Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience

Abstract The frontend readout system for the silicon section of the CMS Phase II Endcap Calorimeter faces unique challenges due to the high channel count and associated bandwidth, limited physical space, as well as radiation tolerance requirements. I will give an overview of the frontend electronics design and will discuss the recent experience obtained from the first test system that integrates the HGCROC2 readout ASIC, lpGBT, and VTRX+ in a realistic manner, linking together prototypes of the hexaboard, engine, and wagon boards.

Instruments & Instrumentation↗

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Residual Optically Stimulated Luminescent (OSL) Signals for Al 2 O 3 :C and a Readout System with Reproducible Partial Signal Clearance

Optically stimulated luminescent dosimeters (OSLDs) are devices that, when stimulated with light, emit light in proportion to the integrated ionizing radiation dose. The stimulation of OSL material results in the loss of a small fraction of signal stored within the dosimetric traps. Previous studies have investigated the signal loss due to readout stimulation, and the optical annealing of OSLDs. This study builds on former research by examining the behavior of OSL signal after annealing, exploring the functionality of a previously developed signal loss model, and comparing uncertainties for dosimeters reused with or without annealing. For a completely annealed dosimeter, the minimum signal level was 56 ± 8 counts, and readings followed a Gaussian distribution. For dosimeters above this signal level, the fractional signal loss due to the reading process has a linear relationship with the calculated signal. At low signal levels (below 20,000 counts), in this OSLD system,calculated signal percent errors increase significantly but otherwise are on average 0.72 ± 0.27%, 0.40 ± 0.19%, 0.33±0.12%, and 0.24±0.07% for 30, 75, 150, and 300 readings. Theoretical calculations of uncertainties showed that annealing before reusing dosimeters allows for dose errors below 1% with as few as 30 readings. Reusing dosimeters multiple times increases the dose errors especially with low numbers of readouts, so theoretically around 300 readings would be necessary to achieve errors around 1% or below in most scenarios. Note that these dose errors do not include the error associated with the signal-to-dose conversion factor.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lifetime renormalization of driven weakly anharmonic superconducting qubits. II. The readout problem

Recent experiments in superconducting qubit systems have shown an unexpectedly strong dependence of the qubit relaxation rate on the readout drive power. This phenomenon limits the maximum measurement strength and thus the achievable readout speed and fidelity. We address this problem here and provide a plausible mechanism for drive-power dependence of relaxation rates. To this end we introduce a two-parameter perturbative expansion in qubit anharmonicity and the drive amplitude through a unitary transformation technique introduced in Part I. This approach naturally reveals number-nonconserving terms in the Josephson potential as a fundamental mechanism through which applied microwave drives can activate additional relaxation mechanisms. Here, we present our results in terms of an effective master equation with renormalized state- and drive-dependent transition frequency and relaxation rates. Comparison of numerical results from this effective master equation to those obtained from a Lindblad master equation which only includes number-conserving terms (i.e., Kerr interactions) shows that number-nonconserving terms can lead to significant drive-power dependence of the relaxation rates. The systematic expansion technique introduced here is of general applicability to obtaining effective master equations for driven-dissipative quantum systems that contain weakly nonlinear degrees of freedom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-Spin Readout and Quantum Sensing Using Optomechanically Induced Transparency

Solid-state spin defects are promising quantum sensors for a large variety of sensing targets. Some of these defects couple appreciably to strain in the host material. We propose to use this strain coupling for mechanically mediated dispersive single-shot spin readout by an optomechanically induced transparency measurement. Surprisingly, the estimated measurement times for negatively charged silicon-vacancy defects in diamond are an order of magnitude shorter than those for single-shot optical fluorescence readout. Here, our scheme can also be used for general parameter-estimation metrology and offers a higher sensitivity than conventional schemes using continuous position detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opportunities and challenges to study solar neutrinos with a Q-Pix pixel readout

The study of solar neutrinos presents significant opportunities in astrophysics, nuclear physics, and particle physics. However, the low-energy nature of these neutrinos introduces considerable challenges to isolate them from background events, requiring detectors with low-energy threshold, high spatial and energy resolutions, and low data rate. We present the study of solar neutrinos with a kiloton-scale liquid argon detector located underground, instrumented with a pixel readout using the Q-Pix technology. We explore the potential of using volume fiducialization, directional topological information, light signal coincidence, and pulse-shape discrimination to enhance solar neutrino sensitivity. We find that discriminating neutrino signals below 5 MeV is very difficult. However, we show that these methods are useful for the detection of solar neutrinos when external backgrounds are sufficiently understood and when the detector is built using low-background techniques. When building a workable background model for this study, we identify 𝛾 background from the cavern walls and from capture of 𝛼 particles in radon decay chains as both critical to solar neutrino sensitivity and significantly underconstrained by existing measurements. Finally, we highlight that the main advantage of the use of Q-Pix for solar neutrino studies lies in its ability to enable the continuous readout of all low-energy events with minimal data rates and manageable storage for further off-line analyses.

