Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Generation Cycle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

NETL Natural Gas Lifecycle Model

This is the excel-based life cycle model that contains all the parameters and Monte Carlo simulation capabilities to model the techno-regions contained in the report: Life Cycle Analysis of Natural Gas Extraction and Power Generation: U.S. 2020 Emissions Profile.

conventional gas↗

Distributed power generation via gasification of biomass and municipal solid waste: A review

The access to electricity has increased worldwide, growing from 60 million additional consumers per year in 2000-2012 to 100 million per year in 2012-2016. Despite this growth, approximately 675 million people will still lack access to electricity in 2030, indicating that electricity demand will continue to increase. Unfortunately, traditional large fossil power technologies based on coal, oil and natural gas lead to a major concern in tackling worldwide carbon dioxide emissions, and nuclear power remains unpopular due to public safety concerns. Distributed power generation utilizing CO 2 -neutral sources, such as gasification of biomass and municipal solid wastes (MSW), can play an important role in meeting the world energy demand in a sustainable way. Furthermore, this review focuses on the recent technology developments on seven power generation technologies (i.e. internal combustion engine, gas turbine, micro gas turbine, steam turbine, Stirling engine, organic rankine cycle generator, and fuel cell) suitable for distributed power applications with capability of independent operation using syngas derived from gasification of biomass and MSW. Technology selection guidelines is discussed based on criteria, including hardware modification required, size inflexibility, sensitivity to syngas contaminants, operational uncertainty, efficiency, lifetime, fast ramp up/down capability, controls and capital cost. Major challenges facing further development and commercialization of these power generation technologies are discussed.

09 BIOMASS FUELS↗

Voltage-programed control of turboalternator load

A power source and load-control concept was designed and tested for use with a Brayton cycle turboalternator. The concept provides power that adjusts to a range of loads while controlling alternator speed and isolating load-switching transients. The concept is also applicable to power-generating sources other than the Brayton cycle.

Young, R. N.↗

Improving NO x Entitlement with Axial Staging

Manufacturers are constantly under pressure to increase the efficiency of air breathing gas turbines for the next generation of ground based combined cycle power plants without a significant increase in NO x emissions. Axially staging some of the fuel and air is one method manufacturers are exploring to increase the firing temperature with a minimal NO x increase. This project used a high-pressure combustion facility to systematically explore the axial stage design space at conditions relevant to engine manufacturers. Chemiluminescence and PIV images of the reacting jets were obtained as well as exit emissions. This data was used to create correlations for reacting jets-in-crossflow, analogous to what currently exists for non-reacting jets-in-crossflow. Two CFD programs were used to model these results to quantifying the accuracy of the codes and help elucidate the underlying physics that governs the high-pressure reacting jet in crossflow. This report indicates a change in flame/flow-field behavior, and emissions characteristics with increasing pressure from 1-5.5 atm. Additionally, the effects of preheating and premixing the axial jet are explored at various conditions and show increased jet liftoff leads to a decrease in NO x emissions.

03 NATURAL GAS↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications Research Performance Progress Report (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary.

14 SOLAR ENERGY↗

A Review of Tribomaterial Technology for Space Nuclear Power Systems

The National Aeronautics and Space Administration (NASA) has recently proposed a nuclear closed-cycle electric power conversion system for generation of 100-kW of electrical power for space exploration missions. A critical issue is the tribological performance of sliding components within the power conversion unit that will be exposed to neutron radiation. This paper presents a review of the main considerations that have been made in the selection of solid lubricants for similar applications in the past as well as a recommendations for continuing development of the technology.

