Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STABLE BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Proton beam production by a laser ion source with hydride target

We studied proton beam production from a laser ion source using hydrogen rich target materials. In general, gas based species are not suitable for laser ion sources since formation of a dense laser target is difficult. In order to achieve reliable operation, we tested hydride targets using a sub nanosecond Q-switched Nd-YAG laser, which may help suppress target material consumption. We detected enough yields of protons from a titanium hydride target without degradation of beam current during the experiment. The combination of a sub nanosecond laser and compressed hydride target may provide stable proton beam.

43 PARTICLE ACCELERATORS↗

Quantification and purification of isotopic contamination at the ReAccelerator of the Facility for Rare Isotope Beams

At the ReAccelerator within the Facility for Rare Isotope Beams, a combination of an interchangeable aluminum foil and a silicon detector was developed to quantify isobaric contamination in rare isotope beams. The device is simple to operate and is now used routinely. In this article, we describe the system and show an application of the device to determine the level of contamination of an Si-32 rare isotope beam by stable S-32. In addition, we describe how the new diagnostic device helped confirm an enhancement of the beam purity prior to beam delivery to experiments.

Instruments & Instrumentation↗

Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). Furthermore, it is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning technique using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

43 PARTICLE ACCELERATORS↗

High Specific Activity Sm-153 By Post Irradiation Isotope Separation (Final Scientific Technical Report)

The isotope, samarium-153 ( 153 Sm) has ideal nuclear properties well suited for a variety of therapeutic applications; however, it is only available with low specific activity (radioactivity per unit mass) due to the method of production. Commercially useful quantities can be made by the 152 Sm (n,γ) 153 Sm reaction in a nuclear reactor, but typical irradiation parameters result in less than 2% of the 152 Sm target material being converted, leading to a very diluted end product. Since chemical processing methods cannot be used to perform isotopic separation, this means that >98% of the resultant pharmaceutical molecules are labeled with “cold” target atoms and are incapable of providing any radiation-induced therapeutic effect. The goals of this project were to introduce a new approach to the production of high specific activity (HSA) 153 Sm utilizing electromagnetic isotope separation (EMIS), and to perform biodistribution and chemistry studies with such HSA 153 Sm to test labeling capability with targeting molecules. Included in these studies was the successful development of a collection substrate that would allow the efficient deposit and removal of 153 Sm; to this end, DLC (diamond like carbon) foils were successfully employed. In the first year of this project a surface ion source was developed, leading to the successful production of a mass separated beam of stable Sm ions. Studies were then performed using similar apparatus at the Oak Ridge National Laboratory, leading to a well-separated beam of isotopically pure samarium ions. This was followed by the successful production of four 15 mCi samples (over a 7 month period) of HSA 153 Sm which were delivered to the IsoTherapeutics Group for biodistribution and chemical labeling studies. Such samples were produced by neutron irradiation of 5 mg metal samples of 152 Sm at the HFIR (ORNL High Flux Isotope Reactor), followed by manual transfer of the samples from the irradiation capsule to the chamber of a surface ion source. Isotopic beams were then extracted using the IRIS2 EMIS facility, and collected onto 10 μm thick DLC foils. The samples were irradiated for 10 h periods, with typical collection periods lasting 12 - 16 h. Employing appropriate chemical approaches, these HSA 153 Sm samples were evaluated for labeling with small, medium and large molecules. The ability to label a variety of targeting molecules is important to demonstrate the potential therapeutic capabilities. Biodistribution studies, using HSA 153 Sm with the bone agent DOTMP, in rodents demonstrated that the biodistribution is similar to what is observed with LSA 153 Sm. Labeling was successfully achieved with peptides, and large protein molecules.

07 ISOTOPE AND RADIATION SOURCES↗

Low energy beam transport for facility for rare isotope beams driver linear particle accelerator

The driver linac for the facility for rare isotope beams (FRIB) will provide a wide range of primary ion beams for nuclear physics research. The linac will be capable of accelerating a uranium beam to an energy of up to 200 Mev/u and delivering it to a fragmentation target with a maximum power of 400 kW. Stable ion beams will be produced by a high performance electron cyclotron resonance ion source operating at 28 GHz. The ion source will be located on a high voltage platform to reach an initial beam energy of 12 keV/u. After extraction, the ion beam will be transported vertically down to the linac tunnel in a low energy beam transport (LEBT) system and injected into a radio frequency quadrupole (RFQ) operating at a frequency of 80.5 MHz. To meet the beam power requirements, simultaneous acceleration of two-charge states will be used for heavier ions ({>=}Xe). This paper presents the layout of the FRIB LEBT and the beam dynamics in the LEBT. In particular, simulation and design of the beam line section before charge state selection will be detailed. The need to use an achromatic design for the charge state selection system and the advantage of an ion beam collimation system to limit the emittance of the beam injected into the RFQ will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Suppression of Beam Hosing in Plasma Accelerators with Ion Motion

