. We discuss the application of MPRAD in a few setups relevant to HED plasma experiments where the plasma density can play a role in diffusing the proton beams and affecting the prediction and interpretation of the proton images. It is shown how the diffusion due to plasma density can affect the resolution and dynamical range of the proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray diffraction study of the damage induced in yttria-stabilized zirconia by swift heavy ion irradiations

The lattice damage was investigated by x-ray diffraction techniques in yttria-stabilized zirconia single crystals with the (100) or (110) orientation upon irradiation with swift heavy ions (from 100-MeV C to 2.6-GeV U) in a broad electronic stopping power range (from about 0.3 to 48 keV nm{sup -1}). The {theta}-2{theta} scans show that no amorphization or change to a new crystalline phase occurs regardless of the ion and crystal features. However, the rocking curves ({omega} scans) and reciprocal space mappings show evidence of the mosaicity of the crystals, which is produced above a threshold electronic stopping power between 18 and 27 keV nm{sup -1}. This threshold is in agreement with our previous Rutherford backscattering spectroscopy/channeling spectroscopy data. Two kinds of damage phenomena are found: (i) nuclear-collision induced clusters of point defects which generate Bragg peak shifts and broadening in the 2{theta}-{omega} and {theta}-2{theta} scans, and (ii) electronic-excitation induced lattice damage yielding broad peaks in the {omega} scans above the stopping power threshold at high fluences.

36 MATERIALS SCIENCE↗

Plasmon excitation in metal slab by fast point charge: The role of additional boundary conditions in quantum hydrodynamic model

We study the wake effect in the induced potential and the stopping power due to plasmon excitation in a metal slab by a point charge moving inside the slab. Nonlocal effects in the response of the electron gas in the metal are described by a quantum hydrodynamic model, where the equation of electronic motion contains both a quantum pressure term and a gradient correction from the Bohm quantum potential, resulting in a fourth-order differential equation for the perturbed electron density. Thus, besides using the condition that the normal component of the electron velocity should vanish at the impenetrable boundary of the metal, a consistent inclusion of the gradient correction is shown to introduce two possibilities for an additional boundary condition for the perturbed electron density. We show that using two different sets of boundary conditions only gives rise to differences in the wake potential at large distances behind the charged particle. On the other hand, the gradient correction in the quantum hydrodynamic model is seen to cause a reduction in the depth of the potential well closest to the particle, and a reduction of its stopping power. Even for a particle moving in the center of the slab, we observe nonlocal effects in the induced potential and the stopping power due to reduction of the slab thickness, which arise from the gradient correction in the quantum hydrodynamic model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Varying Quantum Degeneracy in Plasmas Created at the National Ignition Facility [Slides]

Physically realized electron gas systems usually reside in either the quantum non-degenerate or fully degenerate limit, where the average de Broglie wavelength of the thermal electrons becomes comparable with the interparticle distance between electrons. A few systems, such as young brown dwarfs and the cold dense fuels created in imploded cryogenic capsules at the National Ignition Facility, lie between these two limits and are partially degenerate. The National Ignition Facility has the unique capability of varying the electron quantum degeneracy by adjusting the laser drive used to implode the capsules. This allows experimental studies of the effects of the degeneracy level on plasma transport properties. By measuring rare nuclear reactions in these cold dense fuels, we show that the electron stopping power, which is the rate of energy loss per unit distance travelled by a charged particle, changes with increasing electron density. We observe a quantum-induced shift in the peak of the stopping power using diagnostics that measure above and below this peak. The observed changes in the stopping power are shown to be unique to the transition region between non-degenerate and degenerate plasmas. Our results support the screening models applied to partially degenerate astrophysical systems such as young brown dwarfs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e

A graphite flat cavity ionization chamber is used at the BIPM in France to determine the absorbed dose to graphite in a {sup 60}Co photon beam and thereby used to determine the product of the value of W/e, the average energy required to produce an ion pair in dry air, and the value of (L{sub {Delta}}/{rho}){sub a}{sup C}, the mean restricted mass collision stopping-power ratio for graphite to air in a {sup 60}Co beam. The accuracy of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value thus determined depends upon the accuracy of the perturbation correction factors adopted for this chamber. The perturbation effect of this chamber was accounted for by the replacement correction factor whose value was calculated by an analytical method and confirmed by an EGS4 Monte Carlo calculation. The purpose of this study is to investigate the validity of the analytical and the EGS4 calculations by using recently established methods and the EGSnrc Monte Carlo code, a much improved version of EGS4, to calculate the replacement correction factors for the graphite chamber. It is found that the replacement correction factors used for the BIPM chamber are not correct: the values used are smaller than they should be by about 1%. This leads to a 1% overestimation of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value determined by using this chamber. This implies that {sup 60}Co air kerma standards that are directly proportional to this product need to be reduced by 1%. Based on the values of the replacement correction factors calculated in this study, and on the value of (L{sub {Delta}}/{rho}){sub a}{sup C} evaluated from ICRU Report No. 37 stopping power for graphite, the value of W/e determined by using the BIPM chamber should be 33.61{+-}0.08 J/C. If a more recent value of mean excitation energy for graphite (86.8 eV) and grain density are used to evaluate the graphite stopping power, then the value obtained for W/e is 34.15{+-}0.08 J/C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 10: Towards LET detection: A study on the effects of scintillator doping

