Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Integration of EDWARD readout architecture in full-field fluorescence imaging detector

Data bandwidth, timing resolution and resource utilization in readouts of radiation detectors are a constant challenge. Event driven solutions are pushing against well-trenched framed solutions. The idea for an asynchronous readout architecture called EDWARD ( E vent- D riven W ith A ccess and R eset D ecoder) was presented at the TWEPP 2021 conference. Here we show the progress of our work which resulted in two chip prototypes. The first one, named 3FI65P1, is a full device with the analog pixel circuitry suited for full-field fluorescence imaging. It is already manufactured, and preliminary results are presented. Finally, the second chip, named EDWARD65P1, contains digital pulse generators with Poisson-exponential distribution in each pixel for extraction of the performance matrix of the EDWARD architecture alone.

47 OTHER INSTRUMENTATION↗

Embedded FPGA developments in 130 nm and 28 nm CMOS for machine learning in particle detector readout

Embedded field programmable gate array (eFPGA) technology allows the implementation of reconfigurable logic within the design of an application-specific integrated circuit (ASIC). This approach offers the low power and efficiency of an ASIC along with the ease of FPGA configuration, particularly beneficial for the use case of machine learning in the data pipeline of next-generation collider experiments. An open-source framework called "FABulous" was used to design eFPGAs using 130 nm and 28 nm CMOS technology nodes, which were subsequently fabricated and verified through testing. The capability of an eFPGA to act as a front-end readout chip was assessed using simulation of high energy particles passing through a silicon pixel sensor. A machine learning-based classifier, designed for reduction of sensor data at the source, was synthesized and configured onto the eFPGA. A successful proof-of-concept was demonstrated through reproduction of the expected algorithm result on the eFPGA with perfect accuracy. Finally, further development of the eFPGA technology and its application to collider detector readout is discussed.

47 OTHER INSTRUMENTATION↗

Readout electronics for low occupancy High-Pressure Gas TPCs

High-Pressure Gas Time Projection Chambers (HPgTPCs) have benefits such as low energy thresholds, magnetisability, and 4π acceptance, making them ideal for neutrino experiments such as DUNE. We present the design of an FPGA-based solution optimised for Gaseous Argon Near Detector (ND-GAr), which is part of the Phase-II more capable near detector for DUNE. These electronics reduce the cost significantly compared to using collider readout electronics, which are typically designed for much higher occupancy and therefore, for example, need much larger numbers of FPGAs and power per channel. We demonstrate the performance of our electronics with the Teststand for an Overpressurised Argon Detector (TOAD) at Fermilab in the US at a range of pressures and gas mixtures up to 4.5 barA, reading out ∼10 000 channels from a Multi-Wire Proportional Chamber (MWPC). The operation took place between April and July of 2024. We measure the noise characteristics of the system to be sufficiently low, and we identify sources of noise that can be further mitigated in the next iteration. We also note that the cooling scheme used in the test requires improvement before full-scale deployment. Despite these necessary improvements, we show that the system can fulfil the needs of a HPgTPC for a fraction of the price of collider readout electronics.

Data acquisition concepts↗

Radiation Tolerant Electronics and Digital Processing for the Phase-I Trigger Readout Upgrade of the ATLAS Liquid Argon Calorimeters

The high luminosities of L > 10{sup 34} cm{sup -2}s{sup -1} at the Large Hadron Collider (LHC) at CERN produce an intense radiation environment that the detectors and their electronics must withstand. The ATLAS detector is a multi-purpose apparatus constructed to explore the new particle physics regime opened by the LHC. Of the many decay particles observed by the ATLAS detector, the energy of the created electrons and photons is measured by a sampling calorimeter technique that uses Liquid Argon (LAr) as its active medium. The front end (FE) electronic readout of the ATLAS LAr calorimeter located on the detector itself consists of a combined analog and digital processing system. In order to exploit the higher luminosity while keeping the same trigger bandwidth of 100 kHz, higher transverse granularity, higher resolution and longitudinal shower shape information will be provided from the LAr calorimeter to the Level-l trigger processors. New trigger readout electronics have been designed for this purpose, which will withstand the radiation dose levels expected for an integrated luminosity of 3000 fb{sup -1} during the high luminosity LHC (HL-LHC), which is well above the original LHC design qualifications. (authors)

43 PARTICLE ACCELERATORS↗

Implementation of a Readout Circuit on SOI Technology for the Signal Conditioning of a Neutron Detector in Harsh Environment

