Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The differential Howland current source with high signal to noise ratio for bioimpedance measurement system

The stability and signal to noise ratio (SNR) of the current source circuit are the important factors contributing to enhance the accuracy and sensitivity in bioimpedance measurement system. In this paper we propose a new differential Howland topology current source and evaluate its output characters by simulation and actual measurement. The results include (1) the output current and impedance in high frequencies are stabilized after compensation methods. And the stability of output current in the differential current source circuit (DCSC) is 0.2%. (2) The output impedance of two current circuits below the frequency of 200 KHz is above 1 MΩ, and below 1 MHz the output impedance can arrive to 200 KΩ. Then in total the output impedance of the DCSC is higher than that of the Howland current source circuit (HCSC). (3) The SNR of the DCSC are 85.64 dB and 65 dB in the simulation and actual measurement with 10 KHz, which illustrates that the DCSC effectively eliminates the common mode interference. (4) The maximum load in the DCSC is twice as much as that of the HCSC. Lastly a two-dimensional phantom electrical impedance tomography is well reconstructed with the proposed HCSC. Therefore, the measured performance shows that the DCSC can significantly improve the output impedance, the stability, the maximum load, and the SNR of the measurement system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal Generator Compensates For Phase Shift In Cable

Stabilized reference signal delivered to remote unit. Signals at two different frequencies transmitted back and forth along cable and mixed to measure propagation delay in cable. Delay-measuring circuitry part of feedback loop constraining overall delay at stable value. Intended for use in system generating precise time and frequency signals, signal-generating subsystem compensates for phase shift in cable.

Sigman, E. H.↗

A Signal Transmission Technique for Stability Analysis of Multivariable Non-Linear Control Systems

Among the difficulties associated with multivariable, non-linear control systems is the problem of assessing closed-loop stability. Of particular interest is the class of non-linear systems controlled with on/off actuators, such as spacecraft thrusters or electrical relays. With such systems, standard describing function techniques are typically too conservative, and time-domain simulation analysis is prohibitively extensive, This paper presents an open-loop analysis technique for this class of non-linear systems. The technique is centered around an innovative use of multivariable signal transmission theory to quantify the plant response to worst case control commands. The technique has been applied to assess stability of thruster controlled flexible space structures. Examples are provided for Space Shuttle attitude control with attached flexible payloads.

Jackson, Mark↗

Analysis of the Effect of Communication Latencies on HVDC-Based Damping Control

A wide-area controller to damp inter-area oscillations in the North American Western Interconnection (WI) by modulating power transfers in a HVDC link is used in this paper to investigate the effects that latencies in its feedback signals have on its performance. This controller uses two feedback measurements to perform its control action. The analysis show that the stabilizing effect of the controller in transient stability and small signal stability is compromised as the feedback measurements experience higher delays. The results show that one of the feedback signals can tolerate more delay than the other. The analysis was performed with Bode plots and time domain simulations on a reduced order model of the WI from which a linear version was obtained.

Wilches-Bernal, Felipe↗

Actively stabilized optical fiber interferometry technique for online/in-process surface measurement

In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the role of exchange of power and information signals in control and stability of the human-robot interaction

A human's ability to perform physical tasks is limited, not only by his intelligence, but by his physical strength. If, in an appropriate environment, a machine's mechanical power is closely integrated with a human arm's mechanical power under the control of the human intellect, the resulting system will be superior to a loosely integrated combination of a human and a fully automated robot. Therefore, we must develop a fundamental solution to the problem of 'extending' human mechanical power. The work presented here defines 'extenders' as a class of robot manipulators worn by humans to increase human mechanical strength, while the wearer's intellect remains the central control system for manipulating the extender. The human, in physical contact with the extender, exchanges power and information signals with the extender. The aim is to determine the fundamental building blocks of an intelligent controller, a controller which allows interaction between humans and a broad class of computer-controlled machines via simultaneous exchange of both power and information signals. The prevalent trend in automation has been to physically separate the human from the machine so the human must always send information signals via an intermediary device (e.g., joystick, pushbutton, light switch). Extenders, however are perfect examples of self-powered machines that are built and controlled for the optimal exchange of power and information signals with humans. The human wearing the extender is in physical contact with the machine, so power transfer is unavoidable and information signals from the human help to control the machine. Commands are transferred to the extender via the contact forces and the EMG signals between the wearer and the extender. The extender augments human motor ability without accepting any explicit commands: it accepts the EMG signals and the contact force between the person's arm and the extender, and the extender 'translates' them into a desired position. In this unique configuration, mechanical power transfer between the human and the extender occurs because the human is pushing against the extender. The extender transfers to the human's hand, in feedback fashion, a scaled-down version of the actual external load which the extender is manipulating. This natural feedback force on the human's hand allows him to 'feel' a modified version of the external forces on the extender. The information signals from the human (e.g., EMG signals) to the computer reflect human cognitive ability, and the power transfer between the human and the machine (e.g., physical interaction) reflects human physical ability. Thus the information transfer to the machine augments cognitive ability, and the power transfer augments motor ability. These two actions are coupled through the human cognitive/motor dynamic behavior. The goal is to derive the control rules for a class of computer-controlled machines that augment human physical and cognitive abilities in certain manipulative tasks.

