Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCRUBBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Amine Oxidation Catalyzed by NO 2

Amine oxidation is a major risk in the deployment of amine scrubbing for CO2 capture from post-combustion flue gas. Oxidation probably occurs by dissolved oxygen at elevated temperature, Fe(III)/Fe(II) shuttling between the absorber and the stripper, and by NO2 in the absorber. Amine selection, dissolved oxygen removal, and solvent reclaiming mitigate oxidation due to dissolved oxygen and iron shuttle mechanism, but not by NO2. This work examines piperazine (PZ) oxidation by NO2 in a bench-scale high gas flow reactor (HGF). PZ is an effective second-generation solvent with high CO2 capacity, fast capture rate, good thermal stability, and good resistance to oxidation. Flue gas typically contains 0.5–5 ppm NO2 and 10–100 ppm NO. NO2 at 1 ppm in the flue gas appears to cause significant amine oxidation in pilot plant testing. PZ solution can easily absorb NO2, and it is hypothesized that NO2 can catalytically oxidize PZ through free-radical propagation. The issue may not be solved by a NO2 pre-scrubber since the coexistence of NO and O2 in the flue gas will keep producing non-negligible amounts of NO2 in the ductwork and the absorber after the NO2 incoming with the flue gas has been scrubbed. In addition, NO2 may not only oxidize PZ but also the intermediate degradation products, and it is unknown if the existence of dissolved iron influences the oxidation by NO2. Previous workers have also shown that NO2 is the stoichiometric source of nitrosamine. A comprehensive analysis of NO2 oxidation is needed to address solvent management and its health/environmental impact. The new high gas flow (HGF) reactor focuses only on the absorber environment and is simpler to interpret because it does not include oxidation at high temperatures and by dissolved metal catalysts from corrosion. This paper presents the results of HGF experiments and shows evidence to support a hypothesis of amine oxidation catalyzed by NO2, presents the synergic effect of NO2 and iron on amine oxidation, points out the different effects of NO2 in clean and degraded solvents, and demonstrates that NO2 not only can oxidize amines but also their degradation products.

NO2, iron, piperazine (PZ), solvent oxidation, sol↗

SOLVENT HOLD TANK SAMPLE RESULTS FOR MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 AND MCU-11-319

Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 and MCU-11-319 are reported. The results show that the solvent at MCU does not require an Isopar{reg_sign} L addition, but it will require addition of trioctylamine. Cesium mass transfer testing with the solvent matches expected extraction behavior but shows a slightly lower stripping efficiency than seen in the original process demonstration for Macrobatch 3. The entrained aqueous solution indicates the scrub wash is significantly out of specification. As a result, the facility replaced the scrub wash. Unlike the previous solvent sample results, these analyses indicate that the solvent does not require minor Isopar{reg_sign} L trimming at this time. However, addition of TOA is warranted. These findings indicate that the new protocols for solvent monitoring and control are yielding favorable results. Nevertheless, the deviation in the TOA concentration since the last analysis indicates continued periodic (i.e., quarterly) monitoring is recommended. The {sup 137}Cs mass transfer results from the solvent sample testing show possible evidence of slightly reduced stripping efficiency. An evaluation (using a model) of expected system performance for MCU using the measured distribution values predicts an {approx}50% decline in DFs given the ESS test results. The customer should consider pulling a SHT sample for reanalysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sample Results from the Integrated Salt Disposition Program Macrobatch 5 Tank 21H Qualification MST, ESS and PODD Samples

