Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RETENTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Retention of ion-implemented-xenon in olivine - Dependence on implantation dose

The diffusion of Xe in olivine, a major mineral in both meteorites and linear samples, was studied. Xe ions were implanted at 200 keV into single-crystal synthetic-forsterite targets and the depth profiles were measured by alpha particle backscattering before and after annealing for 1 hour at temperatures up to 1500 C. The fraction of implanted XE retained following annealing was strongly dependent on the implantation dose. Maximum retention of 100 percent occurred for an implanting dose of 3 x 10 to the 15th power Xe ions/sq cm. Retention was less at lower doses, with approximately more than or = 50 percent loss at one hundred trillion Xe ions/sq cm. Taking the diffusion coefficient at this dose as a lower limit, the minimum activation energy necessary for Xe retention in a 10 micrometer layer for ten million years was calculated as a function of metamorphic temperature. Previously announced in STAR as N83-18528

Melcher, C. L.↗

Large-scale Advanced Prop-fan (LAP) hub/blade retention design report

The Large-scale Advanced Prop-fan (LAP) hub assembly forms a semi-rigid link between the blades, which provide the thrust, and the engine shaft, which provides the torque. The hub and tailshaft is a one piece partially forged part which is carburized, heat treated and machined. A single row ball bearing restrains each of the eight blades in the hub, while the tailshaft secures the propeller to the engine shaft with two cone seats that are preloaded against each other by the Prop-fan retaining nut. The hub also forms the support for the pitch change actuator system, the control and the spinner. The retention transmits the loads from the blades to the hub while allowing the changes in blade pitch. The single row ball bearing retention provides ease of maintenance by allowing individual blade replacement without dissassembly of the hub. It has a through hardened inner race which seats against the aluminum blade shank and an outer race which is integral with the barrel. The outer race area is carburized to achieve the hardness necessary to support the ball loads. The balls are kept from contact with each other by a separator. The rotational speed of the propeller keeps the retention submerged in the oil which is contained in the hub by a seal. Stress and strain analysis, material hardness requirements, weight predictions, and stiffness characteristics are discussed.

Soule, Matthew↗

Evaluation of Data Retention Characteristics for Ferroelectric Random Access Memories (FRAMs)

Data retention and fatigue characteristics of 64 Kb lead zirconate titanate (PZT)-based Ferroelectric Random Access Memories (FRAMs) microcircuits manufactured by Ramtron were examined over temperature range from -85 C to +310 C for ceramic packaged parts and from -85 C to +175 C for plastic parts, during retention periods up to several thousand hours. Intrinsic failures, which were caused by a thermal degradation of the ferroelectric cells, occurred in ceramic parts after tens or hundreds hours of aging at temperatures above 200 C. The activation energy of the retention test failures was 1.05 eV and the extrapolated mean-time-to-failure (MTTF) at room temperature was estimated to be more than 280 years. Multiple write-read cycling (up to 3x10(exp 7)) during the fatigue testing of plastic and ceramic parts did not result in any parametric or functional failures. However, operational currents linearly decreased with the logarithm of number of cycles thus indicating fatigue process in PZT films. Plastic parts, that had more recent date code as compared to ceramic parts, appeared to be using die with improved process technology and showed significantly smaller changes in operational currents and data access times.

Sharma, Ashok K.↗

Evaluation of Data Retention and Imprint Characteristics of FRAMs Under Environmental Stresses for NASA Applications

A major reliability issue for all advanced nonvolatile memory (NVM) technology devices including FRAMs is the data retention characteristics over extended period of time, under environmental stresses and exposure to total ionizing dose (TID) radiation effects. For this testing, 256 Kb FRAMs in 28-pin plastic DIPS, rated for industrial grade temperature range of -40 C to +85 C, were procured. These are two-transistor, two-capacitor (2T-2C) design FRAMs. In addition to data retention characteristics, the parts were also evaluated for imprint failures, which are defined as the failure of cells to change from a "preferred" state, where it has been for a significant period of time to an opposite state (e.g., from 1 to 0, or 0 to 1). These 256 K FRAMs were subjected to scanning acoustic microscopy (C-SAM); 1,000 temperature cycles from -65 C to +150 C; high temperature aging at 150 C, 175 C, and 200 C for 1,000 hours; highly accelerated stress test (HAST) for 500 hours; 1,000 hours of operational life test at 125 C; and total ionizing dose radiation testing. As a preconditioning, 10 K read/write cycles were performed on all devices. Interim electrical measurements were performed throughout this characterization, including special imprint testing and final electrical testing. Some failures were observed during high temperature aging test at 200 C, during HAST testing, and during 1,000 hours of operational life at 125 C. The parts passed 10 Krad exposure, but began showing power supply current increases during the dose increment from 10 Krad to 30 Krad, and at 40 Krad severe data retention and parametric failures were observed. Failures from various environmental group testing are currently being analyzed.

