Helical Covalent Polymers with Unidirectional Ion Channels as Single Lithium-Ion Conducting Electrolytes

Single-ion conducting polymer electrolytes have attracted great attention as safe alternatives to liquid electrolytes in high energy density lithium-ion batteries. Herein, we report the first example of a crystalline anionic helical polymer as a single lithium-ion conducting solid polymer electrolyte (SPE). Single-crystal X-ray analysis shows that the polymer folds into densely packed double helices, with bundles of unidirectional negatively charged channels formed that can facilitate lithium-ion transportation. Such a helical covalent polymer ( HCP) exhibits excellent room temperature lithium-ion conductivity (1.2 x 10 -3 S cm -1 ) in the absence of external lithium salts, a high transference number (0.84), low activation energy (0.14 eV), and a wide electrochemical stability window (0.2-5 V). We found that nonflammable, nonvolatile ionic liquid can serve as a solvating medium and excellent conductivity enhancer (>1000 times increase). These ion-conducting properties are comparable to the best polyethylene oxide-based polymer electrolytes mixed with lithium salts. Finally, we show that the solvated HCP SPE enables the reversible cycling of an all-solid-state cell prepared with a high-voltage NMC 811 cathode. Our study opens up new possibilities for developing next-generation high-performance solid-state electrolytes.

25 ENERGY STORAGE↗

Transient current induced in thin film diamonds by swift heavy ions

Single crystal diamond is a suitable material for the next generation particle detectors because of the superior electrical properties and the high radiation tolerance. In order to investigate charge transport properties of diamond particle detectors, transient currents generated in diamonds by single swift heavy ions (26 MeV O 5 + and 45 MeV Si 7 + ) are investigated. We also measured two dimensional maps of transient currents by single ion hits. In the case of 50 μm-thick diamond, both the signal height and the collected charge are reduced by the subsequent ion hits and the charge collection time is extended. Our results are thought to be attributable to the polarization effect in diamond and it appears only when the transient current is dominated by hole current. In the case of 6 μm-thick diamond membrane, an “island” structure is found in the 2D map of transient currents. Signals in the islands shows different applied bias dependence from signals in other regions, indicating different crystal and/or metal contact quality. Simulation study of transient currents based on the Shockley-Ramo theorem clarifies that accumulation of space charges changes distribution of electric field in diamond and causes the polarization effect.

36 MATERIALS SCIENCE↗

Heavy ion action on single cells: Cellular inactivation capability of single accelerated heavy ions

Heavy ions (HZE-particles) constitute an important part of radiation in space. Although their number is small the high amount of energy transferred by individual particles may cause severe biological effects. Their investigation requires special techniques which were tested by experiments performed at the UNILAC at the GSI (Darmstadt). Diploid yeast was used which is a suitable eucaryotic test system because of its resistance to extreme conditions like dryness and vacuum. Cells were placed on nuclear track detector foils and exposed to ions of different atomic number and energy. To assess the action of one single ion on an individual cell, track parameters and the respective colony forming abilities (CFA) were determined with the help of computer aided image analysis. There is mounting evidence that not only the amount of energy deposited along the particle path, commonly given by the LET, is of importance but also the spatial problem of energy deposition at a submicroscopical scale. It is virtually impossible to investigate track structure effects in detail with whole cell populations and (globally applied) high particle fluences. It is, therefore, necessary to detect the action of simple ions in individual cells. The results show that the biological action depends on atomic number and specific energy of the impinging ions, which can be compared with model calculations of recent track structure models.

Kost, M.↗

On the hysteresis at ion extraction in the single-grid ion source

The ion extraction in the single-grid ion source with a woven extraction grid is researched. It has been found experimentally that the extraction can occur in ''low current'' and ''high current'' modes with stepwise hysteretic transitions between them. The assumption has been made that the existence of the two extraction regimes can be explained by the existence of two kinds of the space charge sheaths near the grid wires. This assumption is confirmed by the estimations of the sheath depth for the cylindrical and plane geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A singly charged ion source for radioactive {sup 11}C ion acceleration

