Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Classification of Ice Crystal Habits Using Combined Lidar and Scanning Polarimeter Observations during the SEAC4RS Campaign

Using collocated NASA Cloud Physics Lidar (CPL) and Research Scanning Polarimeter (RSP) data from the Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) campaign, a new observational-based method was developed which uses a K-means clustering technique to classify ice crystal habit types into seven categories: column, plates, rosettes, spheroids, and three different type of irregulars. Intercompared with the collocated SPEC, Inc., Cloud Particle Imager (CPI) data, the frequency of the detected ice crystal habits from the proposed method presented in the study agrees within 5% with the CPI-reported values for columns, irregulars, rosettes, and spheroids, with more disagreement for plates. This study suggests that a detailed ice crystal habit retrieval could be applied to combined space-based lidar and polarimeter observations such as CALIPSO and POLDER in addition to future missions such as the Aerosols, Clouds, Convection, and Precipitation (A-CCP).

Natalie Midzak↗

Construction and Testing of Data Acquisition Components for the Hall A Compton Polarimeter

Nuclear physics experiments require accurate knowledge of the spin polarization of the electron beam delivered to the experimental halls. Hall A is upgrading its Compton polarimeter in support of the lab's 12 GeV beam energy upgrade. This project centered around the data acquisition (DAQ) system for the scattered-photon detection component of the polarimeter. The goal was to test whether the DAQ software and hardware are capable of capturing, recording, and processing electron helicity-dependent scattering rate asymmetry data at high rates, while maintaining appropriate accuracy. We created the necessary circuits, and are able to reliably extract asymmetries of between 0.5{\%} and 11.5{\%} to 0.2{\%}. We did this in a deadtime-free regime at rates between 100 KHz and 350 KHz. We currently are unable to measure the system deadtime after it becomes manifest at about 350 KHz. These tests support the use of a scaled version of this configuration.

Hill, Joshua↗

Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2 SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute spin calibration of an electron spin polarimeter by spin-resolved photoemission from the Au(111) surface states

Here we report the absolute characterization of a spin polarimeter by measuring the Sherman function with high precision. These results have been obtained from the analysis of the spin and angle-resolved photoemission spectra of Au(111) surface states. The measurements have been performed with a 250 kHz repetition rate Ti:sapphire amplified laser system combined with a high energy-, angle-, and spin-resolving time-of-flight electron spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Spectroscopy of Hydrogen with a Lamb-Shift Polarimeter

A spinfilter, the most important component of a Lamb-shift polarimeter, is used to produce a beam of metastable hydrogen (deuterium) atoms in one hyperfine state (HFS)(alpha1, alpha2 and together with the Sona transition beta3). As function of a magnetic field separated transitions between the 2s{sub 1/2} metastable Zeeman states seem to be observable as well as single transitions into the short-lived 2P{sub 1/2} and 2P{sub 3/2} states. The Breit-Rabi diagrams for these states and, therefore, the g factors can be measured with good precision. Furthermore, the hyperfine splittings and the Lamb shift can be observed as well. Application of this method to anti-hydrogen atoms is suggested.

74 ATOMIC AND MOLECULAR PHYSICS↗

A new calibration code for the JET polarimeter

An equivalent model of JET polarimeter is presented, which overcomes the drawbacks of previous versions of the fitting procedures used to provide calibrated results. First of all the signal processing electronics has been simulated, to confirm that it is still working within the original specifications. Then the effective optical path of both the vertical and lateral chords has been implemented to produce the calibration curves. The principle approach to the model has allowed obtaining a unique procedure which can be applied to any manual calibration and remains constant until the following one. The optical model of the chords is then applied to derive the plasma measurements. The results are in good agreement with the estimates of the most advanced full wave propagation code available and have been benchmarked with other diagnostics. The devised procedure has proved to work properly also for the most recent campaigns and high current experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear Polarization Measurements with a New Soft X-Ray Polarimeter and Ellipsometer at a Bending Magnet Beamline of a Compact Storage Ring

