BEYONDPLANCK XI. Bayesian CMB analysis with sample-based end-to-end error propagation

We present posterior sample-based cosmic microwave background (CMB) constraints from Planck LFI and WMAP observations as derived through global end-to-end Bayesian processing within the BeyondPlanck framework. We first use these samples to study correlations between CMB, foreground, and instrumental parameters, and we identify a particularly strong degeneracy between CMB temperature fluctuations and free-free emission on intermediate angular scales (400 ≲ ℓ ≲ 600), which is mitigated through model reduction, masking, and resampling. We compare our posterior-based CMB results with previous Planck products, and find generally good agreement, although with notably higher noise due to our exclusion of HFI data. We find a best-fit CMB dipole amplitude of 3362.7 ± 1.4 µK, in excellent agreement with previous Planck results. The quoted dipole uncertainty is derived directly from the sampled posterior distribution, and does not involve any ad hoc contributions for Planck instrumental systematic effects. Similarly, we find a temperature quadrupole amplitude of ${σ}_{2}^{TT}$ = 229 ± 97 µK 2 , which is in good agreement with previous results in terms of the amplitude, but the uncertainty is an order of magnitude larger than the naive diagonal Fisher uncertainty. Relatedly, we find lower evidence for a possible alignment between the quadrupole and octopole than previously reported due to a much larger scatter in the individual quadrupole coefficients, caused both by marginalizing over a more complete set of systematic effects, but also by our more conservative analysis mask required to mitigate the free-free degeneracy. For higher multipoles, we find that the angular temperature power spectrum is generally in good agreement with both Planck and WMAP. At the same time, we note that this is the first time the sample-based asymptotically exact Blackwell-Rao estimator has been successfully established for multipoles up to ℓ ≤ 600, and it now accounts for the majority of the cosmologically important information. Overall, this analysis demonstrates the unique capabilities of the Bayesian approach with respect to end-to-end systematic uncertainty propagation, and we believe it can and should play an important role in the analysis of future CMB experiments. Cosmological parameter constraints are presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Discovery of multiple p-mode pulsation frequencies in the roAp star, HD 86181

ABSTRACT We report the frequency analysis of a known roAp star, HD 86181 (TIC 469246567), with new inferences from Transiting Exoplanet Survey Satellite (TESS) data. We derive the rotation frequency to be νrot = 0.48753 ± 0.00001 d−1. The pulsation frequency spectrum is rich, consisting of two doublets and one quintuplet, which we interpret to be oblique pulsation multiplets from consecutive, high-overtone dipole, quadrupole, and dipole modes. The central frequency of the quintuplet is 232.7701 d−1 (2.694 mHz). The phases of the sidelobes, the pulsation phase modulation, and a spherical harmonic decomposition all show that the quadrupole mode is distorted. Following the oblique pulsator model, we calculate the rotation inclination, i, and magnetic obliquity, β, of this star, which provide detailed information about the pulsation geometry. The i and β derived from the best fit of the pulsation amplitude and phase modulation to a theoretical model, including the magnetic field effect, slightly differ from those calculated for a pure quadrupole, indicating the contributions from ℓ = 4, 6, 8,... are small. Non-adiabatic models with different envelope convection conditions and physics configurations were considered for this star. It is shown that models with envelope convection almost fully suppressed can explain the excitation at the observed pulsation frequencies.

Shi, Fangfei (ORCID:0000000323998216)↗

Exploring the role of high- j configurations in collective observables through the Coulomb excitation of 106 Cd

In this work, the shape and collectivity of 106 Cd was investigated via a sub-barrier-energy Coulomb excitation experiment performed at the NSCL ReA3 facility using the JANUS setup. Transition matrix elements between low-lying states were found to agree with adopted values, and information on the shape and collectivity of higher-lying states was extracted for the first time. Locally-optimized large-scale shell-model calculations were found to describe well the B(E2) transition strengths but failed to reproduce the spectroscopic quadrupole moments Q s . An analysis of the E2 rotational invariants and the normalized quadrupole moment q s indicates that this may be due to a significant degree of triaxiality in 106 Cd which is not captured by the present shell-model calculations. Analogous calculations for the Fe isotopes (two protons below the Z = 28 magic number) reveal the critical role of high-j neutron configurations for the description of quadrupole moments in the heavy Fe and Cd isotopes (two protons below magic Z = 50), but this effect is insufficient to explain the shape of 106 Cd, posing a puzzle for the understanding of nuclear structure towards N = 50.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of Hexadecapole Deformation in Uranium-238 at the Relativistic Heavy Ion Collider