multi-purpose particle detectors↗

SOI-MEMS Bulk Piezoresistive Displacement Sensor: A Comparative Study of Readout Circuits

Performance of several readout circuits, when applied to a MEMS-based bulk piezoresistive displacement sensor is compared in this study. The sensor comprises a pair of tilted clamped-guided silicon beams whose bulk piezoresistivity is used for displacement sensing. Wheatstone half-bridge, constant-voltage, and constant-current circuits are implemented to measure resistance changes of this sensor. We report full characterization of the sensor with these circuits and explore the sensor’s important characteristics such as linearity, bandwidth, and noise. The results reveal that the constant-current circuit provides the highest sensitivity at equal-power bias condition. Here, we find that the resolution of the sensor is degraded from 1.6 nm with the Wheatstone half-bridge and constant-voltage circuits to about 4.2 nm with the constant-current configuration. In the frequency domain, the sensor captures the full dynamics of the MEMS nanopositioner up to 20 kHz with all readout circuits.

42 ENGINEERING↗

Development of flexible, scalable, low cost readout for beam tests of the high granularity calorimeter for the CMS endcap

As part of the development of the High Granularity Calorimeter for the CMS Endcap at HL-LHC, The CMS collaboration is conducting a comprehensive series of beam tests. The first beam test, with a single HGC module was carried out in March of 2016 at the Fermilab Test Beam Facility, continuing to a 16 module test in July of 2016. We describe here the development of a low cost readout system that is simple to implement and is able to grow with the system under test. The system is based on the low cost Zynq SoC that allows simple DAQ development in a Linux environment. For this application we used the Digilent ZedBoard, which allows high speed LVDS links and Linux software development on a single commercial board. A small custom FPGA board designed to comply with the VITA 57 Field Programmable Mezzanine Card standard implements the interface to the readout ASIC mounted on the HGC sensor modules and provides the LVDS links to the ZedBoard, either directly over the FMC connector or via a custom carrier card. This architecture provides scalability, ease of development and low cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Timing Properties for an Event Driven with Access and Reset Decoder Readout Architecture for a Pixel Array

The large number of data generating sources (data channels) on a single chip requires appropriate techniques to manage a readout from these channels. One of the main methods is sharing a medium of transmission, which requires arbitration to avoid collisions or deadlocks. Existing solutions face several problems such as a dead time, unintended prioritization or metastability. That is why we decided to create a new readout architecture named EDWARD i.e., Event Driven with Access and Reset Decoder. The EDWARD architecture gets rid of the earlier mentioned problems and mitigates the other ones. However, due to the use of logic circuits outside a standard cell library, which are hard to characterize, we were challenged to perform an additional transient analysis to validate the architecture. Here we show a methodology and the results of the simulations. Based on the results obtained we can confirm the functional correctness of the system and plan the optimization of operating conditions in order to achieve better performance. Our goal is to use the EDWARD architecture in the future radiation detectors to be built at Brookhaven National Laboratory.

47 OTHER INSTRUMENTATION↗

The readout system for the Clas12 Micromegas vertex tracker

In this paper, the architecture of the Clas12 Micromegas vertex tracker readout is described and the details of its implementation are given. The innovations allowing to meet the challenging requirements of the tracker operation are presented. The system performance is evaluated based on detector tests with a cosmic rays trigger and on standalone high rate validation tests. Finally, the perspectives to adapt the readout system or a part of it to other experiments are discussed.

Attie, D.↗

Commercially Fabricated Low Loss Superconducting Resonators Integrated With Detectors for Frequency Domain Multiplexing Readout of Future Cosmic Microwave Background Experiments

Planned Stage-IV cosmic microwave background (CMB) experiments call for telescopes with the order of 500 000 transition edge sensor (TES) bolometers. Such large arrays would benefit from detector multiplexing, as well as miniaturization and integration of readout components. Additionally, fabrication of micro-fabricated devices at a commercial foundry could potentially boost production rate and reduce overall cost. To this end, HYPRES, Inc., LBNL, and U.C. Berkeley are developing low loss, superconducting LC resonators integrated with antenna coupled TES bolometers for frequency multiplexing readout. The resonators are fabricated on the same wafer and are in the same process flow as the TES detectors, reducing size, weight, and wiring complexity of a detector module compared to the conventional design, where each component is fabricated separately. We have fabricated and tested resonators from 0.6 to 70 MHz, both as standalone devices and integrated with TES bolometers, all fabricated on 150- mm wafers. Finally, we discuss the design and fabrication of these devices and present measurements of the standalone resonators.

