Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF waves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Implementation of Ion Mobility Spectrometry-Based Separations in Structures for Lossless Ion Manipulations (SLIM)

Structures for Lossless Ion Manipulations (SLIM) is a powerful variant of traveling wave ion mobility spectrometry (TW-IMS) that uses a serpentine pattern of microelectrodes deposited onto printed circuit boards to achieve ultralong ion path lengths (13.5 m). Ions are propelled through SLIM platforms via arrays of TW electrodes while RF and DC electrodes provide radial confinement, establishing near lossless transmission. The recent ability to cycle ions multiple times through a SLIM has allowed ion path lengths to exceed 1000 m, providing unprecedented separation power and the ability to observe ion structural conformations unobtainable with other IMS technologies. The combination of high separation power, high signal intensity, and the ability to couple with mass spectrometry places SLIM in the unique position of being able to address longstanding proteomics and metabolomics challenges by allowing the characterization of isomeric mixtures containing low abundance analytes.

Hollerbach, Adam L.↗

Quantum-Enhanced Dark-Matter Sensing with Large Photon Number Fock States in a High-Q SRF Cavity

Wave-like dark matter candidates such as axions or dark photons in the microwave frequency range can be probed using resonant superconducting cavities. We demonstrate a quantum-enhanced sensing approach based on a multimode, high-Q superconducting RF (SRF) cavity, where a large Fock state is prepared in the storage mode via sideband transitions mediated by a transmon ancilla and a measurement-based feedforward protocol, achieving high-fidelity Fock states [1]. The prepared |n⟩ state induces stimulated emission from the dark-matter field, providing an (n + 1) enhancement in transition probability and proportional boost in signal rate [2]. A secondary cavity mode functions as an in-situ reference to calibrate noise. We present the control sequence, noise-referencing strategy, and projected sensitivity improvements for axion and dark-photon detection. This multimode architecture combines large Fock state preparation with noise calibration, offering a practical path to increased scan rate in cavity-based dark-matter searches.

Kim, Taeyoon↗

Development of a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, the RF design process of 0.5~1 meter scale TW cavity was begun at Fermilab for advancing TW technologies necessary more for future accelerator-scale one. Considering the physical dimensions of existing SRF facilities (for fabrication, processing, and cryogenic testing) and the lessons learned from the 3-cell, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Here we report a preliminary RF design, development plans, and activities.

43 PARTICLE ACCELERATORS↗

Mock-Up Waveguide Loop Development toward a Half-Meter Scale Traveling-Wave SRF Cavity

Mock-up waveguide loop development toward a half-meter scale traveling-wave SRF cavity ABSTRACT = Traveling-Wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The success of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium encouraged to advance TW technologies necessary more for future accelerator-scale one. Fermilab has proposed a preliminary RF design of a half-meter scale TW cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new TW excitation and control schemes such as, double directional coupler and two WG tuners. Mock-up waveguide loop development was launched under Fermilab LDRD program to demonstrate those new RF schemes at a room temperature. Fabrication drawings of a mock-up loop were completed. More details and plans of the development will be presented.

Furuta, Fumio [Fermilab]↗

Mock-up Waveguide Loop Development toward a half-meter scale Traveling-Wave (TW) SRF cavity

Traveling-Wave (TW) technology can push the accelera-tor field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The success of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium encouraged to advance TW technologies necessary more for future accelerator-scale one. Fermilab has proposed a preliminary RF design of a half-meter scale TW cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell. It consists of a 7-cell structure and a power feed-back waveguide (WG) loop with new TW excitation and control schemes such as, double directional coupler and two WG tuners. Mock-up waveguide loop development was launched under Fermilab LDRD program to demon-strate those new RF schemes at a room temperature. Fab-rication drawings of a mock-up loop were completed. Here details and plans of the development are reported.

Furuta, F. [Fermilab] (ORCID:0009000072218576)↗

Design of Stand-Alone Cryomodule based on Superconducting Quarter-Wave Resonator

Present superconducting accelerators require a central refrigeration system and piping to distribute liquid helium and nitrogen. Stand-alone cryocooler-based systems are of significant interest both to scientific and industrial customers, as they allow applications at facilities where no cryogenic equipment and expertise exists, where it is undesirable to develop additional cryogenic systems, or where a mobile system that can be transported between beamlines or facilities is required. The technical challenge of this approach is to minimize the heat losses to the liquid helium so that commercially available, self-contained cryocoolers are able to handle the thermal load. This paper presents an improved design for a stand-alone quarter-wave resonator (QWR) cryomodule a based on commercially available cryocoolers. This cryomodule has a particular application in the ATLAS intensity upgrade project where it will house a 72.75 MHz QWR for beam energy adjustments to experimental areas, where no helium cryogenic systems exist. The described cryomodule may also be the critical part of a turnkey system with application to material processing, semiconductor manufacturing, food irradiation and homeland security. The development of low heat loss peripheral components reduces cost and widens applicability of the system. We will discuss the cryomodule and RF coupler designs, including numerical thermal and structural analyses.

