Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESPIRATORY RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Spacelab Life Sciences flight experiments: an integrated approach to the study of cardiovascular deconditioning and orthostatic hypotension

The microgravity environment of spaceflight produces rapid cardiovascular changes which are adaptive and appropriate in that setting, but are associated with significant deconditioning and orthostatic hypotension on return to Earth's gravity. The rapidity with which these space flight induced changes appear and disappear provides an ideal model for studying the underlying pathophysiological mechanisms of deconditioning and orthostatic hypotension, regardless of etiology. Since significant deconditioning is seen after flights of very short duration, muscle atrophy due to inactivity plays, at most, a small role. These changes in circulatory control associated with cephalad fluid shifts, rather than inactivity per se, are probably more important factors. In order to test this hypothesis in a systematic way, a multidisciplinary approach which defines and integrates inputs and responses from a wide variety of circulatory sub-systems is required. The cardiovascular experiments selected for Spacelab Life Sciences flights 1 and 2 provide such an approach. Both human and animal models will be utilized. Pre- and post-flight characterization of the payload crew includes determination of maximal exercise capacity (bicycle ergometry), orthostatic tolerance (lower body negative pressure), alpha and beta adrenergic sensitivity (isoproterenol and phenylephrine infusions), baroreflex sensitivity (ECG-gated, stepwise changes in carotid artery transmural pressure with a pneumatic neck collar), and responses to a 24 h period of 5 deg head-down tilt. Measurements of cardiac output (CO2 and C2H2 rebreathing), cardiac chamber dimensions (phased-array 2-dimensional echocardiography), direct central venous pressure, leg volume (Thornton sock), limb blood flow and venous compliance (occlusion plethysmography), blood and plasma volumes, renal plasma flow and glomerular filtration rates, and various hormonal levels including catecholamines and atrial natriuretic factor will also be obtained. The central venous catheter will be inserted immediately pre-launch and monitored with heart rate and blood pressure in-flight until cardiac output, respiratory gas exchange and quantitative 2D echocardiography measurements can be performed. In-flight hemodynamic measurements will be repeated at rest and during submaximal exercise daily and also during maximal exercise midway through the flight to document the timecourse and extent of cardiovascular changes in the payload crew. Parallel studies are planned for the animals. In addition to measurements of right atrial and aortic pressures and cardiac output, a dorsal micro-circulatory chamber will allow determinations of changes in capillary and venular architecture and function in six of the rats. The techniques and findings from many of the SLS-1 and 2 supporting studies have already yielded significant information about circulatory regulation in patients with both hypo- and hypertension. The flight experiments themselves will provide new data to test the validity of both animal and human models currently used for simulating the fluid shifts of a micro-gravity environment. The development of effective countermeasures, not only for short and long duration space travellers, but also for Earth-bound medical patients can then be physiologically based on experimental data rather than anecdote.

Non-NASA Center↗

Threat Agnostic Virulence Assessment of Pathogens

Virulence assessment of new, emerging, and engineered pathogens is critical to mounting an appropriate response to a biothreat agent. The capacity of the pathogen to colonize human and harm tissues must be characterized to understand pathogenicity pathways and optimize diagnosis and treatment of resulting disease. Respiratory pathogens are of interest because they can have high transmissibility rates, as observed with the SARS-CoV-2 virus, the causative agent of Covid-19. Current technologies are insufficient to assess threats due to their reliance on systems with only one cell type and on sequencing the pathogen. However, it is known that sequence is not an accurate predictor of function, and sequencing can be unreliable for newly emerged or engineered pathogens. An ideal system would consist of relevant epithelial cell types and an assay sensitive enough to detect changes in host responses that do not rely on DNA sequencing. We chose a system consisting of host lung epithelial cells that can be used to assess the virulence of unknown respiratory pathogens. We interrogated pathogens using this model and assess features of pathogenicity. Our objective is to leverage PNNLs strengths in tissue engineering and proteomics capabilities to build a multiple reaction monitoring (MRM) or parallel reaction monitoring (PRM) liquid chromatography-tandem mass spectrometry assay for human host cell proteins whose abundance is influenced by infection. These responses can were then assessed for relative virulence using pathogen agnostic signatures. When confronted with a pathogen, cells activate dedicated signaling pathways, typically through phosphorylation of regulatory proteins and downstream activation of host cell networks.

