Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A hybrid numerical and machine learning framework for evaluating the performance of a 780 cm 2 aqueous organic redox flow battery

Aqueous organic redox flow battery (AORFB) is a promising cost-competitive technology for large-scale energy storage. Among existing work, the dihydroxyphenazine (DHP)-based AORFB has demonstrated high energy density and low capacity degradation in 10 cm2 cells during lab tests. However, its commercial-scale performance in more complex environments remains unknown, posing a barrier for commercialization. To address this gap, this work presents a comprehensive performance evaluation of a 780 cm 2 DHP-based AORFB by combining physics-based numerical model, machine learning (ML)-based surrogate models, and ML-derived sensitivity quantification. Specifically, we first select 12 key battery parameters that include 10 physicochemical quantities and 2 operation quantities, then select 6 performance metrics that include energy efficiency (EE), discharging capacity, charging energy, and power losses due to concentration, activation, and ohmic over-potentials. With such selection, 12800 combinations of the 12 parameters are subsequently generated using the Latin Hypercube Sampling method. These combinations, together with 38 pre-defined State of Charge, are then integrated to a validated AORFB model developed in COMSOL to compute the performance metrics. With both input parameters and performance metrics, 60 deep neural network (DNN) surrogate models are then trained to approximate the relationship between the 10 physicochemical quantities and 6 performance metrics at each flow rate and current density. Sensitivity scores are then calculated based on the DNN models. Two additional sensitivity analysis tools, i.e., MARS, and SHAP, are also used to cross-validate the sensitivity scores from the DNN. The results demonstrate that 1) the standard potential ranks the first in controlling EE and charging energy, 2) the membrane conductivity is most critical for power loss and EE, and 3) specific area and reaction rate control activation power loss.

25 ENERGY STORAGE↗

Evaluation of Converter Performance Considering Static and Dynamic Device Part-to-Part Variability

This paper presents a methodology to incorporate and analyze the impact of semiconductor device part-to-part variation on power converter performance. By integrating extensive static and dynamic device characterization data with an automated compact model generation process that reflects manufacturing variability, device models with inherent variability features are utilized in converter simulations for a comprehensive assessment of performance impacts. The traditional converter performance evaluation process typically yields fixed efficiency values, often dismissing the inherent part-to-part variability caused by the manufacturing process of semiconductor devices. To address this limitation, a large population of devices was characterized to capture variations in static parameters-such as transfer, output, and capacitance characteristics-as well as dynamic behaviors, including switching losses. This data-driven approach enables the development of individual compact models, which were then integrated into converter simulations to evaluate efficiency ranges rather than single point estimated values. The converter simulation results show that part-to-part component variation can lead to significant efficiency deviations, exceeding several percentage points in high-power conversion applications. By offering a more accurate representation of converter behavior under real-world manufacturing conditions, this methodology enables designers to anticipate performance variability, improving the robustness of power converter designs.

device characterization↗

Performance Portability Evaluation of Fluid-Structure Interaction Simulations on Heterogeneous Platforms

The rapid proliferation of heterogeneous programming languages and multi-vendor hardware has underscored the critical need to evaluate the performance portability of scientific applications. In this work, we present the systematic porting and optimization of a massively parallel fluid-structure interaction code across multiple heterogeneous programming frameworks for deployment on leadership-class supercomputers from major vendors. Our analysis focuses on at-scale performance for simulations involving hundreds of millions of deformable cells, executed on a combination of CPUs and GPUs spanning thousands of nodes on exascale machines. We benchmark the performance of each implementation, highlighting the trade-offs inherent in adopting diverse programming models. Key insights regarding the portability of CUDA on multi-vendor platforms, the superior multi-core CPU performance from SYCL, and architectural considerations on performance optimization are distilled from our experience, offering guidance to other users of high performance computing based on our findings.

Martin, Aristotle [Duke University]↗

What you get is not always what you see—pitfalls in solar array assessment using overhead imagery

Effective integration planning for small, distributed solar photovoltaic (PV) arrays into electric power grids requires access to high quality data: the location and power capacity of individual solar PV arrays. Unfortunately, national databases of small-scale solar PV do not exist; those that do are limited in their spatial resolution, typically aggregated up to state or national levels. While several promising approaches for solar PV detection have been published, strategies for evaluating the performance of these models are often highly heterogeneous from study to study. The resulting comparison of these methods for practical applications for energy assessments becomes challenging and may imply that the reported performance evaluations overly optimistic. The heterogeneity comes in many forms, each of which we explore in this work: the degree of diversity of the locations and sensors (e.g. different satellites, aerial photography) from which the training and validation data originate, the validation of ground truth (manual annotation of imagery vs known solar PV locations), the level of spatial aggregation (e.g. array-level vs regional estimates), and inconsistencies in the training and validation datasets (e.g. different datasets are used for each study and those data are not always made accessible). For each, we discuss emerging practices from the literature to address them or suggest directions of future research. As part of our investigation, we evaluate solar PV identification performance in two large regions: the entire state of Connecticut and the city of San Diego, CA. In Connecticut, we also use 33,114 known parcel-level solar PV installations from Berkeley Lab’s Tracking the Sun dataset to evaluate parcel-level performance and evaluate capacity estimates using 169 municipalities. We also make our code (which we call SolarMapper), pre-trained models, training data, and predictions publicly available and provide a web portal for interactively inspecting each prediction that was made. Here our findings suggest that traditional performance evaluation of the automated identification of solar PV from satellite imagery may be optimistic due to common limitations in the validation process. The takeaways from this work are intended to inform and catalyze the large-scale practical application of automated solar PV assessment techniques by energy researchers and professionals.