Linear polarization measurements were carried out using a newly developed soft x-ray polarimeter and ellipsometer (SXPE) for complete polarization analysis at a soft x-ray beamline (BL-11) of the SR Center, Ritsumeikan University, Japan. A Mo/Si multilayer mirror (period: 10.36 nm, ratio of Mo layer to period: 0.64, and 23 bilayers with topmost Si layer) was deposited on the surface of a commercial Si(111) substrate by an ion beam sputtering method. It was cut into two pieces which were then used as reflection-type polarizers. When the incident wavelength was scanned from 12.4 nm to 14.8 nm by a Monk-Gillieson type varied-line-spacing grating monochromator of the BL-11, the angles of incidence of both the Mo/Si multilayer polarizers in the SXPE were also varied from 37.5 deg. to 52.3 deg. The polarizances depended strongly on the wavelength, and the best performance of over 99% was obtained in the vicinity of 14 nm. Using these polarizers, we assessed that the degree of linear polarization of the BL-11 was almost constant at 85-88% in the measured wavelength range.

43 PARTICLE ACCELERATORS↗

Preliminary results from the Alcator C-Mod polarimeter

A poloidally viewing far infrared polarimeter diagnostic is being developed for the Alcator C-Mod tokamak, and will be used to determine the q-profile and to study density and magnetic field fluctuations. A three-chord version of what will eventually be up to a ten-chord system has been designed and fabricated and will be installed on C-Mod before the end of the current run period. Bench tests of a single chord mock-up of this system show acceptable noise levels for the planned measurements. We will discuss the analysis and experimental techniques used to diagnose and reduce noise sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent developments of the JET far-infrared interferometer-polarimeter diagnostic

The far-infrared diagnostic provides essential internal measurements of the plasma density and magnetic field topology (q-profile via Faraday rotation angle) in real-time. The diagnostic capabilities have recently been extended in a number of key areas. Fast interferometer data, with 10 {mu}s time resolution, and a new MATLAB code have allowed improved analysis of the evolution of density profiles during fast events such as vertical plasma displacements, edge localized mode, pellet fuelling, and disruptions. Using the polarimeter measurements in real-time, a new calibration procedure has been developed based on a propagation code using the Mueller matrix formalism. A further major upgrade of the system is presently underway: adding a second color laser to the vertical channels and implementing a new phase counter based on analog zero crossing and field-programmable gate array boards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of two color laser diagnostics for the ITER poloidal polarimeter

Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 {mu}m by using a twin optically pumped CH{sub 3}OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-Ray Burst Polarimeter aboard IKAROS

A GRB polarimeter was launched by H-IIA on 21 May in 2010 at JAXA Tanegashima Space Center. A GRB polarization is the best key to understand mechanism of GRB prompt emissions and also to understand the geometry of magnetic fields. The standard GRB fireball models predict the synchrotron radiation of them, thus a high degree of polarization is expected, if the magnetic field-lines are coaligned. Previously, a few of the GRB polarization detections were reported. Although they used the Compton scattering method, but their measurements were non-coincidence mode. This made their reports were somewhat unclear. This time, our detector works fully in the coincidence mode to avoid the confusion. On 21 June, GAP is switched on and the first GRB was detected on 7 July but not yet well calibrated.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of the Faraday angle by numerical methods and comparison with the Tore Supra and JET polarimeter electronics

On the Tore Supra tokamak, a far infrared polarimeter diagnostic has been routinely used for diagnosing the current density by measuring the Faraday rotation angle. A high precision of measurement is needed to correctly reconstruct the current profile. To reach this precision, electronics used to compute the phase and the amplitude of the detected signals must have a good resilience to the noise in the measurement. In this article, the analogue card's response to the noise coming from the detectors and their impact on the Faraday angle measurements are analyzed, and we present numerical methods to calculate the phase and the amplitude. These validations have been done using real signals acquired by Tore Supra and JET experiments. These methods have been developed to be used in real-time in the future numerical cards that will replace the Tore Supra present analogue ones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a millimeter-wave polarimeter for NSTX-Upgrade and initial test on DIII-D