59 BASIC BIOLOGICAL SCIENCES↗

Climatic factors and long-term trends of influenza-like illness rates in The Netherlands, 1970–2016

Highlights: • We studied the link between climatic factors and influenza-like illness (ILI) rate. • In the Netherlands, ILI rates dropped during 1970–2003, then started to rise again. • Weekly ILI count was inversely associated with humidity and temperature. • The early 2000s were a trend-reversal point for the climatic time series as well. • Seasonal average ILI rates and humidity (or temperature) were inversely correlated. Climatic factors affect the survival and transmissibility of respiratory viruses causing influenza-like illness (ILI), and we hypothesized that changes in absolute humidity and temperature may affect long-term trends of ILI incidence rate in temperate countries. We tested this hypothesis using ILI and meteorological time series in the Netherlands for the period 1970–2016.

54 ENVIRONMENTAL SCIENCES↗

Health impacts quantification of ambient air pollutants using AirQ model approach in Hamadan, Iran

Highlights: • AirQ model was used to evaluate health impacts of criteria air pollutants on the citizens of Hamadan. • Attributable proportion was estimated for cardiovascular and respiratory mortality. • Cardiovascular mortality has more contribution in total death number. • We provide for first time mortality data of Hamadan people relating to air pollution. • Negative linear correlations were observed between PM, including PM{sub 10}, PM{sub 2.5}, and wind speed. Iranian western cities, including Hamadan, have been experiencing Middle East Dust Storms (MEDS) phenomenon problems in recent years, so the air quality is getting worse every year in these cities. The aim of this study was to evaluate the human health impacts of criteria air pollutants including PM{sub 10}, PM{sub 2.5}, NO{sub 2}, SO{sub 2}, CO and O{sub 3} on the citizens of Hamadan using AirQ model software 2.2.3. Considering the determined baseline incidence (BI) and relative risk (RR) rate, the attributable proportion (AP) of deaths due to cardiovascular and respiratory mortality attributed to PM{sub 2.5}, PM{sub 10}, O{sub 3}, NO{sub 2}, and CO pollutants was estimated to be 4.42%, 3.37%, 1.75%, 1.74% and 0.92% (95% CI) of the total mortality and the excess death cases were respectively estimated to be 131.9, 100.4, 52.1, 51.9 and 27.3 persons. In addition, cardiovascular mortality brings more contribution than respiratory mortality in total death number. The results of our study also showed that PM{sub 2.5} poses the greatest health effects on the citizens. Analyzing the average seasonal concentrations of studied pollutants (PM{sub 10}, PM{sub 2.5}, and NO{sub 2}) and the mean seasonal temperature values revealed a positive linear correlation. Significant negative correlations were observed between the studied pollutants (PM{sub 10}, PM{sub 2.5} and NO{sub 2}) and relative humidity, and between PM and wind speed. This study, therefore, provides additional data in decision-makings for the development of strategies for reduction of ambient air pollution which will result in improvements of air quality.

54 ENVIRONMENTAL SCIENCES↗

SU-F-J-117: Impact of Motion Artifacts On Image Quality and Accuracy of Tumor Motion Reconstruction in 4D CT-On-Rails and MV-CBCT Scans: A Phantom Study

Purpose: To compare and quantify respiratory motion artifacts in images from free breathing 4D-CT-on-Rails(CTOR) and those from MV-Cone-beam-CT(MVCB) and facilitate respiratory motion guided radiation therapy. Methods: 4D-CTOR: Siemens Somatom CT-on-Rails system with Anzai belt loaded with pressure sensor load cells. 4D scans were performed in helical mode, pitch 0.1, gantry rotation time 0.5s, 1.5mm slice thickness, 120kVp, 400 mAs. Normal and fast breathing (>12rpm) scanning protocols were investigated. Helical scan, AIP(average intensity projection) and MIP(maximum intensity projection) were generated from 4D-CTOR scans with amplitude sorting into 10 phases.MVCB: Siemens Artiste diamond view(1MV)MVCB was performed with 5MU thorax protocol with 60 second of full rotation.Phantom: Anzai AZ-733V respiratory phantom. The settings were set to normal and resp. modes with repetition rates at 15 rpm and 10 rpm. Surgical clips, acrylic, wooden, rubber and lung density, total six mock-ups were scanned and compared in this study.Signal-to-noise ratio(SNR), contrast-to-noise ratio(CNR) and reconstructed motion volume were compared to different respiratory setups for the mock-ups. Results: Reconstructed motion volume was compared to the real object volume for the six test mock-ups. It shows that free breathing helical in all instances underestimates the object excursions largest to −67.4% and least −6.3%. Under normal breathing settings, MIP can predict very precise motion volume with minimum 0.4% and largest −13.9%. MVCB shows underestimate of the motion volume with −1.11% minimum and −18.0% maximum. With fast breathing, AIP provides bad representation of the object motion; however, the MIP can predict the motion volume with −2.0% to −11.4% underestimate. Conclusion: Respiratory motion guided radiation therapy requires good motion recording. This study shows that regular CTOR helical scans provides bad guidance, 4D CTOR AIP cannot represent the fast breathing pattern, MIP can represent the best motion volume, MVCBCT can only be used for normal breathing with acceptable uncertainties.

