Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Source Replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The DD Neutron Generator as an Alternative to Am(Li) Isotopic Neutron Source in the Uranium Neutron Coincidence Collar

The 235 U mass assay of bulk uranium items, such as oxide canisters, fuel pellets, and fuel assemblies, is not achievable by traditional gamma-ray assay techniques because of the limited penetration of the item by the characteristic 235 U gamma rays. Instead, fast neutron interrogation methods such as active neutron coincidence counting must be used. For international safeguards applications, the most commonly used active neutron systems, the Active Well Coincidence Counter (AWCC), Uranium Neutron Coincidence Collar (UNCL), and 252 Cf Shuffler, rely on fast neutron interrogation using an isotopic neutron source [i.e., 252 Cf or Am(Li)] to achieve better measurement accuracies than are possible using gamma-ray techniques for high-mass, high-density items. However, the Am(Li) sources required for the AWCC and UNCL systems are no longer manufactured, and newly produced systems rely on limited supplies of sources salvaged from disused instruments. The 252 Cf shuffler systems rely on the use of high-output 252 Cf sources, which while still available have become extremely costly for use in routine operations and require replacement every 5–7 years. Lack of a suitable alternative neutron interrogation source would leave a potentially significant gap in the safeguarding of uranium processing facilities. Previously we examined the performance of Oak Ridge National Laboratory’s Large Volume Active Well Coincidence Counter modified to accept a commercially available deuterium-deuterium (DD) neutron generator to examine the potential of the DD neutron generator as an alternative to the isotopic sources [1]. That work indicated that the DD generator was a viable replacement for the AWCC applications, but because of the large dimensions of that generator, the DD/AWCC would have to be run as a delayed neutron counting system to provide equivalent measurement precision. In this work we examine the performance of a standard UNCL modified to accept the DD neutron generator for the assay of 235 U based on the results of Monte Carlo N-Particle (MCNP) simulations and measurements of depleted uranium and highly enriched uranium items. The projected performance of the modified UNCL for fresh pressurized water reactor fuel assemblies operated in both traditional coincidence counting and delayed neutron counting modes is presented.

07 ISOTOPE AND RADIATION SOURCES↗

Methods of Fabricating Scintillators with Radioisotopes for Beta Battery Applications

Technology has been developed for a class of self-contained, long-duration power sources called beta batteries, which harvest the energy contained in the radioactive emissions from beta decay isotopes. The new battery is a significant improvement over the conventional phosphor/solar cell concept for converting this energy in three ways. First, the thin phosphor is replaced with a thick scintillator that is transparent to its own emissions. By using a scintillator sufficiently thick to completely stop all the beta particles, efficiency is greatly improved. Second, since the energy of the beta particles is absorbed in the scintillator, the semiconductor photodetector is shielded from radiation damage that presently limits the performance and lifetime of traditional phosphor converters. Finally, instead of a thin film of beta-emitting material, the isotopes are incorporated into the entire volume of the thick scintillator crystal allowing more activity to be included in the converter without self-absorption. There is no chemical difference between radioactive and stable strontium beta emitters such as Sr-90, so the beta emitter can be uniformly distributed throughout a strontium based scintillator crystal. When beta emitter material is applied as a foil or thin film to the surface of a solar cell or even to the surface of a scintillator, much of the radiation escapes due to the geometry, and some is absorbed within the layer itself, leading to inefficient harvesting of the energy. In contrast, if the emitting atoms are incorporated within the scintillator, the geometry allows for the capture and efficient conversion of the energy of particles emitted in any direction. Any gamma rays associated with secondary decays or Bremsstrahlung photons may also be absorbed within the scintillator, and converted to lower energy photons, which will in turn be captured by the photocell or photodiode. Some energy will be lost in this two-stage conversion process (high-energy particle to low-energy photons to electric current). The geometric advantage partially offsets this as well, since the absorption depth of high-energy beta radiation is much larger than the depth of a p-n junction. Thus, in a p-n junction device, much of the radiation is absorbed far away from the junction, and the electron- hole pairs are not all effectively collected. In contrast, with a transparent scintillator the radiation can be converted to light in a larger volume, and all of the light can be collected in the active region of the photodiode. Finally, the new device is more practical because it can be used at much higher power levels without unduly shortening its lifetime. While the crystal structure of scintillators is also subject to radiation damage, their performance is far more tolerant of defects than that of semiconductor junctions. This allows the scintillator- based approach to use both higher energy isotopes and larger quantities of the isotopes. It is projected that this technology has the potential to produce a radioisotope battery with up to twice the efficiency of presently used systems.

