Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Optical spectroscopy and band gap analysis of hybrid improper ferroelectric Ca{sub 3}Ti{sub 2}O{sub 7}

We bring together optical absorption spectroscopy, photoconductivity, and first principles calculations to reveal the electronic structure of the room temperature ferroelectric Ca{sub 3}Ti{sub 2}O{sub 7}. The 3.94 eV direct gap in Ca{sub 3}Ti{sub 2}O{sub 7} is charge transfer in nature and noticeably higher than that in CaTiO{sub 3} (3.4 eV), a finding that we attribute to dimensional confinement in the n = 2 member of the Ruddlesden-Popper series. While Sr substitution introduces disorder and broadens the gap edge slightly, oxygen deficiency reduces the gap to 3.7 eV and gives rise to a broad tail that persists to much lower energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A synthetic diagnostic for beam emission spectroscopy in the helically symmetric experiment stellarator

The Helically Symmetric Experiment (HSX) has a number of active spectroscopy diagnostics. Due to the relatively large beam width compared to the plasma minor radius, it is difficult to achieve good spatial resolution at the core of the HSX plasma. This is due to the fact that the optical sightline cuts through many flux surfaces with varying field vectors within the beam. In order to compare the experimental results with theoretical models it is important to accurately model the beam width effects. A synthetic diagnostic has been developed for this purpose. This synthetic diagnostic calculates the effect of spot size and beam width on the measurements of quantities of interest, including radial electric field, flow velocity, and Stark polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a krypton-doped gas symmetry capsule platform for x-ray spectroscopy of implosion cores on the NIF

The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. Here we describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anharmonic exciton dynamics and energy dissipation in liquid water from two-dimensional infrared spectroscopy

Water’s extended hydrogen-bond network results in rich and complex dynamics on the sub-picosecond time scale. In this paper, we present a comprehensive analysis of the two-dimensional infrared (2D IR) spectrum of O–H stretching vibrations in liquid H{sub 2}O and their interactions with bending and intermolecular vibrations. By exploring the dependence of the spectrum on waiting time, temperature, and laser polarization, we refine our molecular picture of water’s complex ultrafast dynamics. The spectral evolution following excitation of the O–H stretching resonance reveals vibrational dynamics on the 50–300 fs time scale that are dominated by intermolecular delocalization. These O–H stretch excitons are a result of the anharmonicity of the nuclear potential energy surface that arises from the hydrogen-bonding interaction. The extent of O–H stretching excitons is characterized through 2D depolarization measurements that show spectrally dependent delocalization in agreement with theoretical predictions. Furthermore, we show that these dynamics are insensitive to temperature, indicating that the exciton dynamics alone set the important time scales in the system. Finally, we study the evolution of the O–H stretching mode, which shows highly non-adiabatic dynamics suggestive of vibrational conical intersections. We argue that the so-called heating, commonly observed within ∼1 ps in nonlinear IR spectroscopy of water, is a nonequilibrium state better described by a kinetic temperature rather than a Boltzmann distribution. Our conclusions imply that the collective nature of water vibrations should be considered in describing aqueous solvation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Exploring the impact of ions on oxygen K-edge X-ray absorption spectroscopy in NaCl solution using the GW-Bethe-Salpeter-equation approach

X-ray absorption spectroscopy (XAS) is a powerful experimental tool to probe the local structure in materials with the core hole excitations. Here, the oxygen K-edge XAS spectra of the NaCl solution and pure water are computed by using a recently developed GW-Bethe-Salpeter equation approach, based on configurations modeled by path-integral molecular dynamics with the deep-learning technique. The neural network is trained on ab initio data obtained with strongly constrained and appropriately normed density functional theory. The observed changes in the XAS features of the NaCl solution, compared to those of pure water, are in good agreement between experimental and theoretical results. We provided detailed explanations for these spectral changes that occur when NaCl is solvated in pure water. Specifically, the presence of solvating ion pairs leads to localization of electron-hole excitons. As a result, our theoretical XAS results support the theory that the effects of the solvating ions on the H-bond network are mainly confined within the first hydration shell of ions, however beyond the shell the arrangement of water molecules remains to be comparable to that observed in pure water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling liquid solvent structure analysis using hard x-ray absorption spectroscopy with a transferrable microfluidic reactor

