Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RELEASE DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Final Rulison Path Forward

The U.S. Department of Energy (DOE) Office of Legacy Management developed this report as a guide for discussions with the Colorado State regulators and other interested stakeholders in response to increased drilling for natural gas reserves near the underground nuclear explosion site at Rulison, Colorado. The Rulison site is located in the Piceance Basin of western Colorado, 40 miles northeast of Grand Junction. The Rulison test was the second natural gas reservoir stimulation experiment in the Plowshare Program, which was designed to develop peaceful uses for nuclear energy. On September 10, 1969, the U.S. Atomic Energy Commission, a predecessor agency of DOE, detonated a 40-kiloton nuclear device 8426 feet below the ground surface in an attempt to release commercially marketable quantities of natural gas. The blast vaporized surrounding rock and formed a cavity about 150 feet in diameter. Although the contaminated materials from drilling operations were subsequently removed from the surface of the blast site, no feasible technology exists to remove subsurface radioactive contamination in or around the test cavity. An increase in drilling for natural gas near the site has raised concern about the possibility of encountering residual radioactivity from the area of the detonation. DOE prohibits drilling in the 40-acre lot surrounding the blast site at a depth below 6000 feet. DOE has no evidence that indicates contamination from the Rulison site detonation has migrated or will ever migrate beyond the 40-acre institutional control boundary. The Colorado Oil and Gas Conservation Commission (COGCC) established two wider boundaries around the site. When a company applies for a permit to drill within a 3-mile radius of surface ground zero, COGCC notifies DOE and provides an opportunity to comment on the application. COGCC also established a half-mile radius around surface ground zero. An application to drill within one-half mile requires a full hearing before the commission. This report outlines DOE's recommendation that gas developers adopt a conservative, staged drilling approach allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. This staged approach calls for collecting data from wells outside the half-mile zone before drilling closer, and then drilling within the half-mile zone in a sequential manner, first at low contamination probability locations and then moving inward. DOE's recommended approach for drilling in this area will protect public safety while allowing collection of additional data to confirm that contamination is contained within the 40-acre institutional control boundary.

54 ENVIRONMENTAL SCIENCES↗

Recent Developments in the WEC-Sim Open-Source Design Tool: Preprint

WEC-Sim (Wave Energy Converter SIMulator) is an open-source code for simulating wave energy converters, which has been actively developed and applied to simulate a wide variety of device archetypes and has become a popular tool since its initial release in 2014. WEC-Sim is developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) within the MATLAB/SIMULINK environment. Figure 1 illustrates a general wave-to-wire model which begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of a single WEC (or array), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modelling the entire wave-to-wire is difficult and encompass multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM) based-frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). Within this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Table 1 lists additional WEC-Sim functionalities, which are created using prebuilt Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems.

hydrodynamics modeling↗

Environmental Risk Evaluation System – An Approach to Ranking Risk of Ocean Energy Development on Coastal and Estuarine Environments

Deployment and operation of ocean energy devices does not represent the first foray into industrialization of the oceans; shipping, nearshore development, waste disposal, subsea mining, oil and gas extraction, and large-scale commercial fishing all coexist in various states of equilibrium with the marine environment. In most cases these industries were developed without a clear understanding of the likely outcomes of large-scale development. In virtually every country where the harvest of ocean energy is emerging, regulators and stakeholders require that the industry examine potential effects of devices, minimize the footprint of effects, and provide management measures that either avoid the impacts or mitigate to further reduce the residual impacts. The ERES analysis is based on scenarios that are consistent with sequences of events that lead to adverse impacts, distinguishing between episodic, intermittent, and chronic risks. In the context of ocean energy development, an episodic scenario might involve the exceedingly rare but potentially devastating event of an oil spill from vessels caused by the presence of the device, while vulnerable receptors are present; understanding the risk of such a scenario involves determining the probability of the occurrence by examining factors such as the petroleum content of ocean energy devices, the vessel traffic volume and the proximity of shipping lanes to the ocean energy devices, the reliability of the control measures to avoid an episodic event, and the likely presence of seabirds, marine mammals, or fish that may be affected by oil. In contrast, chronic risk scenarios involve events or circumstances that are continuous, so that risk characterization involves assessing only the severity of the consequences. An example of a chronic risk scenario might be the toxicity to marine organisms due to low-level chemical releases from anti-biofouling paints and coatings that may be used on devices, and the effect that the level of toxicity may have on marine flora and fauna. Between these two extremes are intermittent events, such as encounters between fish and rotating tidal turbine blades that will occur only when fish are present and the tidal device is turning. A key feature of understanding risk is describing the uncertainty associated with the occurrence of an episodic, intermittent, or chronic event, as well as the uncertainty of the resulting consequences.

