Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Radial inlet guide vanes for a combustor

A combustor may include an interior flow path therethrough, a number of fuel nozzles in communication with the interior flow path, and an inlet guide vane system positioned about the interior flow path to create a swirled flow therein. The inlet guide vane system may include a number of windows positioned circumferentially around the fuel nozzles. The inlet guide vane system may also include a number of inlet guide vanes positioned circumferentially around the fuel nozzles and adjacent to the windows to create a swirled flow within the interior flow path.

42 ENGINEERING↗

A common-view disciplined oscillator

This paper describes a common-view disciplined oscillator (CVDO) that locks to a reference time scale through the use of common-view global positioning system (GPS) satellite measurements. The CVDO employs a proportional-integral-derivative controller that obtains near real-time common-view GPS measurements from the internet and provides steering corrections to a local oscillator. A CVDO can be locked to any time scale that makes real-time common-view data available and can serve as a high-accuracy, self-calibrating frequency and time standard. Measurement results are presented where a CVDO is locked to UTC(NIST), the coordinated universal time scale maintained at the National Institute of Standards and Technology in Boulder, Colorado.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

Establishing a Secure Data Center with Remote Access: Preprint

Access to existing travel data is critical for many analysis efforts that lack the time or resources to support detailed data collection. High-resolution data sets provide particular value, but also present a challenge for preserving the anonymity of the original survey participants. To address this dilemma of providing data access while preserving privacy, the National Renewable EnergyLaboratory and the U.S. Department of Transportation have launched the Transportation Secure Data Center (TSDC). TSDC data sets include those from regional travel surveys and studies that increasingly use global positioning system devices. Data provided by different collecting agencies varies with respect to formatting, elements included and level of processing conducted in support of theoriginal purpose. The TSDC relies on a number of geospatial and other analysis tools to ensure data quality and to generate useful information outputs. TSDC users can access the processed data in two different ways. The first is by downloading summary results and second-by-second vehicle speed profiles (with latitude/longitude information removed) from a publicly-accessible website. The secondmethod involves applying for a remote connection account to a controlled-access environment where spatial analysis can be conducted, but raw data cannot be removed. The TSDC website is http://www.nrel.gov/vehiclesandfuels/secure_transportation_data.html.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-precision frequency measurement of the 423-nm Ca i line

We have performed an accurate frequency calibration of the 4s{sup 2} {sup 1}S{sub 0{yields}}4s4p {sup 1}P{sub 1} principal resonance line of the neutral calcium atom at 423 nm. Doppler-free cw excitation on a Ca atomic beam was performed by utilizing a Sagnac geometry in the alignment of the excitation beams. From frequency calibrations against a frequency comb, stabilized to a global positioning system (GPS) disciplined Rb standard, the transition frequency is determined at 709 078 373.01(35) MHz for the main {sup 40}Ca isotope. Slightly lower accuracies are obtained for the transition frequencies of the less abundant isotopes. The achieved fractional uncertainty of 5x10{sup -10} exceeds the requirements for including this transition in investigations that aim to probe a possible variation in the fine-structure constant {alpha} on cosmological time scales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a GPS-Derived Troposphere Model to Improve InSAR Deformation Estimates in the San Gabriel Valley, California

We evaluate the potential of troposphere models derived from ground meteorological data (pressure, temperature, and relative humidity) and Global Positioning System (GPS) data to improve InSAR measurements and models derived from them. We test this approach on an ERS-2/Envisat data set collected during a transient surface deformation episode that occurred from January to July 2005 in the San Gabriel Valley, southern California, USA. We find that the interferometric phase change observed over the corresponding period cannot be solely attributed to hydrological uplift associated with rising groundwater levels but also includes a significant contribution from differential tropospheric delay due to differing quantities of water vapor in the troposphere on the two SAR observation dates. We show that, if the tropospheric phase contribution is mistakenly interpreted as the range change associated with changes in groundwater storage, both the surface displacement and the groundwater storage coefficient may be overestimated by up to 30%. Finally, this method could be applied in real time where meteorological measurements are available near one or more GPS permanent site(s).