State-of-the-art hydrodynamic simulations of the quark-gluon plasma are unable to reproduce the elliptic flow of particles observed at the BNL Relativistic Heavy Ion Collider (RHIC) in relativistic 238 U + 238 U collisions when they rely on information obtained from low-energy experiments for the implementation of deformation in the colliding 238 U ions. Here, we show that this is due to an inappropriate treatment of well-deformed nuclei in the modeling of the initial conditions of the quark-gluon plasma. Past studies have identified the deformation of the nuclear surface with that of the nuclear volume, though these are different concepts. In particular, a volume quadrupole moment can be generated by both a surface hexadecapole and a surface quadrupole moment. This feature was so far neglected in the modeling of heavy-ion collisions, and is particularly relevant for nuclei like 238 U, which is both quadrupole deformed and hexadecapole deformed. With rigorous input from Skyrme density functional calculations, we show that correcting for such effects in the implementation of nuclear deformations in hydrodynamic simulations restores agreement with BNL RHIC data. This brings consistency to the results of nuclear experiments across energy scales, and demonstrates the impact of the hexadecapole deformation of 238 U on high-energy collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of MQXF Quench Heater Insulation Strength and Test of Modified Design

The HL-LHC interaction region magnet triplets (Q1,Q2, and Q3) will be composed of superconducting Nb 3 Sn quadrupoles. The MQXF quadrupole protection system is based on CLIQ (Coupling-Loss Induced Quench system) and outer layer quench heaters. Furthermore, this paper reports a summary of quench heaters to coil high voltage tests performed on MQXF short and long coils in air after fabrication, and in air and He gas after magnet training. Breakdown voltage values demonstrate good margin with respect to the Electrical design criteria for the HL-LHC inner triplet mag-nets. A modification in the quench heater installation-with an extra layer of fiber glass between the coil and the quench heater trace-has been proposed and tested in a mirror magnet to further increase electrical margins. Results demonstrated improvements of high voltage margin at the expense of a clear increase of hot spot temperature.The baseline heater to coil insulation was assessed to be able to guarantee safe operation for the Nb 3 Sn quadrupole magnets for the interaction regions of HL-LHC.

43 PARTICLE ACCELERATORS↗

A Metallurgical Inspection Method to Assess the Damage in Performance-Limiting Nb 3 Sn Accelerator Magnet Coils

The design and production of Nb 3 Sn-based dipole and quadrupole magnets is critical for the realization of the High-Luminosity Large Hadron Collider (HL-LHC) at the European Organization for Nuclear Research (CERN). Nb 3 Sn superconducting coils are aimed at enhancing the bending and focusing strengths of accelerator magnets for HL-LHC and beyond. Due to the brittle nature of Nb 3 Sn, the coil fabrication steps are very challenging and require very careful QA/QC. Flaws in the Nb 3 Sn filaments may lead to quenches, and eventually, performance limitation below nominal during magnet testing. A novel inspection method, including advanced non-destructive and destructive techniques, was developed to explore the root-causes of quenches occurring in performance-limiting coils. The most relevant results obtained for MQXF coils through this innovative inspection method are presented. This approach allows for precise assessment of the physical events associated to the quenches experienced b y magnet coils, mainly occurring under the form of damaged strands with transversely broken sub-elements. Coil-slice preparation, micro-optical observations of transverse and longitudinal cross-sections, and a deep etching technique of copper will be illustrated in the present work, with a focus on the results achieved for a CERN coil from a non-conforming quadrupole magnet prototype, and two coils fabricated in the US, in the framework of the Accelerator Upgrade Project (AUP) collaboration, from two different non-conforming quadrupole magnets, respectively. The results obtained through the proposed inspection method will be illustrated.

