Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Calibration and Performance Measurements for the NASA Deep Space Network Aperture Enhancement Project (DAEP)

The NASA Deep Space Network (DSN) has recently constructed two new 34-meter antennas at the Canberra Deep Space Communications Complex (CDSCC). These new antennas are part of the larger DAEP project to add six new 34-meter antennas to the DSN, including two in Madrid, three in Canberra and one in Goldstone (California). The DAEP project included development and implementation of several new technologies for the S, X, Ka (26 GHz) and Ka (32 GHz) -band uplink and downlink electronics, as previously reported. The electronics upgrades were driven by several different considerations, including parts obsolescence, cost reduction, improved reliability and maintainability, and capability to meet future performance requirements. The new antennas are required to support TT&C links for all of the NASA deep-space spacecraft, as well as for several international partners. Some of these missions, such as Voyager 1 and 2, have very limited link budgets, which results in demanding requirements for system G/T performance. These antennas are also required to support radio science missions with several spacecraft, which dictate some demanding requirements for spectral purity, amplitude stability and phase stability for both the uplink and downlink electronics. After completion of these upgrades, a comprehensive campaign of tests and measurements took place to characterize the electronics and calibrate the antennas. Radiometric measurement techniques were applied to characterize, calibrate, and optimize the performance of the antenna parameters. These included optical and RF high-resolution holographic and total power radiometry techniques. These techniques, which are described in the article, resulted in the highest antenna aperture efficiency in the DSN, of 66% achieved, at the highest operating frequency of the antenna, which is Ka-Band (32-GHz). The other measurements and results described include antenna noise temperature, photogrammetry and holography alignment of antenna panels, beam-waveguide mirrors, and subreflector, antenna aperture efficiencies and G/T versus frequency, and antenna pointing models. The first antenna (DSS-35) was entered into operations in October, 2014 and the 2nd antenna (DSS-36) in October, 2016. This paper describes the measurement techniques and results of the testing and calibration for both antennas, along with the driving requirements.

Rochblatt, David J.↗

Assessment of dedicated low-dose cardiac micro-CT reconstruction algorithms using the left ventricular volume of small rodents as a performance measure

Purpose: Phase-correlated microcomputed tomography (micro-CT) imaging plays an important role in the assessment of mouse models of cardiovascular diseases and the determination of functional parameters as the left ventricular volume. As the current gold standard, the phase-correlated Feldkamp reconstruction (PCF), shows poor performance in case of low dose scans, more sophisticated reconstruction algorithms have been proposed to enable low-dose imaging. In this study, the authors focus on the McKinnon-Bates (MKB) algorithm, the low dose phase-correlated (LDPC) reconstruction, and the high-dimensional total variation minimization reconstruction (HDTV) and investigate their potential to accurately determine the left ventricular volume at different dose levels from 50 to 500 mGy. The results were verified in phantom studies of a five-dimensional (5D) mathematical mouse phantom. Methods: Micro-CT data of eight mice, each administered with an x-ray dose of 500 mGy, were acquired, retrospectively gated for cardiac and respiratory motion and reconstructed using PCF, MKB, LDPC, and HDTV. Dose levels down to 50 mGy were simulated by using only a fraction of the projections. Contrast-to-noise ratio (CNR) was evaluated as a measure of image quality. Left ventricular volume was determined using different segmentation algorithms (Otsu, level sets, region growing). Forward projections of the 5D mouse phantom were performed to simulate a micro-CT scan. The simulated data were processed the same way as the real mouse data sets. Results: Compared to the conventional PCF reconstruction, the MKB, LDPC, and HDTV algorithm yield images of increased quality in terms of CNR. While the MKB reconstruction only provides small improvements, a significant increase of the CNR is observed in LDPC and HDTV reconstructions. The phantom studies demonstrate that left ventricular volumes can be determined accurately at 500 mGy. For lower dose levels which were simulated for real mouse data sets, the HDTV algorithm shows the best performance. At 50 mGy, the deviation from the reference obtained at 500 mGy were less than 4%. Also the LDPC algorithm provides reasonable results with deviation less than 10% at 50 mGy while PCF and MKB reconstruction show larger deviations even at higher dose levels. Conclusions: LDPC and HDTV increase CNR and allow for quantitative evaluations even at dose levels as low as 50 mGy. The left ventricular volumes exemplarily illustrate that cardiac parameters can be accurately estimated at lowest dose levels if sophisticated algorithms are used. This allows to reduce dose by a factor of 10 compared to today's gold standard and opens new options for longitudinal studies of the heart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of modeled and measured performance of a GSO crystal as gamma detector

We have modeled, tested, and installed a large, cerium-activated Gd{sub 2}SiO{sub 5} crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.

