Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Single layer graphene protective layer on GaAs photocathodes for spin-polarized electron source

GaAs-based photocathodes are the primary choice for polarized electron sources, commonly used in polarized electron microscopes and polarized positron sources. GaAs photocathodes are typically activated with cesium and oxygen, which are highly reactive and require an ultra-high vacuum (⁠~ 10 -11 Torr or lower) to operate reliably, resulting in substantial operational difficulties. A short exposure to a mediocre vacuum results in an instantaneous loss of cathode quantum efficiency (QE) due to the chemical reaction of the active layer with residual gas molecules or back-bombardment ions during operation. Covering the GaAs cathode with a 2D material, such as monolayer graphene, could provide protection against such damage due to the inhibition of chemical reactions with residual gas molecules. In this paper, we have incorporated a method known as intercalation to pass the active material underneath the graphene and activate the superlattice GaAs/GaAsP (SL-GaAs) photocathode. X-ray photoelectron spectroscopy, low-energy electron microscopy, and Mott scattering measurements were performed to evaluate the formation of the photocathode under graphene, as well as its spectral response and electron spin polarization. Our results demonstrate that the successful activation of the SL-GaAs photocathode with a graphene protection layer is achieved with a moderate QE. Furthermore, we found that the electron spin polarization of the cathode with a surface protection layer is higher than the conventional cathode without a protection layer.

2D materials↗

Quantitative measure of topological protection in Floquet systems through the spectral localizer

The standard understanding of topological protection from band theory is that a system's topology cannot change without first closing the bulk band gap. However, in Floquet systems, this typical definition of topological protection is one step removed from the experimentally accessible system parameters, as the relationship between the disorder in a system's instantaneous Hamiltonian and its Floquet Hamiltonian that defines its topology is not straightforward. Here, in this study, we demonstrate that the spectral localizer framework for classifying material topology can be applied to Floquet systems using solely the Floquet Hamiltonian and prove that its associated measure of topological protection can be understood in terms of the disorder across the system's instantaneous Hamiltonians. As such, we have derived a quantitative bound on a Floquet system's topological protection in terms of the instantaneous system. Moreover, we show the utility of these bounds in both ordinary and anomalous Floquet Chern insulators.

Wong, Stephan Manua [Sandia National Laboratories ↗

Crystalline-symmetry-protected Majorana modes in coupled quantum dots

We propose a minimalist architecture for achieving various crystalline-symmetry-protected Majorana modes in an array of coupled quantum dots. Our framework is motivated by the recent experimental demonstrations of two-site and three-site artificial Kitaev chains in a similar setup. We find that introducing a π-phase domain wall in the Kitaev chain leads to a pair of mirror-protected Majorana zero modes located at or near the junction. Joining two π junctions into a closed loop, we can simulate two distinct classes of two-dimensional higher-order topological superconducting phases, both carrying symmetry-protected Majorana modes around the sample corners. As an extension of the π junction, we further consider a general vertex structure where n Kitaev chains meet, i.e., a Kitaev n vertex. We prove that such an n vertex, if respecting a dihedral symmetry group D n , necessarily carries n vertex-bound Majorana modes protected by the D n symmetry. Resilience of the junction and vertex Majorana bound states against disorder and correlation effects is also discussed. Our architecture paves the way for designing, constructing, and exploring a wide variety of artificial topological crystalline phases in quantum-dot experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification↗

Cyber-Physical Power Systems Protection: The Byzantine Cybersecurity Framework

Cybersecurity of smart grids have been topic of much interest in recent years. As this critical infrastructure operation increases dependency on automated processes and controls, exposure to cyber-physical threats become inevitable. Considering cyber-physical security of the grid, much focus of attention has been made towards smart grids real-time monitoring solutions, including the state estimation process. Analyzing the relevant literature, one can note though that seldom research has been done on cyber-physical security of smart grids protection systems. Protection systems have intangible value towards grid reliability. This paper presents a cybersecurity framework for smart grids protection systems. A physics-based inspired machine learning solution is at the core process of the framework. Processed relay inputs and outputs are used by a deep predictive coding network. Formal models, a quasi-static state estimator, provides an oracle when low confidence decision is reached. Evolving knowledge is derived through reinforcement learning. Implementation aspects considering the Pacific Northwest National Laboratory Electricity Infrastructure Operations Center are presented. Built as an extra control layer to protection systems, without hard-to-derive parameters, highlights potential aspects towards real-life applications.

