Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAMAN spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Development of a Raman lidar simulation tool

Raman Lidar is a useful and powerful tool for remote probing of the atmosphere. With Raman Lidars, one can accurately determine the identity and concentration of a particular molecular specie present in the atmosphere. We present the results from a program to develop a simulation capability of Raman Lidar systems for the remote detection of atmospheric gases and/or air polluting hydrocarbons. Our model, which integrates remote Raman spectroscopy with SPARTA's BACKSCAT atmospheric lidar simulation package, permits accurate determination of the performance of a Raman Lidar system. The accuracy with which our model operates is due to the accurate calculation, at any given excitation wavelength, of the differential scattering cross section for the molecular specie under investigation. We show excellent correlation of our calculated cross section data with experimental data from the published literature. In addition, the use of our BACKSCAT package, which provides a user friendly environment to define the operating conditions, provides an accurate calculation of the atmospheric extinction at both the excitation and Raman shifted wavelengths. Our code can be used to accurately predict the performance of a Raman Lidar system, the concentration and identification of a specie in the atmosphere, or the feasibility of making Raman measurements.

Grasso, R. J.↗

Raman scattering of InGaAs/InP grown by uniform radial flow epitaxy

Uniform radial flow epitaxy, a novel growth technique, has been used to grown InGaAs films on InP. Epitaxial layers above and below the critical thickness for the onset of slip were grown. Raman spectroscopy was used to characterize the quality of epitaxial layers, determine alloy composition, and measure the strain. Raman spectra from both pseudomorphic (strained) and relaxed (unstrained) InGaAs films were obtained at 300 and 80 K. The difference in the frequencies of their GaAs-like longitudinal optical phonons was used to calculate stress for the strained InGaAs/InP, leading to a direct formula for the evaluation of the layer stress.

Feng, Z. C.↗

[Methods Used for Monitoring Cure Reactions in Real-time in an Autoclave]

The goal of the research was to investigate methods for monitoring cure reactions in real-time in an autoclave. This is of particular importance to NASA Langley Research Center because polyimides were proposed for use in the High Speed Civil Transport (HSCT) program. Understanding the cure chemistry behind the polyimides would allow for intelligent processing of the composites made from their use. This work has led to two publications in peer-reviewed journals and a patent. The journal articles are listed as Appendix A which is on the instrument design of the research and Appendix B which is on the cure chemistry. Also, a patent has been awarded for the instrumental design developed under this grant which is given as Appendix C. There has been a significant amount of research directed at developing methods for monitoring cure reactions in real-time within the autoclave. The various research efforts can be categorized as methods providing either direct chemical bonding information or methods that provide indirect chemical bonding information. Methods falling into the latter category are fluorescence, dielectric loss, ultrasonic and similar type methods. Correlation of such measurements with the underlying chemistry is often quite difficult since these techniques do not allow monitoring of the curing chemistry which is ultimately responsible for material properties. Direct methods such as vibrational spectroscopy, however, can often be easily correlated with the underlying chemistry of a reaction. Such methods include Raman spectroscopy, mid-IR absorbance, and near-IR absorbance. With the recent advances in fiber-optics, these spectroscopic techniques can be applied to remote on-line monitoring.

Cooper, John B.↗

The Athena Raman Spectrometer

Raman spectroscopy provides a powerful tool for in situ mineralogy, petrology, and detection of water and carbon. The Athena Raman spectrometer is a microbeam instrument intended for close-up analyses of targets (rock or soils) selected by the Athena Pancam and Mini-TES. It will take 100 Raman spectra along a linear traverse of approximately one centimeter (point-counting procedure) in one to four hours during the Mars' night. From these spectra, the following information about the target will extracted: (1) the identities of major, minor, and trace mineral phases, organic species (e.g., PAH or kerogen-like polymers), reduced inorganic carbon, and water-bearing phases; (2) chemical features (e.g. Mg/Fe ratio) of major minerals; and (3) rock textural features (e.g., mineral clusters, amygdular filling and veins). Part of the Athena payload, the miniaturized Raman spectrometer has been under development in a highly interactive collaboration of a science team at Washington University and the University of Alabama at Birmingham, and an engineering team at the Jet Propulsion Laboratory. The development has completed the brassboard stage and has produced the design for the engineering model.

