Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plugs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Automatic Receptacle Controls: Evaluating the clarity of receptacle markings

Plug loads and the electric loads of devices plugged into receptacles in commercial buildings play a significant and growing role in commercial buildings. Because plug loads are portable and are often placed in the building by the occupants, they are a challenging load to manage. This report summarizes an analysis of commercially available automatic receptacle controls (ARCs). As a part of this study, generic versions of ARCs were presented to a general user audience via an online survey, wherein survey respondents indicated which markings more clearly indicated that the receptacle was controlled. A total of 210 responses were collected and included in the analysis presented in this report. The results showed that receptacles with high-contrast markings were consistently clearer and more evident to the users than low-contrast markings. The survey responses also revealed that receptacles with a border drawn around each controlled receptacle were clearer and distinct to the users compared to other markings. These results led to the conclusion that for energy saving technology to be effective, consistent and easy to understand markings are necessary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Context and mitigation of lost circulation during geothermal drilling in diverse geologic settings

Lost circulation is one of the most common and expensive problems facing geothermal energy development, representing up to 30% of drilling costs. We examined drilling records from four geothermal fields—McGinness Hills in central Nevada, Don A. Campbell and Steamboat Hills in western Nevada, and Puna Geothermal Venture on the Big Island of Hawai'i— to identify geologies most prone to lost circulation, as well as common mitigation strategies. Depths of lost circulation events varied, but their frequency often increased in the production interval. Lost circulation commonly occurred near fault intersections, and heavily faulted fields like McGinness Hills and Don A. Campbell showed secondary mineralization within approximately 100 m (328 ft) or less of where circulation was lost. Lost circulation mitigation strategies included using locally available materials (e.g., cotton seed hulls) as well as more expensive proprietary lost circulation materials, cement plugs above the reservoir, and drilling blind with aerated, polymer-based mud in the production zone. Addressing lost circulation using a well thought out decision-making approach and materials above the reservoir will save time and cost, and provide needed well integrity. Mitigation often requires a series of steps, typically applied from perceived least expensive to most, and are dependent on the severity and location in the well where circulation was lost and availability of materials. Placing cement plugs can cure lost circulation events, however these plugs are often expensive, time-consuming, and may not be successful.

15 GEOTHERMAL ENERGY↗

Siting and sizing of public–private charging stations impacts on household and electric vehicle fleets

To facilitate the provision of electric vehicle charging stations (EVCS) in urban areas, this study investigates the benefits of co-locating fleet-owned chargers with public charging stations to enable construction incentives and cord-sharing cost savings. Shared EVCS can serve charging demand from both user types: private (household) EV owners and those managing fleet vehicles – like shared and fully automated EV (SAEV) fleets. Using POLARIS to simulate all person-travel across the 6-county Austin, Texas region, new EVCS were sited and sized with DC fast-charging (DCFC) plugs to lower operating and construction costs while providing public + private (PP) service across an 81-square-mile core geofence (where 200 SAEVs were active) over 24-hour days. When co-location is permitted, 115 DCFC cords were added to the 23 existing (publicly available) stations to enable SAEVs and household EVs (HHEVs) charging access, within the geofence. Each 250-mile-range SAEV was simulated to travel an average of 330 miles per day, serve over 92 person-trips, and recharge 2.7 times a day (for 2.4 h per session). The new DCFC plugs were primarily added to public EVCS at shopping centers and schools, and in residential settings along freeways. The average plug served 4.8 EVs per day. Most co-located PP EVCS permitted immediate (no-wait) charging, except for 2 stations along freeways that averaged 8 min of wait time to begin charging. In conclusion, the co-location strategy lowered fleet owners’ initial EVCS construction costs by 12 % (thanks to cord-sharing to avoid cord duplication), while reducing SAEV wait times to just 3.1 min (versus 10.7 min if SAEV managers had to build and operate their own EVCS).

