Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Long-Wave Infrared Dyson Spectrometer

Preliminary results are presented for an ultra compact long-wave infrared slit spectrometer based on the dyson concentric design. The dyson spectrometer has been integrated in a dewar environment with a quantum well infrared photodetecor (QWIP), concave electron beam fabricated diffraction grating and ultra precision slit. The entire system is cooled to cryogenic temperatures to maximize signal to noise ratio performance, hence eliminating thermal signal from transmissive elements and internal stray light. All of this is done while maintaining QWIP thermal control. A general description is given of the spectrometer, alignment technique and predicated performance. The spectrometer has been designed for optimal performance with respect to smile and keystone distortion. A spectral calibration is performed with NIST traceable targets. A 2-point non-uniformity correction is performed with a precision blackbody source to provide radiometric accuracy. Preliminary laboratory results show excellent agreement with modeled noise equivalent delta temperature and detector linearity over a broad temperature range.

imaging↗

Discriminating Phytoplankton Functional Types (PFTs) in the Coastal Ocean Using the Inversion Algorithm Phydotax and Airborne Imaging Spectrometer Data

There is a need in the Biological Oceanography community to discriminate among phytoplankton groups within the bulk chlorophyll pool to understand energy flow through ecosystems, to track the fate of carbon in the ocean, and to detect and monitor-for harmful algal blooms (HABs). The ocean color community has responded to this demand with the development of phytoplankton functional type (PFT) discrimination algorithms. These PFT algorithms fall into one of three categories depending on the science application: size-based, biogeochemical function, and taxonomy. The new PFT algorithm Phytoplankton Detection with Optics (PHYDOTax) is an inversion algorithm that discriminates taxon-specific biomass to differentiate among six taxa found in the California Current System: diatoms, dinoflagellates, haptophytes, chlorophytes, cryptophytes, and cyanophytes. PHYDOTax was developed and validated in Monterey Bay, CA for the high resolution imaging spectrometer, Spectroscopic Aerial Mapping System with On-board Navigation (SAMSON - 3.5 nm resolution). PHYDOTax exploits the high spectral resolution of an imaging spectrometer and the improved spatial resolution that airborne data provides for coastal areas. The objective of this study was to apply PHYDOTax to a relatively lower resolution imaging spectrometer to test the algorithm's sensitivity to atmospheric correction, to evaluate capability with other sensors, and to determine if down-sampling spectral resolution would degrade its ability to discriminate among phytoplankton taxa. This study is a part of the larger Hyperspectral Infrared Imager (HyspIRI) airborne simulation campaign which is collecting Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) imagery aboard NASA's ER-2 aircraft during three seasons in each of two years over terrestrial and marine targets in California. Our aquatic component seeks to develop and test algorithms to retrieve water quality properties (e.g. HABs and river plumes) in both marine and in-land water bodies. Results presented are from the 10 April 2013 overflight of the Monterey Bay region and focus primarily on the first objective - sensitivity to atmospheric correction. On-going and future work will continue to evaluate if PHYDOTax can be applied to historical (SeaWiFS and MERIS), existing (MODIS, VIIRS, and HICO), and future (PACE, GEO-CAPE, and HyspIRI) satellite sensors. Demonstration of cross-platform continuity may aid in calibration and validation efforts of these sensors.

Biological Oceanography↗

Ultra-Stable Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (5STAR)