Stanford, Malcolm K.↗

Computational and Experimental Investigation of Discrete “W” Turbulators for sCO2 Turbine Internal Cooling

Direct-fired supercritical CO2 (sCO2 ) cycles are of particular interest for power generation due to the potential for higher thermal efficiencies with inherent CO2 capture. Direct fired sCO2 turbines must withstand high temperatures and the density of the working fluid is much higher than conventional Brayton cycles. Based on conventional Brayton cycle applications, internal serpentine cooling channels with ribbed turbulator strips are a common approach to achieve the required cooling, while minimizing coolant utilization. Most of the previous studies of coolant channel heat transfer enhancements have focused on serpentine channels using air as the cooling media at Reynold’s numbers typical of Brayton cycles. This paper investigates the Nusselt number augmentation of coolant channels with no features, ribbed turbulators, and discrete “W” turbulators with surface roughness effects included and CO2 as the coolant. The numerical results are compared to experimental results using CO2 as the cooling media at Reynold’s numbers ranging from 100,000 to 300,000. The results show the Nusselt number augmentation plateaus with increasing Reynolds number, in contrast to the decay observed in prior publications with air as the coolant media. Additionally, the CFD results indicate the discrete “W” geometry provides a 10% increase in Nusselt number augmentation relative to the angled ribbed turbulators.

computational fluid dynamics (CFD)↗

Thermodynamic analysis and optimization of supercritical carbon dioxide Brayton cycles for use with low-grade geothermal heat sources

The transcritical carbon dioxide Rankine cycle has emerged as an alternative for power generation in low-grade heat applications. However, the low heat rejection temperatures required for condensing the carbon dioxide is almost prohibitive for many locations. A simple solution is the adoption of a supercritical carbon dioxide Brayton cycle which does not need such low temperature heat sinks. This power cycle has been poorly studied previously in low-grade heat applications. Therefore, with the aim of determining the performance and feasibility of the supercritical carbon dioxide Brayton cycle from thermodynamic viewpoint, using a low-grade geothermal heat source, this paper presents a comparative thermodynamic analysis between four different supercritical carbon dioxide Brayton cycles. For this purpose, detailed models were developed and solved by coupling the thermodynamic model with the thermal-hydraulic model of a Printed Circuit Heat Exchanger. Subsequently, simulations of a base case, a parametric analysis, and an optimization using Genetic Algorithms, were carried out. Results show that there is a combination of operating conditions that maximizes the electrical output of the system. Besides, some values of the minimum pressure of the cycles can increase substantially the precooler cooling water pumping power. At the optimum design point, using a 20 kg/s geothermal brine stream at 150 °C as heat source with a minimum allowable reinjection temperature of 70 °C, the Intercooled Recuperated Brayton Cycle achieved the highest electric power output, energy and exergy efficiencies, obtaining values of 779.99 kW, 11.51%, and 52.49%, respectively. The other feasible alternatives were the Recuperated Brayton Cycle, the Simple Brayton Cycle and the Intercooled Brayton Cycle, ranked, in that order.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxidation Behavior of Welded Fe-Based and Ni-Based Alloys in Supercritical CO 2

Next-generation supercritical CO 2 (sCO 2 ) power cycles will require different classes of alloy throughout the operational temperatures to optimize tradeoff of creep strength, oxidation performance and cost. This will necessitate joining methods such as welding, which might pose compatibility concerns at the joined interfaces. In this study, similar and dissimilar metal welds were generated from a variety of candidate alloys for sCO 2 systems including ferritic/martensitic steels, austenitic steels, and Ni-based superalloys. Samples were extracted from different regions of the welds and exposed to sCO 2 at 550 °C and 20 MPa for 2500 h, then characterized to understand their behavior in this environment. Unsurprisingly, the local oxidation behavior was largely dictated by the Cr content in the underlying metal. High-Cr austenitic steels and Ni alloys formed slow-growing Cr-rich oxide scales with minimal carburization of the underlying metal, while low-Cr ferritic/martensitic steels formed fast-growing Fe-rich oxide scales with significant carburization. Most welds did not show any unusual oxidation behavior at the interfaces, considering the local Cr content. The one exception was the 347H similar metal weld, where a larger grain size and complex grain structure in the fusion zone led to a significantly higher rate of Fe-rich oxide nodule formation compared to the base metal. This suggests that microstructural changes at joined interfaces can play an important role on the oxidation-limited lifetimes in future sCO 2 systems. The composition changes across the interfaces enabled study of the effect of Fe on the growth rate of Cr-rich oxides and of the origins of the sub-surface recrystallization zone that forms beneath them.

