Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multimodal sensor fusion framework for residential building occupancy detection

For several years now, smart building energy systems have been a research area of intensive activity. In light of the increasing need for sustainable buildings and energy systems, this trend motivates an increasing need for a solution to reduce carbon dioxide emissions and improve energy efficiency. This work proposes a high-performing and transferable occupancy detection framework that combines sensor data from different data modalities, including time series environmental data (temperature, humidity, and illuminance), image data, and acoustic energy data using ensemble method. To draw out the best prediction performance in each modality, the proposed framework was developed, including various models that were designed to learn the occupancy patterns reflected in the physical data streams. To tackle the time series environmental data, we designed two variants of an occupancy detection spatiotemporal pattern network (Occ-STPN) that performs both feature level and decision level fusion, respectively. We also propose a new metric; the fading memory mean square error (FMMSE), that provides a fair evaluation and penalization of delayed occupancy predictions. Multiple open-sourced datasets, including the Electricity Consumption and Occupancy and the University of California, Irvine's (UCI) building occupancy detection dataset, along with our own real data collected from six different houses, were used to validate the algorithms' performance. The experimental results presented herein break down the performance for each sensing modality, and a detailed analysis of the performance is also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

A high-fidelity residential building occupancy detection dataset

Abstract This paper describes development of a data acquisition system used to capture a range of occupancy related modalities from single-family residences, along with the dataset that was generated. The publicly available dataset includes: grayscale images at 32-by-32 pixels, captured every second; audio files, which have undergone processing to remove personally identifiable information; indoor environmental readings, captured every ten seconds; and ground truth binary occupancy status. The data acquisition system, coined the mobile human presence detection (HPDmobile) system, was deployed in six homes for a minimum duration of one month each, and captured all modalities from at least four different locations concurrently inside each home. The environmental modalities are available as captured, but to preserve the privacy and identity of the occupants, images were downsized and audio files went through a series of processing steps, as described in this paper. This dataset adds to a very small body of existing data, with applications to energy efficiency and indoor environmental quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance based approaches in standards and regulations for smart ventilation in residential buildings: a summary review

As ventilation systems become more sophisticated (or ‘smart’) standards and regulations are changing to accommodate their use. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or IAQ advantage (or both) and less when it provides a disadvantage. This paper discusses the favorable contexts that exist in many countries, with regulations and standards proposing ‘performance-based approaches’ that both enable and reward smart ventilation. The paper gives an overview of such approaches from five countries. The common thread in all these methods is the use of metrics for the exposure to an indoor generated parameter (usually CO 2 ), and condensation risk. As the result, demand-control ventilation strategies (DCV) are widely and easily available on the market, with more than 20–30 systems available in some countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory and field validation of the performance benefits and costs of thin triple-pane windows in residential buildings

The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hierarchical Model-Free Transactive Control of Residential Building Loads: An Actual Deployment

The transformation of electricity systems into more sustainable configurations brought some new challenges. The uncertain, intermittent, and variable nature of renewable energy sources require a significant amount of load demand flexibility, in which grid-interactive buildings (GEBs) are important flexible assets for electricity systems. In this regard, many demand response (DR) tools have been developed to harness this demand flexibility. However, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a real-world field implementation and testing of a hierarchical model-free transactive DR control approach on actual GEBs. The control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. The proposed approach was tested using a total of five GEBs, each having three zones. The results show that the proposed approach can mostly achieve all intended objectives, including flexibility estimation, peak load reduction, power tracking, and controlling GEBs while maintaining occupants’ comfort.