Savannah River National Laboratory (SRNL) performed experiments on qualification material for use in the Integrated Salt Disposition Program (ISDP) Batch 5 processing. This qualification material was a composite created from recent samples from Tank 21H and archived samples from Tank 49H to match the projected blend from these two tanks. Additionally, samples of the composite were used in the Actinide Removal Process (ARP) and extraction-scrub-strip (ESS) tests. ARP and ESS test results met expectations. A sample from Tank 21H was also analyzed for the Performance Objectives Demonstration Document (PODD) requirements. SRNL was able to meet all of the requirements, including the desired detection limits for all the PODD analytes. This report details the results of the Actinide Removal Process (ARP), Extraction-Scrub-Strip (ESS) and Performance Objectives Demonstration Document (PODD) samples of Macrobatch (Salt Batch) 5 of the Integrated Salt Disposition Program (ISDP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of the impact of glycolate on arp and mcu operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5,000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5,000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similarly to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. In addition to the MST and mMST testing, testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5,000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests. (A single data point in the 5,000 ppm test is physically impossible and SRNL is currently resolving this obvious error.) At this time, SRNL concludes that the presence of up to 10,000 ppm of glycolate does not affect cesium removal by the current solvent system used in the MCU. Although not tested, the impact of glycolate for the Next Generation Solvent - that replaces BOBCalixC6 with MaxCalix - is expected to be very similar to that for the baseline solvent. Testing is needed to confirm. Additional testing is recommended to both further examine the nature of the interaction of glycolate with MST and mMST and also to help address some postulated risks on ARP/MCU operations with implementation of the glycolate flowsheet. The additional testing includes FTIR and Raman spectroscopy to examine the surface of the MST and mMST particles, iodometric titrations to determine the peroxide content in the mMST before and after exposure to glycolate, particle size measurements of the MST and mMST from the experiments performed with glycolate, and measurements of soluble Ti in the supernate from these glycolate experiments. With regards to MCU impacts, the following tests are also recommended based on the premortem risk assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of the Impact of Glycolate on ARP and MCU Operations

Savannah River Remediation (SRR) is evaluating an alternate flowsheet for the Defense Waste Processing Facility (DWPF) using glycolic acid as a reductant. An important aspect of the development of the glycolic acid flowsheet is determining if glycolate has any detrimental downstream impacts. Testing was performed to determine if there is any impact to the strontium and actinide sorption by monosodium titanate (MST) and modified monosodium titanate (mMST) or if there is an impact to the cesium removal, phase separation, or coalescer performance at the Modular Caustic-Side Solvent Extraction Processing Unit (MCU). Sorption testing was performed using both MST and modified MST (mMST) in the presence of 5000 and 10,000 ppm (mass basis) glycolate. 10,000 ppm is the estimated bounding concentration expected in the DWPF recycle stream based on DWPF melter flammable gas model results. The presence of glycolate was found to slow the removal of Sr and Pu by MST, while increasing the removal rate of Np. Results indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. There was no measurable effect on U removal at either glycolate concentration. The slower removal rates for Sr and Pu at 5000 and 10,000 ppm glycolate could result in lower DF values for these sorbates in ARP based on the current (12 hours) and proposed (8 hours) contact times. For the highest glycolate concentration used in this study, the percentage of Sr removed at 6 hours of contact decreased by 1% and the percentage of Pu removed decreased by nearly 7%. The impact may prove insignificant if the concentration of glycolate that is returned to the tank farm is well below the concentrations tested in this study. The presence of glycolate also decreased the removal rates for all three sorbates (Sr, Pu, and Np) by mMST. Similar to MST, the results for mMST indicate that the impact is a kinetic effect, and the overall capacity of the material is not affected. The presence of glycolate did not change the lack of affinity of mMST for U. Pre-contacting the MST or mMST with glycolate did not have a significant effect on the performance of the materials when compared to tests having the same concentration of glycolate present in the simulant. These findings suggest that the glycolate is likely influencing removal by sorbate complexation and not by depositing onto or forming a film on the surface of the MST solids. Since the DF values are salt batch dependent, it is not possible to a priori quantify the impacts of glycolate on future processing campaigns. However, we recommend that the impacts of glycolate be evaluated during each salt batch qualification when a final processing concentration is defined, and recommendations can then be made on how to mitigate negative impacts, if needed. Impacts to the performance of the MST or mMST could be mitigated by increasing contact time or increasing sorbent concentrations. Testing was performed to determine if there is an impact to the cesium removal at Modular Caustic-Side Solvent Extraction Processing Unit (MCU). An Extraction-Scrub-Strip (ESS) test routine was used to simulate cesium removal at the MCU. For this, SRNL performed three ESS tests, using the same basic aqueous waste simulant and solvent. For one test, SRNL added 5000 ppm (mass basis) of glycolate and added 10,000 ppm of glycolate to a second test. A control test contained no glycolate. The results of all three tests were virtually identical for all the extraction, scrub and strip tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Testing Options for the NTR at the INL (Final Report)

