SSR1 Cryomodule Design for PXIE

Fermilab is in the process of designing a Project X Injector Experiment (PXIE), a CW linac, to validate the Project X concept, reduce technical risks, and obtain experience in the design and operation of a superconducting proton linac. The over-all facility will include an ion source, low and medium-energy beam transport sec-tions, an RF quadrupole, and two superconducting cavity cryomodules. One will contain eight half-wave resonators operating at 162.5 MHz and eight superconduct-ing solenoids. The second will contain eight single spoke resonators (SSR1) oper-ating at 325 MHz and four superconducting solenoids. The design of the cryomod-ule being developed to house the 325 MHz single spoke resonators and all related systems and services is described here....

43 PARTICLE ACCELERATORS↗

Taking the MPI standard and the open MPI library to exascale

The Open MPI for Exascale (OMPI-X) project was one of two in the Exascale Computing Project (ECP) focused on advancing the MPI ecosystem. The OMPI-X team worked with other MPI Forum members to champion several important features for inclusion in the MPI 4.0, 4.1, and upcoming 5.0 MPI standard versions, in support of the needs of exascale applications and systems. The team also worked with the larger Open MPI community to bring implementations of these new features and other enhancements into Open MPI, one of the leading open-source implementations of the MPI interface. Here, this paper describes the motivation for the work of the OMPI-X project in the context of exascale computing needs, the nature of the resulting new capabilities in the MPI standard, and how they were implemented in the Open MPI library. Features include improved support for “MPI + X” programming models through partitioned communications and support for user-level threading, sessions, fault tolerance through the user-level fault mitigation (ULFM) and Reinit models, and other features. We also discuss enhancements to Open MPI providing improved performance and scalability for existing features, such as collective operations, one-sided operations, support for the Slingshot-11 interconnect of the initial exascale systems, and how the OMPI-X team worked to improve quality assurance for the Open MPI library, particularly on platforms of interest to the Department of Energy community.

97 MATHEMATICS AND COMPUTING↗

Status of the Short-Pulse X-ray Project at the Advanced Photon Source

The Advanced Photon Source Upgrade (APS-U) Project at Argonne will include generation of short-pulse x-rays based on Zholents deflecting cavity scheme. We have chosen superconducting (SC) cavities in order to have a continuous train of crabbed bunches and flexibility of operating modes. In collaboration with Jefferson Laboratory, we are prototyping and testing a number of single-cell deflecting cavities and associated auxiliary systems with promising initial results. In collaboration with Lawrence Berkeley National Laboratory, we are working to develop state-of-the-art timing, synchronization, and differential rf phase stability systems that are required for SPX. Collaboration with Advanced Computations Department at Stanford Linear Accelerator Center is looking into simulations of complex, multi-cavity geometries with lower- and higher-order modes waveguide dampers using ACE3P. This contribution provides the current R&D status of the SPX project.

43 PARTICLE ACCELERATORS↗

Status of the Short-Pulse X-ray Project (SPX) at the Advanced Photon Source (APS)

The Advanced Photon Source Upgrade project (APS-U) at Argonne includes implementation of Zholents’* deflecting cavity scheme for production of short x-ray pulses. This is a joint project between Argonne National Laboratory, Thomas Jefferson National Laboratory, and Lawrence Berkeley National Laboratory. This paper describes performance characteristics of the proposed source and technical issues related to its realization. Ensuring stable APS storage ring operation requires reducing quality factors of these modes by many orders of magnitude. These challenges reduce to those of the design of a single-cell SC cavity that can achieve the desired operating deflecting fields while providing needed damping of all these modes. The project team is currently prototyping and testing several promising designs for single-cell cavities with the goal of deciding on a winning design in the near future. Here

43 PARTICLE ACCELERATORS↗

SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

60 APPLIED LIFE SCIENCES↗

Design and Analysis of the PXIE CW Radio-frequency Quadrupole (RFQ)

The Project X Injector Experiment (PXIE) will be a prototype front end of the Project X accelerator proposed by Fermilab. PXIE will consist of an H- ion source, a low-energy beam transport (LEBT), a radio-frequency quadrupole (RFQ) accelerator , a medium-energy beam transport (MEBT) and a section of superconducting cryomodules that will accelerate the beam from 30 keV to 30 MeV. LBNL has developed an RFQ design for PXIE with fabrication scheduled to begin before the end of CY 2012. The chosen b aseline design is a four-vane, 4.4 m long CW RFQ with a resonant frequency at 162.5 MHz (2.4 wavelengths long). The RFQ will provide bunching and acceleration of a nominal 5 mA H- beam to 2.1 MeV. The relatively low wall power density results in wall powe r losses that are less than 100 kW. The beam dynamics design has been optimized to allow for more than 99% beam capture with exceptionally low longitudinal emittance. The RFQ mechanical design and the results of RF and thermal analyses are presented here.

