Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Improving Real-world Measurement-based Phase Identification in Power Distribution Feeders with a Novel Reliability Criteria Assessment

This paper is concerned with solving the phase identification problem in a real-world smart grid project; where there is only a few smart meters available on each of the five power distribution feeders in the test site in Riverside, CA. The main idea is to develop and use two reliability criteria that can identify the most reliable components in a broken-down phase identification analysis; thereby significantly improving the accuracy of phase identification. The proposed method consists of three steps. The results from field implementation reveal the accuracy and consistency of the proposed method in practice, in correctly and reliability identifying the phase connectivity.

Phase identification Data-driven method Sliding wi↗

Truncated nonlinear interferometer-based atomic force microscopes

A truncated non-linear interferometer-based atomic force microscope (AFM) includes an input port and a non-linear amplifier that renders a probe beam and a conjugate beam. The AFM includes local oscillators having a relationship with the probe beam and the conjugate beam. The displacement of the AFM's cantilever is transduced by the probe beam, and/or the conjugate beam or their respective local oscillators. The AFM's phase-sensitive detectors detect a phase modulation between the respective local oscillators and the probe beam and the conjugate beam. The detected phase modulation corresponds to the change in phase. The AFM's circuitry measures phase signals that are indicative of the cantilever displacement. The resulting measurement signals exhibit a quantum noise reduction in either the intensity difference or phase sum quadrature.

Pooser, Raphael C.↗

Electronic heterodyne readout of fringes in moire deflectometry

An electronic heterodyne technique is described for the readout of fringes in moire deflectometry. The technique is based on phase measurements of signals generated by a photodetector observing the light transmitted through a traveling moire fringe pattern. The phase of the signal is proportional to the fringe deviation and thus to the deflection angle of the light ray. The phase is measured on line by a standard phase meter with an accuracy of 1 deg or 1:360 of a fringe. The technique, which is precise and sensitive, is demonstrated by detecting and measuring a fringe shift of 0.15 mm corresponding to 0.029 of a fringe.

Stricker, J.↗

Constant-Frequency Pulsed Phase-Locked-Loop Measuring Device

Constant-frequency pulsed phase-locked-loop measuring device is sensitive to small changes in phase velocity and easily automated. Based on use of fixed-frequency oscillator in measuring small changes in ultrasonic phase velocity when sample exposed to such changes in environment as changes in pressure and temperature. Automatically balances electrical phase shifts against acoustical phase shifts to obtain accurate measurements of acoustical phase shifts.

Yost, William T.↗

Automatic Phasing for Active Antenna Elements

Automatic phasing system periodically interrupts antenna operation for calibration intervals and measures phase and amplitude response at each active antenna element. Using these measurements, system adjusts phase shift and possibly gain of active elements during operating intervals to give desired antenna-gain pattern.

Wu, C.↗

CoURAGE Stationary ELF PTR-MS Measurements at the Mt. Airy Site

Gas phase measurements of volatile organic compounds (VOC) taken at the DOE ARM S2 site for the CoURAGE campaign using a Vocus ELF PTR-ToF (Tofwerk) mass spectrometer. Measurements of several VOC's (e.g., acetaldehyde, acetone, benzene, etc.) were obtained at 1-minute resolution from 4/08 to 5/19.

acetaldehyde_concentration↗

A comparative study of solute trapping in Fe-(33–45 at%) Cu alloys manufactured by laser directed energy deposition

The high cooling rates in laser directed energy deposition (DED-LB) of alloys lead to substantial amounts of solute trapping as solute atoms cannot diffuse away from the solid/liquid interface before it advances. In some concentrated alloys, this results in supersaturated solid phases that form nanoscale hierarchical microstructures when the solute atoms precipitate out during reheating from subsequent laser passes. We choose the Iron-Copper (Fe-Cu) binary alloy as model system as it is chemically homogeneous in the liquid phase and has negligible solid solubility at room temperature. Two alloys with nominal compositions in atomic (at.) %, Fe67Cu33 and Fe55Cu45, were manufactured using DED-LB. Scanning transmission electron microscopy (STEM), energy dispersive spectroscopy (EDS) and wavelength dispersive spectroscopy (WDS) were used to characterize the nanostructures and heterogeneous chemical compositions. A non-equilibrium solute partitioning model was used to compute the supersaturated chemistries of the constituent phases and validated with experimentally measured compositions. The measured phase compositions of the two alloys were very similar, at roughly 12 at.% Cu and 4 at.% Fe in the α(bcc)-Fe and ε(fcc)-Cu phases respectively, despite having different processing parameters and mechanical behavior. This indicates that the total thermal history, that depends on both the processing parameters and laser scan pattern, plays a stronger role on the final microstructure evolution than just the initial quantity of trapped solute. In addition, we find that current non-equilibrium solute partitioning models applied on the continuum scale fall short of predicting accurate quantitative phase compositions in concentrated alloys, although the qualitative trends are captured correctly.