Mitigation of the beam hose instability in plasma-based accelerators is required for the realization of many applications, including plasma-based colliders. The hose instability is analyzed in the blowout regime including plasma ion motion, and ion motion is shown to suppress the hose instability by inducing a head-to-tail variation in the focusing force experienced by the beam. Furthermore, stable acceleration in plasma-based accelerators is possible, while, by use of proper bunch shaping, minimizing the energy spread and preserving the transverse beam emittance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reasonable Beam Deviation Envelope for Ray-tracing

At NSLS-II the unused dipole radiation is intercepted by the photon absorbers installed inside the vacuum chamber. The water-cooled absorbers are designed to take away the heat therefore the temperature is kept within the safety limit. However, if the beam orbit is severely perturbed, the radiation fan could pass through the geometry and strikes on the vacuum chamber components. This ray-leakage is a possible reason of the accelerator component temperature rise observed during the high-current operations. The goal of this work is to find the maximum beam deviation at the dipole hence ray-tracing can be re-examined under the operational constraints. The beam is confined to the orbit by the bending and focusing magnets. At NSLS-II the orbit is further controlled by a real time orbit feedback loop. Beam could be lost in any unpredictable direction if the magnet malfunctions. Consequently reasonable assumptions must be made to define the deviation envelope. It was determined that the dipole radiation is not powerful enough to cause damage within 10 ms, for example, if the rf power is shut off and the beam deviates from the orbit. Therefore we consider the radiation produced by the stored beam only; temporarily processes, such as unstable oscillating beam, should not be a concern. The orbit of the stored beam can be altered during magnet failures. The dipole current is interlocked to a small range of ±2% from the nominal value. If the dipole current changes slowly the beam energy automatically adjusts and the orbit remains the same. If the dipole current changes rapidly the beam will not be stable. Therefore dipole variation need not to be considered. For the other magnets we consider one magnet failure at a time because it is unlikely that two fail at the same time. It was found that the beam lifetime drops dramatically if one quadrupole power supply is turned off; therefore this scenario does not meet the stable beam condition. The current of one quadrupole could drop but will not result in orbit change with the feedback on. Beam could survive if one sextupole power supply is turned off, but the orbit will not be changed. Magnet could partially fail, for example, one or part of the coil shorts due to break-down. This is a low probability event and will not be considered. During daily operations the orbit is changed by the correctors and the rf frequency. In this work the correctors and the rf frequency are varied to explore the deviation envelope.

36 MATERIALS SCIENCE↗

Feedback Requirements for SASE-FELs

The operation of a Self Amplified Spontaneous Emission (SASE) Free Electron Lasers (FEL) at soft and hard X-ray wavelengths driven by a high brightness electron beam imposes strong requirements on the stability of the accelerator and feedback systems are necessary to both guarantee saturation of the SASE process as well as a stable photon beam for user experiments. Diagnostics for the relevant transverse and longitudinal beam parameters are presented and various examples of feedback systems for bunches with low repetition rate as well as systems for intra bunch train feedbacks are discussed.

43 PARTICLE ACCELERATORS↗

Study on the steady operating state of a micro-pulse electron gun

Micro-pulse electron gun (MPG) employs the basic concept of multipacting to produce high-current and short-pulse electron beams from a radio-frequency (RF) cavity. The concept of MPG has been proposed for more than two decades. However, the unstable operating state of MPG vastly obstructs its practical applications. This paper presents a study on the steady operating state of a micro-pulse electron gun with theory and experiments. The requirements for the steady operating state are proposed through the analysis of the interaction between the RF cavity and the beam load. Accordingly, a MPG cavity with the frequency of 2856 MHz has been designed, constructed, and tested. Some primary experiments have been finished. Both the unstable and stable operating states of the MPG have been observed. The stable output beam current has been detected at about 3.8 mA. Further experimental study is under way now.