Geant4 Gamma detection↗

Performance Measurement of Advanced Stirling Convertors (ASC-E3)

NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing data of the Advanced Stirling Convertor (ASC). The latest version of the ASC (ASC-E3, to represent the third cycle of engineering model test hardware) is of a design identical to the forthcoming flight convertors. For this generation of hardware, a joint Sunpower and GRC effort was initiated to improve and standardize the test support hardware. After this effort was completed, the first pair of ASC-E3 units was produced by Sunpower and then delivered to GRC in December 2012. GRC has begun operation of these units. This process included performance verification, which examined the data from various tests to validate the convertor performance to the product specification. Other tests included detailed performance mapping that encompassed the wide range of operating conditions that will exist during a mission. These convertors were then transferred to Lockheed Martin for controller checkout testing. The results of this latest convertor performance verification activity are summarized here.

Stirling Cycle↗

Meta-Level Design Guidance and Operator Performance Measures for Hybrid Control Rooms

The purpose of this grant was to refine and test methods to evaluate digital human system interfaces (HSI) for existing largely analog nuclear power plant (NPP) control rooms (CRs). We hypothesized that CR operator performance (CROP) in hybrid NPP CRs will be improved if future digital HSI is designed based on: 1) more robust design guidelines for operator situation awareness (SA) and decision-making (DM); 2) enhanced CROP metrics during HSI evaluation; 3) an ontology for selecting simulation scenarios to evaluate digital HSI; and 4) a model to predict optimal HSI design attributes given CROP objectives. The team conducted numerous nuclear power plant site visits (e.g., to Brown’s Ferry, Palo Verde, Sequoyah and Vogtle) to study control room operations and crisis management and 3 visits to the NRC Chattanooga Training Center. We observed research studies at DC Cook and NRC Chattanooga in collaboration with the Halden Reactor Project. We collected operator performance and workload data in one NPP simulator. A comprehensive human (i.e., CROP) performance literature review was published in Applied Ergonomics. We obtained operator team performance data from CAER to produce our data fusion model and a paper delineating the results have been accepted (revision submitted) in Resilience Engineering and System Safety. We analyzed interview data related to scenario ontology development; a manuscript is still in preparation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MIR Solar Array Return Experiment: Power Performance Measurements and Molecular Contamination Analysis Results

A solar array segment was recently removed from the Mir core module and returned for ground-based analysis. The segment, which is similar to the ones the Russians have provided for the FGB and Service Modules, was microscopically examined and disassembled by US and Russian science teams. Laboratory analyses have shown the segment to he heavily contaminated by an organic silicone coating, which was converted to an organic silicate film by reactions with atomic oxygen within the. orbital flight environment. The source of the contaminant was a silicone polymer used by the Russians as an adhesive and bonding agent during segment construction. During its life cycle, the array experienced a reduction in power performance from approx. 12%, when it was new and first deployed, to approx. 5%, when it was taken out of service. However, current-voltage measurements of three contaminated cells and three pristine, Russian standard cells have shown that very little degradation in solar array performance was due to the silicate contaminants on the solar cell surfaces. The primary sources of performance degradation is attributed to "thermal hot-spotting" or electrical arcing; orbital debris and micrometeoroid impacts; and possibly to the degradation of the solar cells and interconnects caused by radiation damage from high energy protons and electrons.

Visentine, James↗

False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

09 BIOMASS FUELS↗

Aerodynamic and Performance Measurements on a SWT-2.3-101 Wind Turbine

This paper provides an overview of a detailed wind turbine field experiment being conducted at NREL under U.S. Department of Energy sponsorship. The purpose of the experiment is to obtain knowledge about the aerodynamics, performance, noise emission and structural characteristics of the Siemens SWT-2.3-101 wind turbine.