54 ENVIRONMENTAL SCIENCES↗

Convective-Permitting Hindcast Simulations during the North American Monsoon GPS Transect Experiment 2013: Establishing Baseline Model Performance without Data Assimilation

During the North American monsoon global positioning system (GPS) Transect Experiment 2013, daily convective-permitting WRF simulations are performed in northwestern Mexico and the southern Arizona border region using the operational Global Forecast System (GFS) and North American Mesoscale Forecast System (NAM) models as lateral boundary forcing and initial conditions. Compared to GPS precipitable water vapor (PWV), the WRF simulations display a consistent moist bias in the initial specification of PWV leading to convection beginning 3–6 h early. Given appreciable observed rainfall, days are classified as strongly and weakly forced based only on the presence of an inverted trough (IV); gulf surges did not noticeably impact the development of mesoscale convective systems (MCSs) and related convection in northwestern Mexico. Strongly forced days display higher modeled precipitation forecast skill than weakly forced days in the slopes of the northern Sierra Madre Occidental (SMO) away from the crest, especially toward the west where MCSs account for the greatest proportion of all monsoon-related precipitation. A case study spanning 8–10 July 2013 illustrates two consecutive days when nearly identical MCSs evolved over northern Sonora. Although a salient MCS is simulated on the strongly forced day (9–10 July 2013) when an IV is approaching the core monsoon region, a simulated MCS is basically nonexistent on the weakly forced day (8–9 July 2013) when the IV is farther away. Finally, the greater sensitivity to the initial specification of PWV in the weakly forced day suggests that assimilation of GPS-derived PWV for these types of days may be of greatest value in improving model precipitation forecasts.

54 ENVIRONMENTAL SCIENCES↗

Deformation analysis of Aceh April 11{sup th} 2012 earthquake using GPS observation data

This research tries to estimate the co-seismic deformation of intraplate earthquake occurred off northern Sumatra coast which is about 100-200 km southwest of Sumatrasubduction zone. The earthquake mechanism was strike-slip with magnitude 8.6 and triggering aftershock with magnitude 8.2 two hours later. We estimated the co-seismic deformation by using the GPS (Global Positioning System) continuous data along western Sumatra coast. The GPS observation derived from Sumatran GPS Array (SuGAr) and Geospatial Information Agency (BIG). For data processing we used GPS Analyze at Massachusetts Institute of Technology (GAMIT) software and Global Kalman Filter (GLOBK) to estimate the co-seismic deformation. From the GPS daily solution, the result shows that the earthquake caused displacement for the GPS stations in Sumatra. GPS stations in northern Sumatra showed the displacement to the northeast with the average displacement was 15 cm. The biggest displacement was found at station BSIM which is located at Simeuleu Island off north west Sumatra coast. GPS station in middle part of Sumatra, the displacement was northwest. The earthquake also caused subsidence for stations in northern Sumatra, but from the time series there was not sign of subsidence was found at middle part of Sumatra. In addition, the effect of the earthquake was worldwide and affected the other GPS Stations around Hindia oceanic.

58 GEOSCIENCES↗

A National Tracking Center for Monitoring Shipments of HEU, MOX, and Spent Nuclear Fuel: How do we implement?

Nuclear material safeguards specialists and instrument developers at US Department of Energy (USDOE) National Laboratories in the United States, sponsored by the National Nuclear Security Administration (NNSA) Office of NA-24, have been developing devices to monitor shipments of UF6 cylinders and other radioactive materials , . Tracking devices are being developed that are capable of monitoring shipments of valuable radioactive materials in real time, using the Global Positioning System (GPS). We envision that such devices will be extremely useful, if not essential, for monitoring the shipment of these important cargoes of nuclear material, including highly-enriched uranium (HEU), mixed plutonium/uranium oxide (MOX), spent nuclear fuel, and, potentially, other large radioactive sources. To ensure nuclear material security and safeguards, it is extremely important to track these materials because they contain so-called “direct-use material” which is material that if diverted and processed could potentially be used to develop clandestine nuclear weapons . Large sources could be used for a dirty bomb also known as a radioactive dispersal device (RDD). For that matter, any interdiction by an adversary regardless of intent demands a rapid response. To make the fullest use of such tracking devices, we propose a National Tracking Center. This paper describes what the attributes of such a center would be and how it could ultimately be the prototype for an International Tracking Center, possibly to be based in Vienna, at the International Atomic Energy Agency (IAEA).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Depleted Uranium Discrimination Using Spectral Ratios from Data-Starved Spectra - 18619