In this study, a vacuum compatible microfluidic device, system for analysis at the liquid vacuum interface, is integrated to hard x-ray absorption spectroscopy to obtain the local structure of K 3 [Fe(CN) 6 ] in aqueous solutions with three concentrations of 0.5 M, 0.05 M, and 0.005 M. The solutions were sealed in a microchannel 500 µm wide and 300 µm deep in a portable microfluidic device. The Fe K-edge x-ray absorption spectra indicate a presence of Fe(III) in the complex in water, with an octahedral geometry coordinated with 6 C atoms in the first shell with a distance of ~1.92 Å and 6 N atoms in the second shell with a distance of ~3.10 Å. Varying the concentration has no observable influence on the structure of K 3 [Fe(CN) 6 ]. Our results demonstrate the feasibility of using microfluidic based liquid cells in large synchrotron facilities. Using portable microfludic reactors provides a viable approach to enable multifaceted measurements of liquids in the future.

25 ENERGY STORAGE↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison and Interpretation of Admittance Spectroscopy and Deep Level Transient Spectroscopy from Co-Evaporated and Solution-Deposited Cu2ZnSn(Sx, Se1-x)4 Solar Cells

Cu2ZnSn(S, Se)4 (CZTSe) is an earth-abundant semiconductor with potential for economical thin-film photovoltaic devices. Short minority carrier lifetimes contribute to low open circuit voltage and efficiency. Deep level defects that may contribute to lower minority carrier lifetimes in kesterites have been theoretically predicted, however very little experimental characterization of these deep defects exists. In this work we use admittance spectroscopy (AS) and deep level transient spectroscopy (DLTS) to characterize devices built using CZTSSe absorber layers deposited via both coevaporation and solution processing. AS reveals a band of widely-distributed activation energies for traps or energy barriers for transport, especially in the solution deposited case. DLTS reveals signatures of deep majority and minority traps within both types of samples.

14 SOLAR ENERGY↗

Isotope-Specific Analysis of Neutron-Irradiated Lithium Aluminate Ceramics by Nuclear Magnetic Resonance Spectroscopy

The effects of neutron irradiation on lithium aluminate targets and the permeation of tritium into surrounding components are primary concerns in the development of materials for use in tritium production. The high specific activity and volatility of the tritium in activated samples greatly increase the challenges of experimental analysis. This paper reports the determination of the chemical forms and quantities of H-3 and Li-6 in irradiated and non-irradiated LiAlO2 by nuclear magnetic resonance (NMR) spectroscopy, and demonstrates that measurements can be performed in a non-destructive, safe manner to obtain isotope-selective, quantitative information on highly hazardous materials.

Tritium, solid state nuclear magnetic resonance sp↗

Study of surface cleaning methods and pyrolysis temperatures on nanostructured carbon films using x-ray photoelectron spectroscopy

Nanostructured carbon (ns-C) films fabricated by stabilization and pyrolysis of diblock copolymers are of interest for a variety of electrical/electronic applications due to their chemical inertness, high-temperature insensitivity, very high surface area, and tunable electrical resistivity over a wide range [Kulkarni et al., Synth. Met. 159, 177 (2009)]. Because of their high porosity and associated high specific surface area, controlled surface cleaning studies are important for fabricating electronic devices from these films. In this study, quantification of surface composition and surface cleaning studies on ns-C films synthesized by carbonization of diblock copolymers of polyacrylonitrile-b-poly(n-butyl acrylate) at two different temperatures were carried out. X-ray photoelectron spectroscopy was used for elemental analysis and to determine the efficacy of various surface cleaning methods for ns-C films and to examine the polymer residues in the films. The in-situ surface cleaning methods included HF vapor treatment, vacuum annealing, and exposure to UV-ozone. Quantitative analysis of high-resolution XPS scans showed 11 at. % nitrogen was present in the films pyrolyzed at 600 Degree-Sign C, suggesting incomplete denitrogenation of the copolymer films. The nitrogen atomic concentration decreased significantly for films pyrolyzed at 900 Degree-Sign C confirming extensive denitrogenation at that temperature. Furthermore, quantitative analysis of nitrogen subpeaks indicated higher loss of nitrogen atoms residing at the edge of graphitic clusters relative to that of nitrogen atoms within the graphitic clusters, suggesting higher graphitization with increasing pyrolysis temperature. Of the surface cleaning methods investigated, in-situ annealing of the films at 300 Degree-Sign C for 40 min was found to be the most efficacious in removing adventitious carbon and oxygen impurities from the surface.