43 PARTICLE ACCELERATORS↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

This document describes the development of a field programable gate array (FPGA) radio frequency system on a chip (RF SoC) adaptation and evaluation of the single-board device to perform both Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR) for offline and online cable testing. The work builds on and leverages the work of Pacific Northwest National Laboratory (PNNL) in airport millimeter wave technology by using the same development hardware employed in that program. The work is performed under sponsorship from the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program and the task objective is to confirm and demonstrate feasibility to adapt FPGA technology for a cost-effective multiplexed single-board electronic module to perform cable tests that are equivalent to commercial and laboratory test instruments for FDR and SSTDR cable tests. The developed 2-channel (extendable to 7 channels) system was compared to dedicated and proven test instruments and shown to produce equivalent results on a range of cables and with a range of damage types. The FPGA reflectometry test board is one of several technologies that could facilitate implementation of online monitoring of safety critical cable systems.

42 ENGINEERING↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

A new cw-NMR Q-meter for dynamically polarized targets for particle physics

Polarized solid targets produced via Dynamic Nuclear Polarization rely on Continuous-Wave Nuclear Magnetism Resonance measurements to accurately determine the degree of polarization of bulk samples polarized to nearly 100%. Since the late 1970's phase sensitive detection methods have been utilized to observe the magnetization of a sample as a small change in inductance under RF excitation near the Larmor frequency of the nuclear species of interest, using a device known as a Q-meter. Liverpool Q-meters, produced in the UK in the 80's and 90's, have been the workhorse devices for these targets for decades, however their age and scarcity has meant new systems are needed. In conclusion, we describe a Q-meter system designed and built at Jefferson Lab in the Liverpool style to have comparable electronic performance with several improvements to update and adapt the devices for modern use.

Dynamic nuclear polarization↗

Electromagnetic and Engineering Design of a High-Current 15-MeV/u Cyclotron

The capability to produce high current, low loss, and extracted external ion beams presents an enabling technology for nuclear security, isotope production, and medical applications. We report on a novel, continuous-wave cyclotron for accelerating light ions with a charge-to-mass ratio of 1/2, which is designed for 1 mA maximum and 15 MeV/u energy. This article details the conceptual electromagnetic (EM) and engineering design including the 1.1 T sector magnets and 45 MHz, 200 kV radio frequency (RF) cavities. We discuss the cyclotron beam parameters with respect to potential commercial and industrial applications. The general concept and the accelerator’s layout are followed by a detailed EM design of magnets and RF cavities. Finally, practical engineering design considerations will be provided.

07 ISOTOPE AND RADIATION SOURCES↗

Capture Cavities for the CW Polarized Positron Source Ce+BAF

The initial design of the capture cavities for a continuous wave (CW) polarized positron beam for the Continuous Electron Beam Accelerator Facility (CEBAF) up-grade at Jefferson Lab is presented. A chain of standing wave multi-cell copper cavities inside a solenoid channel are selected to capture positrons in CW mode. The cavity shunt impedance is surveyed by tuning the cavity geometry while considering accommodating large phase space distribution positron beams with large beam pipe radius while ensuring a large enough passband mode separation. The RF field wall loss power and maximum wall loss power density are considered in cavity and waveguide design. A range of design parameters are given for larger system optimization when the capture cavities are considered together with thermal calculation and beam dynamics in next phase of work.

