A monolayer microfluidic device supporting mouse spermatogenesis with improved visibility

In our previous study, we produced a microfluidic device (MFD) which successfully maintained spermatogenesis for over 6 months in mouse testis tissues loaded in the device. In the present study, we developed a new MFD, a monolayer device (ML-D) with a barrier structure consisting of pillars and slits, which is simpler in design and easier to make. This ML-D was also effective for inducing mouse spermatogenesis and maintained it for a longer period than the conventional culture method. In addition, we devised a way of introducing sample tissue into the device during its production, just before bonding the upper layer of polydimethylsiloxane (PDMS) and bottom glass slide. The tissue can obtain nutrients horizontally from the medium running beside it and oxygen vertically from above through PDMS. In addition, the glass slide set at the bottom improved the visibility of the sample tissue with an inverted microscope. When we took photos of cultured tissue of the Acr-Gfp transgenic mouse testis in ML-D sequentially every day, morphological changes of the acrosome during spermiogenesis were successfully recorded. The ML-D is simple in design and useful for culturing testis tissue for inducing and maintaining spermatogenesis with clearer visibility. Due to the new method of sample loading, tissues other than testis should also be applicable.

60 APPLIED LIFE SCIENCES↗

An Open Port Sampling Interface for Liquid Introduction Atmospheric Pressure Ionization Mass Spectrometry

RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creating a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A power compensated differential scanning calorimeter for protein stability characterization

This study presented a power compensated MEMS differential scanning calorimeter (DSC) for protein stability characterization. In this microfabricated sensor, PDMS (Polydimethylsiloxane) and polyimide were used to construct the adiabatic chamber (1 μL) and temperature sensitive vanadium oxide was used as the thermistor material. A power compensation system was implemented to maintain the sample and reference at the same temperature. The resolution study and step response characterization indicated the high sensitivity (6 V/W) and low noise level (60 μk) of the device. The test with IgG1 antibody (mAb1) samples showed clear phase transitions and the data was confirmed to be reasonable by comparing it with the results of commercial DSC’s test. Finally, this device used ~1uL sample amount and could complete the scanning process in 4 min, significantly increasing the throughput of the bimolecular thermodynamics study like drug formulation process.

36 MATERIALS SCIENCE↗

A Hyphenated Preconcentrator-Infrared-Hollow-Waveguide Sensor System for N 2 O Sensing

Following the Kyoto protocol, all signatory countries must provide an annual inventory of greenhouse-gas emission including N 2 O. This fact associated with the wide variety of sources for N 2 O emissions requires appropriate sensor technologies facilitating in-situ monitoring, compact dimensions, ease of operation, and sufficient sensitivity for addressing such emission scenarios. In this contribution, we therefore describe an innovative portable mid-infrared chemical sensor system for quantifying gaseous N 2 O via coupling a substrate-integrated hollow waveguide (iHWG) simultaneously serving as highly miniaturized mid-infrared photon conduit and gas cell to a custom-made preconcentrator. N 2 O was collected onto a solid sorbent material packed into the preconcentrator unit, and then released via thermal desorption into the iHWG-MIR sensor utilizing a compact Fourier transform infrared (FTIR) spectrometer for molecularly selective spectroscopic detection with a limit of detection (LOD) at 5 ppbv. Highlighting the device flexibility in terms of sampling time, flow-rate, and iHWG design facilitates tailoring the developed preconcentrator-iHWG device towards a wide variety of application scenarios ranging from soil and aquatic emission monitoring and drone- or unmanned aerial vehicle (UAV)-mounted monitoring systems to clinical/medical analysis scenarios.

