Multimodal x-ray and electron microscopy of the Allende meteorite
Soft x-ray ptychography of Allende meteorite around Fe L3-edge (707 eV), Ni L2/3-edge (865/848 eV), Mg K-edge (1,302 eV), and Al K-edge (1,551 eV)
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Soft x-ray ptychography of Allende meteorite around Fe L3-edge (707 eV), Ni L2/3-edge (865/848 eV), Mg K-edge (1,302 eV), and Al K-edge (1,551 eV)
Illumination retrieval in scanning diffractive imaging a.k.a. ptychography is challenging when the specimen is weakly scattering or surrounded by empty space. We describe a rank-1 acceleration method for weakly scattering or piecewise smooth specimens.
Ptychography promises diffraction limited resolution without the need for high resolution lenses. To achieve high resolution one has to solve the phase problem for many partially overlapping frames. Here we review some of the existing methods for solving ptychographic phase retrieval problem from a numerical analysis point of view, and propose alternative methods based on numerical optimization.
The coherent soft x-ray and full polarization control (CSX) beamline at the National Synchrotron Light Source - II (NSLS-II) will deliver 1013 coherent photons per second in the energy range of 0.2-2 keV with a resolving power of 2000. The source, a dual elliptically polarizing undulator (EPU), and beamline optics should be optimized to deliver the highest possible coherent flux in a 10-30 {micro}m spot for use in coherent scattering experiments. Using the computer code Synchrotron Radiation Workshop (SRW), we simulate the photon source and focusing optics in order to investigate the conditions which provide the highest usable coherent intensity on the sample. In particular, we find that an intermediate phasing magnet is needed to correct for the relative phase between the two EPUs and that the optimum phase setting produces a spectrum in which the desired wavelength is slightly red-shifted thus requiring a larger aperture than originally anticipated. This setting is distinct from that which produces an on-axis spectrum similar to a single long undulator. Furthermore, partial coherence calculations, utilizing a multiple electron approach, indicate that a high degree of spatial coherence is still obtained at the sample location when such an aperture is used. The aperture size which maximizes the signal-to-noise ratio of a double-slit experiment is explored. This combination of high coherence and intensity is ideally suited for x-ray ptychography experiments which reconstruct the scattering density from micro-diffraction patterns. This technique is briefly reviewed and the effects on the image quality of proximity to the beamline focus are explored.
Here, the present review discusses the current state of the art microscopic and spectroscopic characterization techniques available to study surfaces and interfaces under working conditions. Microscopic techniques such as environmental transmission electron microscopy and in situ transmission electron microscopy are first discussed showing their applications in the field of nanomaterials and catalysis. Next sum frequency generation vibrational spectroscopy is discussed, giving probing examples of surface studies in gaseous conditions. Synchrotron based X-ray techniques are also examined with a specific focus on ambient pressure X-ray photoelectron and absorption techniques such as near and extended X-ray absorption fine structure. Each of the techniques is evaluated, whilst the pros and cons are discussed in term of surface sensitivity, spatial resolution and/or time resolution. The second part of the articles is articulated around the future of in situ characterization, giving examples of the probable development of the discussed techniques as well as an introduction of emerging tools such as scanning transmission X-ray microscopy, ptychography, and X-ray photon correlation spectroscopy.
Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.
The measurement of optical ultrafast laser pulses is done indirectly because the required bandwidth to measure these pulses exceeds the bandwidth of current electronics. As a result, this measurement problem is often posed as a 1-D phase retrieval problem, which is fraught with ambiguities. The phase retrieval method known as ptychography solves this problem by making it possible to measure ultrafast pulses in either the time domain or the frequency domain. One well known algorithm is the principal components generalized projections algorithm (PCGPA) for extracting pulses from Frequency-Resolved Optical Gating (FROG) measurements. In this work, we discuss the development of the PCPGA and introduce new developments including an operator formalism that allows for the convenient addition of external constraints and the development of more robust algorithms. A close cousin, the ptychographic iterative engine will also be covered and compared to the PCGPA. Additional developments using other algorithmic strategies will also be discussed along with new developments combining optics and high-speed electronics to achieve megahertz measurement rates.