Sharma, Asbok K.↗

Evaluation of Data Retention and Imprint Characteristics of FRAMs Under Environmental Stresses for NASA Applications

A major reliability issue for all advanced nonvolatile memory (NVM) technology devices including FRAMs (Ferroelectric random access memories) is the data retention characteristics over extended period of time, under environmental stresses and exposure to total ionizing dose (TID) radiation effects. For this testing, 256 Kb FRAMs in 28-pin plastic DIPS, rated for industrial grade temperature range of -40 C to +85 C, were procured. These are two-transistor, two-capacitor (2T-2C) design FRAMs. In addition to data retention characteristics, the parts were also evaluated for imprint failures, which are defined as the failure of cells to change from a "preferred" state, where it has been for a significant period of time to an opposite state (e.g., from 1 to 0, or 0 to 1). These 256 K FRAMs were subjected to scanning acoustic microscopy (C-SAM); 1,000 temperature cycles from -65 C to +150 C; high temperature aging at 150 C, 175 C, and 200 C for 1,000 hours; highly accelerated stress test (HAST) for 500 hours; 1,000 hours of operational life test at 125 C; and total ionizing dose radiation testing. As a preconditioning, 10 K read/write cycles were performed on all devices. Interim electrical measurements were performed throughout this characterization, including special imprint testing and final electrical testing. Some failures were observed during high temperature aging test at 200 C, during HAST testing, and during 1,000 hours of operational life at 125 C. The parts passed 10 Krad exposure, but began showing power supply current increases during the dose increment from 10 Krad to 30 Krad, and at 40 Krad severe data retention and parametric failures were observed. Failures from various environmental group testing are currently being analyzed.

Sharma, Ashok K.↗

Effects of Hydrocarbon-Based Grease on Rapid Prototype Material Used for Grease Retention Shrouds

Effects of hydrocarbon-based greases on specific rapid prototype (RP) materials used to fabricate grease retention shrouds (GRS) were explored in this study. Grease retention shrouds are being considered as a way to maintain adequate grease lubrication at the gear mesh in a prototype research transmission system. Due to their design and manufacturing flexibility, rapid prototype materials were chosen for the grease retention shrouds. In order to gain a better understanding of the short and long term effects grease pose on RP materials, research was conducted on the interaction of hydrocarbon-based grease with RP materials. The materials used in this study were durable polyamide (nylon), acrylonitrile butadiene styrene (ABS), and WaterClear 10120. Testing was conducted using Mobilgrease 28 and Syn-Tech 3913G grease (gear coupling grease). These greases were selected due to their regular use with mechanical components. To investigate the effect that grease has on RP materials, the following methods were used to obtain qualitative and quantitative data: Fourier transform infrared spectroscopy (FT-IR), interference profilometer measurements, digital camera imaging, physical shape measurement, and visual observations. To record the changes in the RP materials due to contact with the grease, data was taken before and after the grease application. Results showed that the WaterClear 10120 RP material provided the best resistance to grease penetration as compared to nylon and ABS RP materials. The manufacturing process, and thus resulting surface conditions of the RP material, played a key role in the grease penetration properties and resilience of these materials.