17 WIND ENERGY↗

Portals 4 network API definition and performance measurement

Portals is a low-level network programming interface for distributed memory massively parallel computing systems designed by Sandia, UNM, and Intel. Portals has been designed to provide high message rates and to provide the flexibility to support a variety of higher-level communication paradigms. This project developed and analyzed an implementation of Portals using shared memory in order to measure and understand the impact of using general-purpose compute cores to handle network protocol processing functions. The goal of this study was to evaluate an approach to high-performance networking software design and hardware support that would enable important DOE modeling and simulation applications to perform well and to provide valuable input to Intel so they can make informed decisions about future network software and hardware products that impact DOE applications.

99 GENERAL AND MISCELLANEOUS↗

Surface Strength of Silicon Nitride in Relation to Rolling Contact Performance Measured on Ball-on-Rod and Modified Four-Ball Tests

Silicon nitride (Si{sub 3}N{sub 4}) has been used in various rolling contact applications in turbomachinery, automotive and power industry. It is favoured to replace conventional steel due to its low density, low friction, corrosion resistance and good performance under extreme condition. However, a major limitation of its wider application is its high material and machining cost, especially the cost associated with the finishing process. In the present study, a low cost sintered and reaction bonded silicon nitride (SRBSN) is used to study the surface machining effects on its rolling contact performance. Attempt has been made to link the surface strengths of Si{sub 3}N{sub 4} derived from half-rod and C-sphere flexure strength specimens to the rolling contact lifetimes of Si{sub 3}N{sub 4} rod and ball specimens. The rolling contact fatigue tests are carried out on ball-on-rod and modified four ball machines. Three types of surfaces with coarse, fine and conventional finishing conditions are examined. Flexure strength tests on half-rod and C-sphere show an increasing surface strength from specimens with coarse, fine to conventionally machined conditions. During rolling contact fatigue test of as-machined specimens, there are no failures observed on both ball-on-rod and four ball tests after 100 million stress cycles. However, there is a trend of decreasing wear volumes measured on the contact path of rods and balls with coarse, fine and conventional conditions. In four ball test, spall failures are observed on pre-crack specimens. There is a trend of increasing rolling contact fatigue lifetime from pre-cracked specimens with coarse, fine to conventional machining conditions.

36 MATERIALS SCIENCE↗

Performance Measurement of a Multi-Level/Analog Ferroelectric Memory Device Design

Increasing the memory density and utilizing the unique characteristics of ferroelectric devices is important in making ferroelectric memory devices more desirable to the consumer. This paper describes the characterization of a design that allows multiple levels to be stored in a ferroelectric based memory cell. It can be used to store multiple bits or analog values in a high speed nonvolatile memory. The design utilizes the hysteresis characteristic of ferroelectric transistors to store an analog value in the memory cell. The design also compensates for the decay of the polarization of the ferroelectric material over time. This is done by utilizing a pair of ferroelectric transistors to store the data. One transistor is used a reference to determinethe amount of decay that has occurred since the pair was programmed. The second transistor stores the analog value as a polarization value between zero and saturated. The design allows digital data to be stored as multiple bits in each memory cell. The number of bits per cell that can be stored will vary with the decay rate of the ferroelectric transistors and the repeatability of polarization between transistors. This paper presents measurements of an actual prototype memory cell. This prototype is not a complete implementation of a device, but instead, a prototype of the storage and retrieval portion of an actual device. The performance of this prototype is presented with the projected performance of the overall device. This memory design will be useful because it allows higher memory density, compensates for the environmental and ferroelectric aging processes, allows analog values to be directly stored in memory, compensates for the thermal and radiation environments associated with space operations, and relies only on existing technologies.