Wang, Alian↗

Surface Analysis of 4-Aminothiophenol Adsorption at Polycrystalline Platinum Electrodes

Formation of self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) on polycrystalline platinum electrodes has been studied by surface analysis and electrochemistry techniques. The 4-ATP monolayer was characterized by cyclic voltammetry (CV), Raman spectroscopy, reflection absorption infrared (RAIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) experiments give an idea about the packing quality of the monolayer. RAIR and Raman spectra for 4-ATP modified platinum electrodes showed the characteristic adsorption bands for neat 4-ATP indicating the adsorption of 4-ATP molecules on platinum surface. The adsorption on platinum was also evidenced by the presence of sulfur and nitrogen peaks by XPS survey spectra of the modified platinum electrodes. High resolution XPS studies and RAIR spectrum for platinum electrodes modified with 4-ATP indicate that molecules are sulfur-bonded to the platinum surface. The formation of S-Pt bond suggests that ATP adsorption gives up an amino terminated SAM. Thickness of the monolayer was evaluated via angle-resolved XPS (AR-XPS) analyses. Derivatization of 4-ATP SAM was performed using 16-Br hexadecanoic acid.

Rosario-Castro, Belinda I.↗

Coherent light scattering spectroscopy for supersonic flow measurements

A unified discussion on coherent light scattering spectroscopy and its spectral dependence on molecular gas velocity, temperature and density is presented. The feasibility of using coherent Raman spectroscopy techniques for nonintrusive measurements of supersonic flow parameters is demonstrated and recent laboratory as well as wind tunnel experiments are reviewed. In addition, the advantages of using coherent Rayleigh-Brillouin spectroscopy for measuring high pressure flows are discussed.

She, C. Y.↗

Analysis of Carbon/Carbon Fragments From the Columbia Tragedy

The extensive investigation following the Space Shuttle Orbiter Columbia accident of February 1, 2003 determined that hot gases entered the wing through a breach in the protective reinforced carbon/carbon (RCC) leading edge. In the current study, the exposed edges of the recovered RCC from the vicinity of the breach are examined with scanning electron microscopy and Raman spectroscopy. Electron microscopy of the exposed edges revealed regions of pointed carbon fibers, characteristic of exposure to high temperature oxidizing gases. The Raman technique relates the observed 1350 and 1580 to 1600 cm(-1) bands to graphitic dom ains and their corresponding temperatures of formation. Some of the regions showed evidence of exposure temperatures beyond 2700 ?C during the accident.

