Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PTFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Editors’ Choice—Flooded by Success: On the Role of Electrode Wettability in CO 2 Electrolyzers that Generate Liquid Products

Economic operation of carbon dioxide (CO 2 ) electrolyzers generating liquid products will likely require high reactant conversions and product concentrations, conditions anticipated to challenge existing gas diffusion electrodes (GDEs). Notably, electrode wettability will increase as lower surface tension products (e.g., formic acid, alcohols) are introduced into electrolyte streams, potentially leading to flooding. To understand the hydraulically stable operating envelopes in mixed aqueous-organic liquid domains, we connect intrinsic electrode wettability descriptors to operating parameters such as electrolyte flow rate and current. We first measure contact angles of water-organic product dilutions on polytetrafluoroethylene (PTFE) and graphite surfaces as planar analogues for GDE components. We then use material balances around the reactive gas-liquid-solid interface to calculate product mass fractions as functions of water sweep rate and current. Product composition maps visualize the extent to which changes in cell performance influence capillary pressure, a determinant of GDE saturation. Analyses suggest that formic acid mixtures pose little risk for GDE flooding across a wide range of conditions, but effluents containing <30% alcohol by mass may cause flooding. This study reveals opportunities to integrate microstructural features and oleophobic surface treatments into GDEs to repel aqueous-organic mixtures and expand the window of stable operating conditions.

25 ENERGY STORAGE↗

Durability Optimization of CO 2 Electrolyzers for Syngas Evolution

Recently, there has been an increased interest in mitigating anthropogenic CO 2 emissions through the electrochemical conversion of CO 2 into fuels and fuel feedstocks, including hydrogen gas (H 2 ), carbon monoxide (CO), and mixtures of the two to yield syngas. Commercial applications of these systems require high catalytic selectivity for the desired products, while exhibiting operational lifetimes exceeding thousands of hours. Advancements in this field have produced systems that display high selectivity of the desired products at faradaic efficiencies exceeding 95%. Despite the advancements made in CO 2 electrolysis, system durability remains a standing challenge in the field. CO 2 electrolyzer lifetimes are often limited by carbonate fouling, catalyst degradation, detrimental flooding of electrode microporous layers and anion exchange membrane (AEM) failures. In this report, a 5 cm 2 membrane electrode assembly (MEA) device is used to investigate potential failure modes and to optimize AEM CO 2 electrolyzer operation. Key findings of this study include the importance of CO 2 flow rate, use of a thin PiperION PTFE-reinforced membrane, optimizing compression to enhance contact under 40 in-lb compression, and the effect of more compressible, commercial iridium oxide anodes on system durability.

Abouremeleh, Mohammed H. [Lawrence Berkeley Nation↗

A rapid assay for assessing bacterial effects on Arabidopsis thermotolerance

Abstract Background The role of beneficial microbes in mitigating plant abiotic stress has received considerable attention. However, the lack of a reproducible and relatively high-throughput screen for microbial contributions to plant thermotolerance has greatly limited progress in this area, this slows the discovery of novel beneficial isolates and the processes by which they operate. Results We designed a rapid phenotyping method to assess the effects of bacteria on plant host thermotolerance. After testing multiple growth conditions, a hydroponic system was selected and used to optimize an Arabidopsis heat shock regime and phenotypic evaluation. Arabidopsis seedlings germinated on a PTFE mesh disc were floated onto a 6-well plate containing liquid MS media, then subjected to heat shock at 45 °C for various duration. To characterize phenotype, plants were harvested after four days of recovery to measure chlorophyll content. The method was extended to include bacterial isolates and to quantify bacterial contributions to host plant thermotolerance. As an exemplar, the method was used to screen 25 strains of the plant growth promoting Variovorax spp. for enhanced plant thermotolerance. A follow-up study demonstrated the reproducibility of this assay and led to the discovery of a novel beneficial interaction. Conclusions This method enables rapid screening of individual bacterial strains for beneficial effects on host plant thermotolerance. The throughput and reproducibility of the system is ideal for testing many genetic variants of Arabidopsis and bacterial strains.

59 BASIC BIOLOGICAL SCIENCES↗

Reflector coatings development (FY2020 End of Year Report)

X-ray detection instrumentation has been developed and manufactured at LANL for various DOE programs. One way to improve light collection efficiency, for a scintillator type detector, is to apply suitable reflectors. The coating capability and fabrication procedure for Al reflective coatings was established in FY19 at MST-7. Al reflective coatings with good stability, good adhesion to LSO, and reflectivity (R) up to 78% were fabricated. Materials with higher diffuse reflectivity (such as Teflon tape R=99%) are desirable. A literature search revealed a number of materials in the form of paint or free standing tape with diffuse R = 98- 99%. However, for the intended application such reflectors have to be applied in the form of a coating with strong adhesion to LSO crystals. The purpose of the FY20 project was to develop thin film coating techniques for PTFE (known as Teflon) reflectors and fabricate reflective coatings on provided LSO crystals.