A new singly charged ion source using electron impact ionization has been developed to realize an isotope separation on-line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive {sup 11}C ion beams. Low-energy electron beams are used in the electron impact ion source to produce singly charged ions. Ionization efficiency was calculated in order to decide the geometric parameters of the ion source and to determine the required electron emission current for obtaining high ionization efficiency. Based on these considerations, the singly charged ion source was designed and fabricated. In testing, the fabricated ion source was found to have favorable performance as a singly charged ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near- K -edge single, double, and triple photoionization of C + ions

Single, double, and triple ionization of the C + ion by a single photon have been investigated in the energy range 286 to 326 eV around the K-shell single-ionization threshold at an unprecedented level of detail. At energy resolutions as low as 12 meV, corresponding to a resolving power of 24 000, natural linewidths of the most prominent resonances could be determined. From the measurement of absolute cross sections, oscillator strengths, Einstein coefficients, multielectron Auger decay rates, and other transition parameters of the main K-shell excitation and decay processes are derived. The cross sections are compared to results of previous theoretical calculations. Mixed levels of agreement are found despite the relatively simple atomic structure of the C + ion with only five electrons. Finally, this paper is a followup to a previous Letter [A. Müller, Phys. Rev. Lett. 114, 013002 (2015)PRLTAO0031-900710.1103/PhysRevLett.114.013002].

74 ATOMIC AND MOLECULAR PHYSICS↗

Indistinguishable telecom band photons from a single Er ion in the solid state

Atomic defects in the solid state are a key component of quantum repeater networks for long-distance quantum communication1. Recently, there has been significant interest in rare earth ions, in particular Er 3+ for its telecom band optical transition that allows long-distance transmission in optical fibres. However, the development of repeater nodes based on rare earth ions has been hampered by optical spectral diffusion, precluding indistinguishable single-photon generation. Here, we implant Er 3+ into CaWO 4 , a material that combines a non-polar site symmetry, low decoherence from nuclear spins and is free of background rare earth ions, to realize significantly reduced optical spectral diffusion. For shallow implanted ions coupled to nanophotonic cavities with large Purcell factor, we observe single-scan optical linewidths of 150 kHz and long-term spectral diffusion of 63 kHz, both close to the Purcell-enhanced radiative linewidth of 21 kHz. This enables the observation of Hong–Ou–Mandel interference between successively emitted photons with a visibility of V = 80(4)%, measured after a 36 km delay line. We also observe spin relaxation times T 1,s = 3.7 s and T 2,s > 200 μs, with the latter limited by paramagnetic impurities in the crystal instead of nuclear spins. Furthermore, this represents a notable step towards the construction of telecom band quantum repeater networks with single Er 3+ ions.

42 ENGINEERING↗

Demonstration of Selective Single-Barium Ion Detection with Dry Diazacrown Ether Naphthalimide Turn-on Chemosensors

Single-molecule fluorescence imaging (SMFI) of gas-phase ions has been proposed for “barium tagging,” a burgeoning area of research in particle physics to detect individual barium daughter ions. This has potential to significantly enhance the sensitivity of searches for neutrinoless double-beta decay (0νββ) that is obscured by background radiation events. The chemistry required to make such sensitive detection of Ba 2+ by SMFI in dry Xe gas at solid interfaces has implications for solid-phase detection methods but has not been demonstrated. Here, we synthesized simple, robust, and effective Ba 2+ -selective chemosensors capable of function within ultrapure high-pressure 136 Xe gas. Turn-on fluorescent naphthalimide-(di)azacrown ether chemosensors were Ba 2+ -selective and achieved SMFI in a polyacrylamide matrix. Here, fluorescence and NMR experiments supported a photoinduced electron transfer mechanism for turn-on sensing. Ba 2+ selectivity was achieved with computational calculations correctly predicting the fluorescence responses of sensors to barium, mercury, and potassium ions. With these molecules, dry-phase single-Ba 2+ ion imaging with turn-on fluorescence was realized using an oil-free microscopy technique for the first time—a significant advance toward single-Ba 2+ ion detection within large volumes of 136 Xe, plausibly enabling a background-independent technique to search for the hypothetical process of 0νββ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Norbornene-Based Polymer Electrolytes for Lithium Cells