Rensing, Noa M.↗

Ways to improve the efficiency and reliability of radio frequency driven negative ion sources for fusion

Large RF driven negative hydrogen ion sources are being developed at IPP Garching for the future neutral beam injection system of ITER. The overall power efficiency of these sources is low, because for the RF power supply self-excited generators are utilized and the plasma is generated in small cylindrical sources (“drivers”) and expands into the source main volume. At IPP experiments to reduce the primary power and the RF power required for the plasma production are performed in two ways: The oscillator generator of the prototype source has been replaced by a transistorized RF transmitter and two alternative driver concepts, a spiral coil, in which the field is concentrated by ferrites, which omits the losses by plasma expansion and a helicon source are being tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On-axis brilliance and power of in-vacuum undulators for the Advanced Photon Source.

A request for studying the spectral performance of in-vacuum undulators (IVUs) for the APS storage ring was recently put forward. In-vacuum undulators are prevalent at other synchrotron radiation facilities such as the ESRF and the Spring-8. However, they never made it into the arsenal of undulators at the APS because the brilliance tuning curves were sufficiently wide due to the fact that the undulator minimum gap could be set as low as 10.5 mm. For sector 3, which in the past used a narrow-gap vacuum chamber, the minimum undulator pole gap was allowed to be set as low as 8.5 mm, providing contiguous tuning curves between the first and third harmonic radiation for a 2.7-cm-period device. (Subsequently, the narrow-gap vacuum chamber was removed and replaced with a standard vacuum chamber, which allows a minimum gap of 10.5 mm.) For sector 4, which currently holds the only narrow-gap vacuum chamber at the APS, the minimum gap is 9.5 mm. In this sector, a permanent magnet hybrid undulator with SmCo magnets is used instead of NdFeB magnets because of their higher radiation resistance and their better protection against radiation-induced demagnetization of the magnets. In the realm of looking to the future, new concepts and technologies are being revisited. Most notable is the superconducting undulator (SCU) technology, which provides the ultimate highest magnetic field of any technology and design. The SCU program has been ongoing at the APS for several years and substantial progress has been made.3,4 However, the in-vacuum undulators may bridge some of the user demands, and it is therefore worthwhile revisiting their potential at the APS. In this work, the following were assumed or required: (1) the smallest in-vacuum beam-stay-clear gap is 5.0 mm, (2) a beam-liner of 2 x 0.060 mm, which increases the pole gap by the same amount, (3) both NdFeB and SmCo magnets shall be studied, even though SmCo magnets are the preferred choice for very small gaps, (4) compare the in-vacuum undulators with superconducting NbTi undulators with a wall thickness/space of 2 x 1.0 mm, and (5) all undulators will have an effective magnetic length of 2.4 m. Three short undulator period lengths were chosen somewhat arbitrary and studied. We will compare the performance of undulators with period lengths of 2.5 cm and 2.0 cm to one with a 1.6-cm period, which is the chosen period length of the first designed and tested short-length SCU for the APS. Additionally, we will make comparisons with the undulator A, which has a period length of 3.3 cm.

43 PARTICLE ACCELERATORS↗

Overview of Lattice Design and Evaluation for the APS Upgrade

The Advanced Photon Source (APS) is a 7-GeV synchrotron light source that has been in operation since 1996. Since that time, the effective emittance has been decreased from 8 nm to 3.1 nm, which is very competitive for a 3rd-generation light source. However, newer facilities such as PETRA-III, NSLS-II, and MAX-IV are pushing the emittance to significantly smaller values. MAX-IV in particular has set the current benchmark with an emittance of about 300 pm at 3 GeV. This was accomplished by use of a multi-bend achromat lattice, which takes advantage of the 1/M3 scaling of the emittance with respect to the number of dipoles M. In order to ensure that our facility remains competitive, APS is pursuing a major upgrade, which involves replacement of the existing double-bend lattice with a seven-bend achromat lattice, promising a 40-fold reduction in emittance. This paper describes the process of developing and evaluating candidate lattice designs. Two candidate 6-GeV lattices are described: one providing a natural emittance of 67 pm and the other providing 41 pm. Our analysis includes single-particle dynamics as well as single- and multi-bunch collective effects.