MacLeod, Todd C.↗

Observations on Cost Modeling and Performance Measurement of Long Term Archives

This paper describes a prototype suite of Excel-based tools that could be used for estimating lifecycle costs for newly planned or modified long-term archival facilities. These tools may also prove valuable for monitoring the long-term performance of such facilities once operational. Cost estimation is by analogy, using statistical curve-fitting techniques across a database of comparable data activities. The database currently includes 29 operational data centers ranging from small (2 FTEs) to large (66 FTEs), and is readily expandable to include additional activities specifically involving data preservation and added value. Each comparable data center is described in terms of its staffing, throughput workload, archival and distribution requirements, levels of user service, overall complexity, degree of automation, and other data, comprising 94 distinct descriptors in all. The descriptors were developed by normalizing heterogeneous data from the various centers and mapping them into an Excel framework consistent with the OAIS reference model. A user-friendly tool is provided for generating input to and updating the comparables database. This tool can also be used to benchmark the performance (in terms of cost versus throughput) of an operational data center, and to update the staffing, cost and workload data on a periodic basis. The comparables database could thus provide a history of staffing and throughput over time, as a means of performance monitoring and providing feedback for continuous improvement. Ancillary tools are also provided for performing "what-if' cost exercises for planning purposes, and for graphical display of data and results. We provide a high-level description of the tools; present our experiences and observations on gathering the information and maintaining the database; and discuss how this tool set might be applied to long term archives.

Fontaine, Kathy↗

BeeSwarm: Enabling Parallel Scaling Performance Measurement in Continuous Integration for HPC Applications

Testing is one of the most important steps in software development–it ensures the quality of software. Continuous Integration (CI) is a widely used testing standard that can report software quality to the developer in a timely manner during development progress. Performance, especially scalability, is another key factor for High Performance Computing (HPC) applications. There are many existing profiling and performance tools for HPC applications, but none of these are integrated into CI tools. In this work, we propose BeeSwarm, an HPC container based parallel scaling performance system that can be easily applied to the current CI test environments. BeeSwarm is mainly designed for HPC application developers who need to monitor how their applications can scale on different compute resources. We demonstrate BeeSwarm using a multi-physics HPC application with Travis CI, GitLab CI and GitHub Actions while using ChameleonCloud and Google Compute Engine as the compute backends. Finally, our results show that BeeSwarm can be used for scalability and performance testing of HPC applications.

97 MATHEMATICS AND COMPUTING↗

Measured performance of the half-scale accurate antenna reflector

A corrugated horn was designed and fabricated for use as a feed for the half-scale accurate antenna reflector. This feed allows the reflector to be used in a compact range configuration as part of a microwave reflectance measuring system. The horn design is described, and the measured farfield patterns of the horn are presented. The horn was installed at the focus of the reflector, and the nearfield of the antenna was measured. The results of these measurements are presented and discussed with respect to the compact range application.

Lambert, Kevin M.↗

Tutorial: Clock and Clock Systems Performance Measures

This tutorial contains basic material - familiar to many. This will be used as a foundation upon which we will build - bringing forth some new material and equations that have been developed especially for this tutorial. These will provide increased understanding toward parameter estimation of clock and clock system's performance. There is a very important International Telecommunications Union (ITU) handbook being prepared at this time which goes much further than this tutorial has time to do. I highly recommend it as an excellent resource document. The final draft is just now being completed, and it should be ready late in 1996. It is an outstanding handbook; Dr. Sydnor proposed to the ITU-R several years ago, and is the editor with my assistance. We have some of the best contributors in the community from around the world who have written the ten chapters in this handbook. The title of the handbook is 'Selection and use of Precise Frequency and Time Systems'. It will be available from the ITU secretariat in Geneva, Switzerland, but NAVTEC Seminars also plans to be a distributor.

Allan, David W.↗

Data Processing and Analysis of Performance Measurements From Ingenuity Rotors in the Jet Propulsion Laboratory 25-Ft Space Simulator

The success of Ingenuity completing over 71 flights on Mars has resulted in the possible use of two further optimized Ingenuity-sized helicopters to retrieve samples for the planned Mars Sample Return campaign. Data to validate performance for several rotor speeds, densities, configurations, and collectives will aid in the design process and help in understanding Ingenuity’s current performance limitations. Tests were performed at the Jet Propulsion Laboratory (JPL) in the 25-foot Space Simulator, which include the Engineering Design Model 1 (EDM-1) with and without a cruciform box, and the Transonic Rotor Test (TRT) which is a single rotor setup featuring the same blade geometry as EDM-1 but designed to spin at much higher RPMs. The experimental setup, test matrix, data processing, data quality, and the performance results for EDM1 and TRT campaigns are presented.

Processing↗