EV charging modeling↗

Observation of asymmetric explosive density evolution in the deflagration-to-detonation transition for porous explosives

We report deflagration-to-detonation transition phenomena in cylindrical columns of porous explosives based on octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). The HMX powder and LX-14 (95.5 wt. % HMX and 4.5 wt. % estane polyurethane) prills were observed with high-speed cameras and flash x rays under conditions that allow for precise scaling and registration of the recorded images. These experimental results test the conventional assumption of axisymmetric, effective one-dimensional burning. Polycarbonate confinement tubes allowed this direct imaging with steel spheres employed as radio-opaque fiducials. Spheres embedded in the explosive column revealed the displacement of the explosive prior to deflagration. X-ray and fast camera images show that a dense plug of compact explosive develops ahead of the deflagration front. The internal fiducials register both internal changes in the plug and changes in the position between successive x-ray images. Tantalum witness strips placed on the inner wall of the explosive channel revealed radial expansion of the tube bore at successive x-ray exposures, indicating the internal pressure of about 100 MPa just before detonation. Images indicate that the deflagration is not only asymmetric but also involves newly observed transient phenomena just before detonation. Furthermore, we typically see a brief but continuous increase in deflagration speed and the formation of a deflagration channel that bypasses the plug just prior to detonation. We hypothesize that these phenomena play an important role in the deflagration-to-detonation transition itself.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

Early-Stage Radiation Safety Analysis for the Spallation Neutron Source Second Target Station Bunker Operations

The Second Target Station project at Oak Ridge National Laboratory will develop a cold neutron source to meet growing experimental needs. This paper describes calculations of the residual dose rates associated with the monolith shield plug and the beamline bunker, two key conventional operations and radiation safety features. While neutron production is active, the instrument hall outside the bunker must be generally accessible with dose rates of less than 0.25 mrem/h. When neutron production is halted, the bunker must be accessible for hands-on maintenance operations. Further, these two requirements form the cause for the assessments reported herein of residual dose rates caused by the monolith shield plug and residual dose rates in the bunker. The monolith shield plug was shown to not produce significant dose rates inside the bunker after a 20-year lifetime, and the residual dose rates inside the bunker for the case of an operating beamline were shown to reasonably allow for hands-on maintenance. These calculations are based on preliminary design models of the relevant systems. Additionally, an example showing the significance of considering neutron supermirror physics in transport calculations that track nuclide production and destruction rates to produce gamma sources for residual dose rate calculations is included. The example shows that if neutron supermirror physics is not considered, dose rate fields may be significantly underpredicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

Investigation of the effects of passive pre-chamber nozzle pattern and ignition system on engine performance and emissions

The impact of passive pre-chamber (PC) internal volume, nozzle hole pattern (i.e. with and without a central axial nozzle), and PC igniter plug type on performance and emissions was investigated in an optically accessible, single-cylinder, gasoline research engine. The two PC igniter plugs investigated were a conventional inductive coil spark plug and a nanosecond repetitively pulsed (NRP) plasma discharge system previously demonstrated to accelerate early flame propagation. The baseline PC design featured a funnel shaped internal volume with a PC tip that contained six radial nozzles and a larger central axial nozzle. Two additional PC tip geometries were evaluated where either the baseline internal volume was increased or the axial nozzle was removed and the radial nozzle diameters were increased. A sweep of charge equivalence ratios ( ϕ) from nearly stoichiometric to the lean limit was performed for a fixed engine speed (1300 revolutions per minute), and engine load (3.5 bar gross indicated mean effective pressure). Time-resolved PC and main chamber (MC) pressure data as well as MC emissions data were collected to analyze engine performance and emissions characteristics. Combustion in the MC was further investigated using high-speed excited methylidyne radical (CH*) chemiluminescence imaging. Collected results highlighted that while all PC tips and ignition systems exhibited similar performance and emissions down to ϕ = 0.8, relevant differences in thermal efficiency and emissions for leaner charge mixtures were observed, with the results highly dependent on the nozzle pattern and ignition system. Major deviations were correlated to preferential de-pressurization of the PC through the axial nozzle for lean conditions that was not observed for mixture conditions closer to stoichiometric. Results show that a combination of radial and axial nozzle patterns in the PC extended lean-stability limits at the low-load condition evaluated. Further benefits were observed with the use of NRP ignition systems due to faster combustion within the PC volume provided that the volume was sufficiently large.