36 MATERIALS SCIENCE↗

Measuring aerosol collection efficiency for the Bladewerx “New Speclon TM 5” and the older “Speclon TM 5” filter

Bladewerx TM LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon TM PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon TM filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. The LANL Aerosol Engineering Facility received air filter material from Bladewerx, referred to as “New Speclon 5” in this document, in order to distinguish from filter material that was previously received (referred to as “Speclon 5” in this document). In this document, the aerosol collection efficiency and airflow resistance (pressure drop) were measured for the New Speclon 5 filter material.

61 RADIATION PROTECTION AND DOSIMETRY↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Savannah River National Laboratory Participation in the International Atomic Energy Agency CPC Interlaboratory Comparison Exercise 2

International Atomic Energy Agency Safeguards Analytical Services (IAEA-SGAS) oversees coordinating the second Controlled Potential Coulometry Quality Control Interlaboratory Comparison (CPC QC ILC) on behalf of the Nuclear Material Laboratory (NML). The purpose of the exercise is to: (1) verify the ability of participating laboratories to measure the Pu concentration in the sample solutions, and (2) estimate the method performance (repeatability and intermediate reproducibility). Sample shipping coordination was performed by IAEA-SGAS. The test sample is a plutonium nitrate solution (estimated molarity of 3-5 M), delivered in two PTFE screw-capped quartz ampoules. Each participating laboratory is to receive two ampoules. Each ampoule holds approximately 8 mL of solution containing approximately 10 mg Pu/g. The gross weights of the ampoules were provided. The test sample is assumed to have an iron content below the level of significance for the CPC. The isotopic composition of the plutonium test sample was provided; however, no analysis date was provided. In addition, IAEA-SGAS provided analytical instructions to participants. On September 20, 2022, SRNL received the samples sent by IAEA-SGAS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The linear thermal expansion of 11 polymers from approximately -100 to +100°C

The linear coefficient of thermal expansion has been measured for 11 polymers from approximately -100 to +100°C. The polymers tested were poly(tetrafluoroethylene) (PTFE), poly(chlorotrifluoroethylene) (PCTFE), three polyethylenes; high density (HDPE), ultra-high molecular weight (UHMWPE) and cross-linked (XPE). The commercial fluoropolymers Kel-F 800 (also known as FK-800®) and THV 500®were tested together with samples of poly(ether ether ketone) (PEEK), poly(methyl methyl methacrylate) (PMMA), polycarbonate (PC) and poly(vinylidene fluoride) (PVDF). Polynomial fits were made to the data over appropriate ranges allowing the expansivity (α) to be estimated.

36 MATERIALS SCIENCE↗

The mechanical properties of Kel-F 800 (FK-800) as a function of crystallinity

Kel-F 800 is a copolymer of chlorotrifluoroethylene PTFE (75 wt. %) and vinylidene fluoride PVDF (25 wt. %). It has previously been used as a PBX binder for insensitive explosives such as PBX 9502 and LX-17. 3M started production of Kel-F 800 in 1957 and small-scale batches continued to be made until 2002 when production ceased due to environmental concerns regarding one of the emulsifiers used during production. Around 2000 the Kel-F 800 name was changed to FK-800 to avoid trademark concerns because rights to produce another polymer with a similar tradename (Kel-F 81) had been sold to another manufacturer. The Kel designation came from the original manufacturer of PCTFE (Kel-F 81), the Kellog company. To avoid confusion this document will only refer to Kel-F 800. In 2006, production of small-scale batches of Kel-F 800 was started again by 3M in response to customer enquiries. This new material, the first blended batch is referred to as LOT 1, was produced with a different emulsifier than used previously. Because Kel-F 800 is made in a small batch reactor, considerable variation in crystallinity can be expected from lot to lot and year to year. In many ways, this is not significant since the material is dissolved in a solvent (often MEK, ethylmethyl ketone or ethyl acetate) for PBX production purposes. This destroys the as received crystallinity and the resulting crystallinity in the processed material is a function of polymer molecular weight and thermal history. Producing large billets of Kel-F 800 from solvent extraction is not practical and so a compression molding technique has been used above the melting temperature. This method also removes residual crystallinity from the supplied granules. The molecular weight of a polymer can be estimated by several techniques, the most common being gel permittivity chromatography (GPC), size exclusion chromatography (SEC) and shear rheometry measurements of polymer/solvent solutions. Changes in molecular weight will affect the crystallization rate and the maximum crystallinity reached for a specific thermal history. Both references agree that the new LOT 1 material molecular weight falls within the deviation found from averaging previous historical lots of Kel-F 800.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Triboelectric Nanogenerator Repeatability and Reproducibility Study