ocean energy↗

Critical overview of Nitinol surfaces and their modifications for medical applications

Nitinol, a group of nearly equiatomic shape memory and superelastic NiTi alloys, is being extensively explored for medical applications. Release of Ni in the human body, a potential problem with Nitinol implant devices, has stimulated a great deal of research on its surface modifications and coatings. In order to use any of the developed surfaces in implant designs, it is important to understand whether they really have advantages over bare Nitinol. This paper overviews the current situation, discusses the advantages and disadvantages of new surfaces as well as the limitations of the studies performed. It presents a comprehensive analysis of surface topography, chemistry, corrosion behavior, nickel release and biological responses to Nitinol surfaces modified mechanically or using such methods as etching in acids and alkaline solutions, electropolishing, heat and ion beam treatments, boiling in water and autoclaving, conventional and ion plasma implantations, laser melting and bioactive coating deposition. The analysis demonstrates that the presently developed surfaces vary in thickness from a few nanometers to micrometers, and that they can effectively prevent Ni release if the surface integrity is maintained under strain and if no Ni-enriched sub-layers are present. Whether it is appropriate to use various low temperature pre-treatment protocols ({le} 160 C) developed originally for pure titanium for Nitinol surface modifications and coatings is also discussed. The importance of selection of original Nitinol surfaces with regard to the performance of coatings and comparative performance of controls in the studies is emphasized. Considering the obvious advantages of bare Nitinol surfaces for superelastic implants, details of their preparation are also outlined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital Maskless Photolithographic Patterning of DNA-Functionalized Poly(ethylene glycol) Diacrylate Hydrogels with Visible Light Enabling Photodirected Release of Oligonucleotides

Soft biomaterials possessing structural hierarchy have growing applications in lab-on-chip devices, artificial tissues, and micromechanical and chemomechanical systems. The ability to integrate sets of biomolecules, specifically DNA, within hydrogel substrates at precise locations could offer the potential to form and modulate complex biochemical processes with DNA-based molecular switches in such materials and provide a means of creating dynamic spatial patterns, thus enabling spatiotemporal control of a wide array of reaction-diffusion phenomena prevalent in biological systems. In this paper, we develop a means of photopatterning two-dimensional DNA-functionalized poly(ethylene glycol) diacrylate (PEGDA) hydrogel architectures with an aim toward these applications. While PEGDA photopatterning methods are well-established for the fabrication of hydrogels, including those containing oligonucleotides, the photoinitiators typically used have significant crosstalk with many UV-photoswitchable chemistries including nitrobenzyl derivatives. We demonstrate the digital photopatterning of PEGDA-co-DNA hydrogels using a blue light-absorbing (470 nm peak) photoinitiator system and macromer comprised of camphorquinone, triethanolamine, and poly(ethylene glycol) diacrylate ($M$ n = 575) that minimizes absorption in the UV-A wavelength range commonly used to trigger photoswitchable chemistries. We demonstrate this method using digital maskless photolithography within microfluidic devices that allows for the reliable construction of multidomain structures. The method achieves feature resolutions as small as 25 μm, and the resulting materials allow for lateral isotropic bulk diffusion of short single-stranded (ss) DNA oligonucleotides. Finally, we show how the use of these photoinitiators allows for orthogonal control of photopolymerization and UV-photoscission of acrylate-modified DNA containing a 1-(2-nitrophenyl) ethyl spacer to selectively cleave DNA from regions of a PEGDA substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alarm inhalation dosemeter for long living radioactive dust due to an uncontrolled release