Di Sabatino, Francesco↗

Shielding Analyses for SNS Accelerator Power Upgrade

The Proton Power Upgrade (PPU) project [1] at Spallation Neutron Source (SNS) is aiming at increasing the neutron beam intensities at the First Target Station (FTS) and advancing accelerator capability to additionally power a future Second Target Station (STS) [2]. PPU will involve upgrading the SNS accelerator complex to double the currently available proton beam power from 1.4 to 2.8 MW, by increasing the proton beam energy from 1 GeV to 1.3 GeV and by increasing the proton beam current.PPU will enable new science capabilities enhancing the experiment throughput of the 19 existing FTS instruments, which are heavily oversubscribed. STS will include 22 additional neutron scattering instruments. Numerous neutronics analyses are performed to support PPU evaluating the FTS systems for higher beam power and for system upgrades. Part of the PPU scope is an extension of the Ring to Target Beam Transport (RTBT) line, a stub out of the accelerator tunnel for the future Ring to STS Transport (RTST) line[3]. As the RTST tunnel will not be built within the PPU project, the stub will be shielded by a plug, which is planned to be made from regular concrete.In order to provide radiation protection safety, analyses are required to design adequate plug thickness for the stub. The thickness of the stub is driven by the criterion that the area downstream of the plug is “unrestricted access area”, demanding the dose rate downstream the stub be below 0.25 mrem/h at 30 cm from the surface at normal operation and below 20 Rem/hr for accident cases. Additionally, analyses verifying the amount of soil for shielding the accelerator tunnel to the above stated requirements are performed.

Popova, Irina I.↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 1—Theory

Summary Core-scale measurements are considered the ground truth that oil and gas or electric utility companies use to predict the migration of fluids such as oil, natural gas, carbon dioxide, or brine deep underground during their extraction or injection operations. To provide a greater understanding of petrophysical properties of low-permeability geologic formations such as shales and tight gas sandstones, this study introduces a novel core-analysis procedure. The technique follows conventional pressure-pulse-decay permeametry, where the pressure in an inlet chamber adjacent to a cylindrical core plug undergoes a rapid pressurization, the system is shut in, and the pressure reaches a new equilibrium. However, unlike a standard unidirectional pressure-pulse decay, the full-immersion pressure-pulse decay (Hannon 2019) applies a pressure disturbance to the entire outer surface area of the sample. This article covers the numerical simulator designed to model flow through an anisotropic porous sample in this scenario. The model assumes distinct but uniform permeabilities along the radial and axial directions of the cylindrical plug sample. When extracting a plug vertically (or perpendicular to bedding), the permeability along the radial direction associates with the horizontal permeability (i.e., parallel to bedding), whereas in the axial direction, flow occurs perpendicular to bedding (a vertical permeability). Investigations of these model outputs demonstrate an approximately 20-fold decrease in time to complete a full-immersion experiment compared with conventional pressure-pulse decay. Furthermore, the pressure-decay curves resulting from the full-immersion method have slightly different shapes than those resulting from other unidimensional transient methods. These differences begin to demonstrate that, under achievable experimental conditions, the analysis of pressure data from one full-immersion test could enable the simultaneous estimation of the apparent permeabilities parallel and perpendicular to bedding of a cylindrical sample in addition to its porosity. A follow-up article finalizes the proof of this capability with a parameter-estimation procedure and presents experimental verification through a proof-of-concept study. Described in greater detail in that article, the parameter estimator requires multiple forward simulations to analyze the data, which behooves minimizing the compute time for each simulation. By using an alternating direction implicit time-marching scheme and a structured but variably spaced grid, the numerical simulator built for this purpose provides a forward model output with suitable accuracy in approximately 0.5 seconds.