One of the main technologies that can be developed to dramatically enhance the human exploration of space is the nuclear thermal rocket (NTR). Several studies over the past thirty years have shown that the NTR can reduce the cost of a lunar outpost, reduce the risk of a human mission to Mars, enable fast transits for most missions throughout the solar system, and reduce the cost and time for robotic probes to deep space. Three separate committees of the National Research Council of the National Academy of Sciences have recommended that NASA develop the NTR. One of the primary issues in development of the NTR is the ability to verify a flight ready unit. Three main methods can be used to validate safe operation of a NTR: 1) Full power, full duration test in an above ground facility that scrubs the rocket exhaust clean of any fission products; 2) Full power , full duration test using the Subsurface Active Filtering of Exhaust (SAFE) technique to capture the exhaust in subsurface strata; 3) Test of the reactor fuel at temperature and power density in a driver reactor with subsequent first test of the fully integrated NTR in space. The first method, the above ground facility, has been studied in the past. The second method, SAFE, has been examined for application at the Nevada Test Site. The third method relies on the fact that the Nuclear Furnace series of tests in 1971 showed that the radioactive exhaust coming from graphite based fuel for the NTR could be completely scrubbed of fission products and the clean hydrogen flared into the atmosphere. Under funding from the MSFC, the Center for Space Nuclear Research (CSNR) at the Idaho National laboratory (INL) has completed a reexamination of Methods 2 and 3 for implementation at the INL site. In short, the effort performed the following: 1) Assess the geology of the INL site and determine a location suitable SAFE testing; 2) Perform calculations of gas transport throughout the geology; 3) Produce a cost estimate of a non-nuclear , sub-scale test using gas injection to validate the computational models; 4) Produce a preliminary cost estimate to build a nuclear furnace equivalent facility to test NTR fuel on a green field location on the INL site. The results show that the INL geology is substantially better suited to the SAFE testing method than the NTS site. The existence of impermeable interbeds just above the sub-surface aquifer ensure that no material from the test, radioactive or not, can enter the water table. Similar beds located just below the surface will prevent any gaseous products from reaching the surface for dispersion. The extremely high permeability of the strata between the interbeds allows rapid dispersion of the rocket exhaust. In addition, the high permeability suggests that a lower back-pressure may develop in the hole against the rocket thrust, which increases safety of operations. Finally, the cost of performing a sub-scale, non-nuclear verification experiment was determined to be $\$$3M. The third method was assessed through discussions with INL staff resident at the site. In essence, any new Category I facility on any DOE site will cost in excess of $\$$250M. Based on the results of this study, a cost estimate for testing a nuclear rocket at the INL site appears to be warranted. Given the fact that a new nuclear fuel may be possible that does not release any fission products, the SAFE testing option appears to be the most affordable.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimized Solvent for Energy-Efficient, Environmentally-Friendly Capture of CO{sub 2} at Coal-Fired Power Plants

The overall goal of this project, as originally proposed, was to optimize the formulation of a novel solvent as a critical enabler for the cost-effective, energy-efficient, environmentally-friendly capture of CO{sub 2} at coal-fired utility plants. Aqueous blends of concentrated piperazine (PZ) with other compounds had been shown to exhibit high rates of CO{sub 2} absorption, low regeneration energy, and other desirable performance characteristics during an earlier 5-year development program conducted by B&W. The specific objective of this project was to identify PZ-based solvent formulations that globally optimize the performance of coal-fired power plants equipped with CO{sub 2} scrubbing systems. While previous solvent development studies have tended to focus on energy consumption and absorber size, important issues to be sure, the current work seeks to explore, understand, and optimize solvent formulation across the full gamut of issues related to commercial application of the technology: capital and operating costs, operability, reliability, environmental, health and safety (EH&S), etc. Work on the project was intended to be performed under four budget periods. The objective of the work in the first budget period has been to identify several candidate formulations of a concentrated PZ-based solvent for detailed characterization and evaluation. Work in the second budget period would generate reliable and comprehensive property and performance data for the identified formulations. Work in the third budget period would quantify the expected performance of the selected formulations in a commercial CO{sub 2} scrubbing process. Finally, work in the fourth budget period would provide a final technology feasibility study and a preliminary technology EH&S assessment. Due to other business priorities, however, B&W has requested that this project be terminated at the end of the first budget period. This document therefore serves as the final report for this project. It is the first volume of the two-volume final report and summarizes Budget Period 1 accomplishments under Tasks 1-5 of the project, including the selection of four solvent formulations for further study.