A transistor level implementation of the analog block of a readout system on SOI process is presented here. This system is dedicated to the signal conditioning of a neutron detector in harsh environment. The different parts of the readout circuits are defined. The harsh environment constraints (crossing particle effect, high temperatures) are also detailed and modeled in the circuit in order to test and evaluate the characteristics of the designed block when working under these conditions. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sci—Fri PM: Dosimetry—01: Radiation-induced refraction artefacts in the optical CT readout of polymer gel dosimeters

Polymer gel dosimeters (PGDs) are a desirable tool for the verification of advanced radiotherapy treatments. Fully 3D, deformable, and tissue-equivalent, the PGD polymerizes wherever it absorbs dose. To measure the dose absorbed by a PGD, optical computed tomography (CT) can be used to evaluate, in full 3D, the opacity distribution that coincides with polymerization. In addition to an increase in opacity with dose, an increase in refractive index (RI) is also known to occur in irradiated polymer gels. The increase in RI is slight and was previously assumed insignificant. This work reveals the effects that radiation-induced RI changes can have on the optical CT readout of PGDs. A fan-beam optical CT scanner was used to image a cylindrical PGD irradiated by a pair of 3×3 cm{sup 2}, 6 MV photon beams in an orthogonal arrangement. Investigative scans were performed to evaluate refraction errors occurring: i) within the plane, and ii) out of the plane of the fan-beam. In-plane refraction was shown to cause distinct streaking artefacts along dose gradients (i.e. RI gradients) due to higher intensity rays being refracted into more opaque regions. Out-of-plane refraction was shown to produce severe, widespread artefacts due to rays missing the detector array. An iterative Savitzky-Golay filtering technique was developed to reduce both types of artefacts by specifically targeting structured errors in sinogram space. Results introduce a new category of imaging artefacts to be aware of when using optical CT for PGD readout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout system of TPC/MPD NICA project

The time-projection chamber (TPC) is the main tracking detector in the MPD/NICA. The information on charge-particle tracks in the TPC is registered by the MWPG with cathode pad readout. The frontend electronics (FEE) are developed with use of modern technologies such as application specific integrated circuits (ASIC), field-programmable gate arrays (FPGA), and data transfer to a concentrator via a fast optical interface. The main parameters of the FEE are as follows: total number of channels, ∼95 000; data stream from the whole TPC, 5 GB/s; low power consumption, less than 100 mW/ch; signal to noise ratio (S/N), 30; equivalent noise charge (ENC), <1000e{sup –} (C{sub in} = 10–20 pF); and zero suppression (pad signal rejection ∼90%). The article presents the status of the readout chamber construction and the data acquisition system. The results of testing FEE prototypes are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing novel techniques for readout, calibration and event selection in the NOvA long-baseline neutrino experiment

The NOvA long-baseline neutrino experiment uses a fine-grained, low-Z, fully active detector that offers unprecedented electron neutrino identification capabilities for a detector of its scale. In this award’s proposal, the PI outlined the development and implementation of novel techniques for channel readout, detector calibration, and event reconstruction that make full use of the strengths of the NOvA detector technology. In particular, this included designing custom event reconstruction algorithms that utilize the rich information available in the substructure of hadronic and electromagnetic showers. Exploiting this information provides not only substantial improvement in background rejection for the electron neutrino search but also better shower energy resolution (improving the precision on measured oscillation parameters) and a high-energy electromagnetic calibration source (through neutral pion events). The PI further proposed developing and deploying a new electronics readout scheme compatible with the existing hardware that can reduce near detector event pile-up and can offer powerful timing information to the reconstruction, allowing for cosmic ray muon tagging via track direction determination, among other things. In conjunction with the above, the PI proposed leading the calibration of the NOvA detectors, including characterizing individual electronics channels, correcting for spatial variations across the detector, and establishing absolute event energy scales. All three of these lines of effort have been successfully completed, feeding directly into the NOvA’s recent exciting neutrino oscillation results. The techniques developed under this award are detailed in this final technical report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.