MyRIAM is the acronym for My Radioactivity In Air Monitor and points out that the device was designed for personal use to detect any radioactivity in the air at the place and at the moment of danger. The active air sampling process enables a detection limit several orders of magnitude below that of Gamma detectors. Therefore, it is the unique way to detect dangerous exposures in time.Individual protection against inhalation of long living radioactive dust (LLRD) saves human life and health. LLRD may occur in natural environment as well as in case of nuclear accidence or military and terrorist attacks. But in any case, the immediate warning of the population is of great importance. Keep in mind: it is very easy to avoid LLRD inhalation--but you have to recognize the imminent danger. The second requirement of gap-less documentation and reliable assessment of any derived LLRD exposure is building the link to Dosimetry applications.The paper demonstrates the possibility to design small and low cost air samplers, which can be used as personal alarm dosimeters and fulfil the requirements mentioned above.Several test measurements taken by a mobile phone sized MyRIAM, shall be used to demonstrate the correctness of this statement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sorption-based atmospheric water harvesting device

A water-harvesting system can operate with a material that can take up and release water with minimum energy requirements and powered by low-grade energy sources, such as sunlight, in order to potentially allow its deployment into households, especially those located in sunny regions. A water-harvesting method and system can include vapor adsorption using a porous metal-organic framework. In certain embodiments, the porous metal-organic framework can include metal-organic framework in ambient air with low relative humidity, typical of the levels found in most dry regions of the world.

42 ENGINEERING↗

Sorption-based atmospheric water harvesting device

A water-harvesting system can operate with a material that can take up and release water with minimum energy requirements and powered by low-grade energy sources, such as sunlight, in order to potentially allow its deployment into households, especially those located in sunny regions. A water-harvesting method and system can include vapor adsorption using a porous metal-organic framework. In certain embodiments, the porous metal-organic framework can include metal-organic framework in ambient air with low relative humidity, typical of the levels found in most dry regions of the world.

42 ENGINEERING↗

Effect of rapid thermal annealing of copper indium aluminium gallium diselenide solar cell devices and its deposition challenges

Thin-film photovoltaic research based on ternary or quaternary absorber materials has mainly concentrated on copper (indium/gallium) diselenide, CuIn x Ga 1-x Se 2 (CIGS). This material has demonstrated exceptional energy conversion efficiencies. By altering the In/Ga ratio the band gap can be varied from 1.02 eV (for CuInSe 2 ) to 1.68 eV (for CuGaSe 2 ). However, research from leading groups showed that cells have maximum efficiency at or below 1.35 eV. This paper reports the challenges of using aluminium alloyed CIGS deposited with a single step co-evaporation method. Adding aluminium is found to reduce the bulk trap state density for wide gap devices. However, it created significant safety issues when compared to conventional CIGS co-evaporation deposition systems. The release of H 2 Se when moisture comes in contact with aluminium selenide was resolved by placing exhaust lines at various places of the deposition chamber. A single phase CIAGS device with a bandgap of 1.30 eV was prepared using a co-evaporation method. The fabricated solar cell devices with CIAGS absorber layers and resulted in a photoconversion efficiency of 10.3%. A progressive rapid thermal annealing at various temperature resulted in a 10% increase in the overall efficiency at 300 °C. The efficiencies were reduced when the RTA temperature increased above 300 °C.

14 SOLAR ENERGY↗

Influence of electron-beam lithography exposure current level on the transport characteristics of graphene field effect transistors

Many factors have been identified to influence the electrical transport characteristics of graphene field-effect transistors. In this report, we examine the influence of the exposure current level used during electron beam lithography (EBL) for active region patterning. In the presence of a self-assembled hydrophobic residual layer generated by oxygen plasma etching covering the top surface of the graphene channel, we show that the use of low EBL current level results in higher mobility, lower residual carrier density, and charge neutrality point closer to 0 V, with reduced device-to-device variations. We show that this correlation originates from the resist heating dependent release of radicals from the resist material, near its interface with graphene, and its subsequent trapping by the hydrophobic polymer layer. Using a general model for resist heating, we calculate the difference in resist heating for different EBL current levels. We further corroborate our argument through control experiments, where radicals are either intentionally added or removed by other processes. We also utilize this finding to obtain mobilities in excess of 18 000 cm{sup 2}/V s on silicon dioxide substrates. We believe these results are applicable to other 2D materials such as transition metal dichalcogenides and nanoscale devices in general.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of electrostatic precipitator (ESP) technology to remove elemental mercury vapor, HG(0)