Energy & Fuels↗

Quantifying the Tangible Value of Public Electric Vehicle Charging Infrastructure

The lack of an extensive public recharging infrastructure is an important barrier to the growth of the plug-in electric vehicle (PEV) market. Because charging infrastructure is likely to be underutilized during the early stages of market development, it is difficult for decision makers to decide how much to invest in public charging stations. Quantifying the value of public charging infrastructure to current and potential future owners of PEVs is essential for estimating the benefits of charging stations to current PEV owners and for predicting the impact on future PEV sales. This paper estimates consumers’ willingness to pay for public charging infrastructure in the context of utility maximization. The objective is to provide a method for valuing charging infrastructure that can inform investment decisions and be used in forecasting models to predict the impacts on future PEV sales. A basic theory of the tangible value of charging infrastructure is developed as a function of PEV type, range, recharging time and existing infrastructure. Existing simulation studies provide functional relationships that quantify the ability of charging infrastructure to enable additional miles of electrified travel. The enabled travel functions are used to predict impact of infrastructure deployment on incremental electrified travel for 1) plug-in hybrids and 2) intra-regional and 3) inter-regional travel by all-electric vehicles. The willingness to pay for increased electrified miles is derived from the willingness to pay for increased electric driving range, based on econometric studies of plug-in vehicle choice. The result is a set of three functions that can be used to calculate the marginal willingness-to-pay for public charging infrastructure as a function of vehicle attributes, existing charging infrastructure, energy prices and annual vehicle travel.

33 ADVANCED PROPULSION SYSTEMS↗

Accidental Disassembly of a Multi Branch Outlet Strip with Surge Protector (Investigation Report)

On December 16 a worker attempted to disconnect a computer plug from a multi outlet surge protector strip. The plastic housing of the surge protector disintegrated while the plug was pulled exposing the bare conductors of the internal wiring. The worker disconnected the wall plug on the multi outlet strip and de-energized the outlet strip. The worker contacted the FOD and the FOD called the ISR DESO for advice. The DESO collected the pieces and performed an autopsy on the device.

42 ENGINEERING↗

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Seal Strength Calculations for Low Mass DDT Vessel

Lawrence Livermore National Laboratory (LLNL) is collaborating with Colorado School of Mines (Mines), to field the first dynamic experiments on the 3-ring flash radiography system (3-ring). One set of experiments for 3-ring concerns the deflagration to detonation transition (DDT), within a sealed column of high-explosives. The high-explosive material is ignited at one end with a BK-80, an igniter made from Boron Potassium-Nitrate (BKNO 3 ). The initial deflagration reaction will increase the pressure in the sealed vessel, resulting in the formation of a dense "plug" of material ahead of the deflagration front. The transition to detonation is thought to be related to the plug formation. Previous experiments have been able to resolve the plug geometry, but only in a two dimensional radio-graph. 3-ring offers a novel diagnostic tool which could provide three dimensional density fields via few-view reconstruction algorithms and computed tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enabling Low-Temperature (LTP) Ignition Technologies for Multi-Mode Engines through the Development of a Validated High-Fidelity LTP Model for Predicative Simulations Tools