The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with diffraction spectroscopy to improve knowledge of atmospheric constituents and their links to airpollution and climate. Direct beam hyperspectral measurement of optical depth improves retrievals of gas constituentsand determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution.Hyperspectral cloud-transmitted radiance measurements enable the retrieval of cloud properties from below clouds.These measurements tighten the closure between satellite and ground-based measurements. 4STAR incorporates amodular sun-tracking sky-scanning optical head with optical fiber signal transmission to rack mounted spectrometers,permitting miniaturization of the external optical tracking head, and future detector evolution.4STAR has supported a broad range of flight experiments since it was first flown in 2010. This experience provides thebasis for a series of improvements directed toward reducing measurement uncertainty and calibration complexity, andexpanding future measurement capabilities, to be incorporated into a new 5STAR instrument. A 9-channel photodioderadiometer with AERONET-matched bandpass filters will be incorporated to improve calibration stability. A wide dynamic range tracking camera will provide a high precision solar position tracking signal as well as an image of sky conditions around the solar axis. An ultrasonic window cleaning system design will be tested. A UV spectrometer tailored for formaldehyde and SO2 gas retrievals will be added to the spectrometer enclosure. Finally, expansion capability for a 4 channel polarized radiometer to measure the Stokes polarization vector of sky light will be incorporated. This paper presents initial progress on this next-generation 5STAR instrument.

atmosphere↗

Second-Generation Design of Micro-Spec: A Medium-Resolution, Submillimeter-Wavelength Spectrometer-on-a-Chip

Micro-Spec (μ-Spec) is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip through the use of superconducting microstrip transmission lines on a single-crystal silicon substrate. A second-generation μ-Spec is being designed to operate with a spectral resolution of 512 in the submillimeter (500-1000 μm, 300-600 GHz) wavelength range, a band of interest for several spectroscopic applications in astrophysics. High altitude balloon missions would provide the first test bed to demonstrate the μ-Spec technology in a space-like environment and would be an economically viable venue for multiple observation campaigns. This work reports on the current status of the instrument design and will provide a brief overview of each instrument subsystem. Particular emphasis will be given to the design of the spectrometer's two-dimensional diffractive region, through which the light of different wavelengths is focused on the detectors along the focal plane. An optimization process is employed to generate geometrical configurations of the diffractive region that satisfy specific requirements on spectrometer size, operating spectral range, and performance. An optical design optimized for balloon missions will be presented in terms of geometric layout, spectral purity, and efficiency.

Cataldo, G.↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz (10¯11) crystal.

M. J. MacDonald↗

Calibration of the SHERLOC Deep Ultraviolet Fluorescence–Raman Spectrometer on the Perseverance Rover

We describe the wavelength calibration of the spectrometer for the scanning of habitable environments with Raman and luminescence for organics and chemicals (SHERLOC) instrument onboard NASA’s Perseverance Rover. SHERLOC utilizes deep ultraviolet Raman and fluorescence (DUV R/F) spectroscopy to enable analysis of samples from the Martian surface. SHERLOC employs a 248.6 nm deep ultraviolet laser to generate Raman-scattered photons and native fluorescence emission photons from near-surface material to detect and classify chemical and mineralogical compositions. The collected photons are focused on a charge-coupled device and the data are returned to Earth for analysis. The compact DUV R/F spectrometer has a spectral range from 249.9 nm to 353.6 nm (200 cm1 to 12, 000 cm1) (with a spectral resolution of 0.296 nm (40 cm1)). The compact spectrometer uses a custom design to project a high-resolution Raman spectrum and a low-resolution fluorescence spectrum on a single charge-coupled device. The natural spectral separation enabled by deep ultraviolet excitation enables wavelength separation of the Raman/fluorescence spectra. The SHERLOC spectrometer was designed to optimize the resolution of the Raman spectral region and the wavelength range of the fluorescence region. The resulting illumination on the charge-coupled device is curved, requiring a segmented, nonlinear wavelength calibration in order to understand the mineralogy and chemistry of Martian materials.