60 APPLIED LIFE SCIENCES↗

SU-F-303-10: Impact of Visual Biofeedback On Respiratory Reproducibility in 4DMRI

Purpose: Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4DCT. 4DMRI offers improved contrast. However, long scan times and irregular breathing patterns can be limiting. To address this, we introduced visual biofeedback (VBF) into 4DMRI. Methods: Eight healthy volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted coronal 4DMRIs were acquired on an open 1.0T MR- SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within pre-determined tolerances. 4DMRIs were acquired with and without VBF for 2–8 phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, end-inhale (EI) amplitude, and breathing variability (coefficient of variation, EI-COV). B-spline-based deformable image registration propagated contours from end-exhale (EE) to EI phases. Respiration-induced liver motion was calculated via centroid analysis and compared. Results: Incorporating VBF reduced 2-phase acquisition time (4.7±0.6 and 5.6±1.4 minutes with and without VBF, respectively) while reducing the amplitude EI-COV by 53.0±8.1%. On average, incorporating VBF reduced 8-phase 4DMRI acquisition times by 1.7±1.2 minutes and EI-COVs by 46.0±15.8%. Using VBF yielded higher duty cycles than free breathing (34.7% versus 28.3%, respectively). 4DMRI acquisition time was reduced for the cohort with VBF despite breathing rate remaining similar (10.5±4.0 with vs. 10.6±3.3 BPM without). Respiratory waveforms showed higher EI amplitude with VBF (0.84±0.05 a.u.) as compared to 0.72±0.06 a.u. without. This translated to differences in liver excursions, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.3±3.6, 4.8±2.1, and 1.6±1.0 mm, respectively, with VBF compared to 13.0±6.2, 3.8±2.4, and 1.2±1.4 mm without. Conclusion: Incorporating VBF system into 4DMRI substantially reduced acquisition time and breathing variability. While VBF reduced liver motion variability, differences in excursion were observed, suggesting that implementation will be required throughout the RT workflow. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an equipment evaluation agreement with MedSpira.

60 APPLIED LIFE SCIENCES↗

Neonatal respiratory support strategies—short and long-term respiratory outcomes

Mechanical ventilation (MV), although life-saving, is associated with chronic respiratory morbidity in both preterm and term born infants. New ventilation modes have been developed with the aim of minimising lung injury. These include invasive and non-invasive respiratory support strategies, techniques for less invasive surfactant administration (LISA) and closed-loop automated oxygen control (CLAC) systems. Increasingly, newborn infants with signs of respiratory distress are stabilised on continuous positive airway pressure (CPAP) and receive LISA. Early CPAP when compared to mechanical ventilation reduced the incidence of BPD and respiratory morbidity at 18 to 22 months corrected age. Nasal intermittent positive pressure ventilation reduced treatment failure rates compared to CPAP, but not bronchopulmonary dysplasia (BPD). LISA compared with intubation and surfactant delivery reduced BPD, but there is no evidence from randomised trials regarding long-term respiratory and neurodevelopmental outcomes. Synchronisation of positive pressure inflations with the infant's respiratory efforts used with volume targeting should be applied for infants requiring intubation as this strategy reduces BPD. A large RCT with long term follow up data demonstrated that prophylactic high frequency oscillatory ventilation (HFOV) improved respiratory and functional outcomes at school age, but those effects were not maintained after puberty. CLAC systems appear promising, but their effect on long term clinical outcomes has not yet been explored in randomised trials. Further studies are required to determine the role of newer ventilation modes such as neurally adjusted ventilator assist (NAVA). All such respiratory support strategies should be tested in randomised controlled trials powered to assess long-term outcomes.