We discuss a method for recovering complex structure factors from many simultaneously excited Bragg beam intensities is described. The method is applied to simulated transmission electron diffraction data over a wide range of crystal thickness and beam energies. The method is based on iterated projections between structure and scattering matrices, which are related by a matrix unitary transformation, exponential, which we invert. The algorithm removes multiple-scattering perturbations from diffraction data and might be extended to other fields, including X-ray and neutron diffraction and cryo-electron microscopy. Because coherent multiple scattering involves interference between Bragg beams, the method also solves the phase problem. Unlike dynamical inversion from electron microscope images or ptychography data, the method, which starts with Bragg beam intensities, provides complex structure factors unaffected by focusing errors or resolution limitations imposed by lenses. We provide inversions from simulated data with 441 simultaneously excited Bragg beams over a range of thickness and beam energy. We discuss the retrieval of chirality information from enantiomorphs, the efficient incorporation of symmetry information using the irreducible representation of the group of structure matrices, and the effect of HOLZ lines to provide three-dimensional information.
Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.
Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.
Developing novel catalysts with high efficiency and selectivity is critical for enabling future clean energy conversion technologies. Interfaces in catalyst systems have long been considered the most critical factor in controlling catalytic reaction mechanisms. Interfaces include not only the catalyst surface but also interfaces within catalyst particles and those formed by constructing heterogeneous catalysts. The atomic and electronic structures of catalytic surfaces govern the kinetics of binding and release of reactant molecules from surface atoms. Interfaces within catalysts are introduced to enhance the intrinsic activity and stability of the catalyst by tuning the surface atomic and chemical structures. Examples include interfaces between the core and shell, twin or domain boundaries, or phase boundaries within single catalyst particles. In supported catalyst nanoparticles (NPs), the interface between the metallic NP and support serves as a critical tuning factor for enhancing catalytic activity. Surface electronic structure can be indirectly tuned and catalytically active sites can be increased through the use of supporting oxides. Additionally, tuning interfaces in catalyst systems has been identified as an important strategy in the design of novel catalysts. However, the governing principle of how interfaces contribute to catalyst behavior, especially in terms of interactions with intermediates and their stability during electrochemical operation, are largely unknown. This is mainly due to the evolving nature of such interfaces. Small changes in the structural and chemical configuration of these interfaces may result in altering the catalytic performance. These interfacial arrangements evolve continuously during synthesis, processing, use, and even static operation. A technique that can probe the local atomic and electronic interfacial structures with high precision while monitoring the dynamic interfacial behavior in situ is essential for elucidating the role of interfaces and providing deeper insight for fine-tuning and optimizing catalyst properties.Scanning transmission electron microscopy (STEM) has long been a primary characterization technique used for studying nanomaterials because of its exceptional imaging resolution and simultaneous chemical analysis. Over the past decade, advances in STEM, that is, the commercialization of both aberration correctors and monochromators, have significantly improved the spatial and energy resolution. Imaging atomic structures with subangstrom resolution and identifying chemical species with single-atom sensitivity are now routine for STEM. These advancements have greatly benefitted catalytic research. For example, the roles of lattice strain and surface elemental distribution and their effect on catalytic stability and reactivity have been well documented in bimetallic catalysts. In addition, three-dimensional atomic structures revealed by STEM tomography have been integrated in theoretical modeling for predictive catalyst NP design. Recent developments in stable electronic and mechanical devices have opened opportunities to monitor the evolution of catalysts in operando under synthesis and reaction conditions; high-speed direct electron detectors have achieved sub-millisecond time resolutions and allow for rapid structural and chemical changes to be captured. Investigations of catalysts using these latest microscopy techniques have provided new insights into atomic-level catalytic mechanisms. Further integration of new microscopy methods is expected to provide multidimensional descriptions of interfaces under relevant synthesis and reaction conditions.In this Account, we discuss recent insights on understanding catalyst activity, selectivity, and stability using advanced STEM techniques, with an emphasis on how critical interfaces dictate the performance of precious metal-based heterogeneous catalysts. The role of extended interfacial structures, including those between core and shell, between separate phases and twinned grains, between the catalyst surface and gas, and between metal and support are discussed. We also provide an outlook on how emerging electron microscopy techniques, such as vibrational spectroscopy and electron ptychography, will impact future catalysis research.
Functional porous materials are of mounting significance in energy conversion and catalysis. Improved analysis is needed to guide optimization. Four-dimensional (4D) imaging [chemical mapping in three-dimensional (3D) by spectro-tomography] of an Al 2 O 3 aerogel coated with ZnO by atomic layer deposition was performed using soft X-ray ptychography at the Zn L-edge. A two-dimensional spatial resolution of 14(2) nm was achieved. Visualizations of the 3D chemical structure are provided. The degree of ZnO coverage of the surface of the Al 2 O 3 aerogel framework in two different samples was estimated and found to be both thicker and less homogeneous than expected. Other analyses of the 4D results, including the degree of contact between Al 2 O 3 and ZnO, were extracted from the reconstructed 3D data. This pioneering soft X-ray spectro-ptycho-tomography research will anchor further studies of functional porous materials.