Kazerooni, H.↗

Synchronization in networks of spatially extended systems

Synchronization processes in networks of spatially extended dynamical systems are analytically and numerically studied. We focus on the relevant case of networks whose elements (or nodes) are spatially extended dynamical systems, with the nodes being connected with each other by scalar signals. The stability of the synchronous spatio-temporal state for a generic network is analytically assessed by means of an extension of the master stability function approach. We find an excellent agreement between the theoretical predictions and the data obtained by means of numerical calculations. The efficiency and reliability of this method is illustrated numerically with networks of beam-plasma chaotic systems (Pierce diodes). We discuss also how the revealed regularities are expected to take place in other relevant physical and biological circumstances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of Joule Heating on the Stability of High Temperature Irradiation Resistant Thermocouples

Development of in-core instrumentation is driven by the pursuit of safer and more economic energy production from both existing nuclear reactors and Generation IV reactor designs. Idaho National Laboratory (INL) has developed high temperature irradiation resistant thermocouples (HTIR-TCs) for temperature sensing inside Generation IV nuclear reactors. These thermocouples are composed of phosphorus-doped niobium (Nb-P) and lanthana-doped molybdenum (Mo-LaO) thermoelements, an alumina (Al2O3) insulation, and a niobium sheath. HTIR-TCs require an initial heat treatment exceeding the maximum service temperature to stabilize the generated electromotive force (EMF) signal; however, the mechanism behind this stabilization is not well understood. This work evaluates the impact of Joule heating on the thermoelements' microstructures, chemical stability, and mechanical properties to determine the mechanisms by which the EMF signal stabilization occurs. Accordingly, during the Joule heat treatment, a secondary Nb3P phase coarsened along the length of the Nb-P thermoelement, along with the formation of an interaction region at the Al2O3/niobium interface. The interaction between the alumina insulation and the Nb-P thermoelement was also observed within the Mo-LaO thermoelement. Joule heating induced stability within the generated EMF signal of HTIR-TCs through the formation of secondary phases within the Nb-P and the interaction of the alumina insulation with the thermoelements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Automatic signal decoding and sensor stability of a 3-electrode mixed-potential sensor for NO x /NH 3 quantification

Sensors to detect mixtures of NO x /NH 3 are needed to monitor emissions of diesel automobiles where a selective catalytic reduction system uses an NH 3 mediated reaction to reduce NO x . We report on the application of a three electrode La 0.8 Sr 0.2 CrO 3 , Au 0.5 Pd 0.5 , Pt mixed potential sensor using yttria-stabilized-zirconia (YSZ) as a solid electrolyte to NO x /NH 3 sensing. Artificial neural networks were used to automatically decode the concentrations of NO x /NH 3 and errors of less than 15% are achieved. The optimal architecture for ANN decoding and the maximum density of training data points are also determined. The stability of the sensor was monitored by electrochemical impedance spectroscopy. The impedance associated with YSZ oxygen ion conduction and the electrochemical reactions at the three-phase interface are tracked for a period of over 100 days.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary analysis of amplitude and phase fluctuations in the JAPE multiple tone data to distances of 500 meters

The JAPE short range data provide a good opportunity for studying phase and amplitude fluctuations of acoustic signals in the atmosphere over distances of several hundred meters. Several factors contribute to the usefulness of these data: extensive meteorological measurements were made, controlled sources were used, the data were recorded with a high dynamic range digital system that preserved phase information and a significant number of measurement points were obtained allowing both longitudinal and transverse studies. Further, Michigan Tech, in cooperation with the U.S. Army TARDEC, has developed phase tracking algorithms for studying vehicle acoustic signals. These techniques provide an excellent tool for analyzing the amplitude and phase fluctuations of the JAPE data. The results of studies such as those reported here have application at several levels: the mechanisms of signal amplitude and phase fluctuations in propagating acoustic signals are not well understood nor are the mathematical models highly developed, acoustic arrays depend strongly on signal coherence and signal amplitude stability in order to perform to their design specifications and active noise control implementation in regions considerably removed from the primary and secondary sources depends upon signal amplitude and phase stability. Work reported here is preliminary in nature but it does indicate the utility of the phase tracking and amplitude detection algorithms. The results obtained indicate that the phase fluctuations of the JAPE continuous multiple tone data (simultaneous transmission of 80, 200 and 500 Hz) are in general agreement with existing theories but the amplitude fluctuations are seen to be less well behaved and show less consistency.

Rogers, James↗

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laser frequency stabilization to excited state transitions using electromagnetically induced transparency in a cascade system

We demonstrate laser frequency stabilization to excited state transitions using cascade electromagnetically induced transparency. Using a room temperature Rb vapor cell as a reference, we stabilize a first diode laser to the D{sub 2} transition and a second laser to a transition from the intermediate 5P{sub 3/2} state to a highly excited state with principal quantum number n=19-70. A combined laser linewidth of 280{+-}50 kHz over a 100 {mu}s time period is achieved. This method may be applied generally to any cascade system and allows laser stabilization to an atomic reference in the absence of a direct absorption signal.

74 ATOMIC AND MOLECULAR PHYSICS↗

Note: Directly measuring the direct digital synthesizer frequency chirp-rate for an atom interferometer

During gravity measurements with Raman type atom interferometry, the frequency of the laser used to drive Raman transition is scanned by chirping the frequency of a direct digital synthesizer (DDS), and the local gravity is determined by precisely measuring the chip rate α of DDS. We present an effective method that can directly evaluate the frequency chirp rate stability of our DDS. By mixing a pair of synchronous linear sweeping signals, the chirp rate fluctuation is precisely measured with a frequency counter. The measurement result shows that the relative α instability can reach 5.7 × 10{sup −11} in 1 s, which is neglectable in a 10{sup −9} g level atom interferometry gravimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