Kaltsogianni, Ourania↗

Host cell recognition by the henipaviruses: Crystal structures of the Nipah G attachment glycoprotein and its complex with ephrin-B3

Nipah virus (NiV) and Hendra virus are the type species of the highly pathogenic paramyxovirus genus Henipavirus, which can cause severe respiratory disease and fatal encephalitis infections in humans, with case fatality rates approaching 75%. NiV contains two envelope glycoproteins, the receptor-binding G glycoprotein (NiV-G) that facilitates attachment to host cells and the fusion (F) glycoprotein that mediates membrane merger. The henipavirus G glycoproteins lack both hemagglutinating and neuraminidase activities and, instead, engage the highly conserved ephrin-B2 and ephrin-B3 cell surface proteins as their entry receptors. Here, we report the crystal structures of the NiV-G both in its receptor-unbound state and in complex with ephrin-B3, providing, to our knowledge, the first view of a paramyxovirus attachment complex in which a cellular protein is used as the virus receptor. Complex formation generates an extensive protein-protein interface around a protruding ephrin loop, which is inserted in the central cavity of the NiV-G {beta}-propeller. Analysis of the structural data reveals the molecular basis for the highly specific interactions of the henipavirus G glycoproteins with only two members (ephrin-B2 and ephrin-B3) of the very large ephrin family and suggests how they mediate in a unique fashion both cell attachment and the initiation of membrane fusion during the virus infection processes. The structures further suggest that the NiV-G/ephrin interactions can be effectively targeted to disrupt viral entry and provide the foundation for structure-based antiviral drug design.

59 BASIC BIOLOGICAL SCIENCES↗

Poster — Thur Eve — 37: Respiratory gating with an Elekta flattening filter free photon beam

In cases where surgery is not possible for lung cancer treatment, stereotactic body radiation therapy (SBRT) may be an option. One problem when treating this type of cancer is the motion of the lungs caused by the patient's respiration. It is possible to reduce the impact of this movement with the use of respiratory gating. By combining respiratory gating with a flattening filter free (FFF) photon beam linac, the increased treatment time caused by a reduced beam-on time of respiratory gating methods can be compensated by the inherent increased dose rate of FFF beams. This project's aim is to create hardware and software interfaces allowing free respiration gating on an Elekta Synergy-S linac specially modified to deliver 6 MV FFF photon beams. First, a printed circuit board was created for reading the signal from a Bellows Belt from Philips (a respiration monitor belt) and transmitting an On/Off signal to the accelerator. A software was also developed to visualize patient respiration. Secondly, a FFF model was created with the Pinnacle treatment planning system from Philips. Gamma (Γ) analysis (2%, 2 mm) was used to evaluate model. For fields going from 5.6 × 5.6 to 12 × 12 cm{sup 2}, central axis depth dose model fitting shows an average gamma value of 0.2 and 100% of gamma values remain under the Γ = 1 limit. For smaller fields (0.8 × 0.8 and 1.6 × 1.6 cm{sup 2}), Pinnacle has more trouble trying to fit the measurements, overestimating dose in penumbra and buildup regions.

60 APPLIED LIFE SCIENCES↗

In Vitro Dissolution Tests of Plutonium and Americium Containing Contamination Originating From ZPPR Fuel Plates

Assessing the extent of internal dose is of concern whenever workers are exposed to airborne radionuclides or other contaminants. Internal dose determinations depend upon a reasonable estimate of the expected biological half-life of the contaminants in the respiratory tract. One issue with refractory elements is determining the dissolution rate of the element. Actinides such as plutonium (Pu) and Americium (Am) tend to be very refractory and can have biological half-lives of tens of years. In the event of an exposure, the dissolution rates of the radionuclides of interest needs to be assessed in order to assign the proper internal dose estimates. During the November 2011 incident at the Idaho National Laboratory (INL) involving a ZPPR fuel plate, air filters in a constant air monitor (CAM) and a giraffe filter apparatus captured airborne particulate matter. These filters were used in dissolution rate experiments to determine the apparent dissolution half-life of Pu and Am in simulated biological fluids. This report describes these experiments and the results. The dissolution rates were found to follow a three term exponential decay equation. Differences were noted depending upon the nature of the biological fluid simulant. Overall, greater than 95% of the Pu and 93% of the Am were in a very slow dissolving component with dissolution half-lives of over 10 years.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Daily Supine LBNP Treadmill Exercise Maintains Upright Exercise Capacity During 14 Days of Bed Rest