The development of triboelectric nanogenerators (TENGs) has largely focused on optimizing output performance, often at the expense of other critical research considerations such as the development of reliable technical procedures. In particular, the reliability of reported results—specifically repeatability and reproducibility—remains underexplored and is frequently limited to brief discussion within available literature. Without rigorous validation through repeatability and reproducibility studies, the credibility and broader applicability of reported findings remain uncertain. This study addresses this gap by systematically evaluating the repeatability and reproducibility of TENG performance data. Five polymer materials—Kapton, polyethylene (PE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyvinylidene fluoride (PVDF)—were investigated across all pairwise combinations of 25 total combinations for the reproducibility study and three selected pairs of the 25 samples were selected for the repeatability study. For each TENG pairing, we analyzed the methodology, experimental procedures, and resulting performance data to quantify consistency and reliability. The objective of this work is to assess the validity of the collected dataset and determine whether the observed performance trends are consistent for use in future TENG design and optimization studies. Establishing reliable and reproducible data is essential for advancing the development of high-output TENG systems and ensuring their dependable implementation in practical applications.

36 MATERIALS SCIENCE↗

Cellulose molecular weight of corn stover with cotreatment

Here we present a dataset of cellulose molecular weights from corn stover after a cotreatment process. The corn stover sample was subjected to a combination of mechanical disruption (ball milling) and consolidated bioprocessing (CBP) process using the bacterium C. thermocellum at 60 grams/L solids loadings. Cellulose was isolated from control, no cotreatment control, and cotreatment corn stover. Cellulose was then derivatized using anhydrous pyridine and phenyl isocyanate over 48 h at 70 ºC. The reaction was quenched by anhydrous methanol. Methanol and water mixture (7:3, v/v) was added dropwise to promote precipitation of the cellulose derivative. The solids were collected by filtration and thoroughly washed with the methanol and water mixture followed by water. The cellulose derivative was dried overnight under vacuum at 40°C. The obtained cellulose tricarbanilates was then dissolved in tetrahydrofuran (THF) at 1.0 mg/mL and the solution was filtered through a 0.45 µm PTFE filter and placed in an auto-sampler vial. The molecular weight of cellulose was measured by Agilent GPC SECurity 1200 system equipped with four Waters Styragel columns (i.e., HR0.5, HR2, HR4, and HR6) and a UV detector (270 nm). THF was used as the mobile phase. Data collection and processing was performed by Polymer Standards Service WinGPC Unity software (Build 6807). The molecular weight was calculated relative to the polystyrene calibration curve. The data on molecular weights provided information about the effects of cotreatment on corn stover cellulose molecular changes.

Cellulose, molecular weights, corn stover, cotreat↗

Unnamed Pt(Cu 0.67 Sn 0.33 ) from the Bolshoy Khailyk River, Western Sayans, Russia, and a Review of Related Compounds and Solid Solutions

We describe a potentially new species of a platinum cupride–stannide mineral (PCSM) of composition Pt(Cu 0.67 Sn 0.33 ). It occurs in a placer deposit in the River Bolshoy Khailyk, southern Krasnoyarskiy kray, Russia. A synthetic equivalent of PCSM was obtained and characterized. The PCSM occurs as anhedral or subhedral grains up to 15 μm × 30 μm in association with various platinum-group minerals, Rh–Co-rich pentlandite and magnetite, all hosted by a placer grain of Cu–Au–Pt alloy. Synchrotron micro-Laue diffraction studies indicate that the PCSM mineral is tetragonal and belongs to the inferred space-group P4/mmm (#123). Its unit-cell parameters are a = 2.838 (3) Å, c = 3.650 (4) Å, and V = 29.40 (10) Å 3 , and Z = 1. The c:a ratio calculated from the unit-cell parameters is 1.286. These characteristics are in good agreement with those obtained for specimens of synthetic Pt(Cu 0.67 Sn 0.33 ). A review on related minerals and unnamed phases is provided to outline compositional variations and extents of solid solutions in the relevant systems PtNi–PtFe–PtCu, PdCu–PdHg–PdAu, PdHg–PtHg, and AuCu–PtCu. The PCSM-bearing mineralization appears to be related genetically with an ophiolitic source-rock of the Aktovrakskiy complex of the western Sayans. The unnamed phase likely crystallized from microvolumes of a highly fractionated melt rich in Cu and Sn.