43 PARTICLE ACCELERATORS↗

Fabrication of an electron multiplier utilizing diamond films

High secondary electron yields (sigma=14-27) from polycrystalline diamond films on Mo substrates have been reported previously. We observed that continuous exposure to an electron beam degraded the secondary yield in vacuum as a function of fluence owing to a loss of surface hydrogen. However, the hydrogen partial pressure could be adjusted such that the high secondary yield remained stable during beam exposure. We have constructed a prototype electron multiplier using these diamond films for use in ultrahigh vacuum. A gain of 0.9 times 10(exp 5) has been measured in a d.c. mode. Palladium, titanium and aluminum nitride have been studied for possible dynode substrate materials which might eliminate the need for hydrogen during operation. Total secondary yields as high as 50 were measured from diamond on palladium and sigma was stable at 25 during heating at 700 K in vacuum. Raman spectroscopy and scanning electron microscopy showed that variations in sigma from diamond films on Pd were due to differing concentrations of non-diamond carbon.

Mearini, G. T.↗

Femtosecond single-beam direct laser poling of stable and efficient second-order nonlinear optical properties in glass

We depict a new approach for the localized creation in three dimensions (3D) of a highly demanded nonlinear optical function for integrated optics, namely second harmonic generation. We report on the nonlinear optical characteristics induced by single-beam femtosecond direct laser writing in a tailored silver-containing phosphate glass. The original spatial distribution of the nonlinear pattern, composed of four lines after one single laser writing translation, is observed and modeled with success, demonstrating the electric field induced origin of the second harmonic generation. These efficient second-order nonlinear structures (with χ{sub eff}{sup (2)} ∼ 0.6 pm V{sup −1}) with sub-micron scale are impressively stable under thermal constraint up to glass transition temperature, which makes them very promising for new photonic applications, especially when 3D nonlinear architectures are desired.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phased Array Radiometer Calibration Using a Radiated Noise Source

Electronic beam steering capability of phased array antenna systems offer significant advantages when used in real aperture imaging radiometers. The sensitivity of such systems is limited by the ability to accurately calibrate variations in the antenna circuit characteristics. Passive antenna systems, which require mechanical rotation to scan the beam, have stable characteristics and the noise figure of the antenna can be characterized with knowledge of its physical temperature [1],[2]. Phased array antenna systems provide the ability to electronically steer the beam in any desired direction. Such antennas make use of active components (amplifiers, phase shifters) to provide electronic scanning capability while maintaining a low antenna noise figure. The gain fluctuations in the active components can be significant, resulting in substantial calibration difficulties [3]. In this paper, we introduce two novel calibration techniques that provide an end-to-end calibration of a real-aperture, phased array radiometer system. Empirical data will be shown to illustrate the performance of both methods.

Srinivasan, Karthik↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗

Coulomb Excitation and One-Neutron Transfer Studies of Stable and Radioactive Nuclei at HRIBF-ORNL

Several stable and radioactive nuclei ranging from $A=58$ to 208 were recently studied in inverse kinematics by Coulomb excitation and heavy-ion induced one-neutron transfer at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory. These studies used a CsI-HPGe detector array to detect scattered charged particles and emitted $\gamma$ rays from the in-beam reactions. A Bragg-curve detector was used to measure the energy loss of the various beams through the targets and to measure the radioactive beam compositions. Stable nickel, strontium, zirconium, molybdenum, tin, tellurium, and lead isotopes and neutron-rich radioactive tin and tellurium isotopes were among the nuclei recently studied. Coulomb excitation was used to measure the electromagnetic moments of the first excited states and heavy-ion induced one-neutron transfer was used to measure the absolute cross sections and lifetimes of the excited single-particle states. A sample of these results are presented here with an emphasis on the tin isotopes. In particular, a survey of the Bragg-curve measurements, Doppler corrections, and inconclusive $i_{13/2}$ candidate in $^{133}$\textrm{Sn} are presented.