Purpose: In radiotherapy, the amount of radiation delivered is determined by optimizing the amount of absorbed dose to the tumor. Dose does not always correlate well with the actual biological effects of radiation. This work seeks to validate the LET-dependence of doped plastic scintillators for use in a radiation beam quality (LET) detector. Methods: The LET spectrum ([Φ]) can be resolved knowing the measured signals of uniquely LET-dependent detectors, [S], and the response of each LET-dependent detector to specific LETs ([R]), through the relation [Φ]=[S][R]{sup −1}. Plastic scintillator response is intrinsically LET dependent and can be varied via doping. Initial prototype consists of plastic scintillator and glass taper coupled to an optical fiber; components are housed in black acrylic, reducing effect of ambient light. In order to determine [R], the light response matrix, GEANT4.10.1 Monte Carlo (MC) was used. To validate MC, measurements were done using high energy electrons (9,12,15MeV) and orthovoltage x-rays (100,250kV); scintillator signal was normalized to dose measured simultaneously. Results: Stopping power was varied by changing particle type/energy; measurements indicated that as stopping power increased from 1.9 to 6.6MeV/cm, detector response increased by 263% (+/−29.2%) for 5%Pb-doped scintillator (155% in MC); 52% (+/−7.8%) increase observed when undoped scintillator was used (49% in MC). 5%Pb-doped discrepancy (100kV x-rays) is being investigated. Conclusions: This work validates that doping effects LET/energy response of scintillators; an effect that can be utilized for construction of an LET detector.

60 APPLIED LIFE SCIENCES↗

Evaluation of the mean excitation energy of liquid argon

Current and future experiments need to know the stopping power of liquid argon. It is used directly in calibration, where commonly the minimum-ionizing portion of muon tracks is used as a standard candle. Similarly, muon range is used as a measure of muon energy. More broadly, the stopping power figures into the simulation of all charged particles, and so uncertainty propagates widely throughout data analysis of all sorts. The main parameter that controls stopping power is the mean excitation energy, or I-value. Experimental information for argon's I-value come primarily from measurements of gaseous argon, with a very limited amount of information from solid argon, and none from liquid argon. These measurements are reviewed, along with a discussion of the difference in central value and uncertainty incurred by the difference of phase. The values newly recommended by this note are $(188 \pm 6)$ eV for gaseous argon and $(197 \pm 8)$ eV for liquid argon (68% C.L. in each case).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of Strontium Titanate to Ion and Electron Irradiation

Response of strontium titanate (SrTiO3) to ion and electron irradiation is studied at room temperature. For an accurate energy to depth conversion and a better determination of ion-induced disorder profile from Rutherford backscattering spectrometry measurement, a detailed iterative procedure is described and applied to ion channeling spectra to determine the dechanneling yield and the disorder profiles for the Sr and Ti sublattices. The result shows a large underestimation in disorder depth, ~ 40% at the damage peak, which indicates a large overestimation of the electronic stopping power for 1.0 MeV Au ions in SrTiO3 predicted by the SRIM (Stopping and Range of Ions in Matter) code. Overestimation of heavy ion stopping power may lead to an overestimation of the critical dose for amorphization. The current study also demonstrates possible ionization effects in SrTiO3 under ion and electron irradiation. Pre-amorphized SrTiO3 exhibits strong ionization-induced epitaxial recovery at the amorphous/crystalline interface under electron irradiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Number-conserving linear-response study of low-velocity ion stopping in a collisional magnetized classical plasma

The results of a theoretical investigation of the low-velocity stopping power of ions in a magnetized collisional and classical plasma are reported. The stopping power for an ion is calculated through the linear-response (LR) theory. The collisions, which lead to a damping of the excitations in the plasma, are taken into account through a number-conserving relaxation time approximation in the LR function. In order to highlight the effects of collisions and magnetic field, we present a comparison of our analytical and numerical results obtained for nonzero damping or magnetic field with those for vanishing damping or magnetic field. It is shown that the collisions remove the anomalous friction obtained previously [Nersisyan et al., Phys. Rev. E 61, 7022 (2000)] for the collisionless magnetized plasmas at low ion velocities. One of the major objectives of this paper is to compare and to contrast our theoretical results with those obtained through a diffusion coefficient formulation based on the Dufty-Berkovsky relation evaluated for a magnetized one-component plasma modeled with target ions and electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of chemical disorder on the electronic stopping of solid solution alloys

The electronic stopping power of nickel-based equiatomic solid solutions alloys NiCr, NiFe and NiCo for protons and alpha projectiles is investigated in detail using real-time time-dependent density functional theory over a wide range of velocities. Recently developed numerical electronic structure methods are used to probe fundamental aspects of electron-ion coupling non-perturbatively and in a fully atomistic context, capturing the effect of the atomic scale disorder. The effects of particular electronic band structures and density of states reflect in the low velocity limit behavior. We compare our results for the alloys with those of a pure nickel target to understand how alloying affects the electronic stopping. We discover that NiCo and NiFe have similar stopping behavior as Ni while NiCr has an asymptotic stopping power that is more than a factor of two larger than its counterparts for velocities below 0.1 a.u.. Overall, we show that the low-velocity limit of electronic stopping power can be manipulated by controlling the broadening of the d-band through the chemical disorder. In this regime, the Bragg’s additive rule for the stopping of composite materials also fails for NiCr.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