20 FOSSIL-FUELED POWER PLANTS↗

Sample Results from MCU Solids Outage

Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate; An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or additional details are provided below as recommendations. From this point on, IC-Anions analyses of the DSSHT should be part of the monthly routine analysis in order to spot negative trends in the oxalate leaving the MCU system. Care must be taken to monitor the oxalate content to watch for sudden precipitation of oxalate salts in the system; Conduct a study to optimize the cleaning strategy at ARP-MCU through decreasing the concentration or entirely eliminating the oxalic acid; The contents of the SSFT should remain unagitated. Routine visual observation should be maintained to ensure there is not a large buildup of solids. As water with agitation provided sufficient removal of the solids in the feed tank, it should be considered as a good means for dissolving oxalate solids if they are found in the future; Conduct a study to improve prediction of oxalate solubility in salt batch feed materials. As titanium and mercury have been found in various solids in this report, evaluate if either element plays a role in oxalate solubility during processing; Salt batch characterization focuses primarily on characterization and testing of unaltered Tank 21H material; however, non-typical feeds are developed through cleaning, washing, and/or sump transfers. As these solutions are processed through MCU, they may precipitate solids or reduce performance. Salt batch characterization and testing should be expanded to encompass a broader range of feeds that may be processed through ARPMCU.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Assessment of Ruthenium Removal Systems for Tritium Pretreatment Off-Gas

The processing of used nuclear fuel releases volatile and semivolatile radionuclides into the off-gas streams associated with the various processing steps. Ongoing efforts to develop methods to control the release of gaseous radionuclides to the environment have identified ruthenium (specifically 106 Ru) as one of the semivolatile nuclides requiring a high degree of abatement. The tritium pretreatment process will release a fraction of the ruthenium as volatile ruthenium tetroxide (RuO 4 ). Scoping tests were conducted to characterize the adsorption/deposition of RuO 4 from dry gas streams by two different substrates: steel wool and silica gel. A simple test system was assembled to produce RuO 4 through oxidation of powdered ruthenium metal, followed by a temperature-controlled sorption column. Tests were conducted with no sorbent present in the column to obtain baseline data on the evolution of RuO 4 and deposition of ruthenium on the internal surfaces of the column. Silica gel and steel wool were tested as adsorbent media. Gaseous effluent from the column was scrubbed with caustic solution to remove any remaining ruthenium. Ultraviolet/visible spectroscopy (UV/Vis) and inductively coupled plasma–mass spectroscopy analyses were used to measure the amount of ruthenium in the scrub solutions. The UV/Vis analysis proved to be problematic because of precipitation of ruthenates, ruthenium oxides, and hydrated ruthenium oxides that occurred over time. An effective stabilization agent that does not adversely affect the desired spectra needs to be identified if this method is to be used in the future. There were indications that oxidation of powdered ruthenium metal did not generate a stream with steady concentration of RuO 4 , so improved techniques are needed for follow-on experiments designed to infer deposition rate. Both steel wool and silica gel are able to decrease the effluent Ru concentration by a factor of 10–100 during the 5-hour tests conducted. These tests were conducted using a dilute RuO 4 -bearing dry gas stream and the short test duration did not result in sorbent saturation or in an estimation of Ru breakthrough time. RuO 4 desorbs from silica gel at room temperature. As interactions between RuO 4 and silica gel are not irreversible, it cannot function as a disposal media without pretreatment to reduce RuO 4 to a less mobile species. Silica gel may be useful as a RuO 4 sorbent or delay media in some applications. Based on visual observations, steel wool was an effective deposition substrate with no evidence of RuO 4 release. The deposition form should be identified and methods to assay the ruthenium content need to be developed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PNNL Report on the Development of Bench-scale CFD Simulations for Gas Absorption across a Wetted Wall Column