Wang, S.↗

A fiber-coupled dispersion interferometer for density measurements of pulsed power transmission line electron sheaths on Sandia’s Z machine

A fiber-coupled Dispersion Interferometer (DI) is being developed to measure the electron density of plasmas formed in power flow regions, such as magnetically insulated transmission lines, on Sandia National Laboratories (SNL’s) Z machine [D. B. Sinars et al., Phys. Plasmas 27, 070501 (2020)]. The diagnostic operates using a fiber-coupled 1550 nm CW laser with frequency-doubling to 775 nm. The DI is expected to be capable of line-average density measurements between ∼1013 and 1019 cm−2. Initial testing has been performed on a well-characterized RF lab plasma [A. G. Lynn et al., Rev. Sci. Instrum. 80, 103501 (2009)] at the University of New Mexico to quantify the density resolution lower limits of the DI. Initial testing of the DI has demonstrated line-average electron density measurements within 9% of results acquired via a 94 GHz mm wave interferometer for line densities of ∼1 × 1014 cm−2, despite significant differences in probe beam geometries. The instrument will next be utilized for measurements on a ∼1 MA-scale pulsed power driver {MYKONOS [N. Bennett et al., Phys. Rev. Accel. Beams 22, 120401 (2019)] at SNL} before finally being deployed on SNL’s Z machine. The close electrode spacing (mm scale) on Z requires probe beam sizes of ∼1 mm, which can only be obtained with visible or near infrared optical systems, as opposed to longer wavelength mm wave systems that would normally be chosen for this range of density.

Hines, N. R. (ORCID:0000000315316465)↗

Design and Principles of Linear Accelerators and Colliders." in Particle Physics Reference Library, pp. 295-336. Springer, Cham, 2020.

Linear accelerators (linacs) use alternating radiofrequency (RF) electromagnetic fields to accelerate charged particles in a straight line. Linacs were invented about 95 years ago and have seen many significant technical innovations since. A wide range of particle beams have been accelerated with linacs including beams of electrons, positrons, protons, antiprotons, and heavy ions. Linac parameter possibilities include pulsed versus continuous wave, low and high beam powers, low and high repetition rates, low transverse emittance beams, short bunches with small energy spreads, and accelerated multiple bunches in a single pulse. The number of linacs around the world has grown tremendously with thousands of linacs in present use, many for medical therapy, in industry, and for research and development in a broad spectrum of scientific fields. Researchers have developed accelerators for scientific tools in their own right, being awarded several Nobel prizes. Moreover, linacs and particle accelerators in general have enabled many discovery level science experiments in related fields, resulting in many Nobel prizes as well.

Seeman, John↗

First High-Gradient Results of UED/UEM SRF Gun at Cryogenic Temperatures

Benefiting from the rapid progress on RF photogun technologies in the past two decades, the development of MeV range ultrafast electron diffraction/microscopy (UED and UEM) has been identified as an enabling instrumentation. UEM or UED use low power electron beams with modest energies of a few MeV to study ultrafast phenomena in a variety of novel and exotic materials. SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb₃Sn and conduction cooling. The use of Nb₃Sn allows to operate SRF cavities at higher temperatures (4K) with low power dissipation which is within the reach of commercially available closed-cycle cryocoolers. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. In this paper, we present first high gradient results of the gun conducted in liquid helium.

43 PARTICLE ACCELERATORS↗

Application of Superconducting Cavities as Ultra-Sensitive RF Photon Detectors

Superconducting radio frequency (SRF) cavities are the world’s most efficient engineered oscillators, and they have long been employed for extremely high efficiency transfer of energy to beams of charged particles. Decades of R&D for particle accelerators have led to modern treatments for SRF cavities that achieve higher performance than was previously possible. Advanced SRF cavities using particle accelerator technology are now being used to search for new physics, including dark matter and gravitational waves. The extremely high Q makes it possible to search for very small signals from photons in the radio frequency range, and the extremely high electric fields makes it possible to perform experiments that involve pumping one mode of a cavity in order to search for power transfer mediated by new physics. This talk will present novel experiments that employ SRF cavities, including searches for axions and dark photons dark matter, light-shining-through-walls, and high frequency gravitational waves. Results to be presented include searches with world record sensitivity.

43 PARTICLE ACCELERATORS↗

Development of a Traveling-Wave (TW) SRF cavity

Traveling-wave technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the fundamental limit of 50~60MV/m in Standing-Wave regime. The 1st demonstration of TW resonance excitation in a proof-of-principle 3-cell SRF cavity in 2K liquid helium was successfully carried out at Fermilab in collaboration with Euclid Techlabs. In parallel with that, to advancing TW technologies necessary more for future accelerator-scale one, Fermilab has proposed a preliminary RF design of a half-meter scale TW SRF cavity by considering the physical dimensions of existing SRF facilities and the lessons learned from the 3-cell,. It consists of a 7-cell structure and a power feedback waveguide (WG) loop with new RF configurations to control TW resonance. Development efforts toward a TW 7-cell has been in progress. Here we report the recent activities and progresses of those.

Furuta, F.↗