Polarimetry is a powerful diagnostic technique to probe plasma equilibria and magnetic fluctuations in fusion plasmas. In a high beta plasma such as the National Spherical Torus eXperiment (NSTX), these measurements are important to understand plasma stability and anomalous transport. A 288 GHz polarimeter operating along a major radial chord in retroreflection geometry has been developed and is being tested on the DIII-D tokamak to prepare for future implementation on NSTX-Upgrade. The system launches a rotating linearly polarized beam and detects the phase shift directly related to the polarization change caused by the plasma. To accomplish this, a pair of orthogonal linearly polarized beams with a stable difference frequency is generated using a single sideband modulation technique, then combined and transformed to be counter-rotating circularly polarized. To improve phase resolution, quasi-optical isolation, using Faraday rotators and polarizers, is utilized to eliminate a multi-path feedback effect, which is found to be the primary source of phase error. The bench tests in the laboratory and DIII-D power supply test discharges indicate {<=}1 Degree-Sign phase resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of the tangentially viewing combined interferometer-polarimeter for ITER density measurements

One of the systems planned for the measurement of electron density in ITER is a multi-channel tangentially viewing combined interferometer-polarimeter (TIP). This work discusses the current status of the design, including a preliminary optical table layout, calibration options, error sources, and performance projections based on a CO{sub 2}/CO laser system. In the current design, two-color interferometry is carried out at 10.59 {mu}m and 5.42 {mu}m and a separate polarimetry measurement of the plasma induced Faraday effect, utilizing the rotating wave technique, is made at 10.59 {mu}m. The inclusion of polarimetry provides an independent measure of the electron density and can also be used to correct the conventional two-color interferometer for fringe skips at all densities, up to and beyond the Greenwald limit. The system features five chords with independent first mirrors to reduce risks associated with deposition, erosion, etc., and a common first wall hole to minimize penetration sizes. Simulations of performance for a projected ITER baseline discharge show the diagnostic will function as well as, or better than, comparable existing systems for feedback density control. Calculations also show that finite temperature effects will be significant in ITER even for moderate temperature plasmas and can lead to a significant underestimate of electron density. A secondary role TIP will fulfill is that of a density fluctuation diagnostic; using a toroidal Alfven eigenmode as an example, simulations show TIP will be extremely robust in this capacity and potentially able to resolve coherent mode fluctuations with perturbed densities as low as {delta}n/n Almost-Equal-To 10{sup -5}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high spatial resolution Stokes polarimeter for motional Stark effect imaging

We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An electron beam polarimeter based on scattering from a windowless, polarized hydrogen gas target

Here we present the idea to develop a precision polarimeter for low energy, intense polarized electron beams using a windowless polarized hydrogen gas cell fed by an atomic beam source. This technique would use proven technology used successfully in both the electron scattering experiments: HERMES with 27 GeV electron and positron beams at DESY, and BLAST with 850 MeV electron beams at MIT-Bates. At 100 MeV beam energy, both spin-dependent Mo/ller and elastic electron-proton scattering processes have a high cross section and sizable spin asymmetries. The concept is described and estimates for realistic rates for elastic electron-proton scattering and Mo/ller scattering are presented. A number of important issues which affect the ultimate systematic uncertainty are identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Faraday-effect polarimeter-interferometer system for current density measurement on EAST

A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide real-time Faraday rotation angle and density phase shift output, have been developed for use on the POINT system. Initial calibration indicates the electron line-integrated density resolution is less than 5 × 10{sup 16} m{sup −2} (∼2°), and the Faraday rotation angle rms phase noise is <0.1°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical layout and mechanical structure of polarimeter-interferometer system for Experimental Advanced Superconducting Tokamak

A Far-InfaRed (FIR) three-wave POlarimeter-INTerferometer (POINT) system for measurement current density profile and electron density profile is under development for the EAST tokamak. The FIR beams are transmitted from the laser room to the optical tower adjacent to EAST via ∼20 m overmoded dielectric waveguide and then divided into 5 horizontal chords. The optical arrangement was designed using ZEMAX, which provides information on the beam spot size and energy distribution throughout the optical system. ZEMAX calculations used to optimize the optical layout design are combined with the mechanical design from CATIA, providing a 3D visualization of the entire POINT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