Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

An improved static probe design

A new static probe design is described in which the static holes are located much closer to the tip than in conventional probes. The new probe shows promise for use in some situations where conventional probes become highly inaccurate. An additional advantage of the new design is that, when used in static pressure survey rakes, the probes can be located much closer together than in conventional designs and still ensure that disturbances from neighboring probe tips do not affect the static readings.

Pinckney, S. Z.

Jupiter probe heatshield configuration optimization

The effect of initial probe heatshield shape on the total probe mass loss during Jovian entry is considered. Modification of the aerothermal environment and probe entry trajectory due to changing probe heatshield shape is included in a computerized technique designed for rapid assessment of the effect of probe initial shape on heatshield mass loss. Results obtained indicate the importance of trajectory and heating distribution coupling with probe shape and mass change.

Dirling, R. B., Jr.

Magnetosheath effects on cylindrical Langmuir probes

A study of the response of cylindrical Langmuir probes in magnetoplasmas focusing on the relative magnitudes of Larmor radius and sheath size is presented. The approach results in a classification of magnetic field effects which involves the magnetic field strength and plasma parameters of density, temperature, and the applied probe potential. It is shown that a 0.25 G field can have similar effects on the current collection properties of the probe in ionospheric plasma as a 30 kG field would have in a hot, dense laboratory plasma. The data also show: (1) the effects of probe orientation on electron current collection from magnetoplasmas; (2) that these effects can be important even when the electron Larmor radius is larger than the radius of the probe; and (3) that substantial magnetic field effects occur when the probe sheath is comparable to or greater than the Larmor radius.

Szuszczewicz, E. P.

An entry and landing probe for Titan

Results of a recent study of entry and landing probes for the exploration of Titan are presented. The probes considered were based on a wide range of exploration mission possibilities. They included: an atmospheric science probe; an intermediate, atmospheric and limited surface science probe; and a larger atmospheric and expanded surface science probe. Because of lower gravity on Titan and its atmosphere characteristics, the entry environment is less severe than that of Mars. However, the large uncertainties in the current definition of the atmosphere and uncertainties in Titan's surface characteristics have required trade-offs of various combinations of entry and descent shapes and hard lander configurations. Results show that all probe classes are feasible without major developments.

Murphy, J. P.

Conventional probes for the relative flow measurement in a rotor blade passage

This paper reports the measurement of the relative flow in the rotor blade passages of an axial flow compressor and an axial flow inducer using conventional probes such as five-hole, disc and the spherical pitot-static probes. The probe provides an inexpensive, yet accurate, method of deriving the three dimensional flow field in a rotor. The disc probe is suitable for the blade boundary layer measurement and the pitot-static probe for the static and stagnation pressures and the total velocity across the rotor passage. Typical data obtained from each of these probes demonstrate the complex nature of turbomachinery rotor flow.

Sitaram, N.

Eddy current probe response to open and closed surface flaws

A general analysis of eddy current response to certain types of open and closed surface flaws is presented for both standard low-frequency and ferromagnetic-resonance (FMR) probes. It is shown analytically that for two-dimensional and three-dimensional surface flaws interrogated by a uniform probe field, the crack opening sensitivity increases with the operating frequency of the probe, this behavior being due to the Faraday induction effect. Experiments with low-frequency probes operating at or below 1 MHz and with the FMR probe operating at approximately 1000 MHz confirm this increase of the crack mouth opening displacement for practical situations where the probe field is not uniform in the vicinity of the flaw.

Auld, B. A.

System and method for moving a probe to follow movements of tissue

An apparatus is described for moving a probe that engages moving living tissue such as a heart or an artery that is penetrated by the probe, which moves the probe in synchronism with the tissue to maintain the probe at a constant location with respect to the tissue. The apparatus includes a servo positioner which moves a servo member to maintain a constant distance from a sensed object while applying very little force to the sensed object, and a follower having a stirrup at one end resting on a surface of the living tissue and another end carrying a sensed object adjacent to the servo member. A probe holder has one end mounted on the servo member and another end which holds the probe.

Feldstein, C.

Galileo atmospheric entry probe mission description

The mission goals, control parameters, and instrumentation for the Galileo entry probe are described. The goal for the probe is to penetrate the Jovian atmosphere to 10 bars, begin data gathering and transmission at about 0.1 bar, and make as many in-situ cloud measurements as possible. The probe will pass through a 16,000 K shock layer, which has led to a ratio of 5 kg of heat shield to every kg of instrumentation on the probe. An entry angle between -7.0 to -10.2 deg will be used, and possible targets with respect to declinations associated with a 1986 launch are discussed. The preentry mission phase, entry/descent sequence, and the baseline mission relay link performance are outlined. Data may be available down to 20 bars, and the probe performance will aid in design goals for subsequent Saturn and Uranus probes.