The Institute for Clean Energy Technology (ICET) has developed mobile surveying platforms for the retrieval of fired depleted uranium (DU) munitions. ICET surveying platforms are fitted with differential global positioning system (GPS), scintillation detectors, and central processing units (CPUs). The surveying technology has historically been used to assist facilities where DU contamination is a concern to locate, retrieve, and remediate DU-contaminated areas. Residence times over DU sources for mobile systems normally do not produce enough data to use gamma ray spectroscopy to verify the source type. Discussed is a potential method used to discriminate DU signatures in data-starved gamma ray spectral data collected during field surveys. Laboratory tests have shown that data-starved gamma ray spectra for zero-valence, oxide, and uranium ores can be distinguished from each other and from background by spectral ratioing. Zero-valence DU and DU oxide gamma ray signatures differ due to the attenuation of low-energy gammas emitted from U-238 daughters. DU signatures can be differentiated from naturally occurring uranium spectra due to the presence of daughters below U-234, primarily bismuth (Bi)-214, in the uranium decay series. Three primary regions of interest (ROI) within the analyzed test spectra are used to roughly characterize the shape of each test spectrum and compare them to background. The three ROIs are focused around the gamma-emitting daughters of U-238: thorium (Th)-234, protactinium (Pa)-234 metastable (m), and Bi-214. One of the three regions is considered the base region. This region is used to estimate what the counts in the other two regions should be by multiplying the counts in the ROIs by a ratio of background counts from an area previously found to be impacted. Using this spectral ratioing technique, a non-zero difference in spectral ratio values indicates a shift in the test spectra away from background. Calculating ratios between the base region and the other two regions allows for a graphical representation of the data in a two-dimensional spectral ratioing space, which is used to differentiate between the types of uranium sources previously mentioned. Surveying processes that are based on gross counts from scintillation counters can result in a large number of false positives as a result of shifting background signals or the presence of naturally occurring uranium. Application of the spectral ratioing technique can further assist in site characterization by analyzing all of the data-starved survey spectra to identify false positives or the need for additional data collection. Accurate surveys of DU testing and training ranges reduces the costs associated with range clean-up by discriminating clean areas from those requiring remediation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microwave and Millimeter-Wave Radiometric Studies of Temperature, Water Vapor and Clouds

The importance of accurate measurements of column amounts of water vapor and cloud liquid has been well documented by scientists within the Atmospheric Radiation Measurement (ARM) Program. At the North Slope of Alaska (NSA), both microwave radiometers (MWR) and the MWRProfiler (MWRP), been used operationally by ARM for passive retrievals of the quantities: Precipitable Water Vapor (PWV) and Liquid Water Path (LWP). However, it has been convincingly shown that these instruments are inadequate to measure low amounts of PWV and LWP. In the case of water vapor, this is especially important during the Arctic winter, when PWV is frequently less than 2 mm. For low amounts of LWP (< 50 g/m{sup 2}), the MWR and MWRP retrievals have an accuracy that is also not acceptable. To address some of these needs, in March-April 2004, NOAA and ARM conducted the NSA Arctic Winter Radiometric Experiment - Water Vapor Intensive Operational Period at the ARM NSA/Adjacent Arctic Ocean (NSA/AAO) site. After this experiment, the radiometer group at NOAA moved to the Center for Environmental Technology (CET) of the Department of Electrical and Computer Engineering of the University of Colorado at Boulder. During this 2004 experiment, a total of 220 radiosondes were launched, and radiometric data from 22.235 to 380 GHz were obtained. Primary instruments included the ARM MWR and MWRP, a Global Positioning System (GPS), as well as the CET Ground-based Scanning Radiometer (GSR). We have analyzed data from these instruments to answer several questions of importance to ARM, including: (a) techniques for improved water vapor measurements; (b) improved calibration techniques during cloudy conditions; (c) the spectral response of radiometers to a variety of conditions: clear, liquid, ice, and mixed phase clouds; and (d) forward modeling of microwave and millimeter wave brightness temperatures from 22 to 380 GHz. Many of these results have been published in the open literature. During the third year of this contract, we participated in another ARM-sponsored experiment at the NSA during February-March 2007. This experiment is called the Radiative Heating in Underexplored Bands Campaign (RHUBC) and the GSR was operated successfully for the duration of the campaign. One of the principal goals of the experiment was to provide retrievals of water vapor during PWV amounts less than 2 mm and to compare GSR data with ARM radiometers and radiosondes. A secondary goal was to compare the radiometric response of the microwave and millimeter wavelength radiometers to water and ice clouds. In this final report, we will include the separate progress reports for each of the three years of the project and follow with a section on major accomplishments of the project.

