Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relocation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Comfort and HVAC Performance for a New Construction Occupied Test House in Roseville, California

K. Hovnanian(R) Homes(R) constructed a 2,253-ft2 single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RERTR-12 Post-irradiation Examination Summary Report

The following report contains the results and conclusions for the post irradiation examinations performed on RERTR-12 Insertion 2 experiment plates. These exams include eddy-current testing to measure oxide growth; neutron radiography for evaluating the condition of the fuel prior to sectioning and determination of fuel relocation and geometry changes; gamma scanning to provide relative measurements for burnup and indication of fuel- and fission-product relocation; profilometry to measure dimensional changes of the fuel plate; analytical chemistry to benchmark the physics burnup calculations; metallography to examine the microstructural changes in the fuel, interlayer and cladding; and microhardness testing to determine the material-property changes of the fuel and cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Short-Term Monitoring Results for Advanced New Construction Test House—Roseville, California

A builder (K. Hovnanian® Homes®), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft 2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols, while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic to conditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing of individual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comfort and HVAC Performance for a New Construction Occupied Test House in Roseville, California

K. Hovnanian® Homes constructed a 2,253-ft2 single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Term Monitoring Results for Advanced New Construction Test House -- Roseville, California

A builder (K. Hovnanian Homes), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols (Hendron, R. and Engebrecht, C. 'Building America House Simulation Protocols.' Golden, CO: National Renewable EnergyLaboratory, 2010) while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic toconditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing ofindividual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The SAS4A/SASSYS-1 Safety Analysis Code System, Version 5

The SAS4A/SASSYS-1 computer code is developed by Argonne National Laboratory for thermal, hydraulic, and neutronic analysis of power and flow transients in liquidmetal- cooled nuclear reactors (LMRs). SAS4A was developed to analyze severe core disruption accidents with coolant boiling and fuel melting and relocation, initiated by a very low probability coincidence of an accident precursor and failure of one or more safety systems. SASSYS-1, originally developed to address loss-of-decay-heat-removal accidents, has evolved into a tool for margin assessment in design basis accident (DBA) analysis and for consequence assessment in beyond-design-basis accident (BDBA) analysis. SAS4A contains detailed, mechanistic models of transient thermal, hydraulic, neutronic, and mechanical phenomena to describe the response of the reactor core, its coolant, fuel elements, and structural members to accident conditions. The core channel models in SAS4A provide the capability to analyze the initial phase of core disruptive accidents, through coolant heat-up and boiling, fuel element failure, and fuel melting and relocation. Originally developed to analyze oxide fuel clad with stainless steel, the models in SAS4A have been extended and specialized to metallic fuel with advanced alloy cladding. SASSYS-1 provides the capability to perform a detailed thermal/hydraulic simulation of the primary and secondary sodium coolant circuits and the balance-ofplant steam/water circuit. These sodium and steam circuit models include component models for heat exchangers, pumps, valves, turbines, and condensers, and thermal/hydraulic models of pipes and plena. SASSYS-1 also contains a plant protection and control system modeling capability, which provides digital representations of reactor, pump, and valve controllers and their response to input signal changes.