43 PARTICLE ACCELERATORS↗

Alternative solenoid compensation scheme for the FCC-ee interaction region

We present the optics design of the solenoid compensation scheme at the FCC-ee. The 2T solenoids from the experiments induce coupling on the beams, generating an increase on vertical emittance. This compensation scheme minimizes emittance growth, with a final value of approximately 5% of the nominal. A screening solenoid is placed around the Final Focus Quadrupoles to protect them from the experiment’s field. A skew quadrupole component is added to the Final Doublet, aligning the magnet axis to the rotated reference frame of the beam. Two anti-solenoids placed approximately ±20 m from the IP are used to cancel the field integral. The vertical orbit generated by the horizontal crossing angle in the detector field is compensated by vertical correctors placed right after the beam pipe separation and next to the final focus quadrupoles. We describe the IR optics in this scheme, including the detector solenoid and the magnetic elements used for compensation.

43 PARTICLE ACCELERATORS↗

Optics reconstruction in the SCL section of the FNAL Linac

The Side-Coupled Linac (SCL) section of the FNAL linac accelerates the beam from 116 MeV to 401.5 MeV, operating at 22-24 mA beam current. Transverse focusing is performed by 32 quadrupoles, and the beam orbit is guided by 19 dipole correctors and measured by 29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings of an upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code TraceWin. A comparison between TraceWin simulations and the beam envelope measured by the 12 wire scanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance and exit of the SCL section will be reported.

Carneiro, Jean-Paul [Fermilab]↗

Phenomenological study on correlation between flow harmonics and mean transverse momentum in nuclear collisions

To assess the properties of the quark-gluon plasma formed in nuclear collisions, the Pearson correlation coefficient between flow harmonics and mean transverse momentum, \rho\left(v_{n}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v n 2 , [ p T ] ) , reflecting the overlapped geometry of colliding atomic nuclei, is measured. \rho\left(v_{2}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v 2 2 , [ p T ] ) was found to be particularly sensitive to the quadrupole deformation of the nuclei. We study the influence of the nuclear quadrupole deformation on \rho\left(v_{n}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v n 2 , [ p T ] ) in Au+Au and U+U collisions at RHIC energy using AMPT transport model, and show that the \rho\left(v_{2}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v 2 2 , [ p T ] ) is reduced by the quadrupole deformation \beta_2 β 2 and turns to change sign in ultra-central collisions (UCC).

Zhang, Chunjian↗

Development of Improved Noble Liquid Purity Measurements (Final Technical Report)

The main goal of the Detector R&D project supported by this grant, “Development of Improved Noble Liquid Purity Measurements”, was to perform a scoping study of the feasibility of trapping ions in a liquid argon medium using a radiofrequency (RF) quadrupole trap, and to subsequently use the population of trapped ions to make measurements of the properties of the liquid medium. Using RF quadrupole traps immersed in a noble liquid to trap ions may yield new capabilities to detect and quantify the presence of impurities, as well as enabling other measurements of the microphysics in a noble liquid environment. The major activities undertaken during this project include: the development of a simulation of ions in a liquid argon medium; the designing of a prototype RF quadrupole trap; and the setup of hardware to be used in testing the prototype in vacuum and gas conditions. The summary of these major activities is reported here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High current, high-temperature operation test of the superconducting magnets in the RHIC yellow ring

We report on the tests conducted at the end of RHIC Run 21 to evaluate the operation of superconducting magnets in the RHIC yellow ring at higher currents – up to 5500 A for the arc dipoles and all other magnets on the dipole bus and the focusing arc quadrupoles, up to 5750 A for defocusing arc quadrupoles and up to 6000 A for the insertion quadrupoles Q1 through Q9 – and higher temperatures – up to 5.1 K – than routine. None of the magnets quenched. This is an encouraging finding as the superconducting magnet coils could reach up to 4.9 K during operation with the 275 GeV EIC hadron beams.