14 SOLAR ENERGY↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS

Integrate a combined Structures of Lossless Ion Manipulations (SLIM) module that incorporates both constant (not time-varying) field (CF) and oscillatory (time-varying) field (OF) IM separation stages into an Agilent 6560 IM-QTOF mass spectrometer system. Once the SLIM module has been integrated into the Agilent system, its performance will be evaluated using a variety of different samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-based HPC accelerators: An evaluation on performance and energy efficiency

Hardware specialization is a promising direction for the future of digital computing. Reconfigurable technologies enable hardware specialization with modest non-recurring engineering cost, but their performance and energy efficiency compared to state-of-the-art processor architectures remain an open question. In this article, we use FPGAs to evaluate the benefits of building specialized hardware for numerical kernels found in scientific applications. In order to properly evaluate performance, we not only compare Intel Arria 10 and Xilinx U280 performance against Intel Xeon, Intel Xeon Phi, and NVIDIA V100 GPUs, but we also extend the Empirical Roofline Toolkit (ERT) to FPGAs in order to assess our results in terms of the Roofline model. We show design optimization and tuning techniques for peak FPGA performance at reasonable hardware usage and power consumption. As FPGA peak performance is known to be far less than that of a GPU, we also benchmark the energy efficiency of each platform for the scientific kernels comparing against microbenchmark and technological limits. Results show that while FPGAs struggle to compete in absolute terms with GPUs on memory- and compute-intensive kernels, they require far less power and can deliver nearly the same energy efficiency.

97 MATHEMATICS AND COMPUTING↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Method of Test for Evaluating Building Performance Simulation Software

ANSI/ASHRAE Standard 140 Method of Test for Evaluating Building Performance Simulation Software specifies the method to test the core competency of building performance simulation (BPS) software, a broad class of software which includes building energy modeling (BEM) software. Standard 140 has been widely used by BEM software vendors to help diagnose and compare the results from the program with other modeling programs. The Standard is also referenced by codes, standards, government programs, and other incentive programs as a part of minimum requirements for qualifying BEM software. The explanatory information, summary tables and figures in this 140 User’s Manual (referred to as “this Manual”) are provided to help users in implementing various suites of tests specified in Standard 140-2023 (referred to in this manual as “Standard 140” or “the Standard”).

97 MATHEMATICS AND COMPUTING↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NuQKD: A Modular Quantum Key Distribution Simulation Framework for Engineering Applications

Abstract An experimental Quantum Key Distribution (QKD) implementation requires advanced costly hardware, unavailable in most research environments, making protocol testing and performance evaluation complicated. This has been a major motivation for the development of QKD simulation frameworks, to allow researchers to obtain insight before proceeding into practical implementations. Several simulators have been introduced over the recent years. However, only four are publicly available, only one of which models equipment imperfections. Currently, no open‐source simulator includes all following capabilities: channel attenuation modelling, equipment imperfections and effects on key rates, estimation of elapsed time during classical and quantum‐ channel processes, use of truly random binary sequences for qubits and measurement bases, shared ‐bit fraction customization. In this paper, we present NuQKD, an open‐ source modular, intuitive simulator, featuring all the above capabilities. NuQKD establishes communication between two computer terminals, accepts custom user inputs (iterations, raw key size, attacker interception rate etc.) and evaluates the sifted key, Quantum Bit Error Rate (QBER), elapsed communication time, and more. NuQKD capabilities include optical fiber and free ‐space simulation, modeling of equipment/channel imperfections, bitstrings from True Random Number Generators, decoy‐state protocol support, and automated evaluation of performance metrics. We expect NuQKD to enable convenient and accurate representation of actual experimental conditions.

Gkouliaras, Konstantinos↗

A dynamic 2D Borehole Thermal Energy Storage (BTES) model for enhanced computational efficiency