Norbornene-based polymers have shown promise as solid electrolytes for lithium-based rechargeable electrochemical cells. These polymers are characterized as single-ion conductors. Single-ion-conducting polymers that can be used in lithium cells have long been sought. Single-ion conductors are preferred to multiple-ion conductors as solid electrolytes because concentration gradients associated with multiple-ion conduction lead to concentration polarization. By minimizing concentration polarization, one can enhance charge and discharge rates. Norbornene sulfonic acid esters have been synthesized by a ring-opening metathesis polymerization technique, using ruthenium-based catalysts. The resulting polymer structures (see figure) include sulfonate ionomers attached to the backbones of the polymer molecules. These molecules are single-ion conductors in that they conduct mobile Li+ ions only; the SO3 anions in these polymers, being tethered to the backbones, do not contribute to ionic conduction. This molecular system is especially attractive in that it is highly amenable to modification through functionalization of the backbone or copolymerization with various monomers. Polymers of this type have been blended with poly(ethylene oxide) to lend mechanical integrity to free-standing films, and the films have been fabricated into solid polymer electrolytes. These electrolytes have been demonstrated to exhibit conductivity of 2 10(exp -5)S/cm (which is high, relative to the conductivities of other solid electrolytes) at ambient temperature, plus acceptably high stability. This type of norbornene-based polymeric solid electrolyte is in the early stages of development. Inasmuch as the method of synthesis of these polymers is inherently flexible and techniques for the fabrication of the polymers into solid electrolytes are amenable to optimization, there is reason to anticipate further improvements.

Cheung, Iris↗

Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

Here, a new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), and detected with a statistical significance of 12.9~$\sigma$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate Dose Control with Pressure Compensation System on Single-Wafer Ion Implanters

On ion implanters, dosimetry is generally controlled by monitoring an electrical current detected with Faraday cup(s) instead of the actual number of dopants. In some cases, ions in a beam undergo charge exchange phenomenon, interacting with residual gas molecules in a beamline. This charge exchange of ions causes variations of the detected beam currents which result in inaccurate dosimetry of implanted dopants. We will introduce to you a system similar to Pressure Compensation of the batch-type ion implanters to single-wafer ion implanters, that is, the SHX high current ion implanter and the MC3-II medium current ion implanter. The system converts the beam current detected with Faraday cups to an adequate value for dose control as a function of beamline pressure and brings accurate dosimetry also in these single-wafer ion implanters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-beam ion source enhanced growth of transparent conductive thin films

A single-beam ion source was developed and used in combination with magnetron sputtering to modulate the film microstructure. The ion source emits a single beam of ions that interact with the deposited film and simultaneously enhances the magnetron discharge. The magnetron voltage can be adjusted over a wide range, from approximately 240 to 130 V, as the voltage of the ion source varies from 0 to 150 V, while the magnetron current increases accordingly. The low-voltage high-current magnetron discharge enables a 'soft sputtering mode', which is beneficial for thin-film growth. Indium tin oxide (ITO) thin films were deposited at room temperature using a combined single-beam ion source and magnetron sputtering. Furthermore, the ion beam resulted in the formation of polycrystalline ITO thin films with significantly reduced resistivity and surface roughness. Single-beam ion-source-enhanced magnetron sputtering has many potential applications in which low-temperature growth of thin films is required, such as coatings for organic solar cells.

36 MATERIALS SCIENCE↗

Shock normal determination for multiple-ion shocks

We have adapted the single-ion Vinas and Scudder (1986) solution to the Rankine-Hugoniot (R-H) problem to a multiple-on solution. Using this technique, we can calculate a shock normal direction, shock speed, best estimate of the upstream and downstream magnetic field and plasma asymptotic states, and theta(sub Bn), the angle between the shock normal and the upstream magnetic field. We test the multi-ion solution with a theoretical case but are restricted to a perpendicular shock in order to close the multi-ion Rankine-Hugoniot equations. For this test case both single-ion and multi-ion solutions are equally valid. We examine parameter regimes to look for differences between single-ion and multi-ion solutions of the R-H equations, and we find that the largest differences occur for quasi-parallel shocks, small values of solar wind speed, large values of heavy ion density, and very strong and very weak shocks. For both the inbound and outbound crossing of comet Halley we have a slow solar wind speed, small values of water group ions and fairly weak shocks. We examine both the quasi-perpendicular inbound crossing and the quasi-parallel outbound crossing at comet Halley.

Kessel, R. L.↗