54 ENVIRONMENTAL SCIENCES↗

Analysis framework for systematically studying ionospheric response to impulsive events from below: Analysis Framework Ionospheric Responses

We present that impulsive phenomena in the Earth's atmosphere produce acoustic and gravity waves which perturb the ionosphere. Such perturbations are often measured using total electron content fluctuations (TEC), derived from ground-based Global Positioning System data. Using TEC data from the Japanese GEONET ground network after the Tōhoku earthquake on 11 March 2011, we demonstrate capabilities of a new framework of methodologies for analyzing ionospheric perturbations. The framework consists of several new techniques: calculating velocity along a single direction to reduce error due to anisotropic propagation, producing normalized bidirectional band-pass spectra that preserve relative timing between various frequencies and allowing a more systematic determination of broadband pulses, and utilizing a wavelet-based technique that considers instantaneous wave phase changes, rather than best fit time differences, to evaluate wave characteristics (speed, direction, and wavelength) within spectral ranges of interest. Using these techniques together decreases subjectivity and reduces errors in attributing fluctuations to given sources. In validating this framework using the Tōhoku case, we consistently identify three kinds of waves: a broad-band pulse (speed: >2000 m/s, max range: >1400 km) arriving in the ionosphere 10–15 min after the quake, acoustic waves following the pulse (period: 3–5 min, speed: 700–1000 m/s, max range: <500 km), and gravity waves (period: 10–15 min, speed: 150–500 m/s, max range: >1400 km) propagating away from the epicenter, consistent with theory and demonstrated in previous studies. Lastly, this framework also can be applied to other impulsive events in the atmosphere that are more difficult to detect and attribute to sources.

58 GEOSCIENCES↗

GPS-Based Gamma Survey for Characterizing and Decommissioning NORM Sites - 20389

Gamma survey techniques are an especially powerful decommissioning tool at naturally occurring radioactive material (NORM) sites due to both the low cost to obtain data over a large spatial scale and the abundance of gamma emitters in the uranium and thorium decay series. Gamma surveys are executed by coupling a detector - most often a sodium iodide crystal - to a global positioning system (GPS), then reporting a location and gross gamma reading coincidentally to a data logger. Systems may be carried by workers or mounted to a car, all-terrain vehicle, or unmanned aerial system (UAS). The resulting data set provides a high-resolution but low precision map of the gamma radiation field over the area surveyed. Frequently this map is also correlated to soil concentrations of NORM radionuclides (most often, Ra-226) and/or exposure rate. Gamma survey parameters such as movement speed, transect spacing, and data logging frequency define the spatial resolution of the resulting surface, and can be optimized depending on the desired survey sensitivity. This paper examines gamma survey as a tool for decommissioning NORM sites and provides an overview of current gamma survey technology designed to improve the efficiency and effectiveness of the decommissioning process. Topics to be discussed in the paper include: - An overview of gamma survey systems, and the utility of different delivery vehicles depending on desired cost, desired spatial resolution, and site topography. - The influence of physical detector characteristics on detection sensitivity and survey planning. - The tradeoff between high-resolution and large spatial extent, but inherently uncertain data, and low-resolution, low spatial extent, but highly certain data, as well as the specific utility of each of these types of data during NORM facility decommissioning. - Confounding variables that may limit the utility of gamma survey at some sites (e.g., radon gas and spatial heterogeneity / hot spots), and methods to plan for and control these conditions. Results show that the confounding variables, such as radon and data output can greatly influence the overall data quality associated with the decommissioning process. In addition, the use of real-time and aerial survey platforms provides a method for ensuring proper spatial extent of the data. When applied thoughtfully, gamma survey is a powerful tool for detecting NORM radionuclides in the environment and a cost-effective technique for identifying areas requiring remediation. However, entities performing or using gamma survey as a decommissioning tool must be aware of both its advantages and its limitations before basing remediation or regulatory action on gamma survey results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of rf power on electron density and temperature, neutral temperature, and T{sub e} fluctuations in an inductively coupled plasma