This report is prepared for the demonstration of hierarchical prediction of carbon capture efficiency of a solvent-based absorption column. A computational fluid dynamics (CFD) model is first developed to simulate the core phenomena of solvent-based carbon capture, i.e., the CO 2 physical absorption and chemical reaction, on a simplified geometry of wetted wall column (WWC) at bench scale. Aqueous solutions of ethanolamine (MEA) are commonly selected as a CO 2 stream scrubbing liquid. CO 2 is captured by both physical and chemical absorption using highly CO 2 soluble and reactive solvent, MEA, during the scrubbing process. In order to provide confidence bound on the computational predictions of this complex engineering system, a hierarchical calibration and validation framework is proposed. The overall goal of this effort is to provide a mechanism-based predictive framework with confidence bound for overall mass transfer coefficient of the wetted wall column (WWC) with statistical analyses of the corresponding WWC experiments with increasing physical complexity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cheesecloth Alternatives Testing

Heat source plutonium oxide (HS-PuO 2 ) enriched with 65% or greater plutonium-238, is recovered and purified using an aqueous nitric acid process. Historically, cheesecloth has been employed for small spill clean-up and for routine housekeeping. However, the 2016 Department of Energy (DOE) Operating Experience report, entitled Nitrate Waste Evaluations, stated that the mixing of nitrate wastes with organic absorbents, such as cheesecloth, may render transuranic waste unacceptable for disposal at WIPP in the future. This report explores the feasibility of replacement of cheesecloth with an alternative sorbent wipe that has similar absorption and cleaning abilities and improved acid resistance. Currently, cheesecloth is used for three different functions in HS-PuO 2 operations: spill cleanup; general housekeeping operations such as cleaning glovebox floors and windows, balances, furnaces, etc.; and decontamination of iridium cladded heat sources containing HS-PuO 2 . Alternatives used for spill cleanup must be able to tolerate high neutron doses found in the HS-Pu gloveboxes. They must also be able to withstand exposure to nitric acid concentrations up to 15.8 M without decomposing. Wipes used for general housekeeping must also be durable enough to clean rough surfaces and remain intact when used for scrubbing. Wipes used for clad decontamination do not need to absorb large amounts of liquid but they must be able to withstand neutron exposures, temperatures of up to several hundred degrees Celsius, and exposure to acid solutions followed by mild scrubbing. Finally wipes used for any purpose must resist chemical reactions with nitric acid that could cause issues for waste disposal such as energetic exothermic reactions or flammable gas build-up. The wipes selected for this study were ranked based on their usability (radiation tolerance, absorbency, integrity in nitric acid, and durability) as well as their chemical compatibility with nitric acid as demonstrated using several types of chemical analyses. Wipes were then ranked based on the combination of their usability and chemical compatibility scores.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon Capture via Crystallization with a Guanidine Ligand

Carbon capture and storage (CCS) is an important strategy aimed at stabilizing the atmospheric CO2 concentration and thereby the global temperature. In conventional fossil fuel-fired power plants, the resulting flue gas is released into the air without any carbon dioxide scrubbing, which gradually increases the atmospheric CO 2 concentration (currently at approximately 409 ppm). Implementation of post-combustion capture (PCC) of carbon dioxide, whereby the CO 2 emitted by power plants is captured and stored into geological repositories, would enable us to continue to use relatively cheap fossil fuels such as coal, natural gas, and oil, but with significantly reduced CO 2 emissions. A recent report by the International Energy Agency indicated that by 2050 CCS could reduce the annual CO 2 emissions by almost 6 gigatones, which represents about 14% of the total carbon emission reduction necessary to limit the global temperature increase by 2 ºC by the end of the 21st century (International Energy Agency, 2016). This goal will be accomplished by developing inexpensive materials that can be used to effectively capture CO 2 and be regenerated with minimal energy penalty. This project helped address this need by introducing new materials and mechanisms for CO 2 capture. The goal of this project was to demonstrate a bench-scale CO 2 capture process based on a novel guanidinium (bi)carbonate crystallization approach, and ultimately develop an energy-efficient and cost-effective technology for CO 2 capture from flue gas. The project built on our recent discovery of a new class of aqueous guanidine sorbents that react with carbon dioxide and crystallize as carbonate or bicarbonate salts of very low aqueous solubility (Brethomé, 2018; Williams, 2019). The resulting guanidinium (bi)carbonate crystals release the CO 2 upon mild heating at 80-120 ºC, which regenerates the guanidine ligands quantitatively (Figure 1). The potential advantage of this crystallization-based approach over traditional amine scrubbing methods (i.e., using aqueous MEA) is that it allows sorbent regeneration by heating the solid crystals alone, without the bulk solution, making this process more energy-efficient.