Tallant, David R.↗

Analysis of Direct Samples of Early Solar System Aqueous Fluids

Over the past three decades we have become increasingly aware of the fundamental importance of water, and aqueous alteration, on primitive solar-system bodies. Some carbonaceous and ordinary chondrites have been altered by interactions with liquid water within the first 10 million years after formation of their parent asteroids. Millimeter to centimeter-sized aggregates of purple halite containing aqueous fluid inclusions were found in the matrix of two freshly-fallen brecciated H chondrite falls, Monahans (1998, hereafter simply "Monahans") (H5) and Zag (H3-6) (Zolensky et al., 1999; Whitby et al., 2000; Bogard et al., 2001) In order to understand origin and evolution of the aqueous fluids inside these inclusions we much measure the actual fluid composition, and also learn the O and H isotopic composition of the water. It has taken a decade for laboratory analytical techniques to catch up to these particular nanomole-sized aqueous samples. We have recently been successful in (1) measuring the isotopic composition of H and O in the water in a few fluid inclusions from the Zag and Monahans halite, (2) mineralogical characterization of the solid mineral phases associated with the aqueous fluids within the halite, and (3) the first minor element analyses of the fluid itself. A Cameca ims-1270 equipped with a cryo-sample-stage of Hokkaido University was specially prepared for the O and H isotopic measurements. The cryo-sample-stage (Techno. I. S. Corp.) was cooled down to c.a. -190 C using liquid nitrogen at which the aqueous fluid in inclusions was frozen. We excavated the salt crystal surfaces to expose the frozen fluids using a 15 keV Cs+ beam and measured negative secondary ions. The secondary ions from deep craters of approximately 10 m in depth emitted stably but the intensities changed gradually during measurement cycles because of shifting states of charge compensation, resulting in rather poor reproducibility of multiple measurements of standard fluid inclusions of +/- 90 0/00(2 sigma) for delta D, and +/- 29 0/00 (2 sigma) for delta O-18. On the other hand, the reproducibility of Delta O-17 is plus or minus 8 /00 (2 sigma ) because the observed variations of isotope ratios follow a mass dependent fractionation law. Variations of delta D of the aqueous fluids range over sog,a 330(90; 2 sigma ) to +1200(90) 0/00 for Monahans and delta 300(96) 0/00 to +90(98)0/00 for Zag. Delta O-17 of aqueous fluids range over delta 16(22) 0/00 to +18(10) 0/00 for Monahans and +3(10) 0/00 to +27(11) 0/00 for Zag. These variations are larger than the reproducibility of standard analyses and suggest that isotope equilibria were under way in the fluids before trapping into halite. The mean values of delta D and Delta O-17 are +290 0/00 and +9 0/00, respectively. The mean values and the variations of these fluids are different from the representative values of ordinary chondrites, verifying our working hypothesis that the fluid inclusion-bearing halites were not indigenous to the H chondrite parent-asteroid but rather represent exogenous material delivered onto the asteroid from a separate cryovolcanically-active body. This initial isotopic work has demonstrated the feasibility of the measurements, but also revealed sample processing and analytical shortcomings that are now being addressed. Examination of solid mineral inclusions within Monahans and Zag halite grains by confocal Raman spectroscopy at the Carnegie Geophysical Laboratory has revealed them to be metal, magnetite, forsteritic olivine (Fo.98), macromolecular carbon (MMC), pyroxenes, feldspar with Raman spectral affinity to anorthoclase and, probably, fine-grained lepidocrocite (FeO(OH)). In addition, one inclusion features aliphatic material with Raman spectral features consistent with a mixture of short-chain aliphatic compounds. We have initiated analyses of the bulk composition of the fluids within the inclusions in Zag and Monahans halites at Virginia Tech by LA ICPMS using angilent 7500ce quadrupole ICPMS and a Lambda Physik GeoLas 193 nm excimer laser ablation system. Preliminary results reveal that the inclusion aqueous fluids contain highly charged cations of Ca, Mg and Fe. The minerals and compounds discovered thus far within Monahans/Zag halites are indicative of an originating body at least partly composed of unequilibrated anhydrous materials (high Fo olivine, pyroxenes, feldspars, possibly the metal) which were subjected to aqueous alteration (the halite parent brine) and containing a light organic component (the short-chain aliphatic compounds). This material was ejected from the originating body with little or no disruption, as evidenced with the presence of fluid inclusions. An actively geysering body similar to modern Enceladus (Postberg et al., 2011) may be a reasonable analogue in this respect. Also, the originating body should have been within close proximity to the H chondrite parent in order to generate the number of halite grains seen in Monahans and Zag. Other candidates for Monahans/Zag halite parent bodie(s) may include a young Ceres with its possible liquid ocean, or Main Belt comets.

Zolensky, Michael E.↗

Characterize Planetary Surfaces from a Single Point to a Large Area Using a Standoff Ultra-Compact µ-Raman Instrument

A standoff Ultra-Compact micro-Raman (SUCR) instrument is used for detection of minerals, organic, and biological materials in daylight and nighttime conditions. The standoff measurements from a SUCR instrument based on micro-Raman spectroscopy on a rover or lander platform is ideal for identifying various types of ices, minerals, organics and biogenic materials. The μ-Raman measurements can assist in determining the biological potential for habitability assessment of planetary bodies as well as amino acid detection for evidence of past or present life on Mars, Europa, and other solar bodies. The SUCR instrument is used to inspect minerals, organic, biomarkers, ice, and embedded materials inside ice, as well as to conduct Raman line scanning from a single point to a large area for standoff detection at a 6-cm target distance.

M Nurul Abedin↗

Characterization of Organic Materials in the Xenolithic Clasts in Sharps (H3.4) Meteorite Using Microraman Spectroscopy

Graphitization of carbon is an irreversible process which alters the structure of graphitic materials in response to the increase in metamorphic grade (temperature and/or pressure). Carbonaceous materials offer a reliable geothermometer as their Raman spectra change systematically with increasing metamorphic grade [1-3]. In this study, we identified carbonaceous materials in the xenolithic clasts in Sharps and interpreted their metamorphic history by revealing the structural organization (order) of the polyaromatic organic phases using μ-Raman spectroscopy.