97 MATHEMATICS AND COMPUTING↗

Brentwood Lessons Learned Project Report

The purpose of this report is to document lessons learned in the installation of the hydrogen fueling station at the National Park Service Brentwood site in Washington, D.C., to help further the deployment of hydrogen infrastructure required to support hydrogen and other fuel cell technologies. Hydrogen fueling is the most difficult infrastructure component to build and permit. Hydrogen fueling can include augmenting hydrogen fueling capability to existing conventional fuel fueling stations as well as building brand new hydrogen fueling stations. This report was produced as part of the Brentwood Lessons Learned project. The project consisted of transplanting an existing modular hydrogen fueling station from Connecticut to the National Park Service Brentwood site. This relocation required design and construction at the Brentwood site to accommodate the existing station design as well as installation and validation of the updated station. One of the most important lessons learned was that simply moving an existing modular station to an operating site was not necessarily straight-forward - performing the relocation required significant effort and cost. The station has to function at the selected operating site and this functionality requires a power supply, building supports connecting to an existing alarm system, electrical grounding and lighting, providing nitrogen for purging, and providing deionized water if an electrolyzer is part of the station package. Most importantly, the station has to fit into the existing site both spatially and operationally and not disrupt existing operations at the site. All of this coordination and integration requires logistical planning and project management. The idea that a hydrogen fueling station can be simply dropped onto a site and made immediately operational is generally not realistic. Other important lessons learned include that delineating the boundaries of the multiple jurisdictions that have authority over a project for all parties involved in the project are key to an efficient approval process; and site investigation is necessary when integrating a new station design onto an existing site, particularly an older existing site that may have limited documentation on the site history and operations. The lessons learned for permitting and subcontracting construction work can be applied to other similar sites and to commercial sites.

30 DIRECT ENERGY CONVERSION↗

Parametric and experimentally informed BWR Severe Accident Analysis Utilizing FeCrAl - M3FT-17OR020205041

Iron-chromium-aluminum (FeCrAl) alloys are being considered as advanced fuel cladding concepts with enhanced accident tolerance. At high temperatures, FeCrAl alloys have slower oxidation kinetics and higher strength compared with zirconium-based alloys. FeCrAl could be used for fuel cladding and spacer or mixing vane grids in light water reactors and/or as channel box material in boiling water reactors (BWRs). There is a need to assess the potential gains afforded by the FeCrAl accident-tolerant-fuel (ATF) concept over the existing zirconium-based materials employed today. To accurately assess the response of FeCrAl alloys under severe accident conditions, a number of FeCrAl properties and characteristics are required. These include thermophysical properties as well as burst characteristics, oxidation kinetics, possible eutectic interactions, and failure temperatures. These properties can vary among different FeCrAl alloys. Oak Ridge National Laboratory has pursued refined values for the oxidation kinetics of the B136Y FeCrAl alloy (Fe-13Cr-6Al wt %). This investigation included oxidation tests with varying heating rates and end-point temperatures in a steam environment. The rate constant for the low-temperature oxidation kinetics was found to be higher than that for the commercial APMT FeCrAl alloy (Fe-21Cr-5Al-3Mo wt %). Compared with APMT, a 5 times higher rate constant best predicted the entire dataset (root mean square deviation). Based on tests following heating rates comparable with those the cladding would experience during a station blackout, the transition to higher oxidation kinetics occurs at approximately 1,500°C. A parametric study varying the low-temperature FeCrAl oxidation kinetics was conducted for a BWR plant using FeCrAl fuel cladding and channel boxes using the MELCOR code. A range of station blackout severe accident scenarios were simulated for a BWR/4 reactor with Mark I containment. Increasing the FeCrAl low-temperature oxidation rate constant (3 times and 10 times that of the rate constant for APMT) had a negligible impact on the early stages of the accident and minor impacts on the accident progression after the first relocation of the fuel. At temperatures below 1,500°C, increasing the rate constant for APMT by a factor of 10 still resulted in only minor FeCrAl oxidation. In general, the gains afforded by the FeCrAl enhanced ATF concept with respect to accident sequence timing and combustible gas generation are consistent with previous efforts. Compared with the traditional Zircaloy-based cladding and channel box system, the FeCrAl concept could provide a few extra hours of time for operators to take mitigating actions and/or for evacuations to take place. A coolable core geometry is retained longer, enhancing the ability to stabilize an accident. For example, a station blackout was simulated in which cooling water injection was lost 36 hours after shutdown. The timing to first fuel relocation was delayed by approximately 5 h for the FeCrAl ATF concept compared with that of the traditional Zircaloy-based cladding and channel box system.