47 OTHER INSTRUMENTATION↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Readout Techniques for Very Large Arrays of Nuclear Sensors

During this project, we transformed the use of microwave readout techniques for nuclear sensors from a speculative idea to reality. The core of the project consisted of the development of a set of microwave electronics able to generate and process large numbers of microwave tones. The tones can be used to probe a circuit containing a series of electrical resonances whose frequency locations and widths depend on the state of a network of sensors, with one sensor per resonance. The amplitude and phase of the tones emerging from the circuit are processed by the same electronics and are reduced to the sensor signals after two demodulation steps. This approach allows a large number of sensors to be interrogated using a single pair of coaxial cables. We successfully developed hardware, firmware, and software to complete a scalable implementation of these microwave control electronics and demonstrated their use in two areas. First, we showed that the electronics can be used at room temperature to read out a network of diverse sensor types relevant to safeguards or process monitoring. Second, we showed that the electronics can be used to measure large numbers of ultrasensitive cryogenic sensors such as gamma-ray microcalorimeters. In particular, we demonstrated the undegraded readout of up to 128 channels and established a path to even higher multiplexing factors. These results have transformed the prospects for gamma-ray spectrometers based on cryogenic microcalorimeter arrays by enabling spectrometers whose collecting areas and count rates can be competitive with high purity germanium but with 10x better spectral resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating the SuperCDMS Dark Matter Detector Response and Readout

Dark matter is one of the remaining great mysteries of modern physics. Cosmological and astrophysical evidence hints strongly at a new particle, or set of particles, unknown to the Standard Model, comprising some 80% of all of the matter in the universe. SuperCDMS is one of the world-leading direct-detection experiments attempting to directly measure interactions between dark and regular matter. SuperCDMS uses solid state crystalline detectors in a nearly-zero background environment to attempt to measure the particle properties of dark matter. The detectors themselves, however, are quite complex; and a very detailed understanding of the microscopic physics is helpful in analyzing the very rare events that occur within them. Furthermore, better understanding and modeling of the detectors can aid in the design and optimization of future iterations of the experiment. The SuperCDMS detectors are well-understood in ideal cases. However, an accurate understanding of the detector response to outlier events or under non-ideal conditions is important for a low-statistics experiment. This work describes the design and implementation of a low temperature condensed matter physics simulation library built on top of the popular Geant4 particle tracking framework. The library, named \Geant4 Condensed Matter Physics" or G4CMP, introduces several solid state concepts to the Geant4 framework such as crystal lattices, phonon quasiparticles, non-scalar elective masses, and implements several physics processes relevant to cryogenic temperature crystals. In addition to the physics library, which is intended for general use, this work also describes a full Monte Carlo simulation package for the SuperCDMS iZIP detectors which utilizes G4CMP at its core and also fully simulates the detector readout sensors. The document will begin with the canonical motivations for the cold dark matter hypothesis, followed by a description of the SuperCDMS experiment. It will then describe the microscopic physics inside of the SuperCDMS detectors, as well as details on their implementation in G4CMP. The full detector simulation with corresponding sensor readout will follow, along with plans for future work; including both scientific studies and improvements, as well as computational improvements and added efficiencies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Evaluation of a Pixelated PSD-capable Scintillator Detector with SiPM Readout

We present the detector response comparison between a 10x10 pixellated array of scintillator read out with Anger logic using four 2" Hamamatsu R7724-100 super bialkali photomultiplier tubes (PMT) and a custom Silicon photomultiplier (SiPM) board consisting of 100 C-series 6x6 mm SiPMs from SensL. An array of these pixellated detectors are currently used in the Neutron Coded Aperture (NCA) imaging system. The energy, timing and pulse shape discrimination response using both readout schemes are presented, along with an analysis of multiple scatter events occurring within the block. An evaluation of the impact of photodetector readout on the overall detection efficiency and imaging accuracy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tile Detector with Wavelength Shifting Fiber Readout

At low beam intensity, ion chambers and the Digital Beam Imager are not able to produce a beam uniformity measurement. Plastic scintillator with PMT readout has been used to calibrate the beam in the past. The paper examines the use of scintillator tiles readout using wavelength shifting fibers and PMTs to create a low intensity device similar in function to the 256-pixel ion chamber for measuring the relative flux in 1x1 cm 2 regions over a 32 x 32 cm 2 area.

43 PARTICLE ACCELERATORS↗