Atomic clocks that fly on global-navigation satellites such as global positioning system (GPS) and Galileo employ light from low-temperature, inductively coupled plasmas (ICPs) for atomic signal generation and detection (i.e., alkali/noble-gas rf-discharge lamps). In this application, the performance of the atomic clock and the capabilities of the navigation system depend sensitively on the stability of the ICP's optical emission. In order to better understand the mechanisms that might lead to instability in these rf-discharge lamps, and hence the satellite atomic clocks, we studied the optical emission from a Rb/Xe ICP as a function of the rf power driving the plasma. Surprisingly, we found that the electron density in the plasma was essentially independent of increases in rf power above its nominal value (i.e., 'rf-power gain') and that the electron temperature was only a slowly varying function of rf-power gain. The primary effect of rf power was to increase the temperature of the neutrals in the plasma, which was manifested by an increase in Rb vapor density. Interestingly, we also found evidence for electron temperature fluctuations (i.e., fluctuations in the plasma's high-energy electron content). The variance of these fluctuations scaled inversely with the plasma's mean electron temperature and was consistent with a simple model that assumed that the total electron density in the discharge was independent of rf power. Taken as a whole, our results indicate that the electrons in alkali/noble-gas ICPs are little affected by slight changes in rf power and that the primary effect of such changes is to heat the plasma's neutral species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of heavy metals in seawater and fish tissues at Pulau Indah, Selangor, Malaysia

This study focuses on the levels of heavy metals in seawater and selected fish tissue at Pulau Indah, Selangor, Malaysia. Pulau Indah primarily contains Westport (Malaysia’s major port), and a host of full scales factories. Therefore, it is important to monitor the levels of pollution in this water body and the aquatic organisms in the long term effects, due to the human activities in this area. Water samples in this study were taken from 8 locations along the coastal area. The water samples were collected using water sampler and sampling locations were determined using a Global Positioning system (GPS). Similarly, in situ water quality parameters including temperature, dissolve oxygen (DO), salinity, total suspended solid (TSS), pH and turbidity were measured by using portable multi probes meter. Then, the samples were acidified until pH 2 and filtered. Fish samples were purchased from local fisherman along the Pulau Indah coastal area and samples were digested using concentrated nitric acid in wet digestion method. The levels of selected heavy metals in four species of fish and seawater from Pulau Indah coastal area were determined using Inductive Coupled Plasma Mass Spectrometer (ICPMS) after dilution to the samples. In general, the quality of water at Pulau Indah is lower than Malaysia Marine Water Quality Standard except for few locations were higher than the maximum permissible levels. The concentration of heavy metals which are lead (Pb), copper (Cu), zinc (Zn) and uranium (U) in water samples are in the range of 0.36-5.43 µg/L, 75.20-621.58 µg/L, 11.92-30.52 µg/L, and 4.00-4.65 µg/L respectively. While the results of the four selected fish showed the following order of abundance Zn> U> Cu> Pb. Transfer factor (TF) of heavy metals in fish tissue of selected fish species from the water was discussed. However, the observed metal concentration in the sample tissue did not exceed the allowable limit of Malaysian Food Act (1983) and Regulation (1985). Therefore, it is safe for human consumption. Moreover, the pollution levels of these heavy metals were also compared with other studies. This present study can also be used to evaluate the safety dose uptake level of marine biota as well as to monitor environmental health.

54 ENVIRONMENTAL SCIENCES↗

A new interpretation of deformation rates in the Snake River Plain and adjacent basin and range regions based on GPS measurements