42 ENGINEERING↗

Multiplexed Readout for an Experiment with a Large Number of Channels Using Single-Electron Sensitivity Skipper-CCDs

This paper presents the implementation of a multiplexed analog readout electronics system that can achieve single-electron counting using Skipper-CCDs with non-destructive readout. The proposed system allows the best performance of the sensors to be maintained, with sub-electron noise-level operation, while maintaining low-bandwidth data transfer, a minimum number of analog-to-digital converters (ADC) and low disk storage requirement with zero added multiplexing time, even for the simultaneous operation of thousands of channels. These features are possible with a combination of analog charge pile-up, sample and hold circuits and analog multiplexing. The implementation also aims to use the minimum number of components in circuits to keep compatibility with high-channel-density experiments using Skipper-CCDs for low-threshold particle detection applications. Performance details and experimental results using a sensor with 16 output stages are presented along with a review of the circuit design considerations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation-Hard Parallel Readout Circuit for Low-Frequency Voltage Signal Measurements

NASA Goddard Space Flight Center (GSFC) has successfully developed and tested a custom-designed low-noise multi-channel digitizer (MCD) application specific integrated circuit (ASIC) for operation in harsh radiation environments. The MCD-ASIC is optimized for low-frequency and low-voltage signal measurements from sensors and transducers. It has 20 input channels where each channel is comprised of auto-zeroed chopper variable-gain amplifier, post amplifier, and a second order ∑∆ modulator. ∑∆ analog-to-digital converter (ADC) relies on oversampling and noise shaping to achieve high-resolution conversion. However, the MCD-ASIC requires digital filtering and decimation to convert the output single bit streams from the ADC to useful data words. A parallel digital platform such as a field-programmable-gate-array (FPGA) is highly suitable to fully leverage the capabilities of the MCD-ASIC. The FPGA controls the MCD-ASIC via serial peripheral interface (SPI) protocol and acquires data from it. A Python-script communicates with the FPGA board through a USB interface on a cross operating platform. Using this architecture, the system is capable of monitoring up to 20 voltage readout channels simultaneously in a real-time manner. Each channel’s parameters can be programmed independently allowing maximum user versatility. In this paper, we present analysis of the analog front-end, the implementation of the digital processing unit on the FPGA, and provide noise performance results from the MCD-ASIC readout.

ASIC↗

Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays

Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.

Transition-edge sensors↗

Phase-I Trigger Readout Electronics Upgrade for the ATLAS Liquid-Argon Calorimeters

The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadronic shower shapes. Therefore, this paper presents the final designs of the new electronic elements, their custom electronic devices, the procedures used to validate their proper functioning, and the performance achieved during the commissioning of this system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kinetic Inductance Traveling Wave Amplifier Designs for Practical Microwave Readout Applications

Abstract A Kinetic Inductance Traveling Wave Amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly niobium titanium nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable performance in terms of gain, bandwidth, and compression power and frequently approach the quantum limit for noise. However, most KIT demonstrations have been isolated from practical device readout systems. Using a KIT as the first amplifier in the readout chain of an unoptimized microwave SQUID multiplexer coupled to a transition-edge sensor microcalorimeter, we see an initial improvement in the flux noise [1]. One challenge in KIT integration is the considerable microwave pump power required to drive the non-linearity. To address this, we have initiated efforts to reduce the pump power by using thinner NbTiN films and an inverted microstrip transmission line design. In this article, we present the new transmission line design, fabrication procedure, and initial device characterization—including gain and added noise. These devices exhibit over 10 dB of gain with a 3 dB bandwidth of approximately 5.5–7.25 GHz, a maximum practical gain of 12 dB, and typical gain ripple under 4 dB peak to peak. We observe an appreciable impedance mismatch in the NbTiN transmission line, which is likely the source of the majority of the gain ripple. Finally, we perform an initial noise characterization and demonstrate system-added noise of three quanta or less over nearly the entire 3 dB bandwidth.

Physics↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Mouse models of cancer-induced cachexia: Hind limb muscle mass and evoked force as readouts

The majority of patients with advanced cancer suffer from cachexia, a systemic wasting syndrome, which subsequently impacts the tolerance to anti-cancer treatments, response to therapy, quality of life, and eventually, survival. Despite a high unmet medical need, there is currently no specific remedy available for an effective treatment of cachexia and its sequelae. A key feature of cachexia is the inexorable loss of skeletal muscle mass, which constitutes a main contributor to body weight loss and progressive functional impairments. Therefore, it's crucial to identify early readouts to detect and monitor the loss of muscle mass and function to initiate appropriate treatments timely. }Here, we describe experimental cancer models using mouse (syngeneic) or human (xenograft) cancer cell lines with a rapid onset of tumor growth and cachexia. These models are easier to establish, monitor and reproduce compared to the genetically engineered mouse models currently available. Moreover, we establish readouts such as hind limb muscle mass and volume, as well as evoked force and food intake measurements, to allow the evaluation of potential therapeutic agents for the early treatment of cachexia and associated impairments.

60 APPLIED LIFE SCIENCES↗

Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

In this study, a new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

42 ENGINEERING↗