Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle beam measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Precise magnetic field mapping of the EMPHATIC Phase 1 magnet with COMSOL

A compact Halbach array magnet is used to measure the momentum of the secondary particles in EMPHATIC(Experiment to Measure the Production ofHadrons At a Test beam InChicagoland). Hall probe data was taken for the central cylindrical bore of the magnet and a field map was constructed. COMSOL Multiphysics® Software is used for modeling the magnet and constructing the corresponding magnetic field map. Here, we present a fitting approach where the hall probe data is used to determine a 1mm-spacing map of the entire volume of the magnet using COMSOL. The new map will allow for linear interpolation within the volume, and expand the map to outside the measurement volume, thus increasing the acceptance and precision of EMPHATIC's tracking system.

47 OTHER INSTRUMENTATION↗

Space-Charge Effects in Ionization Beam Profile Monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs and develop an effective algorithm to reconstruct the beam sizes from the measured IPM profiles. Efficiency of the developed theory is illustrated in application to the Fermilab 8 GeV proton Booster IPMs.

Shiltsev, Vladimir D.↗

Resonant Doppler velocimetry in supersonic nitrogen flow

The development of the Resonant Doppler Velocimeter (RDV) is discussed. It is a new nonintrusive laser technique for flow diagnosis. The RDV technique is applied to supersonic nitrogen flow with sodium atoms as tracer particles. The measurements are achieved by shining a tunable single frequency laser beam into the flow. The resonant absorption spectrum of the seeded species is determined by observing the fluorescence signal intensity as a function of excitation wavelength. By comparing the peak absorption wavelength with a reference frequency marker, the flow velocity along the excitation beam can be obtained through the Doppler shift relation. By fitting the spectrum with a theoretical line profile, the static temperature and pressure of the flow an be determined.

Cheng, S. W. S.↗

Programmable Multiple-Ramped-Voltage Power Supply

Ramp waveforms range up to 2,000 V. Laboratory high-voltage power-supply system puts out variety of stable voltages programmed to remain fixed with respect to ground or float with respect to ramp waveform. Measures voltages it produces with high resolution; automatically calibrates, zeroes, and configures itself; and produces variety of input/output signals for use with other instruments. Developed for use with ultraviolet spectrometer. Also applicable to control of electron guns in general and to operation of such diverse equipment used in measuring scattering cross sections of subatomic particles and in industrial electron-beam welders.

Ajello, Joseph M.↗

Fuel spray data with LDV

Droplet size and two component velocities in the severe environment of an operating gas turbine combustor system can be measured simultaneously using the solar laser morphokinetomer (SLM) which incorporates the following capabilities: (1) measurement of a true two-dimensional velocity vector with a range of + or - (0.01-200 m/sec); (2) measurement of particle size (range 5 to 300 micron m) simultaneously with the measurement of velocity; (3) specification of probe volume position coordinates with a high degree of accuracy (+ or - 0.5 mm); (4) immediate on-line data checks; and (5) rapid computer storage of acquired data. The optical system of the SLM incorporates an ultrasonic beam splitter to allow the measurement of a two-dimensional velocity vector simultaneously with particle size. A microprocessor with a limited storage capability permits immediate analysis of test data in the test cell.

Rohy, D. A.↗

Evaluating the ProtoDUNE-SP Detector Performance to Measure a 6 GeV/c Positive Kaon Inelastic Cross Section on Argon

The ProtoDUNE Single-Phase Liquid Argon Time Projection Chamber \\ (ProtoDUNE-SP LArTPC) is a prototype for the Deep Underground Neutrino Experiment (DUNE), a future long-baseline neutrino oscillation experiment. Based at the CERN Neutrino Platform, ProtoDUNE-SP LArTPC collected data from a charged test beam in the fall of 2018. It then took data of cosmic-ray muons from November 2018 to the summer of 2020. The main goals of the prototype were to measure parameters related to charged particle passage in argon and evaluate the performance of the detector to inform future DUNE Far Detector development. The test beam provided kaons, pions, muons, protons, and electrons to the detector. These particles represent common final state particles in neutrino interactions, therefore providing information to DUNE on modeling charged particles in argon for its neutrino physics program. In addition to neutrino physics, DUNE has proposed an analysis using the DUNE Far Detector module to set limits for proton decay through the decay channel $p\rightarrow K^++\bar{\nu}$. This measurement would require information on kaons in argon, providing ProtoDUNE-SP LArTPC another opportunity to aid DUNE. This thesis describes the calibration of ProtoDUNE-SP and its detector performance, which serves as a benchmark for the performance of the DUNE Far Detector modules. A specific calibration highlighted is the evaluation of the liquid argon purity in the detector. These measurements use cosmic-ray muons reconstructed in the detector that are calibrated and matched to data from scintillator strips external to the TPC, known as the Cosmic Ray Tagger (CRT). The thesis will discuss the algorithms to match the data between the ProtoDUNE-SP LArTPC and the CRT and discuss the liquid argon purity measurements using one of the algorithms. Data sets of calibrated tracks measured the liquid argon contamination as consistently below 100 ppt oxygen equivalent. After these discussions on the ProtoDUNE-SP LArTPC detector, the thesis will present an evaluation of the inclusive inelastic, sometimes referred to as a reactive, cross section on argon of kaons from the ProtoDUNE-SP test beam with an average momentum of 6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Physics Models of Geant4 Versions 10.4.p03, 10.6.p02 and 10.7.p01 using Data from the CMS Experiment