Bretas, Arturo Suman↗

Quench Protection Study of Superconducting Magnets for the Materials Plasma Exposure Experiment

To advance the understanding of plasma material interactions, the Material Plasma Exposure eXperiment (MPEX) is a new linear plasma device that will generate and deliver plasma relevant to future fusion reactor divertors. The operation of MPEX is planned to be steady-state in order to facilitate high fluence exposures of plasma facing materials and components. The desire for steady-state operation along with the magnetic field requires the utilization of superconducting coils. The superconducting magnet system for MPEX has been developed. The baseline model has six superconducting magnet and one room-temperature magnet subsystems. In order to protect multiple superconducting magnet systems, quench analysis was carried out to determine the best protection approach for each magnet type. Because the mutual inductance accounts for approximately 35% of the stored energy in the entire system, this must be considered when determining the peak voltages and temperatures during a quench. Two approaches for passive quench protection are considered: (1) self-protecting magnets and (2) use of diodes to sub-divide the coils. For both approaches, active quench detection will be used to ensure all coils are de-energized in the event of a quench. Results of the quench analysis for several quench scenarios are presented.

Burkhardt, Earle↗

Comparison and Discussion on Shortcircuit Protections for Silicon-Carbide MOSFET Modules: Desaturation Versus Rogowski Switch-Current Sensor

Survivability of silicon-carbide (SiC) mosfet modules during short circuit (SC) is essential for modern power electronics systems due to large economic implications. SiC mosfet modules exhibit narrow SC withstand times and generally much lower SC robustness than silicon (Si) insulated-gate bipolar transistors (IGBTs). This puts a critical concern on their utilization, further stressing the importance of reliable protection. This article presents a comprehensive analysis and discussion on the SiC mosfet module SC protection and performance comparison between conventional desaturation detection, previously used for Si IGBT protection, and Rogowski switch-current sensor (RSCS) detection. In addition, this article presents the experimental design for soft turn-off as a reaction to the SC detection to avoid excessive overshoots during the abrupt turn-off of the SC current. To perform different types of SC with various fault inductances on different temperatures, and for the sake of fair comparison under the same conditions, a gate-driver unit for 1.2 kV SiC mosfet half-bridge modules is developed containing both detection methods. The results demonstrate that both methods are successful in protecting the module in all SC types, with superiority of the RSCS detection and concerns for desaturation detection in high-inductance and high dc-bus voltage SC events.

42 ENGINEERING↗

Adaptive Protection of Scientific Backbone Networks Using Machine Learning

In this article, we propose a new protection scheme for backbone networks to guarantee high service availability. The presented scheme does not require any reconfiguration immediately after the failure (i.e., it is proactive). At the same time, it does not require any reserved backup network resources either. To achieve these seemingly contradictory goals, we utilize the recent advancements in Machine Learning (ML) to implement a network intelligence that periodically re-allocates the unused capacity as protection bandwidth to meet the service availability requirements of each connection. Our goal is achieved by two components (1) predicting the traffic for the next period on each link, and (2) intelligently selecting the best fit dedicated protection scheme for the next period depending on the estimated unused (spare) bandwidth and the previous service availability violations. Note that re-allocating protection bandwidth affects neither the operational connections nor the current best practice of operators to over-provision network bandwidth to support elephant flows. Finally, we provide a case study on the real traffic from Energy Sciences Network (ESnet), a high-speed, international scientific backbone network. The key benefit of our framework is that adaptively utilizing the over-provisioned bandwidth for spare capacity is sufficient to improve the availability from three-nines to five-nines (in ESnet for the 30 examined connections). The drawback is negligible bandwidth limitations; the user perceives a minor and very temporal bandwidth limitation in less than 0.1% of the time.