Kyle Uckert↗

Europa Environmental Testing of Thermal Hardware for the Mapping Imaging Spectrometer for Europa (MISE) Instrument

The Europa Clipper spacecraft, scheduled for launch in June 2022, hosts a suite of instruments including the Mapping Imaging Spectrometer for Europa (MISE). MISE is a high-optical through-put pushbroom infrared imaging spectrometer that can collect measurements within Europa’s challenging radiation environment. It is externally mounted to the spacecraft and as a result is exposed to high radiation levels and cold temperatures. The instrument consists of a scan mirror assembly, an optical bench including a Dyson spectrometer and a telescope, and a structure that supports a cryocooler and a radiator. The cryocooler is used to actively cool the focal plane array and the spectrometer. The heat from the cryocooler is rejected through pyrolytic graphite sheet thermal straps to a honeycomb radiator. MISE will implement thermal hardware that will either not be used on other parts of the spacecraft or have a more extreme environment than the spacecraft. As a result, the MISE instrument performed numerous environmental tests on its thermal hardware. This paper discusses the results of the thermal cycling and radiation tests performed on the MISE thermal hardware including a Lockheed Martin Micro1-2 cryocooler, Pyrolytic graphite sheet thermal straps, Annealed pyrolytic graphite K-Core, Rosemount Platinum Resistance Thermometers, Tayco Kapton Thermofoil heaters, Dale Ohm resistors, and aluminum honeycomb and facesheets.

Strong, Patrick↗

Second-generation Micro-Spec: Spectrometer Design for the Experiment for Cryogenic Large-Aperture Intensity Mapping

Micro-Spec (μ-Spec) is a direct-detection spectrometer that integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip using superconducting microstrip transmission lines on a single-crystal silicon substrate. The second-generation μ-Spec has been designed to operate with a spectral resolution of ∼512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA’s EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). EXCLAIM will be a high-altitude balloon mission that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5. EXCLAIM will be the first demonstration of the μ-Spec technology in a space-like environment. This work reviews the status of the μ-Spec design for the EXCLAIM instrument, with emphasis on the spectrometer’s two-dimensional diffractive region, through which light of different wavelengths is focused on microwave kinetic inductance detectors (MKIDs) along the spectrometer focal plane. An optimization process generates a geometrical configuration of the diffractive region that satisfies specific requirements on size, operating spectral range and performance. An initial optical design optimized for EXCLAIM is presented in terms of geometric layout, spectral purity and efficiency.

Giuseppe Cataldo↗

Tropospheric and Airborne Emission Spectrometers

X This paper describes the development of two related instruments, the Tropospheric Emission Spectrometer (TES) and the Airborne Emission Spectrometer (AES). Both instruments are infrared imaging Fourier Transform Spectrometers, used for measuring the state of the lower atmosphere, and in particular the measurement of ozone and ozone sources and sinks.

mission to planet earth global atmospheric models↗

Digital Spectrometers for Interplanetary Science Missions

A fully digital polyphase spectrometer recently developed by the University of California Berkeley Wireless Research Center in conjunction with the Jet Propulsion Laboratory provides a low mass, power, and cost implementation of a spectrum channelizer for submillimeter spectrometers for future missions to the Inner and Outer Solar System. The digital polyphase filter bank spectrometer (PFB) offers broad bandwidth with high spectral resolution, minimal channel-to-channel overlap, and high out-of-band rejection.

polyphase filter bank spectrometer (PFB)↗

A Panchromatic Imaging Fourier Transform Spectrometer for the NASA Geostationary Coastal and Air Pollution Events Mission

This paper summarizes the design and development of the Panchromatic Imaging Fourier Transform Spectrometer (PanFTS) for the NASA Geostationary Coastal and Air Pollution Events (GEO-CAPE) Mission. The PanFTS instrument will advance the understanding of the global climate and atmospheric chemistry by measuring spectrally resolved outgoing thermal and reflected solar radiation. With continuous spectral coverage from the near-ultraviolet through the thermal infrared, this instrument is designed to measure pollutants, greenhouse gases, and aerosols as called for by the U.S. National Research Council Decadal Survey; Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond1. The PanFTS instrument is a hybrid instrument based on spectrometers like the Tropospheric Emissions Spectrometer (TES) that measures thermal emission, and those like the Orbiting Carbon Observatory (OCO), and the Ozone Monitoring Instrument (OMI) that measure scattered solar radiation. Simultaneous measurements over the broad spectral range from IR to UV is accomplished by a two sided interferometer with separate optical trains and detectors for the ultraviolet-visible and infrared spectral domains. This allows each side of the instrument to be independently optimized for its respective spectral domain. The overall interferometer design is compact because the two sides share a single high precision cryogenic optical path difference mechanism (OPDM) and metrology laser as well as a number of other instrument systems including the line-of-sight pointing mirror, the data management system, thermal control system, electrical system, and the mechanical structure. The PanFTS breadboard instrument has been tested in the laboratory and demonstrated the basic functionality for simultaneous measurements in the visible and infrared. It is set to begin operations in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson measuring the atmospheric chemistry across the Los Angeles basin. Development has begun on a flight size PanFTS engineering model (EM) that addresses all critical scaling issues and demonstrates operation over the full spectral range of the flight instrument which will show the PanFTS instrument design is mature.