43 PARTICLE ACCELERATORS↗

SSR1 Cryomodule Design PXIE

Fermilab is planning to design and build a Project X Injector Experiment (PXIE), a cw linac, as a means of validating the Project X concept, reducing technical risks, and obtaining experience in the design and operation of a superconducting pr oton linac. The overall facility will include an ion source, low and medium-energy beam transport sections, a radio frequency quadrupole, and two cryomodules containing superconducting cavities. One will contain nine half-wave resonators operating at 162. 5 MHz and six superconducting solenoids. The second will contain eight single spoke resonators (SSR1) operating at 325 MHz and four superconducting solenoids. This paper describes the design of the cryomodule being developed to house the 325 MHz single sp oke resonators. Each of the main cryomodule systems will be described; cryogenic systems and instrumentation, cavity and solenoid positioning and alignment, conduction-cooled current leads, RF input couplers, magnetic shielding, cold-to-warm beam tube tra nsitions, interfaces to interconnecting equipment and adjacent modules, as well as the overall assembly procedure.

43 PARTICLE ACCELERATORS↗

High-power Waveguide Dampers for the Short-Pulse X-Ray Project at the Advanced Photon Source

High-power waveguide dampers have been designed and prototyped for the Short-Pulse X-ray (SPX) cavities at the Advanced Photon Source. The cavities will operate at 2.815 GHz and utilize the TM110 dipole mode. As a result, higher-order (HOM) and lower-order mode (LOM) in-vacuum dampers have been designed to satisfy the demanding broadband damping requirements in the APS storage ring. The SPX single-cell cavity consists of two WR284 waveguides for damping the HOMs and one WR284 waveguide for primarily damping the LOM where up to 2kW will be dissipated in the damping material. The damper designs and high-power experimental results will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Parametric Reconstruction of Glass Fiber-reinforced Polymer Composites from X-ray Projection Data—A Simulation Study

We present a new approach to estimate geometry parameters of glass fibers in glass fiber-reinforced polymers from simulated X-ray micro-computed tomography scans. Traditionally, these parameters are estimated using a multi-step procedure including image reconstruction, pre-processing, segmentation and analysis of features of interest. Each step in this chain introduces errors that propagate through the pipeline and impair the accuracy of the estimated parameters. In the approach presented in this paper, we reconstruct volumes from a low number of projection angles using an iterative reconstruction technique and then estimate position, direction and length of the contained fibers incorporating a priori knowledge about their shape, modeled as a geometric representation, which is then optimized. Using simulation experiments, we show that our method can estimate those representations even in presence of noisy data and only very few projection angles available.

42 ENGINEERING↗

Engineering design of vertical test stand cryostat

Under Indian Institutions and Fermilab collaboration, Raja Ramanna Centre for Advanced Technology and Fermi National Accelerator Laboratory are jointly developing 2K Vertical Test Stand (VTS) cryostats for testing SCRF cavities at 2K. The VTS cryostat has been designed for a large testing aperture of 86.36 cm for testing of 325 MHz Spoke resonators, 650 MHz and 1.3 GHz multi-cell SCRF cavities for Fermilab's Project-X. Units will be installed at Fermilab and RRCAT and used to test cavities for Project-X. A VTS cryostat comprises of liquid helium (LHe) vessel with internal magnetic shield, top insert plate equipped with cavity support stand and radiation shield, liquid nitrogen (LN{sub 2}) shield and vacuum vessel with external magnetic shield. The engineering design and analysis of VTS cryostat has been carried out using ASME B&PV Code and Finite Element Analysis. Design of internal and external magnetic shields was performed to limit the magnetic field inside LHe vessel at the cavity surface <1 {micro}T. Thermal analysis for LN{sub 2} shield has been performed to check the effectiveness of LN{sub 2} cooling and for compliance with ASME piping code allowable stresses.

43 PARTICLE ACCELERATORS↗

Neutrino SuperBeams at Fermilab

In this talk I will give a brief description of long baseline neutrino physics, the LBNE experiment and Project X at Fermilab. A brief outline of the physics of long baseline neutrino experiments, LBNE and Project X at Fermilab is given in this talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Impact of Intrinsic Heavy Quark Distributions in the Proton on New Physics Searches at the High Intensity Frontier

The possibility of an intense proton facility, at 'Project X' or elsewhere, will provide many new opportunities for searches for physics beyond the Standard Model. A Project X can serve a yet broader role in the search for new physics, and in this note we highlight the manner in which thus-enabled studies of the flavor structure of the proton, particularly of its intrinsic heavy quark content, facilitate other direct and indirect searches for new physics. Intrinsic heavy quarks in both light and heavy hadrons play a key role in searches for physics BSM with hadrons - and their study at the Intensity Frontier may prove crucial to establishing its existence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of effects of failure of beamline elements and their compensation in CW superconducting linac