Science & Technology - Other Topics↗

Locating the electrical junctions in Cu(In,Ga)Se 2 and Cu 2 ZnSnSe 4 solar cells by scanning capacitance spectroscopy

Here, we determined the electrical junction (EJ) locations in Cu(In,Ga)Se 2 (CIGS) and Cu 2 ZnSnSe 4 (CZTS) solar cells with ~20-nm accuracy by developing scanning capacitance spectroscopy (SCS) applicable to the thin-film devices. Cross-sectional sample preparation for the SCS measurement was developed by high-energy ion milling at room temperature for polishing the cross section to make it flat, followed by low-energy ion milling at liquid nitrogen temperature for removing the damaged layer and subsequent annealing for growing a native oxide layer. The SCS shows distinct p-type, transitional, and n-type spectra across the devices, and the spectral features change rapidly with location in the depletion region, which results in determining the EJ with ~20-nm resolution. We found an n-type CIGS in the region next to the CIGS/CdS interface; thus, the cell is a homojunction. The EJ is ~40 nm from the interface on the CIGS side. In contrast, such an n-type CZTS was not found in the CZTS/CdS cells. The EJ is ~20 nm from the CZTS/CdS interface, which is consistent with asymmetrical carrier concentrations of the p-CZTS and n-CdS in a heterojunction cell. Our results of unambiguously determination of the junction locations contribute significantly to understanding the large open-circuit voltage difference between CIGS and CZTS.

14 SOLAR ENERGY↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

Characterization of Electronic Stress-Induced Changes in Multilayer MoS 2

Transition metal dichalcogenides like molybdenum disulfide (MoS 2 ) are compelling for next-generation electronic devices. In this work, we investigate the impact of electronic stress on MoS 2 to illustrate that observational and phenomenological information on multiple devices can be useful to describe changes in the device, and caution against the rationalization of paltry results as representative or correlative to device behavior. Here, we stress MoS 2 by applying a sustained 20 V DC bias to study the material’s response. Post-stress electronic characterization revealed nonuniform shifts in current–voltage (I–V) behavior alongside microscale changes. Complementary mechanical, spectroscopic, and scanning microwave impedance measurements showed that stress-induced features locally modulate stiffness, surface potential, Raman intensity, and charge carrier density. We correlated I–V behavior with morphological features (wrinkles, tears, folds, height) and device-level geometry (MoS 2 overlap with electrodes, channel area, contact length) on 50 test structures across five chips to move beyond anecdotal conclusions. We found no universal correlations before DC stress. However, device-level geometry was correlated with I–V behavior after DC stress, suggesting that electrode contacts play a more dominant role than morphology in determining performance. Delamination and thinning induced by DC stress led to localized reductions in charge carrier density within the affected regions. Further, delamination and thinning appear to map to I–V device performance in a few samples, but the correlation is lost when a larger sample size is considered. This suggests significant sample-to-sample variability in surface electronic states of the test structures. We also discuss how environmental factors introduced during fabrication may contribute to the observed heterogeneous device response. Progress will require high-resolution, multimodal analysis across many samples constructed under controlled, clean conditions. By building data sets that capture variability, we can better identify the true drivers of performance.

36 MATERIALS SCIENCE↗

Structural, morphological and magnetic study of (Bi{sub 0.1}Fe{sub 0.1}O{sub 3}) - (Ni{sub 0.1}Fe{sub 2(0.1)}O{sub 4}) nanocomposite

Multiferroic nanocomposite of (Bi{sub 0.1}Fe{sub 0.1}O{sub 3}) - (Ni{sub 0.1}Fe{sub 2(0.1)}O{sub 4}) was prepared by sol gel technique and characterized by X-ray diffraction, transmission electron microscopy, superconducting quantum interference device. X-ray diffraction confirmed the formation of desired crystallographic phase of the composite. The average particle size found to be 13.97nm. The transmission electron microscopy depicts the presence of the polycrystalline nanoparticles. In order to investigate the magnetic behavior superconducting quantum interference device was used. The sample was analyzed by increasing the magnetic field up to 25kOe and magnetization was found to be 16.8emu/g, which is optimum for the technological applications. The magnetic properties in such composite result as determined both by the ferrite concentration and properties and by the degree of connectivity of the two phases. The appropriate combination of two phases gives rise to higher magnetization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-F-BRA-06: Dose Distributions for the CivaSheet Pd-103 Directional Brachytherapy Device