The presence of mercury vapor or other forms of mercury presents issues with worker safety, decommissioning facilities, and environmental impacts. As such, it is desired to develop a strategy to either remove or reduce mercury levels in Oak Ridge’s Y-12 Complex facilities. A testing methodology was developed to evaluate electrostatic precipitator technology for removal of mercury vapor. This methodology involved supplying mercury vapor-containing air to the ESP device by flowing air through a column containing alternating layers of sand and liquid mercury droplets. Initial attempts at quantifying the efficacy of the ESP device in removing mercury vapor were plagued with difficulties in controlling the flow of mercury into the ESP device due to poor performance of the generator column and the contamination of these experiments with mercury from an unknown source. These issues were resolved by creating a new generator column with slower air velocity and higher surface area of liquid mercury, along with moving the air intake for the ESP device to outside of the chemical hood in which testing took place. This resulted in a steady, quantified flow of mercury vapor from the generator column and no observation of unintended mercury sources. A final test of the ESP device under these controlled conditions showed that for a certain amount of time (on the order of 20-30 minutes) mercury concentrations were reduced by approximately 33 - 67% of the inlet concentration. However, episodic releases or pulses of mercury observed only at the outlet indicated that the mercury accumulated in the ESP device is periodically expelled. As a result, it was not deemed to be an efficient strategy for the removal of elemental mercury vapor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Micro-architecture embedding ultra-thin interlayer to bond diamond and silicon via direct fusion

The continuous demand on miniaturized electronic circuits bearing high power density illuminates the need to modify the silicon-on-insulator-based chip architecture. This is due to the low thermal conductivity of the few hundred nanometer-thick insulator present between the silicon substrate and active layers. The thick insulator is notorious for releasing the heat generated from the active layers during the operation of devices, leading to degradation in their performance and thus reducing their lifetime. To avoid the heat accumulation, we propose a method to fabricate the silicon-on-diamond (SOD) microstructure featured by an exceptionally thin silicon oxycarbide interlayer (~3 nm). While exploiting the diamond as an insulator, we employ spark plasma sintering to render the silicon directly fused to the diamond. Importantly, this process can manufacture the SOD microarchitecture via a simple/rapid way and incorporates the ultra-thin interlayer for minute thermal resistance. The approach invented herein expects to minimize the thermal interfacial resistance of the devices and is thus deemed as a breakthrough appealing to the current chip industry.

36 MATERIALS SCIENCE↗

Nanosensors as Reservoir Engineering Tools to Map Insitu Temperature Distributions in Geothermal Reservoirs

The feasibility of using nanosensors to measure temperature distribution and predict thermal breakthrough in geothermal reservoirs is addressed in this report. Four candidate sensors were identified: melting tin-bismuth alloy nanoparticles, silica nanoparticles with covalently-attached dye, hollow silica nanoparticles with encapsulated dye and impermeable melting shells, and dye-polymer composite time-temperature indicators. Four main challenges associated with the successful implementation of temperature nanosensors were identified: nanoparticle mobility in porous and fractured media, the collection and detection of nanoparticles at the production well, engineering temperature sensing mechanisms that are both detectable and irreversible, and inferring the spatial geolocation of temperature measurements in order to map temperature distribution. Initial experiments were carried out to investigate each of these challenges. It was demonstrated in a slim-tube injection experiment that it is possible to transport silica nanoparticles over large distances through porous media. The feasibility of magnetic collection of nanoparticles from produced fluid was evaluated experimentally, and it was estimated that 3% of the injected nanoparticles were recovered in a prototype magnetic collection device. An analysis technique was tailored to nanosensors with a dye-release mechanism to estimate temperature measurement geolocation by analyzing the return curve of the released dye. This technique was used in a hypothetical example problem, and good estimates of geolocation were achieved. Tin-bismuth alloy nanoparticles were synthesized using a sonochemical method, and a bench heating experiment was performed using these nanoparticles. Particle growth due to melting was observed, indicating that tin-bismuth nanoparticles have potential as temperature nanosensors