Zakrajsek, Andrew J.↗

Scoring Dawg Core Breakoff and Retention Mechanism

This novel core break-off and retention mechanism consists of a scoring dawg controlled by a set of two tubes (a drill tube and an inner tube). The drill tube and the inner tube have longitudinal concentric holes. The solution can be implemented in an eccentric tube configuration as well where the tubes have eccentric longitudinal holes. The inner tube presents at the bottom two control surfaces for controlling the orientation of the scoring dawg. The drill tube presents a sunk-in profile on the inside of the wall for housing the scoring dawg. The inner tube rotation relative to the drill tube actively controls the orientation of the scoring dawg and hence its penetration and retrieval from the core. The scoring dawg presents a shaft, two axially spaced arms, and a tooth. The two arms slide on the control surfaces of the inner tube. The tooth, when rotated, can penetrate or be extracted from the core. During drilling, the two tubes move together maintaining the scoring dawg completely outside the core. After the desired drilling depth has been reached the inner tube is rotated relative to the drill tube such that the tooth of the scoring dawg moves toward the central axis. By rotating the drill tube, the scoring dawg can score the core and so reduce its cross sectional area. The scoring dawg can also act as a stress concentrator for breaking the core in torsion or tension. After breaking the core, the scoring dawg can act as a core retention mechanism. For scoring, it requires the core to be attached to the rock. If the core is broken, the dawg can be used as a retention mechanism. The scoring dawg requires a hard-tip insert like tungsten carbide for scoring hard rocks. The relative rotation of the two tubes can be controlled manually or by an additional actuator. In the implemented design solution the bit rotation for scoring was in the same direction as the drilling. The device was tested for limestone cores and basalt cores. The torque required for breaking the 10-mm diameter limestone cores was 5 to 5.8 lb-in. (0.56 to 0.66 N-m).

Badescu, Mircea↗

Modeling of melt retention in EU-APR1400 ex-vessel core catcher

A core catcher is adopted in the EU-APR1400 reactor design for management and mitigation of severe accidents with reactor core melting. The core catcher concept incorporates a number of engineering solutions used in the catcher designs of European EPR and Russian WER-1000 reactors, such as thin-layer corium spreading for better cooling, retention of the melt in a water-cooled steel vessel, and use of sacrificial material (SM) to control the melt properties. SM is one of the key elements of the catcher design and its performance is critical for melt retention efficiency. This SM consists of oxide components, but the core catcher also includes sacrificial steel which reacts with the metal melt of the molten corium to reduce its temperature. The paper describes the required properties of SM. The melt retention capability of the core catcher can be confirmed by modeling the heat fluxes to the catcher vessel to show that it will not fail. The fulfillment of this requirement is demonstrated on the example of LBLOCA severe accident. Thermal and physicochemical interactions between the oxide and metal melts, interactions of the melts with SM, sacrificial steel and vessel, core catcher external cooling by water and release of non-condensable gases are modeled. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Estimation Technique of Cs Retention Fraction in Irradiated Nuclear Fuel with Intact/Damaged Form

Even in the case of severe accident such as in TMI-2 or Chernobyl-4 or Fukushima Dai-ichi nuclear power station, waste partitioning in the decommission process or special nuclear material (SNM) accountancy in molten core material is important. Though Cs-137 concentration information is used for burnup estimation in conventional spent nuclear fuels, it could not be applied for damaged nuclear fuel of severe accidents because of both a large release fraction of Cs and significant change of its shape and form by core melting. The ratio of {sup 134}Cs/{sup 137}Cs has often been used as an index of the burnup in the cleanup of TMI-2 and the Chernobyl Drum Assay System in Chernobyl-4 and other cleanup activities, assuming that the Cs isotope ratio inside the fuel matrix would be the same as in the fuel debris, whereas its retention fraction would vary. Cs retention fraction information would be very important for the reliability of the burnup estimation as well as for the severe accident safety analysis. In the present research, a principle of new technique to estimate the Cs retention fraction is proposed and examined by sensitivity analysis of the FP inventory in conventional BWR irradiated fuel numerically, and validated by comparing the past experimental data based on gamma spectrometry. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview of the US-Japan collaborative investigation on hydrogen isotope retention in neutron-irradiated and ion-damaged tungsten