Exposure to microgravity or bed rest reduces upright exercise capacity. Exercise modes, durations, and intensities which will effectively and efficiently counteract such deconditioning are presently unresolved. We that daily supine treadmill interval training with lower body negative pressure (LBNP) would prevent reduction in upright exercise capacity during 14 days of 6 deg. head-down bed rest (BR). Eight healthy male subjects underwent two 14 day BR protocols separated by 3 months. In a crossover design, subjects either remained at strict BR or performed 40 min of daily exercise consisting of supine walking and running at intensities varying from 40-80% of pre-BR upright peak oxygen uptake (VO2). LBNP during supine exercise was used to provide 1.0 to 1.2 times body weight of footward force. An incremental upright treadmill test to measure submaximal and peak exercise responses was given pre- and post-BR. In the non-exercise condition, peak VO2 and time to exhaustion were reduced 16 +/- 4% and 10 +/- 1% (p less than 0.05), respectively, from pre-BR. With LBNP exercise these variables were not significantly different (NS) from pre-BR. During submaximal treadmill speeds after BR, heart rate was higher (11 +/- 11 bpm, p less than 0.05) and respiratory exchange ratio was elevated (p less than 0.05) in the no exercise condition. Both were maintained at pre-BR levels in the LBNP exercise condition (NS from pre-BR). Since this supine treadmill interval training with addition of LBNP maintained upright exercise responses and capacity during BR, this countermeasure may also be effective during space flight.

Ertl, Andy C.↗

Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements

Purpose: Four-dimensional computed tomography (4DCT) can be used to make measurements of pulmonary function longitudinally. The sensitivity of such measurements to identify change depends on measurement uncertainty. Previously, intrasubject reproducibility of Jacobian-based measures of lung tissue expansion was studied in two repeat prior-RT 4DCT human acquisitions. Difference in respiratory effort such as breathing amplitude and frequency may affect longitudinal function assessment. In this study, the authors present normalization schemes that correct ventilation images for variations in respiratory effort and assess the reproducibility improvement after effort correction.Methods: Repeat 4DCT image data acquired within a short time interval from 24 patients prior to radiation therapy (RT) were used for this analysis. Using a tissue volume preserving deformable image registration algorithm, Jacobian ventilation maps in two scanning sessions were computed and compared on the same coordinate for reproducibility analysis. In addition to computing the ventilation maps from end expiration to end inspiration, the authors investigated the effort normalization strategies using other intermediated inspiration phases upon the principles of equivalent tidal volume (ETV) and equivalent lung volume (ELV). Scatter plots and mean square error of the repeat ventilation maps and the Jacobian ratio map were generated for four conditions: no effort correction, global normalization, ETV, and ELV. In addition, gamma pass rate was calculated from a modified gamma index evaluation between two ventilation maps, using acceptance criterions of 2 mm distance-to-agreement and 5% ventilation difference.Results: The pattern of regional pulmonary ventilation changes as lung volume changes. All effort correction strategies improved reproducibility when changes in respiratory effort were greater than 150 cc (p < 0.005 with regard to the gamma pass rate). Improvement of reproducibility was correlated with respiratory effort difference (R = 0.744 for ELV in the cohort with tidal volume difference greater than 100 cc). In general for all subjects, global normalization, ETV and ELV significantly improved reproducibility compared to no effort correction (p = 0.009, 0.002, 0.005 respectively). When tidal volume difference was small (less than 100 cc), none of the three effort correction strategies improved reproducibility significantly (p = 0.52, 0.46, 0.46 respectively). For the cohort (N = 13) with tidal volume difference greater than 100 cc, the average gamma pass rate improves from 57.3% before correction to 66.3% after global normalization, and 76.3% after ELV. ELV was found to be significantly better than global normalization (p = 0.04 for all subjects, and p = 0.003 for the cohort with tidal volume difference greater than 100 cc).Conclusions: All effort correction strategies improve the reproducibility of the authors' pulmonary ventilation measures, and the improvement of reproducibility is highly correlated with the changes in respiratory effort. ELV gives better results as effort difference increase, followed by ETV, then global. However, based on the spatial and temporal heterogeneity in the lung expansion rate, a single scaling factor (e.g., global normalization) appears to be less accurate to correct the ventilation map when changes in respiratory effort are large.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of sliding baseline methods for spatial estimation for cluster detection in the biosurveillance system