Vojvodich, N. S.

Electron temperature measurements using a 12-channel array probe

The most common technique for determining the mean kinetic energy of electrons in low-temperature plasmas utilizes the so-called Langmuir probe. The present investigation is concerned with the study of the electron temperature in a pulsed high-beta plasma as a function of time by means of a miniature array of 12 planar Langmuir probes. By using a probe with many individually collecting surfaces, each biased at a different fixed voltage, an approximation to the true probe characteristic is obtained when monitoring the collected currents for each independent subprobe. The employed method, by using many points, provides enough information to reconstruct the entire I-V curve. Attention is given to the principle of operation of the new probe, calibration, accuracy, time resolution, and applications of the new method. By employing two probes it is possible to perform correlation measurements to study heat flow and temperature fluctuations.

Wild, N.

Combination probe for hi-frequency unsteady aerodynamic measurements

A combination probe for time-resolved measurements of unsteady compressible flows in transonic wind tunnels is described. The probe measures stagnation (total) temperature and pressure, static pressure, and flow angles in two planes. From these, the fluctuating mass flux, Mach number, and velocity as well as their components in three directions can be deduced. The combination probe consists of a dual hot-wire aspirating temperature and pressure probe mounted piggyback with a high-frequency angle probe. The angle probe has four surface-mounted silicon pressure sensors. A scheme is described for retrieving from the four pressure signals the stagnation and static pressures, Mach number, and flow angles in two planes. The calibrations forming the base for this procedure, obtained from steady-state tests, are given. Typical data obtained in the Karman vortex street shed from a cylinder and at the exit of a Mach 0.4 air jet are presented.

Ng, W. F.

A combination probe for high-frequency unsteady aerodynamic measurements in transonic wind tunnels

A combination probe for time-resolved measurements for unsteady compressible flows is described. The probe measures stagnation (total) temperature and pressure, static pressure, and flow angles in two planes. From these, the fluctuating mass flux, Mach number, and velocity as well as their components in three directions can be deduced. The combination probe consists of a dual hot-wire aspirating temperature and pressure probe mounted piggyback with a high-frequency angle probe. The angle probe has four surface-mounted silicon pressure sensors. A scheme is described for retrieving from the four pressure signals the stagnation and static pressures, Mach number, and flow angles in two planes. The calibrations forming the basis for this procedure, obtained from steady-state tests, are given. Typical data obtained in the Karman vortex street shed from a cylinder and at the exit of a Mach-0.4 air jet are presented.

Ng, Wing F.

Double-probe potential measurements near the Spacelab 2 electron beam

As part of the Spacelab 2 mission the plasma diagnostics package (PDP) was released from the shuttle as a free-flying satellite. The PDP carried a quasi-static electric field instrument which made differential voltage measurements between two floating probes. At various times during the free flight, an electron beam was ejected from the shuttle. Large differential voltages between the double probes were recorded in association with the electron beam. However, analysis indicates that these large signals are probably not caused by ambient electric fields. Instead, they can be explained by considering three effects: shadowing of the probes from streaming electrons by the PDP chassis, crossing of the PDP wake by the probes, and spatial gradients in the fluxes of energetic electrons reaching the probes. Plasma measurements on the PDP show that energetic electrons exist in a region 20 m wide and up to at least 170 m downstream from the electron beam. At 80 or more meters downstream from the beam, the double probe measurements show that the energetic electron flux is opposite to the injection direction, as would be expected for a secondary returning electron beam produced by scattering of the primary electron beam.

Steinberg, J. T.

Stripline feed for a microstrip array of patch elements with teardrop shaped probes

A circularly polarized microstrip array antenna utilizing a honeycomb substrate made of dielectric material to support on one side the microstrip patch elements in an array, and on the other side a stripline circuit for feeding the patch elements in subarray groups of four with angular orientation and phase for producing circularly polarized radiation, preferably at a 0, 90, 180, and 270 degree relationship is described. The probe used for coupling each feed point in the stripline circuit to a microstrip patch element is teardrop shaped in order to introduce capacitance between the coupling probe and the metal sheet of the stripline circuit that serves as an antenna ground plane. The capacitance thus introduced tunes out inductance of the probe. The shape of the teardrop probe is not critical. The probe capacitance required is controlled by the maximum diameter for the teardrop shaped probe, which can be empirically determined for the operating frequency. An aluminum baffle around each subarray blocks out surface wave between subarrays.