Allmond, James M↗

Study of Advanced Photocathodes for Highly Polarized Electron Source

GaAs-based photocathodes have been widely used in the photogun to produce spin polarized electron beams. These photocathodes in the photogun are required to provide high quantum efficiency (QE), high degree of electron-spin polarization (ESP) and long lifetime to satisfy demanding requirements of today's electron accelerators. Photocathodes that demonstrate improved performance will enable the successful construction of proposed new accelerators that will enable new physics research. This thesis presents several studies of polarization photocathodes aimed to quantifying and further understanding the limitation of today's GaAs-based photocathodes, and then successfully identifies effective methods to improve their performance to meet the requirements of the state-of-the-art and future advanced electron accelerators. Up to now, the strained superlattice GaAs-based photocathodes is the only material that provide electron beam with high ESP (~90%) for electron accelerators, but its primary drawback is that the QE is low (~1%). These photocathodes have already been successfully used in electron accelerators (such as CEBAF at JLab), but the low QE is very hard to satisfy the urgent demands of some new proposed electron accelerators (such as eRHIC requires the beam current up to 50 mA). Thus, it is extremely urgent to improve greatly the QE of these polarization photocathodes. This thesis reports a high?polarization strained GaAs/GaAsP superlattice photocathode fabricated with Distributed Bragg Reflector (DBR) structure, which successful achieved a breakthrough in the QE (~6%) that is improved several times over the existing QE (~1.2%), while still maintaining high ESP, through stringent parameter design and repeated experimental optimization. This provides important benchmark parameter for several proposed electron accelerators and will significantly shorten the development process for producing mA order of magnitude of electron beam with high polarization. The photocathode lifetime is one of the main factors of modern DC high voltage photogun, and long lifetime provides a necessary condition for photogun to provide a sustained and stable electron beam. Although it has been realized that the lifetime of photocathodes is primarily limited by ion back?bombardment, until now, no systematic studies of the effects of ion back-bombardment on photocathodes have been performed, of which many physical mechanisms are unclear. In this thesis, the sensitivity of QE decay (or lifetime) to ion back-bombardment is studied and evaluated in detail for the first time, giving the important conclusion that the best choice for a photogun using GaAs-based photocathodes would be surface cleave plane (110). This study provides an important theory for II photogun researchers to understand the ion back-bombardment and helps to prolong the operating lifetime of photogun in future. The ESP obtained from typical bulk unstrained GaAs photocathodes is usually considerably less than the theoretical maximum value of 50% because of depolarization (or spin relaxation) mechanisms that originate within the photocathode material and at the vacuum surface interface (i.e. activation layer). This thesis provides a comprehensive review of depolarization mechanisms and presents a systematic experimental evaluation of polarization sensitivities to temperature, dopant density, activation layer and crystal orientation. One of the key findings is that the bulk unstrained GaAs photocathode can provide the highest polarization ~50%, consistent with the maximum theoretical value, when the photocathode sample had relatively low dopant concentration and was cooled to 77 K. This study helps to better understand the mechanisms of polarization loss of electrons in the GaAs photocathode, and benefits to produce electron beam with higher ESP from GaAs photocathode. A novelstrained superlattice structure, GaAsSb/AlGaAs photocathode, is also proposed and studied in this thesis, and some experiments for it have been performed. Although the experimental results are not as good as our expectation, it provides a strong research foundation for future development of high polarization photocathodes. Finally, a brief summary of the work under preparation for generation of mA record-level high-current polarized electron beam from the Upgraded Injector Test Facility (UITF) at JLab is presented.

Liu, Wei↗

Coupling Measurements in ATF2 Extraction Line

The purpose of ATF2 is to deliver a beam with stable very small spotsizes as required for future linear colliders such as ILC or CLIC. To achieve that, precise controls of aberrations such as dispersion and coupling are necessary. Theoretically, the complete reconstruction of the beam matrix is possible from the measurements of horizontal, vertical and tilted beam sizes, combining skew quadrupole scans at several wire-scanner positions. Such measurements were performed in the extraction line (EXT) of ATF2 in May 2009. We present analysis results attempting to resolve the 4 x 4 beam matrix. We aimed to reconstruct the full beam matrix using only skew quadrupole scans at different EXT wire-scanner locations, with measurements of horizontal, vertical and two tilted beam size projections. Checking the coherence of the {sigma}{sub 13} reconstruction from the {sigma}{sub 80{sup o}} and the {sigma}{sub 100{sup o}} measurements was essential to perform this analysis. We have shown that reconstruction of the coupling element can not be performed independantly of the 4 x 4 diagonal ones since it leads to unphysical results. A more accurate and automatisable method was find, leading to physical beam matrix reconstruction, compatible with the measurements. Another analysis should be performed based on a larger number of data sets to minimise statistical errors.

43 PARTICLE ACCELERATORS↗

Cascaded proton acceleration by collisionless electrostatic shock

A new scheme for proton acceleration by cascaded collisionless electrostatic shock (CES) is proposed. By irradiating a foil target with a moderate high-intensity laser beam, a stable CES field can be induced, which is employed as the accelerating field for the booster stage of proton acceleration. The mechanism is studied through simulations and theoretical analysis, showing that a 55 MeV seed proton beam can be further accelerated to 265 MeV while keeping a good energy spread. This scheme offers a feasible approach to produce proton beams with energy of hundreds of MeV by existing available high-intensity laser facilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