We evaluate horizontal Global Positioning System (GPS) velocities together with geologic, volcanic, and seismic data to interpret extension, shear, and contraction within the Snake River Plain and the Northern Basin and Range Province, U.S.A. We estimate horizontal surface velocities using GPS data collected at 385 sites from 1994 to 2009 and present an updated velocity field within the Stable North American Reference Frame (SNARF). Our results show an ENE-oriented extensional strain rate of 5.9 {+-} 0.7 x 10{sup -9} yr{sup -1} in the Centennial Tectonic belt and an E-oriented extensional strain rate of 6.2 {+-} 0.3 x 10{sup -9} yr{sup -1} in the Intermountain Seismic belt combined with the northern Great Basin. These extensional strain rates contrast with the regional north-south contraction of -2.6 {+-} 1.1 x 10{sup -9} yr{sup -1} calculated in the Snake River Plain and Owyhee-Oregon Plateau over a 125 x 650 km region. Tests that include dike-opening reveal that rapid extension by dike intrusion in volcanic rift zones does not occur in the Snake River Plain at present. This slow internal deformation in the Snake River Plain is in contrast to the rapidly-extending adjacent Basin and Range provinces and implies shear along boundaries of the Snake River Plain. We estimate right-lateral shear with slip rates of 0.5-1.5 mm/yr along the northwestern boundary adjacent to the Centennial Tectonic belt and left-lateral oblique extension with slip rates of <0.5 to 1.7 mm/yr along the southeastern boundary adjacent to the Intermountain Seismic belt. The fastest lateral shearing occurs near the Yellowstone Plateau where strike-slip focal mechanisms and faults with observed strike-slip components of motion are documented. The regional GPS velocity gradients are best fit by nearby poles of rotation for the Centennial Tectonic belt, Idaho batholith, Snake River Plain, Owyhee-Oregon Plateau, and central Oregon, indicating that clockwise rotation is driven by extension to the south in the Great Basin and not localized extension in the Basin and Range or Yellowstone hotspot volcanism. We propose that the GPS velocity field reflects the regional deformation pattern since at least 15-12 Ma, with clockwise rotation over the Northern Basin and Range Province consistent with Basin and Range extension initiating 16 Ma. The region modified by hotspot volcanism has a low-strain rate. If we assume the low rate of deformation is reflected in the length of time between eruptions on the order of 10{sup 4} to >10{sup 6} yrs, the low-strain field in the Snake River Plain and Owyhee-Oregon Plateau would extend through the Quaternary.

58 GEOSCIENCES↗

Three Dimensional Characterization of Defects by Ultrasonic Time-of-Flight Diffraction (ToFD) Technique

Ultrasonic time-of-flight diffraction (ToFD) technique has high accuracy in locating and sizing discontinuities. The primary reason for this accuracy is the use of time instead of amplitude for measurement of the depth and size of discontinuities. Despite the many advantages of ToFD, it suffers from a number of shortcomings, the most notable one being its two-dimensional character. The goal of this paper is to develop an algorithm, as a prerequisite, to extend ToFD measurements to a three-dimensional space. For this purpose, a combination of multiple transmitting and receiving probes is proposed instead of just one pair commonly used in ToFD measurements. The approach for locating and sizing defects in a 3D space follows the methods used in radar and acoustic positioning systems. Non-iterative techniques are used for positioning a single source (defect) based on signals collected by several transducers. The estimation formula, in the form of a closed-form solution, is derived by linear least-squares minimization. In addition to existing conventional passive algorithms, a new active algorithm is also proposed for the general arrangement of transducers. This algorithm is tested on a steel specimen having an artificially implanted discontinuity and the three-dimensional location of the defect is estimated.

42 ENGINEERING↗

A Research Testbed for Experimental Connectivity and Automation in Cars

Cyber-physical systems (CPS) are engineered systems in which the computational components and physical components of the system are interdependent and deeply linked. Discovery and development of CPS technologies are changing the way people interact with engineered systems. To demonstrate this point, consider the Global Positioning System (GPS) which revolutionized personal mobility. Its research origins stem from the US Department of Defense in 1973 for military use. By 2000 limitations on civilian consumption of GPS service were lifted. Immediately, personal GPS products were shipped for in-car navigation systems. Soon after, GPS receivers were embedded into mobile phones with the introduction of the Nokia N95 and Apple iPhone for maps and turn-by-turn navigation. With the benefit of hindsight we can see that GPS has become a cornerstone technology of our daily life. Satellite-based navigation has gone from a radical space technology, to a matter of uninteresting availability; it is the typical way that people navigate through roadways now. The combination of the satellite infrastructure, the integration of receiver modules, and powerful maps applications has significantly changed mobility in the 21st century.

42 ENGINEERING↗