36 MATERIALS SCIENCE↗

Development of a LOCA Experimental Benchmark for BISON - Milestone L2:FMC.P15.08

Since 2013 CASL has been planning and working towards a PWR LOCA Challenge Problem. Since BISON is the CASL fuel rod simulation platform, it plays a central role in that activity. The goal of the FY-17 CASL milestone reported here was to develop an Experimental Benchmark for LOCA analysis using BISON. Activities encompassed both code development and validation. This report provides a current snapshot of BISON’s capability for LOCA behavior including: 1) a summary of code extensions to facilitate accident analysis, 2) a series of separate effects tests, and 3) initial code validation to complex integral rod LOCA behavior. Conclusions from each of these main activities are summarized below. The key material and behavior models required to address transient high-temperature phenomena occurring during LOCAs in a standard PWR have now been implemented in BISON. These apply specifically to UO2 fuel, Zircaloy cladding and water coolant. During FY-17 important new capability to address axial UO2 fuel relocation (for 1.5D geometry) and account for oxidation energy deposition in cladding, were included. Planned future development efforts include extending the axial fuel relocation model from 1.5D to 2D/3D and improving BISON’s fission gas release model to include transient gas release associated with the high burnup structure (HBS) in high burnup fuel. Additionally, investigation of potential anisotropic creep behavior in Zircaloy cladding is planned, assuming sufficient experimental data are available to support this effort. A substantial number of separate effects validation cases (42 tests from 3 experimental series) have been completed to compare BISON predictions to measured ballooning and burst behavior for Zircaloy cladding. Such experiments include a wide variety of pressures, temperatures and loading rates. In general, BISON predictions of burst temperature, pressure and burst time are very reasonable. For one experimental series, however, involving both very high temperatures and strain rates, BISON systematically over-predicts the cladding hoop strain. Investigation of this discrepancy is an important and planned activity. With another experiment an effort was made to investigate 3D cladding response due to an azimuthal temperature variation. Results indicated 3D effects are potentially important in fuel rod analysis during LOCAs and will be further investigated in the future. BISON validation to a series of integral fuel rod experiments has also been completed. These experiments involve all fuel and cladding phenomena relevant to LOCA conditions, and can include complexities associated with irradiated fuel relative to fresh fuel. Such experiments also generally include complex thermal-hydraulic boundary conditions. Four experiments (6 rods) have been considered to date including simulated fuel (ZrO2) and both fresh and high-burnup UO2. Test rods ranged from rodlets to full length commercial PWR fuel rods. As with the separate effects experiments, BISON predictions of burst temperature, pressure and burst time are generally very reasonable. Comparisons to cladding peak strain and rod outer diameter axial profiles are less satisfactory, and identify material models and possibly modeling approximations (e.g., 2D-RZ vs 3D geometries) requiring additional investigation. Validation of BISON for integral rod LOCA behavior is by no means complete, with additional cases planned.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TA-II Sub-Area Plan: Overview & Summary

Technical Area II is a brownfield site with a central, but “backyard” location that makes it a perfect area for site-support activities, particularly those that can be relocated from the TA-I “front-yard.” TA-II has a large amount of undeveloped land that should be held in reserve for future R&D mission work. Specifically, the Sub-Area Plan recommends: (1) Accommodating primarily site-support land uses, including site-support functions that can be relocated from TA-I; (2) Preserving land for future mission development opportunities which also protects sensitive environmental areas; (3) Locating future development along the Hardin and 9th Avenue corridors where existing infrastructure exists; and (4) Constructing critical infrastructure links (e.g., roads and utilities).

99 GENERAL AND MISCELLANEOUS↗

3D Crustal Tomography Model of Utah

The ability to accurately locate seismic events is necessary for treaty monitoring. When using techniques that rely on the comparison of observed and predicted travel times to obtain these locations, it is important that the estimated travel times and their estimated uncertainties are also accurate. The methodology of Ballard et al. (2016a) has been used in the past to generate an accurate 3D tomographic global model of compressional wave slowness (the SAndia LoS Alamos 3D tomography model, i.e. SALSA3D). To re-establish functionality and to broaden the capabilities of the method to local distances, we have applied the methodology of Ballard et al. (2016a) to local data in Utah. This report details the results of the initial model generated, including relocations performed using analyst picked mining events at West Ridge Mine and three ground-truth events at Bingham Mine. We were successfully able to generate a feasible tomography model that resulted in reasonable relocations of the mining events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compare predictions of transient fission gas release by empirical and mechanistic models to experiments in high burnup UO 2 fuel