07 ISOTOPE AND RADIATION SOURCES↗

Digital front-end electronics for a tagged neutron inspection system

In this paper, we shall present a simple VME front-end system that employs the FADC CAEN V1720 8- channel 12-bit 250-MS/s digitizer. This system produces coincidence spectra between the trigger particle and other detectors and it replaces the traditional technique of chaining analog electronics. Tests have been performed using a pulser working at different frequencies as well as employing a {sup 252}Cf source in concert with an array of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collimators and beam dumps for the APS-upgrade storage ring - 25478

Argonne's Advanced Photon Source is planning a major upgrade that will increase the storage ring current from the present 100 mA to 200 mA and decrease the beam lifetime due to high charge-per-bunch and substantially smaller transverse beam size. Collimators in the horizontal plane around the storage ring will be used to control beam losses. These collimators will also serve as whole beam dumps in cases where the stored beam must be dumped for machine protection. Another feature of the Upgrade is swap-out injection, in which a stored electron bunch will be extracted to a dedicated swap-out dump when its charge falls to about 90% of the initial value and immediately replaced with a new bunch. Since particle losses will be concentrated in these collimators and beam dumps, there is the potential for high dose rates around these locations and for activation of nearby accelerator components. This paper contains a brief summary of the APS Upgrade, discusses electron losses in the storage ring, and presents calculations of dose rates and induced activity around the collimators and beam dumps. (authors)

43 PARTICLE ACCELERATORS↗

Deciding Between an X-Ray and 137Cs Irradiator – It’s Not Just About Energy Spectra

Irradiators utilizing radioactive cesium-137 or cobalt-60 have been used for medical applications for many decades. This includes the irradiation of much of the nation’s blood supply, and radiation biology research. In 2005, the U.S. Nuclear Regulatory Commission was assigned to evaluate and prevent the misuse of radioactive materials with malicious intentions, with gamma-ray sources being high on the list. Licensees who possessed higher quantities of radioactive material of concern were required to set up increased security controls such as constant surveillance, controlled access, personnel background checks, and other security controls. As a result of introducing such regulations, and problems with disposing of high activity sources, many users of gamma-ray sources started to look into alternative technologies to replace their gamma-ray irradiators – the main alternative being an X-ray irradiator. To make an educated decision on whether a particular type of X-ray irradiator is equivalent to a particular type of cesium-137 irradiator for specific applications, one has to rely on relevant published comparison studies from other researchers, or perform the comparison studies on their own. This publication focuses on the authors’ technical performance comparison of two cesium-137 irradiator models and two X-ray irradiator models, for the purpose of determining whether the X-ray irradiator models could validly replace the cesium-137 irradiator models for certain applications. Utilizing 47 gram and 120 gram tissue-equivalent rodent dosimetry phantoms, our results indicate that, depending upon the user’s dose uncertainty budget and maximum size of specimens to be irradiated, the Model RS2000 160 kVp X-ray irradiator, Model XRAD-160 X-ray irradiator, or Model XRAD-320 X-ray irradiator, could successfully replace a cesium-137 irradiator. It is expected such equivalency could be extrapolated to other irradiated specimens of known sizes and density. Results also reveal that differences in inherent source geometry, field geometry and irradiation geometry can counter some of the influence due to differences in energy spectrum. It is hoped that this publication can be used as a guide for other similar studies, providing investigators guidance on important details that can make the difference between strong and weak comparison conclusions.

Cs-137 irradiator, X-ray Irradiator, self-containe↗

OCEANFILMS (Organic Compounds from Ecosystems to Aerosols: Natural Films and Interfaces via Langmuir Molecular Surfactants) sea spray organic aerosol emissions – implementation in a global climate model and impacts on clouds