20 FOSSIL-FUELED POWER PLANTS↗

Dissolver Off-gas Hot Operations Authorization (AFCI CETE Milestone Report)

The head-end processing of the Coupled-End-to-End (CETE) Demonstration includes fuel receipt, fuel disassembly, exposure of fuel (e.g., by segmenting the fuel pins), voloxidation of the fuel to separate tritium, and fuel dissolution. All of these processing steps with the exception of the dissolution step will be accomplished in the Irradiated Fuels Examination Laboratory (IFEL) (Building 3525). The final headend step will be performed in the Radiochemical Engineering Development Center (Building 7920). The primary purpose of the fuel dissolution step is to prepare the solid fuel for subsequent liquid separations steps. This is accomplished by dissolving the fuel solids using nitric acid. During the dissolution process gases are evolved. Oxides of nitrogen are the primary off-gas components generated by the reactions of nitric acid and the fuel oxides however, during the dissolution and sparging of the resulting solution, iodine, C-14 as carbon dioxide, xenon, and krypton gasses are also released to the off-gas stream. The Dissolver Off-gas treatment rack provides a means of trapping these volatile fission products and other gases via various trapping media. Specifically the rack will recover iodine on a solid sorbent bed, scrub NOx in a water/acid column, scrub CO{sub 2} in a caustic scrubber column, remove moisture with solid sorbent drier beds and recover Xe and Kr using solid absorbent beds. The primary purpose of this experimental rack and the off-gas rack associated with the voloxidation equipment located at IFEL is to close the material balances around the volatile gases and to provide an understanding of the impacts of specific processing conditions on the fractions of the volatile components released from the various head-end processing steps.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Global 10 m Land Use Land Cover Datasets: A Comparison of Dynamic World, World Cover and Esri Land Cover

The European Space Agency’s Sentinel satellites have laid the foundation for global land use land cover (LULC) mapping with unprecedented detail at 10 m resolution. We present a cross-comparison and accuracy assessment of Google’s Dynamic World (DW), ESA’s World Cover (WC) and Esri’s Land Cover (Esri) products for the first time in order to inform the adoption and application of these maps going forward. For the year 2020, the three global LULC maps show strong spatial correspondence (i.e., near-equal area estimates) for water, built area, trees and crop LULC classes. However, relative to one another, WC is biased towards over-estimating grass cover, Esri towards shrub and scrub cover and DW towards snow and ice. Using global ground truth data with a minimum mapping unit of 250 m 2 , we found that Esri had the highest overall accuracy (75%) compared to DW (72%) and WC (65%). Across all global maps, water was the most accurately mapped class (92%), followed by built area (83%), tree cover (81%) and crops (78%), particularly in biomes characterized by temperate and boreal forests. The classes with the lowest accuracies, particularly in the tundra biome, included shrub and scrub (47%), grass (34%), bare ground (57%) and flooded vegetation (53%). When using European ground truth data from LUCAS (Land Use/Cover Area Frame Survey) with a minimum mapping unit of <100 m 2 , we found that WC had the highest accuracy (71%) compared to DW (66%) and Esri (63%), highlighting the ability of WC to resolve landscape elements with more detail compared to DW and Esri. Although not analyzed in our study, we discuss the relative advantages of DW due to its frequent and near real-time data delivery of both categorical predictions and class probability scores. We recommend that the use of global LULC products should involve critical evaluation of their suitability with respect to the application purpose, such as aggregate changes in ecosystem accounting versus site-specific change detection in monitoring, considering trade-offs between thematic resolution, global versus. local accuracy, class-specific biases and whether change analysis is necessary. We also emphasize the importance of not estimating areas from pixel-counting alone but adopting best practices in design-based inference and area estimation that quantify uncertainty for a given study area.