15 GEOTHERMAL ENERGY↗

Identification of Hydrogen Rail Maintenance Facility Hazards

Maintenance facilities for hydrogen rail, the activities conducted within such facilities, and how these activities differ from ordinary rail or hydrogen vehicle maintenance are currently being considered for the hazards specific to hydrogen. By performing a hazard and operability study (HAZOP) on numerous potential maintenance and repair scenarios, select low, medium, and high risk hazards relevant to hydrogen rail systems in such environments have been identified. The analysis resulted in 79 unique HAZOP scenarios: one scenario in the high risk category, 43 in the medium risk category, and 35 in the low risk category. Notably, large accidental releases of hydrogen due to tank rupture, aberrant defueling processes, or relief device opening within a facility are important low likelihood consequences that should nevertheless be appropriately prevented and mitigated.

08 HYDROGEN↗

Integrating decontamination strategies into a waste estimation support tool for radiological incidents - 15284

In the planning and preparedness stages for a response to a radiological incident, it is important to include waste management considerations when developing the decontamination/demolition/cleanup approach because waste management can be a driver for time and cost. An individualized type of strategy based on the occupancy of affected buildings may be an effective approach. The U.S. Environmental Protection Agency's (EPA's) Waste Estimation Support Tool (WEST) is a novel application of the Federal Emergency Management Agency (FEMA) Hazus-MH software. WEST enables users to estimate the characteristics, amount, and residual radioactivity of waste generated from remediation and cleanup activities after a radiological incident, including incidents caused by radiological dispersal devices and improvised nuclear devices, as well as nuclear power plant accidents. This paper will describe the recently released update to WEST, which includes the ability to export the waste estimate results back into ArcGIS for further visualization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methane Emissions Produced by Pneumatic Devices and Produced Water Tanks on Natural Gas Wellsites

In recent years, more scrutiny has been placed on the release of greenhouse gasses (GHGs) by the oil and gas industry in North America as climate concerns increase. In the coming years, stricter regulations proposed by the Environmental Protection Agency (EPA) concerning the release of GHGs will further direct attention to GHG emissions quantification, modeling, and overall reduction. Active natural gas wellsites employ production equipment that routinely emits methane during normal operation. Production equipment often includes, but is not limited to, gas production units (GPUs), pneumatic controllers (PCs) and actuators powered by produced natural gas, and produced water storage tanks. This work details direct methane emission measurements taken at active natural gas wellsites originating from intermittent pneumatic controllers and produced water storage tanks. Efforts to model methane flows originating from these sources are also detailed, and those results are compared to direct measurement. The direct methane emissions measurement campaign collected flow data from two active dry wellsites in the Marcellus shale region. These measurement campaigns captured, in total, several weeks of continuous data from these sites. Data included multiple pneumatic device vent flowrate channels, a single channel monitoring total emissions vented from the produced water storage tanks, and corresponding site weather data. Periodic composition measurements were taken from flows vented from produced water tanks. Computational modeling efforts attempted to mimic a given site’s methane emissions behavior given limited input parameters. Direct measurement data and simulation data yielded, through reduction and analysis, apparent methane emissions factors, statistics on pneumatic device actuation events, important relationships between GPU parameters and pneumatic device actuation events, produced water storage tank vent flows and flow compositions, and parameters most contributing to the magnitude and frequency of these fugitive methane emissions. Measurements, considering data from a 72hr period, produced PC emissions factors from 0.008 to 0.03 SCFH per device with an average device emitting 0.026 SCFH at the first site. The second site produced PC emissions factors spanning from 0.05 to 25.47 SCFH with an average device emitting 1.93 SCFH not including the 25.47 SCFH device, which was assumed to be malfunctioning. Two unique water tank emission measurements were made, 618 g CH4 per hour and 32.6 g CH4 per hour. On a water basis, the water tank emissions factors were 0.66 and 0.042 kg CH4 per bbl of water, respectively.

03 NATURAL GAS↗

Device for collecting chemical compounds and related methods

A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from the fixed surfaces so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

47 OTHER INSTRUMENTATION↗

Devices for collecting chemical compounds

A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from a fixed surface so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

47 OTHER INSTRUMENTATION↗