Progressing toward a future increasingly reliant on renewable energy sources, the development of effective, durable energy storage solutions becomes essential to balance supply and demand fluctuations. Borehole Thermal Energy Storage (BTES) is a long-duration thermal energy storage technology that captures excess heat generated from renewable energy sources and stores it underground for later use, enabling the efficient utilization of sustainable energy. This approach is particularly valuable in district energy networks when integrated with Ground Source Heat Pumps (GSHP) to provide stable heating and cooling. However, traditional three-dimensional (3D) numerical models of BTES systems demand extensive computational resources, limiting their practicality for real-time and large-scale applications. This study introduces a novel two-dimensional (2D) modeling approach that reduces computational costs while maintaining high accuracy. By employing a radial ring-based discretization method, the model simulates heat injection, retention, and retrieval dynamics over seasonal cycles. A new thermal-mass weighted-average temperature parameter is introduced to evaluate the performance of BTES systems. Model validation against FEFLOW simulations demonstrates a 17-fold improvement in computational speed compared to traditional Computational Fluid Dynamics (CFD) models while achieving a mean absolute percentage error (MAPE) of 2 % during charging and 4 % during discharging. Additionally, a trade-off analysis between computational efficiency and accuracy is conducted, ensuring the model's applicability for real-world scenarios. The findings of this research contribute to the development of computationally efficient BTES models, facilitating better optimization, control, and integration into renewable energy systems. This work provides a foundation for further studies in techno-economic analysis, multi-year performance evaluation, and real-time operational strategies for BTES applications, supporting a more sustainable energy future.

2D modeling↗

How May the Choice of Downscaling Techniques and Meteorological Reference Observations Affect Future Hydroclimate Projections?

Abstract We present an intercomparison of a suite of high‐resolution downscaled climate projections based on a six‐member General Circulation Model (GCM) ensemble from Coupled Models Intercomparison Project (CMIP6). The CMIP6 GCMs have been downscaled using dynamical and statistical downscaling techniques based on two meteorological reference observations over the conterminous United States. We use the regional climate model, RegCM4, for dynamical downscaling, double bias correction constructed analogs method for statistical downscaling, and Daymet and Livneh datasets as the reference observations for statistical training and bias‐correction. We evaluate the performances of downscaled data in both historical and future periods under the SSP585 scenario. While dynamical downscaling improves the simulation of some performance evaluation indices, it adds an extra bias in others, highlighting the need for statistical correction before its use in impact assessments. Downscaled datasets after bias‐correction compare exceptionally well with observations. However, the choice of downscaling techniques and the underlying reference observations influence the hydroclimate characteristics of downscaled data. For instance, the statistical downscaling generally preserves the GCMs climate change signal but overestimates the frequency of hot extremes. Similarly, simulated future changes are sensitive to the choice of reference observations, particularly for precipitation extremes that exhibit a higher projected increase in the ensembles trained and/or corrected by Daymet than Livneh. Overall, these results demonstrate that multiple factors, including downscaling techniques and reference observations, can substantially influence the outcome of downscaled climate projections and stress the need for a comprehensive understanding of such method‐based uncertainties.

54 ENVIRONMENTAL SCIENCES↗

Cyber-Power Co-Simulation for End-to-End Synchrophasor Network Analysis and Applications

The resiliency, reliability and security of the next generation cyber-power smart grid depend upon efficiently leveraging advanced communication and computing technologies. Also, developing real-time data-driven applications is critical to enable wide-area monitoring and control of the cyber-power grid given high-resolution data from Phasor Measurement Units (PMUs). North American Synchrophasor Initiative Network (NASPlnet) provides guidance for PMU data exchanges. With the advancement in networking and grid operation, it is necessary to evaluate the performance of different data flow architectures suggested by NASPInet and analyze the impact on applications. Therefore, we need a cyber-power co-simulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents an end-to-end automated and user-driven cyber-power co-simulation using NS3 to model communication networks, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application utilizing PMU data in an IEEE 39 bus test system is presented using this cosimulation testbed.

Mustafa, Hussain M.↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2018

This report presents an enhanced performance evaluation of emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES) data from 1998 through 2018 and (2) maintenance unavailability (UA) performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2018. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: sub-component, failure cause, detection method, recovery, manufacturer, and EDG rating. A statistically significant increasing trend was identified in the frequency of FTLR demands for emergency power system (EPS) and high pressure core spray (HPCS) EDGs and a statistically significant decreasing trend was identified in the frequency of run > 1H hours for EPS and HPCS EDGs.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2020

This report presents an enhanced performance evaluation of emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2020 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2020. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • HPCS EDG FTS failure probability • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTS failure probability • EPS EDG FTLR failure probability • EPS EDG unavailability • EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2022

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2022 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2022. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: (1) HPCS EDG FTS failure probability, (2) EPS and HPCS EDG frequency of start demands (demands per reactor year), and (3) EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: (1) EPS EDG FTS failure probability, (2) EPS EDG FTLR failure probability, (3) EPS EDG unavailability, and (4) EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Next Generation Heat Transfer Fluids for Two-Phase Immersion Cooling of Data Centers

The purpose of this study is to evaluate the performance of next generation dielectric fluids in a Two-Phase Immersion Cooling (2PIC) system, which was designed for use in data centers. Hence, this report contains the performance evaluations of a new developmental dielectric fluid, Opteon™ 2P50, in a commercially available small-scale 2PIC system under typical and off-design range of operating conditions. Accordingly, ambient temperature and thermal loads were varied to simulate different ambient conditions. Additionally, this research report describes the development of a semi-empirical lumped model to predict the energy efficiency of the 2PIC system using Opteon™ 2P50 across a wide range of conditions. The model aims to offer a comprehensive understanding of the system’s efficiency and potential improvements. The outcomes of this study are expected to contribute to the adoption of sustainable 2PIC cooling technologies in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