Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

We present that a large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d/d. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. Finally, the d/d resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high precision calibration of the nonlinear energy response at Daya Bay

A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment’s antineutrino detectors is observed. The energy nonlinearity originates from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by γ calibration points from deployed and naturally occurring radioactive sources, the β spectrum from 12 B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. With this beind said, less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The STAR Forward Silicon Tracker

The Forward Silicon Tracker (FST) is a pivotal component of the forward upgrade of the Solenoidal Tracker at RHIC (STAR), designed to discern hadron charge signs with a momentum resolution better than 30% for 0.2 < p T < 2GeV/c in the 2.5 < η < 4 pseudorapidity range. Its compact design features three disks along the beam direction, minimized material budget, and scattering effects. The FST uses Hamamatsu’s p-in-n silicon strip sensors with a double metal layer that enables efficient signal routing to the readout electronics, enhancing overall detector performance. The flexible hybrid boards, essential for the readout system, are constructed with Kapton and copper layers to optimize signal handling and power distribution. These boards connect silicon strips to analogue pipeline ASIC APV25-S1 chips, which read up to 128 channels each. A cooling system with nonconducting, volatile NOVEC 7200 coolant at 22.2 °C mitigates ASIC-generated heat. Furthermore, the FST enhances forward tracking performance at STAR as an integral part of the forward upgrade.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Liquid Argon Time Projection Chamber Trigger Development with MicroBooNE

The Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) neutrino detector at Fermilab that has been operating since 2015. It aims to perform v-Ar cross-section measurements, explore the low-energy excess reported by the MiniBooNE experiment and perform a combined search for sterile neutrino oscillations as part of three LArTPCs that make up the Short Baseline Neutrino (SBN) Program at Fermilab. Since MicroBooNE is currently in an R&D phase, it offers a unique opportunity for the implementation and testing of TPC-based triggers as R&D towards the Deep Underground Neutrino Experiment (DUNE). One of the technical challenges of DUNE that we aim to address with this study is that of efficient self-triggering of a LArTPC utilizing TPC signal information. This capability will enable searches for rare processes in DUNE, such as neutrino interactions from a potential galactic supernova burst. This talk will describe the MicroBooNE TPC readout system and ongoing R&D efforts to develop and demonstrate TPC-based triggering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-Based Triggering and Reconstruction of Michel Electrons in LArIAT

The LArIAT Experiment aims to calibrate the liquid argon time projection chamber (LArTPC) using a beam of charged particles at the Fermilab Test Beam Facility. It is equipped with a novel scintillation light readout system using PMTs and custom SiPM preamplifier boards to detect light from reflector foils coated with wavelength-shifting TPB. A trigger on delayed secondary flashes of light captures events containing stopping cosmic muons together with the Michel electrons coming from their subsequent decay. This dedicated Michel trigger supplies an abundant sample of low-energy electrons throughout the detector's active volume, providing opportunities to study the combined calorimetric capabilities of the light system and the TPC. Preliminary results using scintillation light to study properties of the Michel electron sample are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing LAr Scintillation Light Collection Ideas in the Short Baseline Neutrino Detector

Scintillation light is becoming the most rapidly developing feature of Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors due to its capability to enhance and expand their physics reach traditionally based on charge readout. The SBND detector, set to be built on the Booster Neutrino Beam Line at Fermilab, is in a unique position to test novel liquid argon scintillation light readout systems in a detector with physics neutrino events. The different ideas under consideration by the collaboration are described, including an array of PMTs detecting direct light, SiPM coupled lightguide bars and a setup which uses PMTs/SiPMS and wavelength shifter covered reflector foils, as well as their respective strengths and physics foci and the benchmarks used to compare them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the engineering run of the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)

The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW(th) nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed around the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The in-situ calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor ON and OFF are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below 2 e – RMS and stable background rates. In conclusion, the success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid argon TPC signal formation, signal processing and reconstruction techniques

This document describes a reconstruction chain that was developed for the ArgoNeuT and MicroBooNE experiments at Fermilab. These experiments study accelerator neutrino interactions that occur in a Liquid Argon Time Projection Chamber. Reconstructing the properties of particles produced in these interactions benefits from the knowledge of the micro-physics processes that affect the creation and transport of ionization electrons to the readout system. A wire signal deconvolution technique was developed to convert wire signals to a standard form for hit reconstruction, to remove artifacts in the electronics chain and to remove coherent noise. A unique clustering algorithm reconstructs line-like trajectories and vertices in two dimensions which are then matched to create of 3D objects. In conclusion, these techniques and algorithms are available to all experiments that use the LArSoft suite of software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-element germanium detectors for synchrotron applications

In this paper, we have developed a series of monolithic multi-element germanium detectors, based on sensor arrays produced by the Forschungzentrum Julich, and on Application-specific integrated circuits (ASICs) developed at Brookhaven. Devices have been made with element counts ranging from 64 to 384. These detectors are being used at NSLS-II and APS for a range of diffraction experiments, both monochromatic and energy-dispersive. Compact and powerful readout systems have been developed, based on the new generation of FPGA system-on-chip devices, which provide closely coupled multi-core processors embedded in large gate arrays. Finally, we will discuss the technical details of the systems, and present some of the results from them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analog pile-up circuit technique using a single capacitor for the readout of Skipper-CCD detectors