Single-atom electrocatalysts consisting of metal atoms embedded in a carbon matrix are promising next-generation catalysts for green hydrogen production and utilization, CO2 reduction, low-temperature CO oxidation, ammonia production, plastic decomposition, and electrochemical energy storage. The origins of activity and stability for the single-atom sites are still debatable, however, because of constrained insights into their local structure resulting from idealized models and experiments derived from a large number of individual sites. Insights into structural variations around single atomic sites are therefore critical for the continued development of these next-generation catalysts. While electron microscopy commonly provides atomic-scale information about these materials, the beam sensitivity of individual sites makes structural determination by conventional low-voltage (60 keV) techniques challenging. Here, we introduce ultralow-voltage electron ptychography, performed at 30 keV, that enables determination of the lattice structure around individual metal sites in a well-defined single-atom electrocatalyst system while essentially eliminating knock-on structural modifications. Pairing these atomic-scale, site-specific measurements with computational methods will broaden our understanding of the activity and stability of these materials, which will accelerate the development of the next generation of catalysts.
Due to their short wavelength, X-rays can in principle be focused down to a few nanometres and below. At the same time, it is this short wavelength that puts stringent requirements on X-ray optics and their metrology. Both are limited by today’s technology. In this work, we present accurate at wavelength measurements of residual aberrations of a refractive X-ray lens using ptychography to manufacture a corrective phase plate. Together with the fitted phase plate the optics shows diffraction-limited performance, generating a nearly Gaussian beam profile with a Strehl ratio above 0.8. As a result, this scheme can be applied to any other focusing optics, thus solving the X-ray optical problem at synchrotron radiation sources and X-ray free-electron lasers.
X-ray imaging is extensively used in medical and materials science. Traditionally, the depth dimension is obtained by turning the sample to gain different views. The famous penetrating properties of X-rays mean that projection views of the subject sample can be readily obtained in the linear absorption regime. 180 degrees of projections can then be combined using computed tomography (CT) methods to obtain a full 3D image, a technique extensively used in medical imaging. In the work now presented in Nature Materials, Stephan Hruszkewycz and colleagues have demonstrated genuine 3D imaging by a new method called 3D Bragg projection ptychography1. Our approach combines the 'side view' capability of using Bragg diffraction from a crystalline sample with the coherence capabilities of ptychography. Thus, it results in a 3D image from a 2D raster scan of a coherent beam across a sample that does not have to be rotated.
Lensless X-ray imaging techniques such as coherent diffraction imaging and ptychography, and Fourier transform holography can provide time-resolved, diffraction-limited images. Nearly all examples of these techniques have focused on transmission geometry, restricting the samples and reciprocal spaces that can be investigated. We report a lensless X-ray technique developed for imaging in Bragg and small-angle scattering geometries, which may also find application in transmission geometries. We demonstrate this by imaging a nanofabricated pseudorandom binary structure in small-angle reflection geometry. The technique can be used with extended objects, places no restriction on sample size, and requires no additional sample masking. The realization of X-ray lensless imaging in reflection geometry opens up the possibility of single-shot imaging of surfaces in thin films, buried interfaces in magnetic multilayers, organic photovoltaic and field-effect transistor devices, or Bragg planes in a single crystal.
Abstract Metal-organic layers (MOLs) are highly attractive for application in catalysis, separation, sensing and biomedicine, owing to their tunable framework structure. However, it is challenging to obtain comprehensive information about the formation and local structures of MOLs using standard electron microscopy methods due to serious damage under electron beam irradiation. Here, we investigate the growth processes and local structures of MOLs utilizing a combination of liquid-phase transmission electron microscopy, cryogenic electron microscopy and electron ptychography. Our results show a multistep formation process, where precursor clusters first form in solution, then they are complexed with ligands to form non-crystalline solids, followed by the arrangement of the cluster-ligand complex into crystalline sheets, with additional possible growth by the addition of clusters to surface edges. Moreover, high-resolution imaging allows us to identify missing clusters, dislocations, loop and flat surface terminations and ligand connectors in the MOLs. Our observations provide insights into controllable MOL crystal morphology, defect engineering, and surface modification, thus assisting novel MOL design and synthesis.