Imaging spectrometer(↗

The NEID Precision Radial Velocity Spectrometer: Port Adapter Overview, Requirements, and Test Plan

The NEID spectrometer is an optical (380-930 nm), fiber-fed, precision Doppler spectrometer currently in development for the WIYN 3.5 m telescope at Kitt Peak National Observatory as part of the NN-EXPLORE partnership. Designed to achieve a radial velocity precision of < 30 cm/s, NEID will be sensitive enough to detect terrestrial-mass exoplanets around low-mass stars. Light from the target stars is focused by the telescope to a bent Cassegrain port at the edge of the primary mirror mechanical support. The specialized NEID "Port Adapter" system is mounted at this bent Cassegrain port and is responsible for delivering the incident light from the telescope to the NEID fibers. In order to provide stable, high-quality images to the science instrument, the Port Adapter houses several sub-components designed to acquire the target stars, correct for atmospheric dispersion, stabilize the light onto the science fibers, and calibrate the spectrometer by injecting known wavelength sources such as a laser frequency comb. Here we provide an overview of the overall opto-mechanical design and system requirements of the Port Adapter. We also describe the development of system error budgets and testplans to meet those requirements.

Cassegrain port↗

Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers

SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. Here, we present the noise performance of a full R similar to 275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of similar to 3x10 -16 W Hz -1/2 at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020.

47 OTHER INSTRUMENTATION↗

Design of the High Rigidity Spectrometer at FRIB

A High Rigidity Spectrometer (HRS) has been designed for experiments at the Facility for Rare-Isotope Beams (FRIB) at Michigan State University (MSU). The HRS will allow experiments to be performed with the most exotic neutron-rich isotopes at high beam energies (≳100 MeV/u). The HRS consists of an analysis beamline called the High-Transmission Beamline (HTBL) and the spectrometer proper called the Spectrometer Section. Here, the maximum magnetic rigidity of the HRS is 8 Tm, which corresponds to the rigidities at which rare-isotope beams are optimally produced at FRIB. The resolving power, angular acceptance, and momentum acceptance are set to match the anticipated scientific program. An ion-optical design developed for the HRS is described in detail, along with the specifications of the associated magnet and detector systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wideband precision stabilization of the -18.6kV retarding voltage for the KATRIN spectrometer

The Karlsruhe Tritium Neutrino Experiment (KATRIN) measures the effective electron anti-neutrino mass with an unprecedented design sensitivity of 0.2 eV (90 % C.L.). In this experiment, the energy spectrum of beta electrons near the tritium decay endpoint is analyzed with a highly accurate spectrometer. To reach the KATRIN sensitivity target, the retarding voltage of this spectrometer must be stable to the ppm (1 × 10 -6 ) level and well known on various time scales (μs up to months), for values around -18.6 kV. A custom-designed high-voltage regulation system mitigates the impact of interference sources in the absence of a closed electric shield around the large spectrometer vessel. In this article, we describe the regulation system and its integration into the KATRIN setup. Independent monitoring methods demonstrate a stability within 2 ppm, exceeding KATRIN's specifications.

47 OTHER INSTRUMENTATION↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