Huang, John

Design of fiber optic probes for laser light scattering

A quantitative analysis is presented of the role of optical fibers in laser light scattering. Design of a general fiber optic/microlens probe by means of ray tracing is described. Several different geometries employing an optical fiber of the type used in lightwave communications and a graded index microlens are considered. Experimental results using a nonimaging fiber optic detector probe show that due to geometrical limitations of single mode fibers, a probe using a multimode optical fiber has better performance, for both static and dynamic measurements of the scattered light intensity, compared with a probe using a single mode fiber. Fiber optic detector probes are shown to be more efficient at data collection when compared with conventional approaches to measurements of the scattered laser light. Integration of fiber optic detector probes into a fiber optic spectrometer offers considerable miniaturization of conventional light scattering spectrometers, which can be made arbitrarily small. In addition static and dynamic measurements of scattered light can be made within the scattering cell and consequently very close to the scattering center.

Dhadwal, Harbans S.

Gravitational experiments on a solar probe mission: Scientific objectives and technology considerations

The concept of a solar impact probe (either solar plunger or sun grazer) led to the initiation of a NASA study at JPL in 1978 on the engineering and scientific feasibility of a Solar Probe Mission, named Starprobe, in which a spacecraft is placed in a high eccentricity orbit with a perihelion near 4 solar radii. The Starprobe study showed that the concept was feasible and in fact preliminary mission and spacecraft designs were developed. In the early stages of the Solar Probe studies the emphasis was placed on gravitational science, but by the time of a workshop at Caltech in May 1978 (Neugebauer and Davies, 1978) there was about an equal division of interest between heliospheric physics and gravitation. The last of the gravitational studies for Solar Probe was conducted at JPL in 1983. Since that time, the Committee on Solar and Space Physics (CSSP) of the National Academy of Sciences has recommended the pursuit of a focused mission, featuring fields and particles instrumentation and emphasizing studies of the solar wind source region. Such a solar probe mission is currently listed as the 1994 Major New Star candidate. In the remainder of this review, the unique gravitational science that can be accomplished with a solar probe mission is reviewed. In addition the technology issues that were identified in 1980 by the ad hoc working group for Gravity and Relativity Science are addressed.

Anderson, John D.

Thrust Vector Control using movable probes

A study was undertaken to determine if movable probes or struts positioned in the nozzle can be used to provide Thrust Vector Control of the Space Shuttle Solid Rocket Booster. The study employed CFD to determine estimates of the shock standoff distance from the probe. An empirical correlation was used to construct the shock shape and the pressure distribution generated by the probe. The TVC performance for a single and multiple number of probes was then used to determine requirements for a maximum thrust angle offset of 7.5 degrees. Consideration was given to what materials would be suitable for the probe and if active cooling is required. Based on the performance analysis and thermal requirements, a Probe Thrust Vector Control (PTVC) system was sized. Indications are that a PTVC system weight is in the 1500 1bm weight range, compared to the existing weight of 7500 1bm for the SRB nozzle gimble system.

Cavalleri, Robert

Nucleic acid probes in diagnostic medicine

The need for improved diagnostic procedures is outlined and variations in probe technology are briefly reviewed. A discussion of the application of probe technology to the diagnosis of disease in animals and humans is presented. A comparison of probe versus nonprobe diagnostics and isotopic versus nonisotopic probes is made and the current state of sequence amplification is described. The current market status of nucleic acid probes is reviewed with respect to their diagnostic application in human and veterinary medicine. Representative product examples are described and information on probes being developed that offer promise as future products is discussed.

Oberry, Phillip A.

Performance of the Phase Doppler Particle Analyzer icing cloud droplet sizing probe in the NASA Lewis Icing Research Tunnel

The design, development, and testing of an icing cloud droplet sizing probe based upon the Phase Doppler Particle Analyzer (PDPA) are discussed. This probe is an in-situ laser interferometry based single particle measuring device capable of determining size distributions. The probe is designed for use in harsh environments such as icing tunnels and natural icing clouds. From the measured size distribution, Median Volume Diameter (MVD) and Liquid Water Content (LWC) may be determined. Both the theory of measurement and the mechanical aspects of the probe design and development are discussed. The MVD results from the probe are compared to an existing calibration based upon different instruments in a series of tests in the NASA Lewis Icing Research Tunnel. Agreement between the PDPA probe and the existing calibration is close for MVDs between 15 to 30 microns, but the PDPA results are considerably smaller for MVDs under 15 microns.

Rudoff, R. C.