The goal of multi-mode engine architectures is to extend current lean-burn dilution limits with renewable fuels, which requires spark plugs to deposit high energies (hundreds of mJ) in order to initiate ignition and complete combustion. At elevated energy deposition rates, spark plugs experience increased electrode erosion and thermal losses, which ultimately shortens the spark-plug lifetime and lowers ignition efficiency. As such, in order to safeguard the efficiency gains of multi-mode concepts, new and improved ignition technologies are required. Recently, non-equilibrium low-temperature plasmas (LTP) have been shown to promote energy-efficient ignition via quenching and transport of electronically excited atoms and molecules, selective radical production and fast heating of hydrocarbon/air mixtures [1-2]. Thus, LTP is seen as a technology that can potentially improve the energy extraction efficiency of fuels, while enabling kinetically controlled combustion modes towards fuel leaner conditions to realize current DOE VTO goals of improving the sustainability of future mobility [3]. Although many previous studies have demonstrated the efficacy of plasma-assisted ignition to enhance combustion, the detailed enhancement mechanisms remain largely unknown, especially for oxygenated fuels and at elevated pressures that are most relevant to practical engine conditions. These barriers hinder the development of accurate and comprehensive numerical models that seek to describe LTP-based ignition in existing engine design software tools and methods. Current state-of-the-art simulation capabilities for LTP ignition systems are in need of improvements since they deliver qualitative results only due to important limitations of existing approaches. Firstly, validated kinetic models with elementary steps for plasma discharges in oxygenated fuel/air mixtures of relevance to the transportation sector are required. Such kinetic models do not exist at present and will be developed and validated within this project. Secondly, plasma discharges and reactive mixture ignition are multi-scale, unsteady processes requiring high-performance numerical methods and software that execute efficiently on DOE supercomputers. Such software does not exist at present and will be developed and applied to practical LTP ignition scenarios as part of this project. Thirdly, experimental databases that are tailored to serve as benchmark in support of the development of predictive computational models of LTP ignition do not exist and will be part of this project.

33 ADVANCED PROPULSION SYSTEMS↗

Numerical and Experimental Study of an Aircraft Igniter Plasma Jet Discharge

The spark discharge of an aircraft plasma jet igniter is studied using high-fidelity numerical simulations and X-ray radiography measurements. The target problem here features the thermal expansion of hot gas introduced by the electric spark within a confined igniter cavity, which eventually evolves into a pulsed jet of a high-temperature kernel. A comprehensive set of models adapted from existing strategies for internal combustion engine spark plug discharge is extended to the target problem, including the modeling of energy deposition, plasma reactions, thermodynamic properties, and heat losses. A series of validation and parameter studies are performed and presented. The kernel size is found to be sensitive to heat losses arising from radiation and hot gas remained within the discharge cavity, rather than heat conduction to the wall in the discharge cavity. Depending on the enforced shape of the post-breakdown electric arc, the spark kernel can be off-centered, tilted, and considerably asymmetric. These features have been previously not considered when studying such igniter configurations and may have a first-order impact on the ignition process. Provided a proper setup of the heat loss models and electric arc shape, the numerical results are quantitatively comparable to the experimental results in terms of the kernel size, shape, and velocity throughout different stages after the spark discharge.

Tang, Yihao↗

Demand-Side Grid (dsgrid) TEMPO Light-Duty Vehicle Charging Profiles v2022

Simulated hourly electric vehicle charging profiles for light-duty household passenger vehicles in the contiguous United States, 2018-2050. Profiles are differentiated by scenario, county, household and vehicle types, and charging type. Data was produced in 2022 using the Transportation Energy & Mobility Pathway Options (TEMPO) model and published in demand-side grid (dsgrid) toolkit format. Data are available for three adoption scenarios: "AEO Reference Case", which is aligned with the U.S. EIA Annual Energy Outlook 2018 (linked below), "EFS High Electrification", which is aligned with the High Electrification scenario of the Electrification Futures Study (linked below), and "All EV Sales by 2035", which assumes that average passenger light-duty EV sales reach 50% in 2030 and 100% in 2035. The charging shapes are derived from two key assumptions of which data users should be aware: "ubiquitous charger access", meaning that drivers of vehicles are assumed to have access to a charger whenever a trip is not in progress, and "immediate charging", meaning that immediately after trip completion, vehicles are plugged in and charge until they are either fully recharged or taken on another trip. These assumptions result in a bounding case in which vehicles' state of charge is maximized at all times. This bounding case would minimize range anxiety, but is unrealistic from the point of view of both electric vehicle service equipment (EVSE) (i.e., charger) access, and plug-in behavior as it can result in dozens of charging sessions per week for battery electric vehicles (BEVs) that in reality are often only plugged in a few times per week.

Array↗