42 ENGINEERING↗

Evaluation of the recombinant proteins RlpB and VacJ as a vaccine for protection against Glaesserella parasuis in pigs

Abstract Background Glaesserella parasuis , the causative agent of Glӓsser’s disease, is widespread in swine globally resulting in significant economic losses to the swine industry. Prevention of Glӓsser’s disease in pigs has been plagued with an inability to design broadly protective vaccines, as many bacterin based platforms generate serovar or strain specific immunity. Subunit vaccines are of interest to provide protective immunity to multiple strains of G. parasuis . Selected proteins for subunit vaccination should be widespread, highly conserved, and surface exposed. Results Two candidate proteins for subunit vaccination (RlpB and VacJ) against G. parasuis were identified using random mutagenesis and an in vitro organ culture system. Pigs were vaccinated with recombinant RlpB and VacJ, outer membrane proteins with important contributions to cellular function and viability. Though high antibody titers to the recombinant proteins and increased interferon-γ producing cells were found in subunit vaccinated animals, the pigs were not protected from developing systemic disease. Conclusions It appears there may be insufficient RlpB and VacJ exposed on the bacterial surface for antibody to bind, preventing high RlpB and VacJ specific antibody titers from protecting animals from G. parasuis . Additionally, this work confirms the importance of utilizing the natural host species when assessing the efficacy of vaccine candidates.

Hau, Samantha J.↗

Impact of Inverter Based Resource Negative Sequence Current Injection on Transmission System Protection

This report documents the results of analysis performed to investigate the impact of inverter-based resource (IBR) response to unbalanced faults on transmission system protective relay dependability and security. Electromagnetic transient (EMT) simulations were performed to simulate IBR response to these faults using existing manufacturer-developed EMT models for four separate IBRs. The study team was composed of IBR manufacturers, relay manufacturers, transmission providers, reliability coordinators and industry consultants with experience in EMT simulation and system protection. The results indicate that under certain conditions, IBR response can result in protective relay misoperations if current protection practices, which were developed based on conventional power sources, are not adapted to the characteristics of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation and optimization for the decontamination/sterilization of personal protective equipment using a novel ozone chamber (CRADA Final Report)

Personal protective equipment slows the spread of the SARS-Cov-2 virus and protects first responders and the general population. However, there is a significant and well-publicized shortage of personal protective equipment for healthcare workers. Treatment with ozone may be a compelling, affordable, and scalable method to rapidly decontaminate personal protective equipment but more work is needed to verify these claims. Together with colleagues at the University of Nevada Reno and FATHHOME we helped design the experiments that evaluated the virucidal efficacy of FATHHOME’s device on N95 face masks and face shields. The results of our study were published in the journal Pathogens.

60 APPLIED LIFE SCIENCES↗

Electron Ion Collider Machine Protection System: On the necessity of the MPS abort system for Rapid Cycling Synchrotron

The Electron Ion Collider (EIC) accelerator complex includes multiple high-energy high-power accelerators [1]. Operation of such a complex is associated with numerous dangers of possible damage to the equipment. The EIC machine protection system (MPS) scope is to protect the components of each accelerator from damage by the beam. The EIC MPS design, commissioning and operation is closely interconnected with the protection of various accelerator subsystems, such as RF-system, cryogenics, vacuum system etc. Yet, the primary goal of the MPS is to protect the EIC accelerators from the possible damage caused by electron and proton beams.