Chan, Q. H. S.↗

Indigenous Carbonaceous Matter in the Nakhla Mars Meteorite

Detailed microanalysis of the Martian meteorite Nakhla has shown there are morphologically distinct carbonaceous features spatially associated with low-T aqueous alteration phases including salts and id-dingsite. A comprehensive suite of analytical instrumentation including optical microscopy, field emission scanning electron microscopy (FESEM), energy dispersive X-ray (EDX) spectroscopy, focused ion beam (FIB) microscopy, transmission electron microscopy (TEM), two-step laser mass spectrometry (mu-L(sup 2)MS), laser mu-Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), and nanoscale secondary ion mass spectrometry (NanoSIMS) are being used to characterize the carbonaceous matter and host mineralogy. The search for carbonaceous matter on Mars has proved challenging. Viking Landers failed to unambiguously detect simple organics at either of the two landing sites although the Martian surface is estimated to have acquired at least 10(exp15) kg of C as a consequence of meteoritic accretion over the last several Ga. The dearth of organics at the Martian surface has been attributed to various oxidative processes including UV photolysis and peroxide activity. Consequently, investigations of Martian organics need to be focused on the sub-surface regolith where such surface processes are either severely attenuated or absent. Fortuitously since Martian meteorites are derived from buried regolith materials they provide a unique opportunity to study Martian organic geochemistry.

Clemett, S. J.↗

Petrologic Sub-types, Sub-groups, and Pairing for CV Chondrites in the US Antarctic Meteorite Collection

Carbonaceous chondrites of the Vigarano group (CV) are primitive meteorites that provide a wealth of information about the early solar system, including constraints on chondrule formation, origin of calcium-aluminum inclusions, stability of organic compounds, and redox conditions. The US Antarctic meteorite collection contains 119 CV samples from 15 dense collection areas (DCAs) from the Trans-Antarctic Mountains. These samples have been assigned a preliminary classification as CVs, but have not been assigned to the subgroups Oxidized A, Oxidized B, and Reduced. Additionally, variation in petrologic grade can be determined non-destructively using Raman spectroscopy. In order to update classification of both subgroups and petrologic types in the collection, we have acquired magnetic susceptibility, metal and sulfide compositions, and Raman spectra, for as many samples as possible. We use the recent assessment and delineation of CV sub-groups of as a guide.

solar nebula↗

WOBBLE: A Proposed Mission to Characterize Past and Present Water on Mars

WOBBLE ("Water Observations from a Balloon Borne Light Explorer") is a mission concept study for a small robotic probe to explore Mars and to accomplish a scientific mission compatible with the goals of the NASA Code S enterprise. The detection of past or present water is a crucial goal for Mars exploration, representing a cross-cutting science theme relevant to past or extant life, climate history, sample return missions and eventual human exploration. The WOBBLE mission concept was developed to study evidence of water using in-situ detection methods. The features on Mars most suited to this investigation are the gullies identified by Malin and Edgett as evidence for recent, near-surface runoff of liquid water. These features are typically located on the inside face of crater rims, where the local slope angle is at or near the angle of repose. This makes the terrain difficult or impossible to access with conventional wheeled rover technology. Combined with the small size of the gullies in relation to a standard landing error ellipse, scientific investigation of these features requires a new approach to surface mobility. WOBBLE uses a low-altitude balloon-borne platform to traverse the surface from the landing site, to the investigation site, and then rise up the slope to investigate the regions of interest at close range. Of the mobility technologies available for near-term Mars exploration, only a balloon platform is capable of a well targeted, detailed sampling of the gully regions over periods of days or more. The science approach embodied in WOBBLE is two-pronged, designed to investigate both the historical evidence of liquid water utilizing high-resolution geomorphology and the characterization of mineral deposits, and present subsurface liquid water using radar sounding techniques. The WOBBLE balloon is a high-pressure hydrogen gas design, 24 meters in diameter and lifting a total payload of 130 kg, including a high-resolution camera/IR imager, Raman spectrometer, and a ground penetrating radar (GPR) sounder. The stowed balloon and payload are designed to fit within the current airbag delivery system being built for the Mars Exploration Rovers. Characterization of local meteorological conditions and wind is made over the initial sols following landing and before balloon inflation. Following balloon inflation and launch, a controlled, targeted approach toward the identified regions of interest is made in a series of several low-altitude "hops," with the balloon tethered to the ground between the hop intervals. A "snake" system is used to control the altitude to a few tens of meters above the local ground level. Enroute to the target gully, GPR soundings and Raman spectroscopy measurements study past or present water, while continued camera bearings and meteorological measurements refine the next "hop" trajectory. Once at the gully/outflow region, GPR and Raman soundings continue while the camera obtains detailed, approx. 0.5 cm images for geomorphology studies. The WOBBLE concept is applicable to Mars Scout, Mars Surveyor, or Discovery class missions.