Sea spray aerosol is one of the major sources of atmospheric particulate matter globally. It has increasingly been recognized that organic matter derived from ocean biological precursors contributes significantly to the composition of submicron sea spray and may modify sea spray aerosol impacts on clouds and climate. This paper describes the implementation of the OCEANFILMS (Organic Compounds from Ecosystems to Aerosols: Natural Films and Interfaces via Langmuir Molecular Surfactants) parameterization for sea spray organic aerosol emissions in a global Earth system model, the Energy Exascale Earth System Model (E3SM). OCEANFILMS is a physically based model that links sea spray chemistry with ocean biogeochemistry using a Langmuir partitioning approach. We describe the implementation details of OCEANFILMS within E3SM, compare simulated aerosol fields with observations, and investigate impacts on simulated clouds and climate. Four sensitivity cases are tested, in which organic emissions either strictly add to or strictly replace sea salt emissions (in mass and number) and are either fully internally or fully externally mixed with sea salt. The simulation with internally mixed, added organics agrees reasonably well with observed seasonal cycles of organic matter in marine aerosol and has been selected as the default configuration of the E3SM. In this configuration, sea spray organic aerosol contributes an additional source of cloud condensation nuclei, adding up to 30 cm -3 to Southern Ocean boundary-layer cloud condensation nuclei concentrations (supersaturation = 0.1 %). The addition of this new aerosol source strengthens shortwave radiative cooling by clouds by -0.36 W m -2 in the global annual mean and contributes more than -3.5 W m -2 to summertime zonal mean cloud forcing in the Southern Ocean, with maximum zonal mean impacts of about -4 W m -2 around 50–60°S. This is consistent with a previous top-down, satellite-based empirical estimate of the radiative forcing by sea spray organic aerosol over the Southern Ocean. Through its mechanistic approach, OCEANFILMS offers a path towards improved understanding of the feedbacks between ocean biology, sea spray organic matter, and climate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and development of equi-atomic refractory High Entropy Alloys for use in radiation environments

Development of new structural materials that can withstand the extreme environments of nuclear reactors where the materials are exposed to high dose rate of ~ 30 200 dpa, high temperatures of the order of 500 1000 o C and tens of years of operation is vital for exploiting the “smallest carbon footprint energy source” to its fullest, in order to deal with the energy crisis worldwide. Recently, HEAs have shown superior irradiation properties over conventional alloys like higher resistance to defect formation, lower void swelling, limited irradiation hardening and higher microstructural stability under irradiation, making them potential structural material candidates for reactors. Proper characterization and testing of these materials are essential before they can replace the conventional alloys.

36 MATERIALS SCIENCE↗

First Generation Final Focusing Solenoid For NDCX-I

This report describes the prototype final focus solenoid (FFS-1G), or 1st generation FFS. In order to limit eddy currents, the solenoid winding consists of Litz wire wound on a non-conductive G-10 tube. For the same reason, the winding pack was inserted into an electrically insulating, but thermally conducting Polypropylene (Cool- Poly© D1202) housing and potted with highly viscous epoxy (to be able to wick the single strands of the Litz wire). The magnet is forced-air cooled through cooling channels. The magnet was designed for water cooling, but he cooling jacket cracked, and therefore cooling (beyond natural conduction and radiation) was exclusively by forced air. Though the design operating point was 8 Tesla, for the majority of running on NDCX-1 it operated up to about 5 Tesla. This was due mostly from limitations of voltage holding at the leads, where discharges at higher pulsed current damaged the leads. Generation 1 was replaced by the 2nd generation solenoid (FFS-2G) about a year later, which has operated reliably up to 8 Tesla, with a better lead design and utilizes water cooling. At this point, FFS-1G was used for plasma source R&D by LBNL and PPPL. The maximum field for those experiments was reduced to 3 Tesla due to continued difficulty with the leads and because higher field was not essential for those experiments. The pulser for the final focusing solenoid is a SCR-switched capacitor bank which produces a half-sine current waveform. The pulse width is ~800us and a charge voltage of 3kV drives ~20kA through the magnet producing ~8T field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aeroacoustic diffraction and dissipation by a short propeller cowl in subsonic flight

This report develops and applies an aeroacoustic diffraction theory for a duct, or cowl, placed around modelled sources of propeller noise. The regime of flight speed is high subsonic. The modelled cowl's inner wall contains a liner with axially variable properties. Its exterior is rigid. The analysis replaces both sides with an unsteady lifting surface coupled to a dynamic thickness problem. The resulting pair of aeroacoustic governing equations for a lined 'ring wing' is valid both for a passive and for an active liner. Their numerical solution yields the effective dipole and monopole distributions of the shrouding system and thereby determines the cowl-diffracted component of the total radiated field. The sample calculations here include a preliminary parametric search for that liner layout which maximizes the cowl's shielding effectiveness. The main conclusion of the study is that a short cowl, passively lined, should provide moderate reductions in propeller noise.