Plasma-facing components (PFCs) will be exposed to 14 MeV neutrons from deuterium-tritium (D-T) fusion reactions, and tungsten, a candidate PFC for the divertor in ITER, is expected to receive a neutron dose of 0.7 displacement per atom (dpa) by the end of operation in ITER. The effect of neutron-irradiation damage has been mainly simulated using high-energy ion bombardment. While this prior database of results is quite valuable for understanding the behavior of hydrogen isotopes in PFCs, it does not encompass the full range of effects that must be considered in a practical fusion environment due to short penetration depth, damage gradient, high damage rate, and high PKA energy spectrum of the ion bombardment. In addition, neutrons change the elemental composition via transmutations, and create a high radiation environment inside PFCs, which influence the behavior of hydrogen isotope in PFCs, suggesting the utilization of fission reactors is necessary for neutron irradiation. Therefore, the effort to correlate among high-energy ions, fission neutrons, and fusion neutrons is crucial for accurately estimating tritium retention under a neutron-irradiation environment. Under the framework of the US-Japan TITAN program, tungsten samples (99.99 at. % purity from A.L.M.T. Co.) were irradiated by neutron in the High Flux Isotope Reactor (HFIR), ORNL, at 50 and 300C to 0.025, 0.3, and 1.2 dpa, and the investigation of deuterium retention in neutron-irradiation was performed in the INL Tritium Plasma Experiment (TPE), the unique high-flux linear plasma facility that can handle tritium, beryllium and activated materials. This paper reports the recent results from the comparison of ion-damaged tungsten via various ion species (2.8 MeV Fe2+, 20 MeV W2+, and 700 keV H-) with that from neutron-irradiated tungsten to identify the similarities and differences among them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radionuclide Retention Mechanisms in Secondary Waste-Form Testing: Phase II

This report describes the results from laboratory tests performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate candidate stabilization technologies that have the potential to successfully treat liquid secondary waste stream effluents produced by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). WRPS is considering the design and construction of a Solidification Treatment Unit (STU) for the Effluent Treatment Facility (ETF) at Hanford. The ETF, a multi-waste, treatment-and-storage unit that has been permitted under the Resource Conservation and Recovery Act (RCRA), can accept dangerous, low-level, and mixed wastewaters for treatment. The STU needs to be operational by 2018 to receive secondary liquid waste generated during operation of the WTP. The STU will provide the additional capacity needed for ETF to process the increased volume of secondary waste expected to be produced by WTP. This report on radionuclide retention mechanisms describes the testing and characterization results that improve understanding of radionuclide retention mechanisms, especially for pertechnetate, {sup 99}TcO{sub 4}{sup -} in four different waste forms: Cast Stone, DuraLith alkali aluminosilicate geopolymer, encapsulated fluidized bed steam reforming (FBSR) product, and Ceramicrete phosphate bonded ceramic. These data and results will be used to fill existing data gaps on the candidate technologies to support a decision-making process that will identify a subset of the candidate waste forms that are most promising and should undergo further performance testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The water retention curve and relative permeability for gas production from hydrate-bearing sediments: pore-network model simulation

Here, the water retention curve and relative permeability are critical to predict gas and water production from hydrate–bearing sediments. However, values for key parameters that characterize gas and water flows during hydrate dissociation have not been identified due to experimental challenges. This study utilizes the combined techniques of micro–focus X–ray computed tomography (CT) and pore–network model simulation to identify proper values for those key parameters, such as gas entry pressure, residual water saturation, and curve fitting values. Hydrates with various saturation and morphology are realized in the pore–network that was extracted from micron–resolution CT images of sediments recovered from the hydrate deposit at the Mallik site, and then the processes of gas invasion, hydrate dissociation, gas expansion, and gas and water permeability are simulated. Results show that greater hydrate saturation in sediments lead to higher gas entry pressure, higher residual water saturation, and steeper water retention curve. An increase in hydrate saturation decreases gas permeability but has marginal effects on water permeability in sediments with uniformly distributed hydrate. Hydrate morphology has more significant impacts than hydrate saturation on relative permeability. Sediments with heterogeneously distributed hydrate tend to result in lower residual water saturation and higher gas and water permeability. In this sense, the Brooks–Corey model that uses two fitting parameters individually for gas and water permeability properly capture the effect of hydrate saturation and morphology on gas and water flows in hydrate–bearing sediments.

58 GEOSCIENCES↗

Nanoscale retention-loss dynamics of polycrystalline PbTiO{sub 3} nanotubes.