With Skipper-CCD detectors it is possible to take multiple samples of the charge packet collected on each pixel. After averaging the samples, the noise can be extremely reduced allowing the exact counting of electrons per pixel. In this work we present an analog circuit that, with a minimum number of components, applies a double slope integration (DSI) and at the same time averages the multiple samples, producing at its output the pixel value with sub-electron noise. For this purpose, we introduce the technique of using the DSI integrator capacitor to add the skipper samples. An experimental verification using discrete components is presented, together with an analysis of its noise sources and limitations. After averaging 400 samples it was possible to reach a readout noise of 0.18 e- rms/pix, comparable to other available readout systems. Due to its simplicity and significant reduction of the sampling requirements, this circuit technique is of particular interest in particle experiments and cameras with a high density of Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the first implementation of RF phase signature matching at LANSCE

The LINAC at the Los Alamos Neutron Science Center (LANSCE) has been utilizing the Delta-t method to match the RF cavities to the design acceleration parameters since its commissioning in 1972. The differences in time-of-flight between two subsequent Beam Position and Phase Monitors (BPPMs) are measured with both accelerated and drifting beams, depending on the whether the module is set to on or off. The algorithm optimizes the module amplitude and phase via iterative measurements if the initial phase is in the vicinity of the design value. With an upgrade to a faster readout system, a scan over the whole RF cavity phase range requires relatively less time than the classical optimization procedure. The Phase Scan Signature Matching (PSSM) method provides a time-efficient method that ensures the phase selection lands on the bunching side and empowers future analyses to build module-specific models. The PSSM also utilizes a direct model to determine the correct amplitude to sub-percent level instead of using linearized matrices. Furthermore, lacking a reliable energy measurement method in the LINAC, we measure the beam phases at two downstream locations to increase the precision of energy measurements. In this letter, we also discuss the sensitivities of PSSM, error propagation, and the implementation results for the 2019 and 2020 beam cycles.

47 OTHER INSTRUMENTATION↗

Machine learning on FPGA for event selection

Real-time data processing is a frontier field in experimental particle physics. The application of FPGAs at the trigger level is used by many current and planned experiments (CMS, LHCb, Belle2, PANDA). Usually they use conventional processing algorithms. LHCb has implemented Machine Learning (ML) elements for real-time data processing with a triggered readout system that runs most of the ML algorithms on a computer farm. The work described in this article aims to test the ML-FPGA algorithms for streaming data acquisition. Herein, there are many experiments working in this area and they have a lot in common, but there are many specific solutions for detector and accelerator parameters that are worth exploring further. This report describes the purpose of the work and progress in evaluating the ML-FPGA application.

47 OTHER INSTRUMENTATION↗

Development of a large array of Silicon Drift Detectors for high-rate synchrotron fluorescence spectroscopy

An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.

47 OTHER INSTRUMENTATION↗

Measurement of the directional sensitivity of Dark Matter Time Projection Chamber detectors

The dark matter time projection chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling 19 F and 12 C nuclei in low-pressure CF 4 gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30–60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (nondirectional) experiments, which measure only recoil energy. Furthermore assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10–20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3σ) confirmation that a candidate signal from a nondirectional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Radiation-Hard 8-Channel 15-Bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The custom design of a radiation-hardened, 8-channel, 40-MSPS, 15-bit resolution, 14.2-bit dynamic range, 11.4-ENOB ADC data acquisition ASIC fabricated in a commercial 65-nm triple-well CMOS technology is presented. The ADC is developed for and integrates seamlessly into the readout system for the ATLAS liquid argon (LAr) calorimeter in the high-luminosity large hadron collider (HLLHC) upgrade at CERN, which will require a total of 364 936 ADC channels. A three-stage MDAC+SAR pipelined ADC architecture was designed to meet the physics requirements and scientific goals of the ATLAS experiment. The ADC is a fully self-contained data acquisition system that includes foreground calibration, digital data processing, digital control, and supporting circuitry. The measured performance shows the ADC achieves a competitive dynamic range and SNDR, and it meets or exceeds the ATLAS analog requirements. Radiation tolerance and scalability design considerations were implemented at the device-, circuit-, and system-level. Radiation-hardening-by-design techniques used include redundancy for digital circuits, the use of MiM capacitors, and a hybrid RC-DAC for the ADC core. The ADC ASIC was demonstrated to be robust against the effects of the intense radiation expected in the HL-LHC experimental environment.

DAQ↗

A Charge Sensitive Pre-Amplifier for Smart Point-of-Care Devices Employing Polymer Based Lab-on-a-Chip

With increasing emphasis on implantable and portable medical devices, low-power, small-chip-area sensor readout system realized in lab-on-a-chip (LOC) platform is gaining more and more importance these days. The main building blocks of the LOC system include a front-end transducer that generates an electrical signal in response to the presence of an analyte of interest, signal processing electronics to process the signal to comply with a specific transmission protocol and a low-power transmitter, all realized in a single integrated circuit platform. Low power consumption and compactness of the components are essential requirements of the LOC system. This paper presents a novel charge sensitive pre-amplifier developed in a standard 180-nm CMOS process suitable for implementing in an LOC platform. The pre-amplifier converts the charge generated by a pyroelectric transducer into a voltage signal, which provides a measurement of the temperature variation in biological fluids. The proposed design is capable of providing 0.8-mV/pC gain while consuming only 2.1 μW of power. Finally, the pre-amplifier composed of integrated components occupies an area of 0.038 mm 2 .

36 MATERIALS SCIENCE↗

The GlueX Start Counter and Beam Asymmetry$\Sigma$ in Single $\pi^{0}$ Photoproduction

The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H 2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 10 8 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\vec{p}$→ π 0 p, where π 0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