43 PARTICLE ACCELERATORS↗

US HL-LHC Accelerator Upgrade Project (MQXFA Final Design Report)

The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.

43 PARTICLE ACCELERATORS↗

Secondary Beamline Lattice Design at the MeV Test Area (MTA)

The MTA is currently configured to produce a secondary pion beam from a tungsten target, which subsequently generates muons from decay in flight. In its present lattice configuration, the currently installed air core quadrupoles are strength-limited in their ability to deliver a high muon flux to the end user. Recently, seven strong iron-core quadrupole spares from the 400-MeV Linac were acquired. Based on these quadrupoles, a new lattice has been designed that maximizes both pion transport and muon capture the line based on significantly shorter magnetic lengths, strong magnetic gradients, and consequently an enhanced angular acceptance. For this project, we demonstrated that the ratio of muons to pions increased by over an order of magnitude (approximately 75 for lattice configurations were studied), successfully capturing a phase space area as large as 13.2 [mm] x 24 [mRad] in simulation.

Winter, Wesley↗

Optics Reconstruction in the SCL Section of the FNAL Linac

The Side-CoupledLinac (SCL) section oftheFNAL linac acceleratesthe beamfrom 117 MeV to 401.5 MeV, operatingat 22-24mA beam current. Transverse focusing is performedby32 quadrupoles, and the beam orbit is guidedby19dipolecorrectors andmeasuredby29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings o fan upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code Trace Win. A comparison between Trace Win simulations and the beam envelope measured bythe12wirescanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance of the transition section will be reported

Carneiro, Jean-Paul [Fermilab]↗

Measurement of the Energy Spread for CeC Project

The Coherent Electron Cooling requires small energy spread and uniformity of energy along the bunch. The diagnostics line is utilized for the measurement of the electron beam parameters. The beamline layout is shown in Fig. 1. Three quadrupoles after the linac are used to match beam into the common section. The main dipole is used to deflect beam towards common section. If it is switched off the beam goes to the diagnostics line. The beam optics in the diagnostics line is controlled by four quadrupoles. The deflecting cavity sweeping beam in the vertical direction follows the quadrupoles. Sector dipole is used for energy parameters measurement. It has deflection angle of 30 degrees. With diagnostics dipole switched off the beam propagated to the insertable slits system for emittance measurement. There are four profile monitors in the line, The first profile monitor (ACC YAG) is after the main dipole. The second profile monitor (YAG3) is in front of the diagnostics dipole after the deflecting cavity. YAG1 profile monitor is placed after the slits, and YAG2 profile monitor is placed after the diagnostics dipole. There is a solenoid between the deflecting cavity and YAG3. It is used for the beam energy measurement.

43 PARTICLE ACCELERATORS↗

Left-right canted-cosine-theta magnets

Disclosed herein are superconducting gantry magnets that include multiple quadrupole winding sections placed in sequence on a curve such that the effective current direction is reversed between sections. This produces alternating quadrupole field regions along the length of the bend whose individual integral strengths can be tuned by the location of the current polarity transitions. A simple transition scheme to reverse the current between sections can be implemented to allow for the use of one continuous winding and power supply. Dipole windings can be included in the superconducting gantry magnets so that the magnets produce superposed dipole and alternating quadrupole fields. The disclosed design for the windings and transition scheme to reverse current polarity can be implemented for higher order multipoles as well.

43 PARTICLE ACCELERATORS↗

Theory of Beam Echoes

We develop the theory of beam echoes in circular accelerators under several different conditions. We derive detailed expressions for the echo amplitude and pulse width with nonlinear quadrupole and dipole kicks, first without and then with momentum spread. We use the theory with the linearized dipole and quadrupole kicks to solve the diffusion equation for different dependencies of the diffusion coefficient on the action. We then consider the use of multiple quadrupole kicks to increase the maximum echo amplitude. We have extended these calculations partially to the 2D case and we also have partial results for longitudinal echoes.

43 PARTICLE ACCELERATORS↗