36 MATERIALS SCIENCE↗

On the Combined Application of Raman Spectroscopy and Photoluminescence Spectroscopy for the Diagnostics of Multilayer Heterostructures

The results of studying GaInAs/GaInP/GaAs photodiode structures grown by metal–organic vapor-phase epitaxy are reported. A procedure for the diagnostics of such multilayer structures is developed. The procedure is based on the application of Raman spectroscopy in combination with photoluminescence spectroscopy in the mode of the lateral scanning of transverse cleavages. The compositions of the GaInAs and GaInP solid solutions are determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical heterodyne-enhanced chirped laser dispersion spectroscopy

A proof-of-concept heterodyne-enhanced chirped laser dispersion spectroscopy system is presented. In remote sensing systems where low return powers are expected, the addition of an optical local oscillator and subsequent nonlinear processing can provide improved performance in chirped laser dispersion spectroscopy. Here, details about the system configuration, phase noise cancellation, and experimental verification are discussed.

03 NATURAL GAS↗

Single-shot, multi-signature remote detection of uranium by filament-induced breakdown spectroscopy

Filament-induced breakdown spectroscopy (FIBS) is an attractive remote detection approach that is potentially applicable to nuclear materials, such as uranium (U). Simultaneous detection of atomic U and uranium monoxide features is demonstrated in a single laser shot with detection probabilities of 52.2% and 39.0%, respectively, and with a 1% false-alarm probability. It is shown that a nearly 100% detection probability can be reached with 1% false alarm probability in .1 second when using an 80-Hz laser and data acquisition system. Atomic U and UO signal features are identifiable in the remote measurement with comparable signal-to-background ratios, suggesting that, despite being broader than the U I emission line, the UO band is also suitable for remote detection of uranium by FIBS.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Steps to achieving high-resolution NMR spectroscopy on solutions at GPa pressure

Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.

58 GEOSCIENCES↗

Gemini Planet Imager Spectroscopy of the Dusty Substellar Companion HD 206893 B

We present new near-infrared Gemini Planet Imager (GPI) spectroscopy of HD 206893 B, a substellar companion orbiting within the debris disk of its F5V star. The J, H, K1, and K2 spectra from GPI demonstrate the extraordinarily red colors of the object, confirming it as the reddest substellar object observed to date. The significant flux increase throughout the infrared presents a challenging atmosphere to model with existing grids. Best-fit values vary from 1200 to 1800 K for effective temperature and from 3.0 to 5.0 for log(g), depending on which individual wavelength band is fit and which model suite is applied. The extreme redness of the companion can be partially reconciled by invoking a high-altitude layer of submicron dust particles, similar to dereddening approaches applied to the peculiar red field L dwarf population. However, reconciling the HD 206893 B spectra with even those of the reddest low-gravity L dwarf spectra still requires the contribution of additional atmospheric dust, potentially due to the debris disk environment in which the companion resides. Orbit fitting from 4 yr of astrometric monitoring is consistent with a ∼30 yr period, an orbital inclination of 147°, and a semimajor axis of 10 au, well within the estimated disk inner radius of ∼50 au. As one of a very few substellar companions imaged interior to a circumstellar disk, the properties of this system offer important dynamical constraints on companion–disk interaction and provide a benchmark for substellar and planetary atmospheric study.

47 OTHER INSTRUMENTATION↗

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