36 MATERIALS SCIENCE↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of Vehicle Fuel System Elastomers and Plastics with Test Fuels Representing Gasoline Blended with 10% Ethanol (E10) and 16% Isobutanol (iBu16)

The compatibilities of fuel system elastomers and plastics were evaluated for test fuels containing 16 vol.% isobutanol (iBu16) and 10 vol.% ethanol (E10). Elastomers included two fluorocarbons, four acrylonitrile butadiene rubbers (NBRs), and one type of fluorosilicone, neoprene, and epichlorohydrin/ethylene oxide. Plastic materials included four nylon grades, three polyamides, polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), ethylene tetrafluoroethylene (ETFE), polyphenylene sulfide (PPS), high-density polyethylene (HDPE), polybutylene terephthalate (PBT), polyoxymethylene (POM), flexible polyvinylchloride (PVC), polyetherimide (PEI), polyetheretherketone (PEEK), and a phenol formaldehyde reinforced with glass fiber (GFPF). For each polymer material, the volume, mass, and hardness were measured before and after drying. Dynamic mechanical analysis (DMA) measurements were also performed on the dried specimens.For the elastomer materials the measured properties were similar for both fuels. The fluorocarbons and fluorosilicone swelled the least (~20%), while more moderate (20-45%) expansion occurred for the two NBR hose grades and (ECO). HNBR, neoprene, and silicone exhibited high swelling and softening, which likely precludes their use in many fuel systems. For the plastic materials, the observed swell was low; Nylon 11 swelled around 15%, but otherwise, their measured swell was <10%. Many of the plastics also showed sensitivity to alcohol type, as the E10 test fuel often imparted appreciably higher swell than iBu16. In general, the plastic materials showed good compatibility with the iBu16 and E10 test fuels. Here, the sole exception was the PVC material, which was structurally degraded from exposure to either fuel type. Compositional analysis showed high fuel retention in Nylon 12 and PVC. PVC also experienced a significant reduction in plasticizer compounds following exposure, which resulted in embrittlement and an increase in the glass-to-rubber transition temperature.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Biodiesel, Renewable Diesel, 1-Octanol, Dibutoxymethane, n-Undecane, Hexyl hexanoate and 2-Nonanone with Infrastructure Plastics as Blends with Diesel

In this work the volume and hardness were measured for thermoplastics and thermosetting resins with diesel containing up to 30% of the following blend stocks: biodiesel, renewable diesel, n-undecane, dibutoxymethane, 1-octanol, hexyl hexanoate, and 2-nonanone. Thermoplastics included polyphenylene sulfide (PPS), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), polyoxymethylene (POM), polybutylene terephthalate (PBT), polypropylene (PP), high density polyethylene (HDPE), nylons, acetals, polyetherimide (PEI), polyetheretherketone (PEEK), a PET co-polymer, polyphthalamides (PPAs), polyarylamide (PARA) and ethylene tetrafluoroethylene (ETFE). Three thermosetting resins were also evaluated. The material specimens were exposed to the test fuels under ambient conditions for 16 weeks. In general, the volume and hardness of the specimens were relatively unaffected following exposure to the test fuels; however, n-undecane produced significant swelling in polypropylene and may not be suitable for use with this material. N-undecane, along with hexyl hexanoate and 2-nonanone also caused low levels of swelling in nylon, which was not significant enough to preclude the use of nylons in sealing applications with these fuels.

09 BIOMASS FUELS↗

Dynamic valve seal is reliable at cryogenic temperatures

C-shaped PTFE /polytetrafluorethylene/ seal ring provides a reliable seal in cryogenic fluids over a fluid pressure range of 0 to 2000 psig. It is interference-fitted internally with a metal expander ring and a metal compressor ring.

Moxley, H. E.↗

Refractory-metal compound impregnation of polytetrafluoroethylene

Process impregnates polytetrafluoroethylene /PTFE/ with rhenium or molybdenum compounds. The refractory metals impregnated PTFE combines chemical inertness with electrical conductivity. They are useful for electro-chemical cells, chemical processing equipment, catalysts, electrostatic charge removal, RF gasketing, and cable shielding.

Leibecki, H. F.↗