Udrea, Bogdan↗

Raman Spectrometer for Surface Identification of Minerals and Organic Compounds on Silicate Planets and Small Solar-System Bodies

This summary is the final report of work on two-year grant. Our objectives for this project were (1) to demonstrate that Raman spectroscopy is an excellent method for determining mineralogy on the surface of the Moon, Mars, and other planetary bodies; (2) to construct a prototype of a small Raman spectrometer of the kind we suggest could be used on a lander or rover; and (3) to test the ability of that spectrometer to identify minerals and quantify mineral proportions in lunar materials and complex Martian analog materials, and to identify organic matter in planetary surface materials, all under roughly simulated field conditions. These goals have been met. The principal accomplishments of this PIDDP project have been the following: selection for flight; construction of a breadboard Raman probe; throughput confirmation of the breadboard Raman probe; selection of a laser; a breadboard spectrograph based on our PIDDP design; and overall result.

Haskin, Larry A.↗

Single Wall Nanotube Type-Specific Functionalization and Separation

Metallic single-wall carbon nanotubes were selectively solubilized in THF and separated from semiconducting nanotubes. Once separated, the functionalized metallic tubes were de-functionalized to restore their metallic band structure. Absorption and Raman spectroscopy of the enriched samples support conclusions of the enrichment of nanotube samples by metallic type. A scalable method for enriching nanotube conductive type has been developed. Raman and UV-Vis data indicate SWCNT reaction with dodecylbenzenediazonium results in metallic enrichment. It is expected that further refinement of this techniques will lead to more dramatic separations of types and diameters.

Boul, Peter↗

Ion produced cometary organic crust

For several years many experimental results have been obtained on the chemical and physical changes induced by ion and electron irradiation of materials with a view to their Astrophysical relevance. Among the studied effects, one of particular interest is the formation of an organic refractory residue left over after ion irradiation and warming-up at room temperature. We call this residue IPHAC (ion produced hydrogenated amorphous carbon). Although 'in situ' infrared spectroscopy points out the formation of new molecular species during bombardment at low temperature, it is not clear if IPHAC is already formed or if its formation is triggered by temperature increase during warming-up of the irradiated target. Since Raman Spectroscopy is a technique particularly suitable for the analysis of carbonaceous materials, we have thought and build-up an experimental apparatus to obtain Raman Spectra of frozen hydrocarbons during ion irradiation. The present experimental results point out clearly to the formation of IPHAC already at low T and low energy deposition (approximately equal to a few eV/C-atom).

Baratta, G. Antonio↗

Non-intrusive measurements in a rocket engine combustor

In recent years analytical tools to characterize combustor flow have been developed in order to support design. To facilitate anchoring of combustion related physical models and the CFD codes in which they are incorporated, considerable development and application of non-intrusive combustion diagnostic capabilities has occurred. Raman spectroscopy can be used to simultaneously detect all polyatomic molecules present in significant concentrations and to determine gas temperature. This is because all molecules possess a distinct temperature dependent Raman spectrum. A multi-point diagnostic system for non-intrusive temperature and species profiling in rocket engines has been developed at Rocketdyne. In the present effort, the system has been undergoing validation for application to rocket engine component testing. A 4 inch diameter windowed combustor with a coaxial gas-gas injector was chosen for this series of validation experiments. Initially an excimer-pumped tunable dye laser and later a solid state Nd-Yag laser served as excitation sources. The Raman signal was dispersed by a monochromator and detected by a gated, intensified Charged Coupled Device (CCD) array. Experiments were carried out prior to each series of hot fire tests to ensure that the Raman signal detected was due to a spontaneous rather than a stimulated Raman emission process. Over sixty hot fire tests were conducted during the first series of tests with the excimer/dye laser. All hot fire testing was at a mixture ratio of 0.5 and chamber pressures of approximately 100 and approximately 300 psia. The Raman spectra of hydrogen, water vapor and oxygen recorded during single element hot fire tests were reduced and analyzed. A significant achievement was the attainment of single shot Raman spectra in cold flow tests. Unfortunately, the single shot signal-to-noise ratio deteriorated to an unacceptable level during the hot fire testing. Attempts to obtain temperature data from the hydrogen Q1-branch profiles obtained in hot fire tests suggest that potentially complicating factors may render the approach of averaging data on the photodiode array invalid. A second series of hot fire tests was conducted with a 4 element coaxial injector using the Nd-Yag laser. A very compact and portable diagnostics set up was assembled for ease of alignment, relocation and flexibility. Measurements were made at several regions in the chamber in order to map concentration profiles. High spatial resolution and improved signal to noise characteristics were demonstrated.

Farhangi, S.↗

Small Business Innovations

Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.

Source record↗