36 MATERIALS SCIENCE↗

Coupled generator and combustor performance calculations for potential early commercial MHD power plants

A parametric study of the performance of the MHD generator and combustor components of potential early commercial open-cycle MHD/steam power plants is presented. Consideration is given to the effects of air heater system concept, MHD combustor type, coal type, thermal input power, oxygen enrichment of the combustion, subsonic and supersonic generator flow and magnetic field strength on coupled generator and combustor performance. The best performance is found to be attained with a 3000 F, indirectly fired air heater, no oxygen enrichment, Illinois no. 6 coal, a two-stage cyclone combustor with 85% slag rejection, a subsonic generator, and a magnetic field configuration yielding a constant transverse electric field of 4 kV/m. Results indicate that optimum net MHD generator power is generally compressor-power-limited rather than electric-stress-limited, with optimum net power a relatively weak function of operating pressure.

Dellinger, T. C.↗

Multi-spool CO2 aircraft power system for operating multiple generators

A CO 2 bottoming cycle system includes a first compressor operatively connected to a first turbine through a first shaft. A first generator is operatively connected to the first shaft. A second compressor is fluidically connected to the first compressor. The second compressor is operatively connected to a second turbine through a second shaft. A second generator is operatively connected to the second shaft. The first turbine is fluidically connected to the second turbine.

Taylor, Stephen H.↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Powering the Future

Stirling Technology Company (STC) developed the RG-350 convertor using components from separate Goddard Space Center and U.S. Army Natick SBIR contracts. Based on the RG-350, STC commercialized a product line of Stirling cycle generator sets, known as RemoteGen(TM), with power levels ranging from 10We to 3kWe. Under SBIR agreements with Glenn Research Center, the company refined and extended the capabilities of the RemoteGen convertors. They can provide power in remote locations by efficiently producing electricity from multiple-fuel sources, such as propane, alcohol, gasoline, diesel, coal, solar energy, or wood pellets. Utilizing any fuel source that can create heat, RemoteGen enables the choice of the most appropriate fuel source available. The engines operate without friction, wear, or maintenance. These abilities pave the way for self-powered appliances, such as refrigerators and furnaces. Numerous applications for RemoteGen include quiet, pollution-free generators for RVs and yachts, power for cell phone towers remote from the grid, and off-grid residential power variously using propane, ethanol, and solid biomass fuels. One utility and the National Renewable Energy Laboratory are evaluating a solar dish concentrator version with excellent potential for powering remote irrigation pumps.

Source record↗

System studies of coal fired-closed cycle MHD for central station power plants

This paper presents a discussion of the closed-cycle MHD results obtained in a recent study of various advanced energy-conversion power systems. The direct coal-fired MHD topping-steam bottoming cycle was established as the current choice for central station power generation. Emphasis is placed on the background assumptions and the conclusions that can be drawn from the closed-cycle MHD analysis. It is concluded that closed-cycle MHD has efficiencies comparable to that of open-cycle MHD. Its cost will possibly be slightly higher than that of the open-cycle MHD system. Also, with reasonable fuel escalation assumptions, both systems can produce lower-cost electricity than conventional steam power plants. Suggestions for further work in closed-cycle MHD components and systems are made.

Zauderer, B.↗

Evaluation of Ceramic Heat Exchanger for Next-Generation Concentrated Solar Power

The U.S. Department of Energy has identified a third generation of concentrated solar power (Gen3 CSP) technologies to minimize cost of CSP produced electricity. By developing these technologies further, it is forecasted that Gen3 CSP will meet the levelized cost of electricity (LCOE) SunShot target of 6 cents/kWh to compete with dominant, conventional nonrenewable energy sources (1). The focus for advancing CSP systems for Gen3 is to increase overall system efficiency. Thus, reevaluating second-generation systems, superheated steam-turbine power cycles, and implementing more advanced power cycles is essential. Specifically, it has been identified that a supercritical carbon dioxide (sCO 2 ) Brayton cycle can increase the net thermal-to-electric efficiency to over 50% for CSP power tower configurations (2). Compared to conventional superheated steam Rankine cycle systems, more extreme operating conditions are required and pose critical barriers to overcome in the field of materials and manufacturing for Gen3 CSP.

14 SOLAR ENERGY↗