36 MATERIALS SCIENCE↗

Studies of multi-baseline spaceborne interferometric synthetic aperture radars

A set of Seasat SAR data that were obtained in nearly repeat ground track orbits is utilized to simulate the performance of spaceborne interferometric synthetic aperture radar (ISAR) systems. A qualitative assessment of the topography measurement capability is presented. A phase measurement error model is described and compared with the data obtained at various baseline separations and signal-to-noise ratios. Finally, the implications of these results on the future spaceborne ISAR design are discussed.

Li, F.↗

Time-Transfer System for Two Orbiting Spacecraft

A report describes the time-transfer system of the Gravity Recovery and Climate Experiment (GRACE), in which information on the distribution of Earth mass is extracted from position and time measurements for two spacecraft about 200 km apart in a circular, nearly polar orbit. Each spacecraft carriers a Global Positioning System (GPS) receiver, a K/Ka-band ranging (KBR) instrument, and an ultra-stable oscillator (USO) that serves as a clock for the GPS and KBR units. The long-term errors of the USOs are cancelled by use of a technique, called dual-one-way phase measurements, in which the phases of the KBR signals from spacecraft A as measured at spacecraft B are added to the phases of the KBR signals from spacecraft B as measured at spacecraft A. GPS data are used to synchronize time between the USOs to within approximately 150 ps as needed to enable the dual-one-way phase measurements: For each spacecraft, the GPS data are used to solve for orbital positions, and the difference between the onboard clocks and a ground clock every 5 minutes. The relative clock rate between the spacecraft is then determined from the difference between the two solutions.

Bertiger, William↗

The 1996 Subsonic Aircraft: Contrail and Cloud Effects Special Study

During April 1996 NASA, in conjunction with the DOE, will sponsor a multi-aircraft field campaign to better understand the microphysical and radiative properties of cirrus clouds, the origins of ice nuclei and cloud condensation nuclei in the upper troposphere, and the possible role that the commercial subsonic aircraft fleet might play in altering cloud or aerosol properties. The NASA ER-2 aircraft will be used as a remote sensing platform, while the NASA DC-8 aircraft will be used as an in situ measurement platform. In situ observations will include a full set of size distribution measurements from nano-meter to millimeter sizes, ice water content measurements, gas phase and condensed phase chemical measurements, ice crystal optical phase function measurements, lidar observations of cloud top and cloud base, and atmospheric state measurement. The ER-2 will have lidar, microwave ice water path measurements, as well as visible and infrared spectral measurement. In this presentation the highlights of the mission will be presented. The goal will be to address fundamental questions such as the mode of nucleation of cirrus clouds, the composition of the nuclei on which cirrus form, the degree to which aircraft impact cirrus cloud properties.

Toon, Owen B.↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Phasor algorithms of the SIM fringe estimation

The Space Interferometry Mission (SIM) will provide unprecedented micro-arcsecond (pas) precision to search for extra-solar planets and possible life in the universe. SIM will also revolutionize our understanding of the dynamics and evolutions of the local universe through hundred-fold improvements of inertial astrometry measurements. SIM has two so-called guide interferometers to provide stable inertial orientation knowledge of the baseline, and a science interferometer to measure target fringes. The guide and science measurements are based on the fringe phase measurements using a CCD detector. One of the key issues with SIM is to develop a new algorithm for calculation of fringe parameters. Not only astrometric results need that new algorithm, but also real-time fringe tracking requires a new method to calculate phase and visibility fast and accurately. The formulas for the phasor algorithms for fringe estimation are presented. The signal-noise ratio performances of the fringe quadratures are demonstrated. The advantages of phasor algorithms for application of fast fringe tracking and on-board data compression are discussed.