CMS tuned its simulation program and chose a specific physics model of Geant4 by comparing the simulation results with dedicated test beam experiments. Test beam data provide measurements of energy response of the calorimeter as well as resolution for well identified charged hadrons over a large energy region. CMS continues to validate the physics models using the test beam data as well as collision data from the Large Hadron Collider. Isolated charged particles are measured simultaneously in the tracker as well as in the calorimeters. These events are selected using dedicated triggers and are used to measure the response in the calorimeter. Different versions of Geant4 (10.2.p02, 10.4.p03, 10.6.p02) have been used by CMS for its Monte Carlo production and a new version (10.7.p01) is now chosen for future productions. A suitable physics list (collection of physics models) is chosen by optimizing performance against accuracy. A detailed comparison between data and Geant4 predictions is presented in this paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Extinction Measurements of Dust Density in the GMRO Regolith Test Bin

A regolith simulant test bin was constructed and completed in the Granular Mechanics and Regolith Operations (GMRO) Lab in 2013. This Planetary Regolith Test Bed (PRTB) is a 64 sq m x 1 m deep test bin, is housed in a climate-controlled facility, and contains 120 MT of lunar-regolith simulant, called Black Point-1 or BP-1, from Black Point, AZ. One of the current uses of the test bin is to study the effects of difficult lighting and dust conditions on Telerobotic Perception Systems to better assess and refine regolith operations for asteroid, Mars and polar lunar missions. Low illumination and low angle of incidence lighting pose significant problems to computer vision and human perception. Levitated dust on Asteroids interferes with imaging and degrades depth perception. Dust Storms on Mars pose a significant problem. Due to these factors, the likely performance of telerobotics is poorly understood for future missions. Current space telerobotic systems are only operated in bright lighting and dust-free conditions. This technology development testing will identify: (1) the impact of degraded lighting and environmental dust on computer vision and operator perception, (2) potential methods and procedures for mitigating these impacts, (3) requirements for telerobotic perception systems for asteroid capture, Mars dust storms and lunar regolith ISRU missions. In order to solve some of the Telerobotic Perception system problems, a plume erosion sensor (PES) was developed in the Lunar Regolith Simulant Bin (LRSB), containing 2 MT of JSC-1a lunar simulant. PES is simply a laser and digital camera with a white target. Two modes of operation have been investigated: (1) single laser spot - the brightness of the spot is dependent on the optical extinction due to dust and is thus an indirect measure of particle number density, and (2) side-scatter - the camera images the laser from the side, showing beam entrance into the dust cloud and the boundary between dust and void. Both methods must assume a mean particle size in order to extract a number density. The optical extinction measurement yields the product of the 2nd moment of the particle size distribution and the extinction efficiency Qe. For particle sizes in the range of interest (greater than 1 micrometer), Qe approximately equal to 2. Scaling up of the PES single laser and camera system is underway in the PRTB, where an array of lasers penetrate a con-trolled dust cloud, illuminating multiple targets. Using high speed HD GoPro video cameras, the evolution of the dust cloud and particle size density can be studied in detail.

lunar simulant↗

Simultaneous 10 kHz three-dimensional CH 2 O and tomographic PIV measurements in a lifted partially-premixed jet flame

High-speed, three-dimensional (3D) scalar-velocity field measurements are demonstrated in a lifted partially-premixed dimethyl-ether/air jet flame using simultaneous laser-induced fluorescence (LIF) of formaldehyde (CH 2 O) and tomographic particle image velocimetry (TPIV). The 3D LIF measurements are performed by raster scanning the laser beam from a 100 kHz pulse-burst laser across the probe volume using an acousto-optic deflector. The volumetric reconstruction of the LIF signal from ten parallel planes provides quasi-instantaneous 3D LIF measurements that are synchronized with 10 kHz TPIV measurements. Here, the temporally resolved CH 2 O-LIF and velocity field data are used to analyze Lagrangian particle trajectories and displacement speeds at the base of the lifted flame. The particle trajectories reveal flow structures that are difficult to observe in an Eulerian reference frame. Positive and negative displacement speeds are observed at the CH 2 O-LIF surfaces at the inner and outer regions of the jet flame with a maximum displacement speed of approximately eight times the laminar flame speed of a stoichiometric dimethyl-ether/air mixture. The observations in present study support formation of lean premixed flames near the flame base whose role in flame stabilization should be investigated in more detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of stability diagrams in the IOTA ring at Fermilab