Martinez, Rudolph↗

Targeting mitochondria in cancer cells using gold nanoparticle-enhanced radiotherapy: A Monte Carlo study

Purpose: Radiation damage to mitochondria has been shown to alter cellular processes and even lead to apoptosis. Gold nanoparticles (AuNPs) may be used to enhance these effects in scenarios where they collect on the outer membranes of mitochondria. A Monte Carlo (MC) approach is used to estimate mitochondrial dose enhancement under a variety of conditions. Methods: The PENELOPE MC code was used to generate dose distributions resulting from photons striking a 13 nm diameter AuNP with various thicknesses of water-equivalent coatings. Similar dose distributions were generated with the AuNP replaced by water so as to estimate the gain in dose on a microscopic scale due to the presence of AuNPs within an irradiated volume. Models of mitochondria with AuNPs affixed to their outer membrane were then generated—considering variation in mitochondrial size and shape, number of affixed AuNPs, and AuNP coating thickness—and exposed (in a dose calculation sense) to source spectra ranging from 6 MV to 90 kVp. Subsequently dose enhancement ratios (DERs), or the dose with the AuNPs present to that for no AuNPs, for the entire mitochondrion and its components were tallied under these scenarios. Results: For a representative case of a 1000 nm diameter mitochondrion affixed with 565 AuNPs, each with a 13 nm thick coating, the mean DER over the whole organelle ranged from roughly 1.1 to 1.6 for the kilovoltage sources, but was generally less than 1.01 for the megavoltage sources. The outer membrane DERs remained less than 1.01 for the megavoltage sources, but rose to 2.3 for 90 kVp. The voxel maximum DER values were as high as 8.2 for the 90 kVp source and increased further when the particles clustered together. The DER exhibited dependence on the mitochondrion dimensions, number of AuNPs, and the AuNP coating thickness. Conclusions: Substantial dose enhancement directly to the mitochondria can be achieved under the conditions modeled. If the mitochondrion dose can be directly enhanced, as these simulations show, this work suggests the potential for both a tool to study the role of mitochondria in cellular response to radiation and a novel avenue for radiation therapy in that the mitochondria may be targeted, rather than the nuclear DNA.

60 APPLIED LIFE SCIENCES↗

Beyond Californium—A Neutron Generator Alternative for Dosimetry and Instrument Calibration in the U.S.

Many evaluations of neutron survey instruments, area monitors and personal dosimeters rely on neutron reference radiations from 252Cf, a source of spontaneous fission neutrons that produces high dose rates from an almost point source geometry. Its characteristics are generally more favorable when compared to (a,n), photoneutron and reactor-based sources of neutrons. The source is typically used in two standardized configurations: unmoderated, to yield a fission energy spectrum, or placed within a heavy-water moderating sphere to produce a softened spectrum that is more appropriate for evaluating devices used in nuclear power plant work environments. The U.S. Department of Energy (DOE) 252Cf Loan/Lease Program was terminated in 2009, and the replacement of high-activity sources is increasingly cost prohibitive for laboratories that formerly benefited from that program, including the Pacific Northwest National Laboratory (PNNL) and National Institute of Standards and Technology (NIST). Neutron generators, based on the D-T and D-D fusion reactions, are becoming economically competitive with 252Cf and are recognized internationally as important calibration and test standards. Researchers from NIST and PNNLare jointly considering the practicality and technical challenges of implementing neutron generators as calibration standards in the U.S. This article reviews characteristics of isotope-based sources, leading to rationale behind increasing favor of electronically-generated neutron options. The evaluation of a D-T system at PNNL has revealed primary challenges in adapting generators to the task of calibration and testing in which neutron characteristics must be accurately determined. Concepts for modifying the generated neutron spectra to achieve particular targeted spectra, simulating 252Cf or workplace environments, are discussed.

Calibration, californium-252, Dosimeter Irradiatio↗

Recent Progress on the PNL Accelerator-Based Intense Fusion Neutron Source

Phoenix Nuclear Labs (PNL) has developed a full line of accelerator-based neutron generators. This paper describes the highest yield DD fusion-based system. This device utilizes a microwave ion source (MWS), 300 kV DC accelerator, magnetic solenoid focus element, differential pumping system, and gaseous deuterium target to achieve DD neutron yields of 3x10{sup 11} n/s. Lower-yield variations of the device have been built using variable voltages and a solid titanium target, and design for a DT version of the gas target system is underway that will increase neutron yield to 5x10{sup 13} n/s. PNL has delivered a number of systems to government and commercial customers and has identified a number of longer-term commercial applications for this high-yield neutron generator. These include medical isotope production, neutron radiography, active interrogation for explosives and SNM detection, and Cf-252 replacement. Most applications require the development of specialized moderator assemblies and fixtures to meet customer requirements. A photograph of the neutron generator prototype is provided in Figure 1. This state-of-the-art neutron generator technology is essential for many applications of critical global importance including neutron radiography, medical isotope production, detection of explosives and nuclear material, materials characterization, and others. The presentation will discuss these applications and recent progress made on the base accelerator technology. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Dosimetry in Thermal Neutron Irradiation Facility at BMRR

Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D 2 O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7 % lower than the statistical mean derived from the Monte-Carlo modeling (5% uncertainty). The dose rate measured by ion chambers was 6 - 10 % lower than the output tallies (7% uncertainty). The detailed dosimetry that was performed at the TNIF for the NCT will be described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New precise half-life measurement for the superallowed β+ emitter Ar34

We have measured the half-life of 34 Ar, the parent of a superallowed 0 + → 0 + β transition, to be 0.84646(35) s. With a precision of 0.04%, this result is an essential ingredient needed to complete a third pair of mirror superallowed transitions, 34 Ar → 34 Cl and 34 Cl → 34 S, the ratio of whose ft values would provide the most sensitive test yet of the isospin-symmetry-breaking corrections used to obtain V ud . In a sequence repeated thousands of times, we implanted a very pure 34 Ar beam into tape for 0.7 s, and then rapidly transported the collected source to a shielded 4π proportional gas counter, which detected the decay positrons from the combined decays of 34 Ar and its daughter 34 Cl. The data were analyzed as a linked parent-daughter pair. Our new result replaces one we published 13 years ago.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Progress on the Stochastic Objective Decision Aide (SODA) Application

Idaho State University, in collaboration with Idaho National Laboratory, is engaged in development of a simple to use software application that utilizes stochastic techniques for the calculation of radiation doses associated with hypothetical radioactive material releases. This work is being performed through a grant from the U.S. Department of Energy (DOE) Nuclear Safety Research and Development (NSR and D) Program. Initial progress on the application was reported previously. Recent additions to the application are reported here. The Stochastic Objective Decision Aide (SODA) provides an easy to use software application to help decision makers support their judgment about the need or lack of need for safety structures, systems, and components. SODA is not intended to replace traditional design basis accident dose calculation methodology, nor is it intended to replace existing software used to perform formal dose consequence calculations. Rather, SODA is intended to supplement information obtained from existing codes to give a decision maker more information about an accident scenario. SODA also provides a simple method to perform parametric or sensitivity studies on individual input parameters. Non-reactor nuclear facilities operated under the approval authority of the US DOE use unmitigated hazard evaluations to determine if potential radiological doses associated with design basis events challenge dose evaluation guidelines. Unmitigated events that sufficiently challenge dose evaluation guidelines merit the selection of safety structures, systems, or components (SSCs) to prevent or mitigate the hazard. Dose consequence calculations traditionally involve use of the 'five-factor' formula: ST = MAR.DR.ARF.RF.LPF where ST is the source term (Bq), MAR is the total available material-at-risk (Bq), DR is the damage ratio (no units), ARF is the airborne release fraction (no units), RF is the respirable fraction (no units), and LPF is the leak path factor (no units). Potential radiation doses are then calculated using: CED = χ/Q.BR.ST.DCF (2) where CED is the committed effective dose (Sv), χ/Q is the plume dispersion (s/m{sup 3}), BR is the breathing rate (m{sup 3}/s), ST is the source term (Bq), and DCF is the dose conversion factor (Sv/Bq). Conservative single value input parameters are typically used to represent ARF, RF, LPF and BR. The traditional methodology, while conservative, can lead to skewed conclusions in the balance between cost and risk reduction resulting in over engineered systems with greater design, construction and operating costs. Rather than using a bounding single point value for each parameter in the dose consequence calculation, SODA uses distributions for some or all of the parameters. Each input parameter distribution is stochastically sampled and the resulting dose consequence calculation is repeated many times to develop a dose consequence distribution. The resulting distribution provides more information for the decision maker to rely upon when determining the need for safety SSCs. The SODA application was developed using MATLAB and it incorporates the use of Monte Carlo techniques as well as a graphical user interface (GUI). The application includes user selection of the governing distribution for parameters such as the MAR, DR, ARF, RF, LPF,χ/Q, BR, and DCF. While MATLAB was used for the development work, the application is distributed as a self-contained executable program. Features of the application include pull down menus with available distributions for the various parameters. The user has the option to plot the input parameter distribution that results from the random sampling process. The resulting dose consequence distribution is automatically analyzed to determine its similarity to well know distributions. This was done using the Bayesian Information Criterion method. If the resulting distribution is sufficiently similar to a well-known distribution, the application provides information about the distributions such as the mean value and other parameters. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