Background: The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods: The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results: Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion: The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Fluxomic Analysis Reveals Central Carbon Metabolism Adaptation for Diazotroph Azotobacter vinelandii Ammonium Excretion

Diazotrophic bacteria are an attractive biological alternative to synthetic nitrogen fertilizers due to their remarkable capacity to fix atmospheric nitrogen gas to ammonium via nitrogenase enzymes. However, how diazotrophic bacteria tailor central carbon catabolism to accommodate the energy requirement for nitrogenase activity is largely unknown. In this study, we used Azotobacter vinelandii DJ and an ammonium excreting mutant, AV3 (ΔNifL), to investigate central carbon metabolism fluxes and central cell bioenergetics in response to ammonium availability and nitrogenase activity. Enabled by the powerful and reliable methodology of 13 C-metabolic flux analysis, we show that the respiratory TCA cycle is upregulated in association with increased nitrogenase activity and causes a monotonic decrease in specific growth rate. Whereas the activity of the glycolytic Entner-Doudoroff pathway is positively correlated with the cell growth rate. These new observations are formulated into a 13 C-metabolic flux model which further improves the understanding and interpretation of intracellular bioenergetics. This analysis leads to the conclusion that, under aerobic conditions, respiratory TCA metabolism is responsible for the supply of additional ATP and reducing equivalents required for elevated nitrogenase activity. This study provides a quantitative relationship between central carbon and nitrogen metabolism in an aerobic diazotroph for the first time.

09 BIOMASS FUELS↗

Experimental evaluation of respiratory droplet spread to rooms connected by a central ventilation system

This article presents results from an experimental study to ascertain the transmissibility of the SARS-CoV-2 virus between rooms in a building that are connected by a central ventilation system. Respiratory droplet surrogates made of mucus and virus mimics were released in one room in a test building and measurements of concentration levels were made in other rooms connected via the ventilation system. The paper presents experimental results for different ventilation system configurations, including ventilation rate, filtration level (up to MERV-13), and fractional outdoor air intake. The most important finding is that respiratory droplets can and do transit through central ventilation systems, suggesting a mechanism for viral transmission (and COVID-19 specifically) within the built environment in reasonable agreement with well-mixed models. We also find the deposition of these droplets on room walls to be negligibly small. Furthermore, the energy use impact of the different configuration settings is also quantified to help inform intelligent building operation that can simultaneously address energy use and occupant health.

60 APPLIED LIFE SCIENCES↗

Effects of 31 FDA approved small-molecule kinase inhibitors on isolated rat liver mitochondria

The FDA has approved 31 small-molecule kinase inhibitors (KIs) for human use as of November 2016, with six having black box warnings for hepatotoxicity (BBW-H) in product labeling. The precise mechanisms and risk factors for KI-induced hepatotoxicity are poorly understood. Here, the 31 KIs were tested in isolated rat liver mitochondria, an in vitro system recently proposed to be a useful tool to predict drug-induced hepatotoxicity in humans. The KIs were incubated with mitochondria or submitochondrial particles at concentrations ranging from therapeutic maximal blood concentrations (Cmax) levels to 100-fold Cmax levels. Ten endpoints were measured, including oxygen consumption rate, inner membrane potential, cytochrome c release, swelling, reactive oxygen species, and individual respiratory chain complex (I–V) activities. Of the 31 KIs examined only three including sorafenib, regorafenib and pazopanib, all of which are hepatotoxic, caused significant mitochondrial toxicity at concentrations equal to the Cmax, indicating that mitochondrial toxicity likely contributes to the pathogenesis of hepatotoxicity associated with these KIs. At concentrations equal to 100-fold Cmax, 18 KIs were found to be toxic to mitochondria, and among six KIs with BBW-H, mitochondrial injury was induced by regorafenib, lapatinib, idelalisib, and pazopanib, but not ponatinib, or sunitinib. Mitochondrial liability at 100-fold Cmax had a positive predictive power (PPV) of 72% and negative predictive power (NPV) of 33% in predicting human KI hepatotoxicity as defined by product labeling, with the sensitivity and specificity being 62% and 44%, respectively. Similar predictive power was obtained using the criterion of Cmax ≥1.1 µM or daily dose ≥100 mg. Mitochondrial liability at 1–2.5-fold Cmax showed a 100% PPV and specificity, though the NPV and sensitivity were 32% and 14%, respectively. These data provide novel mechanistic insights into KI hepatotoxicity and indicate that mitochondrial toxicity at therapeutic levels can help identify hepatotoxic KIs.