Nonlinear focusing elements can enhance the stability of particle beams in high-energy colliders through Landau Damping, by means of the tune spread which is introduced. Here we discuss an experiment at Fermilab's Integrable Optics Test Accelerator (IOTA) which investigates the influence of nonlinear focusing elements, such as octupoles, on the beam’s transverse stability. In this experiment, we employ an anti-damper, an active transverse feedback system, as a controlled mechanism to induce coherent beam instability. By utilizing the anti-damper we can examine the impact of a nonlinear focusing element on the beam's transverse stability. The stability diagram, a tool used to determine the system's stability, is measured using a recently demonstrated method at the LHC. The experiment at IOTA adds insight towards this stability diagram measurement method by supplying a reduced machine impedance to investigate the machine impedance’s effect on the stability diagram, as well as by aiming to map out the full stability diagram by using a large phase range of the anti-damper. From this experiment in IOTA, we present the first results of stability diagram analysis with varying octupole currents.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

Feasibility study of transit photon correlation anemometer for Ames Research Center unitary wind tunnel plan

A laser transit anemometer measured a two-dimensional vector velocity, using the transit time of scattering particles between two focused and parallel laser beams. The objectives were: (1) the determination of the concentration levels and light scattering efficiencies of naturally occurring, submicron particles in the NASA/Ames unitary wind tunnel and (2) the evaluation based on these measured data of a laser transit anemometer with digital correlation processing for nonintrusive velocity measurement in this facility. The evaluation criteria were the speeds at which point velocity measurements could be realized with this technique (as determined from computer simulations) for given accuracy requirements.

Mayo, W. T., Jr.↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Direct cross section measurement of 102 Pd ⁢(𝛾,𝑝) and 102 Pd ⁢(𝛾,𝛼) for the astrophysical 𝑝 process

Background: A handful of neutron-deficient stable nuclei, known as the “p nuclei,” cannot be produced through astrophysical neutron capture processes. Instead, some of these nuclei are proposed to be produced by 𝛾-induced reactions on existing r- and s-process seeds. The specific astrophysical site or sites are not yet identified, however, with uncertainties in the cross sections of these 𝛾-induced reactions playing a role. Databases of reaction rates for astrophysical simulations often rely on theoretical statistical model calculations, such as Hauser-Feshbach, for rates where no experimental information is known. However, reasonable variations in the choice of parametrizations of various nuclear properties can create order-of-magnitude variations in the final predicted cross sections and reaction rates, which are then propagated through the models to the predicted final abundances. Purpose: To better constrain these statistical model calculations and ultimately reduce the uncertainties from the nuclear physics on our understanding of the p nuclei, a measurement of the cross sections of 𝛾-induced reactions on the p-nucleus 102 Pd was undertaken. This work represents the first measurement of its kind, using segmented silicon detectors to measure prompt charged particle emission from 𝛾-induced reactions. Methods: Quasimonoenergetic gamma beams from the High Intensity 𝛾 Source facility bombarded an enriched 102 Pd target. A segmented silicon array was arranged to detect the particles emitted from (𝛾,𝑝) and (𝛾,𝛼) reactions. Results: Reaction cross sections were deduced at multiple 𝛾-beam energies between 10 and 19 MeV, and compared to statistical model calculations using talys-1.96. The 102 Pd ⁢(𝛾,𝑝)⁢ 101 Rh reaction cross section was reasonably well reproduced by a subset of photon strength functions and level densities, though the strength to the ground state of 101 Rh was underestimated at higher incident gamma energies. The 102 Pd ⁢(𝛾,𝛼)⁢ 98 Ru was in general overpredicted by the various alpha-nucleus optical model potentials. Conclusions: While the theoretical cross sections used to model the (𝛾,𝑝) reactions for the p process may be reasonable, a more careful approach is needed in the case of (𝛾,𝛼). Further work to probe gamma-induced reaction cross sections at and near the p nuclei is warranted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining the average prompt-fission-neutron multiplicity for Pu 239 ( n , f ) via a Pu 240 ( α , α ' f ) surrogate reaction

The average prompt-fission-neutron multiplicity ν ¯ is of significance in the areas of nuclear theory, nuclear nonproliferation, and nuclear energy. In this work, the surrogate-reaction method has been used for the first time to indirectly determine ν ¯ for Pu 239 ( n , f ) via Pu 240 ( α , α ' f ) reactions. A Pu 240 target was bombarded with a beam of 53.9-MeV α particles. Scattered α particles, fission products, and neutrons were measured with the NeutronSTARS detector array. Values of ν ¯ were obtained for a continuous range of equivalent incident neutron energies between 0.25 and 26.25 MeV, and the results agree well with direct neutron measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scattering of 42-MeV alpha particles from Cu-65

The extended particle-core coupling model was used to predict the properties of low-lying levels of Cu-65. A 42-MeV alpha particle cyclotron beam was used for the experiment. The experiment included magnetic analysis of the incident beam and particle detection by lithium-drifted silicon semiconductors. Angular distributions were measured for 10 to 50 degrees in the center of mass system. Data was reduced by fitting the peaks with a skewed Gaussian function using a least squares computer program with a linear background search. The energy calibration of each system was done by pulsar, and the excitation energies are accurate to + or - 25 keV. The simple weak coupling model cannot account for the experimentally observed quantities of the low-lying levels of Cu-65. The extended particle-core calculation showed that the coupling is not weak and that considerable configuration mixing of the low-lying states results.

Stewart, W. M.↗