We observed the nanoscale retention dynamics of polycrystalline PbTiO{sub 3} nanotubes using piezoresponse force microscopy. We found that the retention loss of the nanodot domains on the nanotubes showed the stretched exponential relaxation behaviors with stretched exponential factor n being less than 1 (0.523 and 0.692), which are similar to the thin films. In addition, the nanodot domains showed a diverse relaxation time constant {tau} due to different remnant polarization of each dot domains.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Retention of alkali ions by hydrated low-pH cements: Mechanism and Na{sup +}/K{sup +} selectivity

Low-pH cements, also referred to as low-alkalinity cements, can be designed by replacing significant amounts of Portland cement by pozzolanic materials. Their pore solution is characterized by a pH near 11, and an alkali concentration much lower than that of Portland cement. This work investigates the retention of sodium and potassium by a hydrated low-pH cement comprising 60% Portland cement and 40% silica fume. It is shown that sorption of potassium is higher than that of sodium and mainly results from counterion charge balancing of the C-S-H negative surface charge. To explain the greater retention of potassium compared to sodium, it is postulated that potassium, unlike sodium, may enter the interlayer of C-S-H to compensate the negative charges in the interlayer, in addition to the external surfaces. This assumption is supported by structural characterization of C-S-H using X-ray diffraction.

36 MATERIALS SCIENCE↗

The Impact of Acute Urinary Retention After Iodine-125 Prostate Brachytherapy on Health-Related Quality of Life

Purpose: To evaluate the impact of acute urinary retention (AUR) in patients treated with {sup 125}I prostate brachytherapy on short- and long-term health-related quality of life (HRQOL); and to assess whether pretreatment HRQOL has additional value in the prediction of AUR. Methods and Materials: For 127 patients treated with {sup 125}I brachytherapy for localized prostate cancer between December 2000 and June 2003, toxicity and HRQOL data were prospectively collected. Patients received a HRQOL questionnaire at five time points: before and 1 month, 6 months, 1 year, and 6 years after treatment. The questionnaire included the RAND-36 generic health survey, the cancer-specific European Organization for Research and Treatment of Cancer core questionnaire (EORTC QLQ-C30), the tumor-specific EORTC prostate cancer module (EORTC QLQ-PR25), and the American Urological Association (AUA) symptom index. Results: Of 127 patients, 13 (10.2%) developed AUR. Patients with AUR had a significantly worse urinary QOL at all time points compared with patients without AUR. The mean difference over time (6 years) between both groups for the EORTC QLQ-PR25 urinary symptom score was 13.0 points (p < 0.001) and for the AUA urinary symptom score was 15.7 points (p = 0.001). Global QOL scores (EORTC QLQ-C30) over time for patients who developed AUR were significantly worse compared with patients without AUR (mean difference 6.7 points; p = 0.043). In multivariate logistic regression analysis, pretreatment International Prostate Symptom Score (p = 0.004) and neoadjuvant hormonal treatment (p = 0.034) were predictors of AUR. Quality of life did not have added predictive value. Conclusion: Acute urinary retention after prostate brachytherapy has a significant negative impact on patient's HRQOL up to 6 years after treatment, in terms of both global QOL measures and urinary symptom scores. Furthermore, our results suggest limited value of pretreatment HRQOL measures for the prediction of AUR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Nanoimaging of Organic Charge Retention Effects: Implications for Nonvolatile Memory, Neuromorphic Computing, and High Dielectric Breakdown Devices

While a large variety of organic and molecular materials have been found to exhibit charge memory effects, the underlying mechanism is not well-understood, which hinders rational device design. Here, we study the charge retention mechanism of a nanoscale memory system, an organic monolayer on a silicon substrate, with Au nanoparticles on top serving as the electrical contact. Combining scanning probe imaging/manipulation and density functional simulations, we observe stable charge retention effects in the system and attributed it to polaron effects at the amine functional groups. Finally, our findings can pave the way for applications in nonvolatile memory, neuromorphic computing, and high dielectric breakdown devices.

36 MATERIALS SCIENCE↗

Quantifying data retention of perpendicular spin-transfer-torque magnetic random access memory chips using an effective thermal stability factor method

The thermal stability of perpendicular Spin-Transfer-Torque Magnetic Random Access Memory (STT-MRAM) devices is investigated at chip level. Experimental data are analyzed in the framework of the Néel-Brown model including distributions of the thermal stability factor Δ. We show that in the low error rate regime important for applications, the effect of distributions of Δ can be described by a single quantity, the effective thermal stability factor Δ{sub eff}, which encompasses both the median and the standard deviation of the distributions. Data retention of memory chips can be assessed accurately by measuring Δ{sub eff} as a function of device diameter and temperature. We apply this method to show that 54 nm devices based on our perpendicular STT-MRAM design meet our 10 year data retention target up to 120 °C.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