Understanding and predicting fuel performance at high burnup require improving our understanding of transient fission gas release. High-burnup operations enable new mechanisms of fission gas release, which affect fuel performance. The Nuclear Regulatory Commission has recently published its interpretation of existing fuel fragmentation, relocation, and dispersal data in a research information letter. There, transient fission gas release was identified as one of the main factors that contributes to fuel fragmentation, relocation, and dispersal, and therefore limits fuel extension to high burnup. However, transient fission gas release is a complex phenomenon that cannot be fully described by simple empirical descriptions. This report summarizes the development of a mechanistic model for high-burnup transient fission gas release in the fuel performance code BISON. This research was supported by the Nuclear Energy Advanced Modeling and Simulation program during fiscal year 2023 to improve our understanding of high-burnup transient fission gas release and ability to predict it as a function of operation history. To support the development of a mechanistic transient fission gas release model, the existing Simple Integrated Fission Gas Release and Swelling (Sifgrs) model in BISON has been completely refactored to make it more modular and extensible. This effort supports the model's application to high-burnup conditions, its extension to other fuel forms, and the continuous improvement of its current features. Once refactoring was completed, models for high-burnup structure formation, fission gas transfer from non-restructured fuel to high-burnup structure, high-burnup structure intragranular and intergranular fission gas behavior, high-burnup structure bubble evolution, fuel pulverization, and the resulting transient fission gas release were tested and implemented in the Simple Integrated Fission Gas Release and Swelling (Sifgrs) model or tightly coupled to it. The new mechanistic model was then compared to an empirical model developed in parallel by a Nuclear Energy University Program project using a Studsvik high-burnup loss-of-coolant-accident assessment case. Finally, the report details the preliminary BISON results for a benchmark activity organized by the Nuclear Energy Agency to evaluate fuel performance codes' predictive capabilities for burst fission gas release. This work represents an important step toward a mechanistic understanding of fission gas release in high-burnup conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modelling the Liquid Waste Operation at the Savannah River Site

Modeling Successes Dounreay – Site Closure Optimization and Risk Reduction Re-structuring and streamlining a complex project plan to achieve site decommissioning in reduced time and at reduced cost, through automated task prioritization. Idaho AMWTP – Multi-stream Optimization Speeding up a complex facility with many process lines, by utilizing all of the process lines more efficiently and reducing overall plant downtime, by coordinating repairs and shutdowns. AWE –Waste Repackaging and Relocation Relocating schedule for waste material from an old storage facility to a new purpose-built one, safely, and in a timely fashion that removed the need to reassure the safety of the old facility. Sellafield – Effluent, Sludge and HAW Treatment Improving a wide range of chemical engineered processes including aqueous effluent treatment, chemically-reactive sludge management and waste vitrification processing. Strategic Petroleum Reserve – Cavern Management Linking chemistry models of petroleum prediction, through engineering cavern management to financial modeling of gasoline sales to benefit US government

Jung, Andrew W.↗

Los Alamos National Laboratory Floodplain Assessment for the TA-72 Guard Post 10 Expedited Vehicle Lane Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction in lower Sandia Canyon at Technical Area (TA) 72 at the Guard Post 10 vehicle inspection station at Los Alamos National Laboratory (LANL). The proposed project is intended to provide expedited inspection times for vehicles transporting time sensitive loads, such as concrete and asphalt. The project activities within the 100-year floodplain include installation of 1) installation of an expedited vehicle inspection lane, 2) relocation of a 4-strand wire fence, 3) possible relocation of at least one power pole, and 4) a laydown area (Figures 1 and 2).