54 ENVIRONMENTAL SCIENCES↗

Considerations for the Use of STEREO -HI Data for Astronomical Studies

Recent refinements to the photometric calibrations of the Heliospheric Imagers (HI) on board the Solar TErrestrial RElations Observatory ( STEREO ) have revealed a number of subtle effects in the measurement of stellar signals with those instruments. These effects need to be considered in the interpretation of STEREO -HI data for astronomy. In this paper we present an analysis of these effects and how to compensate for them when using STEREO -HI data for astronomical studies. We determine how saturation of the HI CCD detectors affects the apparent count rates of stars after the on-board summing of pixels and exposures. Single-exposure calibration images are analyzed and compared with binned and summed science images to determine the influence of saturation on the science images. We also analyze how the on-board cosmic-ray scrubbing algorithm affects stellar images. We determine how this interacts with the variations of instrument pointing to affect measurements of stars. We find that saturation is a significant effect only for the brightest stars, and that its onset is gradual. We also find that degraded pointing stability, whether of the entire spacecraft or of the imagers, leads to reduced stellar count rates and also increased variation thereof through interaction with the on-board cosmic-ray scrubbing algorithm. We suggest ways in which these effects can be mitigated for astronomical studies and also suggest how the situation can be improved for future imagers.

79 ASTRONOMY AND ASTROPHYSICS↗

Nitrogen tetroxide scrubber data analysis

A major difficulty in the analysis of scrubber data is that of separating the physical effects, such as mass transfer, from the physico-chemical effects, such as reaction rates. This is especially true for the absorbtion of nitrogen tetroxide in the various liquids that were tested in the NASA-Kennedy Space Center Hypergolic Toxic Scrubber Program. A fruitful approach to correlating the data for outlet concentrations was to treat the overall absorbtion as a pseudo first-order absorbtion equation. This approach provided a method for normalizing the data to constant inlet concentration, constant sump liquor condition, and constant scrubbing time, and permitted evaluation of the test and fluid parameters that affected both absorbtion rate and scrubbing time. The analysis indicated that scrubber performance may be improved by optimizing liquor concentrations and liquor flowrate distributions.

Simon, E. D.↗

Improved aqueous scrubber for collection of soluble atmospheric trace gases

A new concentration technique for the extraction and enrichment of water-soluble atmospheric trace gases has been developed. The gas scrubbing technique efficiently extracts soluble gases from a large volume flow rate of air sample into a small volume of refluxed trapping solution. The gas scrubber utilizes a small nebulizing nozzle that mixes the incoming air with an aqueous extracting solution to form an air/droplet mist. The mist provides excellent interfacial surface areas for mass transfer. The resulting mist sprays upward through the reaction chamber until it impinges upon a hydrophobic membrane that virtually blocks the passage of droplets but offers little resistance to the existing gas flow. Droplets containing the scrubbed gases coalesce on the membrane and drip back into the reservoir for further refluxing. After a suitable concentration period, the extracting solution containing the analyte can be withdrawn for analysis. The nebulization-reflex concentration technique is more efficient (maximum flow of gas through the minimum volume of extractant) than conventional bubbler/impinger gas extraction techniques and is offered as an alternative method.

Cofer, W. R., III↗

Nebulization reflux concentrator

A nebulization reflux concentrator for removing trace gas contaminants from a sample gas is described. Sample gas from a gas supply is drawn by a suction source into a vessel. The gas enters the vessel through an atomizing nozzle, thereby atomizing and entraining a scrubbing liquid solvent drawn through a siphon tube from a scrubbing liquid reservoir. The gas and entrained liquid rise through a concentrator and impinge upon a solvent phobic filter, whereby purified gas exits through the filter housing and contaminated liquid coalesces on the solvent phobic filter and falls into the reservoir.

Collins, V. G.↗