43 PARTICLE ACCELERATORS↗

Electron Ion Collider Machine Protection System: Requirements for an Electron Storage Ring abort system

The Electron Ion Collider (EIC) accelerator complex includes multiple high-energy high-power accelerators [1]. Operation of such a complex is associated with numerous hazards and risks of possible damage to the equipment. The EIC machine protection system (MPS) scope is to protect the components of each accelerator from damage by the beam. The EIC MPS design, commissioning and operation is closely interconnected with the protection of various accelerator subsystems, such as RF-system, cryogenics, vacuum system etc. Yet, the primary goal of the MPS is to protect the EIC accelerators from the possible damage caused by electron and proton beams.

43 PARTICLE ACCELERATORS↗

2022 Peer Review Project Summary: Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (mediumvoltage) level may also become common as a means for improving distribution reliability and resilience. The objective of this multiyear project is to increase the adoption of microgrids in secondary networks and meshed distribution systems by developing novel protection schemes that allow for safe reliable operation of DERs in secondary networks. We will address these challenges by working with the appropriate stakeholders of secondary network operators, protection vendors, and standards committee. The outcomes of this project include: a) development and/or demonstration of candidate methods for enabling protection of secondary networks containing high levels of DER; b) development of modeling and testing tools for protection systems designed for use with secondary networks including DERs; and c) development of new industrial partnerships to facilitate widespread results dissemination and eventual commercialization of results as appropriate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Protection and Control for High Penetration PV and Grid Resilience (Final Technical Report)

The report summarizes the work and accomplishments of DOE SETO funded project 36533 “Adaptive Protection and Control for High Penetration PV and Grid Resilience”. In order to increase the amount of distributed solar power that can be integrated into the distribution system, new methods for optimal adaptive protection, artificial intelligence or machine learning based protection, and time domain traveling wave protection are developed and demonstrated in hardware-in-the-loop and a field demonstration.

14 SOLAR ENERGY↗

Technical Learning and Integration of Interns in Advanced Protection Lab Space: Enhancements to Testbed and Experiments to Improve Workflows for Producing Datasets

This report presents a successful technical learning integration of student interns in the Advanced Protection Laboratory space, located in the Grid Research Integration and Deployment Center (GRID-C) at the Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL). The Advanced Protection Laboratory was created for the primary goal of supporting DOE’s research projects and technical staff at ORNL. As a secondary goal, the space was used for collaborating with ORNL’s intern programs, providing support to the lab’s mentors and student interns. In 2024, three student interns spent a summer in the Advanced Protection lab space and were involved in the DarkNet Distributed Ledger Technology (DLT) project. The students had a great opportunity to gain hands-on experience with communication and protective relay equipment focused on information technology, data analytics, and cybersecurity. Experiences in the lab space with real equipment and software integration offer education and professional development for students, which is especially important because of a need in the energy industry to recruit highly skilled power and communication engineers.

42 ENGINEERING↗

Synchrophasor-Based Zonal Current Differential Protection for Secondary Low Voltage Networks

This report describes an approach to utilizing phasor measurement unit (PMU) data from multiple Intelligent Electronics Devices (IEDs) in a low-voltage network to produce a differential scheme for protecting the medium-voltage feeder and low-voltage network transformers. The proposed protection scheme is designed and prototyped on a real-time automation controller. Its performance is evaluated using real-time controller hardware-in-the-loop simulation. Lab testing results indicate that the proposed protection scheme allows significant distributed energy resources (DER) backfeed and enables selective and fast protection of medium voltage feeders.

42 ENGINEERING↗

Leveraging PMU for Protection and Control

This presentation discusses the application of synchronized measurement in transmission system protection. The proposed wide area system protection (WASP) scheme uses PMU data to perform zonal current differential protection for the whole transmission system with high IBR penetration. This novel protection concept uses synchronized measurement, which is one of the key tasks proposed in the award DE-EE0010655.

14 SOLAR ENERGY↗