42 ENGINEERING↗

Demonstration of new fracture criteria based on micro-structure and compare to empirical model and measurements

The US nuclear industry is currently exploring extending the peak rod average burnup limits above the current regulatory limit of 62 GWd/tU. A potential concern for fuel exceeding the burnup limit is the fragmentation during a temperature transient such as a loss-of-coolant accident (LOCA). In the event of cladding failure, the fragmented fuel could relocate and disperse within the reactor. The potential impact of fuel fragmentation, relocation and dispersal (FFRD) on licensing assumptions for burnup extension has focused a great amount of efforts and research on this topic.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent High Burnup LOCA Testing at Oak Ridge National Laboratory

To improve fuel cycle economics, increasing the fuel burnup limit in light-water reactors requires a solid technical foundation. Observations from experiments at Halden and Studsvik highlighted severe fuel fragmentation during loss-of-coolant-accident (LOCA) conditions, indicating a need for further technical considerations. These experiments suggest that the fragmentation threshold for high-burnup fuel might be influenced by pre-transient power levels. Consequently, additional LOCA test data are essential to complement existing findings and to deepen our understanding. Oak Ridge National Laboratory’s Severe Accident Test Station has been instrumental in advancing knowledge about high-burnup fuel fragmentation, relocation, and dispersal. This milestone report details two high-burnup LOCA tests designed to evaluate the effects of terminal temperature and grid spacers (or cladding restraints) on fuel fragmentation and relocation susceptibility. In addition, BISON fuel performance modeling and out-of-cell benchmark testing were conducted to better interpret the in-cell test results. These tests were developed in collaboration with fuel vendors to ensure that the results provide valuable data for topical reports and support the Nuclear Regulatory Commission’s review.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Temporary Restoration of Bull Trout Passage at Albeni Falls Dam

This study was designed to monitor movements of bull trout that were provided passage above Albeni Falls Dam, Pend Oreille River. Electrofishing and angling were used to collect bull trout below the dam. Tissue samples were collected from each bull trout and sent to the U. S. Fish and Wildlife Service Abernathy Fish Technology Center Conservation Genetics Lab, Washington. The DNA extracted from tissue samples were compared to a catalog of bull trout population DNA from the Priest River drainage, Lake Pend Oreille tributaries, and the Clark Fork drainage to determine the most probable tributary of origin. A combined acoustic radio or radio tag was implanted in each fish prior to being transported and released above the dam. Bull trout relocated above the dam were able to volitionally migrate into their natal tributary, drop back downstream, or migrate upstream to the next dam. A combination of stationary radio receiving stations and tracking via aircraft, boat, and vehicle were used to monitor the movement of tagged fish to determine if the spawning tributary it selected matched the tributary assigned from the genetic analysis. Seven bull trout were captured during electrofishing surveys in 2008. Of these seven, four were tagged and relocated above the dam. Two were tagged and left below the dam as part of a study monitoring movements below the dam. One was immature and too small at the time of capture to implant a tracking tag. All four fish released above the dam passed by stationary receivers stations leading into Lake Pend Oreille and no fish dropped back below the dam. One of the radio tags was recovered in the tributary corresponding with the results of the genetic test. Another fish was located in the vicinity of its assigned tributary, which was impassable due to low water discharge at its mouth. Two fish have not been located since entering the lake. Of these fish, one was immature and not expected to enter its natal tributary in the fall of 2008. The other fish was large enough to be mature, but at the time of capture its sex was unable to be determined, indicating it may not have been mature at the time of capture. These fish are expected to enter their natal tributaries in early summer or fall of 2009.

13 HYDRO ENERGY↗

Development of an Updated Societal-Risk Goal for Nuclear Power Safety

This report briefly summarizes work done in FY 2013 on the subject LDRD. The working hypothesis is that societal disruption should be addressed in a safety goal. This is motivated by the point that the Fukushima disaster resulted in very little public dose, but enormous societal disruption; a goal that addressed societal disruption would fill a perceived gap in the US NRC safety goal structure. This year's work entailed analyzing the consequences of postulated accidents at various reactor sites in the US, specifically with a view to quantifying the number of people relocated and the duration of their relocation, to see whether this makes sense as a measure of societal disruption.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