60 APPLIED LIFE SCIENCES↗

Reactive oxygen species produced by NADPH oxidase and mitochondrial dysfunction in lung after an acute exposure to Residual Oil Fly Ashes

Reactive O{sub 2} species production triggered by particulate matter (PM) exposure is able to initiate oxidative damage mechanisms, which are postulated as responsible for increased morbidity along with the aggravation of respiratory diseases. The aim of this work was to quantitatively analyse the major sources of reactive O{sub 2} species involved in lung O{sub 2} metabolism after an acute exposure to Residual Oil Fly Ashes (ROFAs). Mice were intranasally instilled with a ROFA suspension (1.0 mg/kg body weight), and lung samples were analysed 1 h after instillation. Tissue O{sub 2} consumption and NADPH oxidase (Nox) activity were evaluated in tissue homogenates. Mitochondrial respiration, respiratory chain complexes activity, H{sub 2}O{sub 2} and ATP production rates, mitochondrial membrane potential and oxidative damage markers were assessed in isolated mitochondria. ROFA exposure was found to be associated with 61% increased tissue O{sub 2} consumption, a 30% increase in Nox activity, a 33% increased state 3 mitochondrial O{sub 2} consumption and a mitochondrial complex II activity increased by 25%. During mitochondrial active respiration, mitochondrial depolarization and a 53% decreased ATP production rate were observed. Neither changes in H{sub 2}O{sub 2} production rate, nor oxidative damage in isolated mitochondria were observed after the instillation. After an acute ROFA exposure, increased tissue O{sub 2} consumption may account for an augmented Nox activity, causing an increased O{sub 2}{sup ·−} production. The mitochondrial function modifications found may prevent oxidative damage within the organelle. These findings provide new insights to the understanding of the mechanisms involving reactive O{sub 2} species production in the lung triggered by ROFA exposure. - Highlights: • Exposure to ROFA alters the oxidative metabolism in mice lung. • The augmented Nox activity contributes to the high tissue O{sub 2} consumption. • Exposure to ROFA produces alterations in mitochondrial function. • ΔΨ{sub m} decrease in state 3 may be responsible for the decreased ATP production. • Mild uncoupling prevents mitochondrial oxidative damage.

60 APPLIED LIFE SCIENCES↗

Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems

Purpose: To develop and implement a failure mode and effect analysis (FMEA)-based commissioning and quality assurance framework for dynamic multileaf collimator (DMLC) tumor tracking systems. Methods: A systematic failure mode and effect analysis was performed for a prototype real-time tumor tracking system that uses implanted electromagnetic transponders for tumor position monitoring and a DMLC for real-time beam adaptation. A detailed process tree of DMLC tracking delivery was created and potential tracking-specific failure modes were identified. For each failure mode, a risk probability number (RPN) was calculated from the product of the probability of occurrence, the severity of effect, and the detectibility of the failure. Based on the insights obtained from the FMEA, commissioning and QA procedures were developed to check (i) the accuracy of coordinate system transformation, (ii) system latency, (iii) spatial and dosimetric delivery accuracy, (iv) delivery efficiency, and (v) accuracy and consistency of system response to error conditions. The frequency of testing for each failure mode was determined from the RPN value. Results: Failures modes with RPN{>=}125 were recommended to be tested monthly. Failure modes with RPN<125 were assigned to be tested during comprehensive evaluations, e.g., during commissioning, annual quality assurance, and after major software/hardware upgrades. System latency was determined to be {approx}193 ms. The system showed consistent and accurate response to erroneous conditions. Tracking accuracy was within 3%-3 mm gamma (100% pass rate) for sinusoidal as well as a wide variety of patient-derived respiratory motions. The total time taken for monthly QA was {approx}35 min, while that taken for comprehensive testing was {approx}3.5 h. Conclusions: FMEA proved to be a powerful and flexible tool to develop and implement a quality management (QM) framework for DMLC tracking. The authors conclude that the use of FMEA-based QM ensures efficient allocation of clinical resources because the most critical failure modes receive the most attention. It is expected that the set of guidelines proposed here will serve as a living document that is updated with the accumulation of progressively more intrainstitutional and interinstitutional experience with DMLC tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