interferometry↗

Digital Phase-Locked Loop With Phase And Frequency Feedback

Advanced design for digital phase-lock loop (DPLL) allows loop gains higher than those used in other designs. Divided into two major components: counterrotation processor and tracking processor. Notable features include use of both phase and rate-of-change-of-phase feedback instead of frequency feedback alone, normalized sine phase extractor, improved method for extracting measured phase, and improved method for "compressing" output rate.

Thomas, J. Brooks↗

Toward Relating Open- and Closed-Test Section Microphone Phased Array Aeroacoustic Measurements

Aeroacoustic measurements utilizing microphone phased arrays are becoming more commonplace in large-scale wind tunnels. However, for such costly tests it is difficult to assess the influence of a given facility's configuration on the acquired data. One such opportunity has recently arisen in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel, where the High-Lift configuration of the Common Research Model was tested in both open-jet and closed wall configurations. Acoustic data were acquired on the same model with the same specific hardware at the same Mach number; and for similar model angles of attack, array apertures, and array angles relative to the model location. Initial deconvolution comparisons using DAMAS appear poor. The closed test section results show contamination likely due to background noise and reflections. The open-jet results show severe blurring due to the decorrelation of acoustic waves passing through a turbulent free shear layer. However, accounting for image sources in the DAMAS grid reduces visual artifacts in the closed test section results, and a preliminary coherence correction technique mitigates the blurring in the open-jet results. Qualitatively, both tests identify similar source behavior. Quantitatively, summed spectra of the slat noise agree in some frequency bands but differ in others. Proposals that may mitigate the difference are given for each configuration, such as correcting for the array protective cover and applying background subtraction in the closed wall configuration, and further developing the coherence loss correction for deconvolution methods in the open-jet setup.

microphone array↗

Evaluation of the Change in Uranium Mobility in Sediments from the Hanford 300-FF-5 Stage B Polyphosphate Field Injection

The purpose of this study was to evaluate the change in uranium mobility in the periodically re-wetted zone (PRZ) and upper unconfined aquifer of the Hanford Site’s 300-FF-5 operable unit as a result of Stage B polyphosphate (PO 4 ) injections. These 300 Area sediments are beneath or near the former North Process Pond, which has previously been shown to contain metatorbernite [Cu(UO 2 ) 2 (PO 4 ) 2 •8H 2 O] and uranophane [Ca(UO 2 ) 2 (SiO 3 OH) 2 •5H 2 O], along with aqueous and adsorbed uranium (U), and small amounts of U in calcite as a result of acidic disposal with a significant number of co-contaminants. Previous laboratory-scale studies have identified multiple mechanisms that decrease uranium mobility with polyphosphate injection: (a) precipitation of a low-solubility uranium-phosphate mineral (autunite); (b) precipitation of a Ca-phosphate solid that incorporates U; (c) precipitation of Ca-phosphate mineral (apatite group minerals) that coats existing uranium phases (i.e., U in calcite, U in Fe-oxides), reducing uranium leaching; and (d) aqueous Ca-U-carbonate species adsorption onto apatite. Given the significant amount of apatite precipitation, other U phases such as carbonates could also coprecipitate with apatite. To quantify differences in solubility, leachability, and phases of uranium between pre- and post-PO 4 -treated sediments, different types of analyses were conducted, including analysis of uranium in (a) a carbonate solution extraction from sediment over 1000 h (41.67 days), (b) six sequential liquid extractions from sediment over approximately 1 week, (c) leaching of uranium from sediments in one dimensional (1-D) column experiments over 2 months, and (d) solid phase characterization of select sediments. An additional extraction and solid phase measurements were conducted to evaluate phosphate precipitate formation. Metals were also analyzed in sequential liquid extractions as indicators of (a) amendment injection delivery, (b) co-contaminant movement, and (c) changes in solid phases. Aqueous and solid phase carbonate measurements were also conducted to evaluate changes in carbonates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