Amasyali, Kadir↗

Small Business Voucher CRADA Report: Natural Gas Powered HVAC System for Commercial and Residential Buildings

Be Power Tech is commercializing BeCool, the first integrated electricity-producing heating, ventilation, and air conditioning (HVAC) system using a non-vapor compression cycle (VCC), packaged rooftop HVAC unit that also produces base-load electricity, heating, ventilation, and air conditioning. BeCool is a distributed energy resource with energy storage that eliminates the tremendous peak electricity demand associated with commonly used electricity-powered vapor compression air conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent Energy Optimizer for Residential Buildings

Demand-side management in the buildings is essential for meeting grid flexibility needs in a highly renewable energy scenario. Appliance load monitoring helps decision making for demand-side management by providing the information on operation status/power consumption from different appliances in the buildings. Nonintrusive load monitoring (NILM) is an attractive option for appliance load monitoring using because it has lower cost for sensors and helps mitigate privacy concerns. In this study, the team used an event detection technique followed by two different methods for event classification. The results from k-means clustering showed that the events from a single appliance are often distributed in multiple clusters. Thus, the unsupervised method of NILM using k-means clustering used in this study was not very suitable for load disaggregation. The results from NILM showed that the F1 score for event classification was 0.77 for a heat pump water heater and very low for other appliances using the rule-based classification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimating Demand Response Load Impacts: Evaluation of BaselineLoad Models for Non-Residential Buildings in California

Both Federal and California state policymakers areincreasingly interested in developing more standardized and consistentapproaches to estimate and verify the load impacts of demand responseprograms and dynamic pricing tariffs. This study describes a statisticalanalysis of the performance of different models used to calculate thebaseline electric load for commercial buildings participating in ademand-response (DR) program, with emphasis onthe importance of weathereffects. During a DR event, a variety of adjustments may be made tobuilding operation, with the goal of reducing the building peak electricload. In order to determine the actual peak load reduction, an estimateof what the load would have been on the day of the event without any DRactions is needed. This baseline load profile (BLP) is key to accuratelyassessing the load impacts from event-based DR programs and may alsoimpact payment settlements for certain types of DR programs. We testedseven baseline models on a sample of 33 buildings located in California.These models can be loosely categorized into two groups: (1) averagingmethods, which use some linear combination of hourly load values fromprevious days to predict the load on the event, and (2) explicit weathermodels, which use a formula based on local hourly temperature to predictthe load. The models were tested both with and without morningadjustments, which use data from the day of the event to adjust theestimated BLP up or down.Key findings from this study are: - The accuracyof the BLP model currently used by California utilities to estimate loadreductions in several DR programs (i.e., hourly usage in highest 3 out of10 previous days) could be improved substantially if a morning adjustmentfactor were applied for weather-sensitive commercial and institutionalbuildings. - Applying a morning adjustment factor significantly reducesthe bias and improves the accuracy of all BLP models examined in oursample of buildings. - For buildings with low load variability, all BLPmodels perform reasonably well in accuracy. - For customer accounts withhighly variable loads, we found that no BLP model produced satisfactoryresults, although averaging methods perform best in accuracy (but notbias). These types of customers are difficult to characterize withstandard BLP models that rely on historic loads and weather data.Implications of these results for DR program administrators andpolicymakersare: - Most DR programs apply similar DR BLP methods tocommercial and industrial sector customers. The results of our study whencombined with other recent studies (Quantum 2004 and 2006, Buege et al.,2006) suggests that DR program administrators should have flexibility andmultiple options for suggesting the most appropriate BLP method forspecific types of customers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Statistical Analysis of Baseline Load Models for Non-Residential Buildings

Policymakers are encouraging the development of standardized and consistent methods to quantify the electric load impacts of demand response programs. For load impacts, an essential part of the analysis is the estimation of the baseline load profile. In this paper, we present a statistical evaluation of the performance of several different models used to calculate baselines for commercial buildings participating in a demand response program in California. In our approach, we use the model to estimate baseline loads for a large set of proxy event days for which the actual load data are also available. Measures of the accuracy and bias of different models, the importance of weather effects, and the effect of applying morning adjustment factors (which use data from the day of the event to adjust the estimated baseline) are presented. Our results suggest that (1) the accuracy of baseline load models can be improved substantially by applying a morning adjustment, (2) the characterization of building loads by variability and weather sensitivity is a useful indicator of which types of baseline models will perform well, and (3) models that incorporate temperature either improve the accuracy of the model fit or do not change it.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