Project-X is the proposed high intensity proton facility to be built at Fermilab, US. First stage of the Project-X consists of superconducting linac which will be operated in continuous wave (CW) mode to accelerate the beam from 2.5 MeV to 3 GeV. The operation at CW mode puts high tolerances on the beam line components, particularly on radiofrequency (RF) cavity. The failure of beam line elements at low energy is very critical as it results in mis-match of the beam with the following sections due to different beam parameters than designed parameter. It makes the beam unstable which causes emittance dilution, and ultimately results in beam losses. In worst case, it could affect the reliability of the machine and may lead to the shutdown of the Linac to replace the failed elements. Thus, it is important to study these effects and their compensation to get smooth beam propagation in linac. This paper describes the results of study performed for the failure of RF cavity & solenoid in SSR0 section.

43 PARTICLE ACCELERATORS↗

Superconducting radiofrequency linac development at Fermilab

As the Fermilab Tevatron Collider program draws to a close, a strategy has emerged of an experimental program built around the high intensity frontier. The centerpiece of this program is a superconducting H- linac that will support world leading programs in long baseline neutrino experimentation and the study of rare processes. Based on technology shared with the International Linear Collider, Project X will provide multi-MW beams at 60-120 GeV from the Main Injector, simultaneous with very high intensity beams at lower energies. Project X also supports development of a Muon Collider as a future facility at the energy frontier.

43 PARTICLE ACCELERATORS↗

Simulations of space charge in the Fermilab Main Injector

The Fermilab Project X plan for future high intensity operation relies on the Main Injector as the engine for delivering protons in the 60-120 GeV energy range. Project X plans call for increasing the number of protons per Main Injector bunch from the current value of 1.0 x 10{sup 11} to 3.0 x 10{sup 11}. Space charge effects at the injection energy of 8 GeV have the potential to seriously disrupt operations. We report on ongoing simulation efforts with Synergia, MARYLIE/Impact, and IMPACT, which provide comprehensive capabilities for parallel, multi-physics modeling of beam dynamics in the Main Injector including 3D space-charge effects.

43 PARTICLE ACCELERATORS↗

The High Intensity Horizon at Fermilab

Fermilab's high intensity horizon is 'Project-X' which is a US led initiative with strong international participation that aims to realize a next generation proton source that will dramatically extend the reach of Intensity Frontier research. The Project-X research program includes world leading sensitivity in long-baseline and short-baseline neutrino experiments, a rich program of ultra-rare muon and kaon decays, opportunities for next-generation electric dipole moment experiments and other nuclear/particle physics probes, and a platform to investigate technologies for next generation energy applications. A wide range of R&D activities has supported mission critical accelerator subsystems, such as high-gradient superconducting RF accelerating structures, efficient RF power systems, cryo-modules and cryogenic refrigeration plants, advanced beam diagnostics and instrumentation, high-power targetry, as well as the related infrastructure and civil construction preparing for a construction start of a staged program as early as 2017.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secondary Electron Yield Measurements of Fermilab?s Main Injector Vacuum Vessel

We discuss the progress made on a new installation in Fermilab's Main Injector that will help investigate the electron cloud phenomenon by making direct measurements of the secondary electron yield (SEY) of samples irradiated in the accelerator. In the Project X upgrade the Main Injector will have its beam intensity increased by a factor of three compared to current operations. This may result in the beam being subject to instabilities from the electron cloud. Measured SEY values can be used to further constrain simulations and aid our extrapolation to Project X intensities. The SEY test-stand, developed in conjunction with Cornell and SLAC, is capable of measuring the SEY from samples using an incident electron beam when the samples are biased at different voltages. We present the design and manufacture of the test-stand and the results of initial laboratory tests on samples prior to installation.

43 PARTICLE ACCELERATORS↗

Progress with PXIE MEBT Chopper

A capability to provide a large variety of bunch patterns is crucial for the concept of the Project X serving MW-range beam to several experiments simultaneously. This capability will be realized by the Medium Energy Beam Transport's (MEBT) chopping system that will divert 80% of all bunches of the initially 5 mA, 2.1 MeV CW 162.5 MHz beam to an absorber according to a pre-programmed bunch-by-bunch selection. Being considered one of the most challenging components, the chopping system will be tested at the Project X Injector Experiment (PXIE) facility that will be built at Fermilab as a prototype of the Pojrect X front end. The bunch deflection will be made by two identical sets of travelling-wave kickers working in sync. Presently, two versions of the kickers are being investigated: a helical 200 Ohm structure with a switching-type 500 V driver and a planar 50 Ohm structure with a linear {+-} 250 V amplifier. This paper describes the chopping system scheme and functional specifications for the kickers, present results of electromagnetic measurements of the models, discuss possible driver schemes, and show a conceptual mechanical design.