Purpose: A flexible polymer membrane (CivaSheet) has been developed by CivaTech Oncology, Inc. (Research Triangle Park, NC) for permanent brachytherapy. Distributed throughout the array are small plastic disks containing Pd-103 and gold foil shielding on one side to provide a directional dose distribution and facilitate imaging. This study evaluated dosimetry for the CivaSheet. Methods: Manufacturer-provided dimensional and compositional information for the device were compared to physical samples for validation of design information, then entered into the MCNP6 radiation transport code for dosimetry simulations. Three device sizes (6×6, 6×12, or 6×18 disk-arrays) were simulated as the membrane can be custom-sized preceding surgical placement. Dose to water was estimated with 0.01 cm resolution from the surface to 10 cm on both sides of the device. Because this is a novel device with calibration methods under development, results were normalized using DVHs to provide 90% prescription coverage to a plane positioned 0.5 cm from the front surfaces. This same normalization was used for creating isodose distributions. Results: Planar dose distributions of flat CivaSheets were relatively homogeneous with acceptable dose uniformity variations. Differences in the results between the differently sized CivaSheets were not significant. At 0.5 mm, 87% of the target volume was within the therapeutic dose range. Dose hotspots on the CivaSheet forward surfaces were directly above the disks. However, dose hotspots on the rear-facing surfaces were positioned between the disks. Doses in contact with the front surface were similar to those observed for currently available brachytherapy sources. Maximum doses that occurred on the rear surface were approximately 55 times lower than the dose on the front surface. Conclusion: Monte Carlo calculations validated the directional capabilities and advantageous dosimetry of the new Pd-103 brachytherapy device. It appears feasible to re-size the CivaSheet in the operating room with an acceptable variation in prescription dose. Research was supported by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Quantitative secondary electron detection

Quantitative Secondary Electron Detection (QSED) using the array of solid state devices (SSD) based electron-counters enable critical dimension metrology measurements in materials such as semiconductors, nanomaterials, and biological samples (FIG. 3). Methods and devices effect a quantitative detection of secondary electrons with the array of solid state detectors comprising a number of solid state detectors. An array senses the number of secondary electrons with a plurality of solid state detectors, counting the number of secondary electrons with a time to digital converter circuit in counter mode.

47 OTHER INSTRUMENTATION↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

A sui generis whipping-instability-based self-sequencing multi-monodisperse 2D spray from an anisotropic microfluidic liquid jet device

Well-defined aerosols pave the way for versatile basic and applied research. Here, we demonstrate a unique whipping instability that generates from a high-aspect-ratio microfluidic device resulting in a unique steady-state gas-focused whipping jet (WJ) without any need for electrification. This WJ device emanates a multi-monodisperse whipping spray jet with a two-dimensional (2D) profile. We demonstrate this phenomenon based on various fluidic parameters theoretically and experimentally. The 2D WJ’s unique behavior is derived using analytical fluid dynamics to explain jet diameter, whipping regime, and spreading angle. The phenomenon is further characterized experimentally by measuring the angle with respect to the flow rate, the distances between droplets, the droplet shapes, and the reproducibility of these parameters. We also explain the precise fabrication of such inexpensive devices. Lastly, we highlight these devices’ potential use as sample environments in versatile applications ranging from cryoelectron microscopy over mass spectrometry to drug formulation and structural studies at X-ray free-electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the photocurrents generated by the laser of atomic force microscopes

The conductive atomic force microscope (CAFM) has become an essential tool for the nanoscale electronic characterization of many materials and devices. When studying photoactive samples, the laser used by the CAFM to detect the deflection of the cantilever can generate photocurrents that perturb the current signals collected, leading to unreliable characterization. In metal-coated semiconductor samples, this problem is further aggravated, and large currents above the nanometer range can be observed even without the application of any bias. Here we present the first characterization of the photocurrents introduced by the laser of the CAFM, and we quantify the amount of light arriving to the surface of the sample. The mechanisms for current collection when placing the CAFM tip on metal-coated photoactive samples are also analyzed in-depth. Finally, we successfully avoided the laser-induced perturbations using a two pass technique: the first scan collects the topography (laser ON) and the second collects the current (laser OFF). We also demonstrate that CAFMs without a laser (using a tuning fork for detecting the deflection of the tip) do not have this problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